PubMed Health⌕ Search

Biomedical subjects

Rainer Leitgeb

Publications and source records attributed to Rainer Leitgeb.

5 recordsLinked to original sources

Three-dimensional adaptive optics ultrahigh-resolution optical coherence tomography using a liquid crystal spatial light modulator.

A liquid crystal programmable phase modulator (PPM) is used as correcting device in an adaptive optics system for three-dimensional ultrahigh-resolution optical coherence tomography (UHR OCT). The feasibility of the PPM to correct high order aberrations even when using polychromatic light is studied, showing potential for future clinical use. Volumetric UHR OCT of the living retina, obtained with up 25,000A-scans/s and high resolution enables visualization of retinal features that might correspond to groups of terminal bars of photoreceptors at the external limiting membrane.

Humans↗

Transversal phase resolved polarization sensitive optical coherence tomography.

We present a novel optical coherence tomography (OCT) method to measure backscattered intensity and birefringence properties (retardation and fast axis orientation) and apply it to imaging of human ocular tissue. The method is based on a Mach Zehnder interferometer, on transversal scanning, and on a polarization sensitive two-channel detection. A highly stable carrier frequency is generated by acousto-optic modulators (AOMs). This allows a phase sensitive demodulation by the lock-in technique. Since the recording of individual interference fringes is avoided by this method the amount of data to be recorded and processed is considerably reduced. We demonstrate this method on human cornea and anterior chamber angle and present, to the best of our knowledge, the first OCT images of retardation and fast axis orientation of the anterior chamber angle region in vivo.

Anterior Chamber↗

Speckle reduction in optical coherence tomography by frequency compounding.

We are investigating the possibility of a frequency compounding method for speckle reduction in optical coherence tomography. The method is based on incoherent summation of the magnitudes of two independent interferometric signals, which were recorded at two different center wavelengths simultaneously. We derive the corresponding statistics and compare the theoretical results with measurements obtained in a uniformly scattering sample. Finally we demonstrate our method by comparing images of human skin recorded in vivo with and without frequency compounding. The compounding method results in an increased contrast and improved image quality without loss of resolution.

Algorithms↗

Quantitative performance of bifocal and multifocal intraocular lenses in a model eye: point spread function in multifocal intraocular lenses.

OBJECTIVE: To compare the optical properties of bifocal diffractive and multifocal refractive intraocular lenses. METHODS: A model eye with a pupil 4.5 mm in diameter was used to determine the point spread function (PSF) of the distance focus and near focus of a diffractive bifocal intraocular lens (IOL) (model 811E; Pharmacia Inc, Columbus, Ohio) and of a refractive multifocal IOL (model SA40N; Allergan Optical Inc, Irvine, Calif) to compare them with PSFs of foci of corresponding monofocal lenses. For interpreting the PSFs the through focus response, the modulation transfer function, and the Strehl ratio were evaluated. RESULTS: The intensity of the distance focus of the bifocal diffractive lens reached 58.5% and the near focus attained 42.7% of the intensity of a corresponding monofocal lens. The maximal halo intensity surrounding both foci was approximately 4.5%. The distance peak of the refractive multifocal IOL was 73.4% and the near peak 25.1% of a corresponding monofocal lens. The out-of-focus image overlaying the distance focus of the refractive multifocal IOL was approximately 3% of the light intensity of the distance focus, whereas the PSF of the near focus of the multifocal IOL is substantially affected by out-of-focus images. The computed modulation transfer functions show better results for the monofocal lenses, similar results for the tested distance foci, and clear advantages for the bifocal diffractive near focus. CONCLUSIONS: Modulation transfer functions reveal comparable properties for distance vision and a superiority of the bifocal diffractive lens over the refractive multifocal lens for near vision.

Eye↗

In vivo human retinal imaging by Fourier domain optical coherence tomography.

We present what is to our knowledge the first in vivo tomograms of human retina obtained by Fourier domain optical coherence tomography. We would like to show that this technique might be as powerful as other optical coherence tomography techniques in the ophthalmologic imaging field. The method, experimental setup, data processing, and images are discussed.

Adult↗