PubMed Health⌕ Search

PubMed · 15128203

Transversal phase resolved polarization sensitive optical coherence tomography.

Abstract

We present a novel optical coherence tomography (OCT) method to measure backscattered intensity and birefringence properties (retardation and fast axis orientation) and apply it to imaging of human ocular tissue. The method is based on a Mach Zehnder interferometer, on transversal scanning, and on a polarization sensitive two-channel detection. A highly stable carrier frequency is generated by acousto-optic modulators (AOMs). This allows a phase sensitive demodulation by the lock-in technique. Since the recording of individual interference fringes is avoided by this method the amount of data to be recorded and processed is considerably reduced. We demonstrate this method on human cornea and anterior chamber angle and present, to the best of our knowledge, the first OCT images of retardation and fast axis orientation of the anterior chamber angle region in vivo.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael Pircher, Erich Goetzinger, Rainer Leitgeb, Christoph K Hitzenberger. 2004-04-07. Transversal phase resolved polarization sensitive optical coherence tomography.. https://doi.org/10.1088/0031-9155%2F49%2F7%2F013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Model of pulsatile-flow of aqueous humor through the iris-lens canal.

PURPOSE: To present a model of pulsatile-flow of aqueous humor from posterior (PC) to anterior chamber (AC) and to analyze the sensitivity of this novel model in detecting typical high risk conditions predisposing to pupillary block. METHODS: The model assumes noncontinuous flow of aqueous through the iris-lens canal. Aqueous that fills the canal will be ejected toward the AC-side of the canal at certain time intervals, and between 2 events of aqueous ejection there is no actual flow through this canal. Pupillary pumping rate (PPR) was calculated from the aqueous flow rate and the calculated volume of iris-lens canal. RESULTS: PPR values were generated by incorporating pupillary diameter (1 to 8 mm), aqueous flow rate (1 to 2.5 microL/min), and iris-lens canal width (0.5 to 2 mm) and height (3-9 microm) in numerical experimentation with the present model. PPR showed inverse dependence on iris-lens canal height and pupillary diameter and was directly proportional to aqueous flow rate, in agreement with the steady-flow model. However, contrary to the steady-flow model, PPR showed inverse dependence on iris-lens canal width and predicted the anticipated PC-AC pressure gradient changes at simulated light-dark transition in eyes of patients with clinically narrow angles and ultrasound biomicroscopy evidenced pupillary block. CONCLUSIONS: Upon the incorporation of real ultrasound biomicroscopy measurements in numerical experimentations with both models, the present pulsatile-flow model, contrary to the steady-flow model, showed good predictability of PC-AC pressure gradient changes in a typical condition predisposing to pupillary block.

Anterior Chamber↗