Rainer Raupach

Publications and source records attributed to Rainer Raupach.

9 recordsLinked to original sources

The effect of dose reduction and feasibility of edge-preserving noise reduction on the detection of liver lesions using MSCT.

The purpose of this study was to assess the effect of dose reduction and the potential of noise reduction filters on image quality and the detection of liver lesions using MSCT. Twenty-nine patients with a total of 40 liver lesions underwent 16-slice CT (120 kV; 180 mAs). Virtual noise was added to CT raw datasets simulating effective mAs levels of 155, 130, 105, 80, 55, 30 and 10 mAs. All datasets were post-processed with an edge-preserving noise-reduction filter (ANR-3D), yielding a total of 15 datasets per patient. Ten radiologists performed independent evaluations of image quality, the presence of liver lesions and diagnostic confidence. Quantitative noise and contrast-to-noise ratios (CNR) were obtained. Superior image quality (P < 0.02), reduction of image noise (P < 0.001) and the increase of lesion-to-liver CNR (P < 0.001) were observed in images processed with the ANR-3D filter. Sensitivity for lesion detection remained unchanged down to 105 mAs (CTDI(w) 6.6 mGy) without filter and 80 mAs (CTDI(w) 5.1 mGy) with ANR-3D. Confidence was rated significantly higher for datasets reconstructed with ANR-3D. The use of a noise-reducing, but edge-preserving filter (ANR-3D) is a promising option to reduce further the radiation dose in liver CT.

Adult↗

64- Versus 16-slice CT angiography for coronary artery stent assessment: in vitro experience.

OBJECTIVES: We sought to assess the visualization of different coronary artery stents and the delineation of in-stent stenoses using 64- and 16-slice multidector computed tomography (MDCT). MATERIALS AND METHODS: A total of 15 different coronary stents with a simulated in-stent stenosis were placed in a vascular phantom and scanned with a 16-slice and a 64-slice MDCT at orientations of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis. Visible lumen diameter and attenuation in the stented and the unstented segment of the phantom were measured. Three readers assessed stenosis delineation and visualization of the residual lumen using a 5-point scale. RESULTS: Artificial lumen narrowing (ALN) was significantly reduced with 64-slice CT compared with 16-slice CT. At an angle of 0 degree, 45 degrees, and 90 degrees relative to the scanner's z-axis, the ALN for 16-slice CT was 42.2%, 39.8%, and 44.0% using a slice-thickness of 1.0 mm and 40.9%, 40.4%, and 41.6% using a slice thickness of 0.75 mm, respectively. With 64-slice CT, the ALN was 39.1%, 37.3%, and 36.0% at the respective angles. The differences between attenuation values in the stented and unstented segment of the tube were significantly lower for 64-slice CT. Mean visibility scores were significantly higher for 64-slice CT. CONCLUSION: Use of the 64-slice CT results in superior visualization of the stent lumen and in-stent stenosis compared with 16-slice CT, especially when the stent is orientated parallel to the x-ray beam.

Coronary Angiography↗

First performance evaluation of a dual-source CT (DSCT) system.

We present a performance evaluation of a recently introduced dual-source computed tomography (DSCT) system equipped with two X-ray tubes and two corresponding detectors, mounted onto the rotating gantry with an angular offset of 90 degrees . We introduce the system concept and derive its consequences and potential benefits for electrocardiograph [corrected] (ECG)-controlled cardiac CT and for general radiology applications. We evaluate both temporal and spatial resolution by means of phantom scans. We present first patient scans to illustrate the performance of DSCT for ECG-gated cardiac imaging, and we demonstrate first results using a dual-energy acquisition mode. Using ECG-gated single-segment reconstruction, the DSCT system provides 83 ms temporal resolution independent of the patient's heart rate for coronary CT angiography (CTA) and evaluation of basic functional parameters. With dual-segment reconstruction, the mean temporal resolution is 60 ms (minimum temporal resolution 42 ms) for advanced functional evaluation. The z-flying focal spot technique implemented in the evaluated DSCT system allows 0.4 mm cylinders to be resolved at all heart rates. First clinical experience shows a considerably increased robustness for the imaging of patients with high heart rates. As a potential application of the dual-energy acquisition mode, the automatic separation of bones and iodine-filled vessels is demonstrated.

Coronary Angiography↗

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents.

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% +/-10%) and more realistic lumen attenuation (222 HU +/-66 HU) at the expense of increased noise (15.3 HU +/-3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent diameter.

Alloys↗

Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

To compare the effect of different reconstruction kernels and a noise-reducing postprocessing filter on the delineation of coronary artery stents in 16-slice CT-angiography. Ten patients with coronary stents (seven LAD, five RCX and three RCA) were examined with a 16-slice MDCT using standard acquisition parameters. Images were reconstructed using a medium soft (B30f) and a dedicated, edge-enhancing kernel (B46f). Additional postprocessing with an edge-preserving filter was performed on B46f images to reduce the image noise. In multiplanar reformations (MPRs) along and perpendicular to the stent axis, intraluminal attenuation values and the visible lumen diameter were measured. Image noise was measured in the subcutaneous fat using a region of interest (ROI) technique. Arterial enhancement in the aorta was 275.1 HU. Attenuation in the stent lumen was 390.4, 340.0 and 346.8 HU in MPRs derived from B30f, original B46 and postprocessed B46f images. The mean noise level was 20.4, 35.0 and 24.9 HU respectively. The visible lumen diameter was significantly greater in B46f and postprocessed B46f images (2.17 and 2.16 mm), compared to 1.93 mm in B30f images (p<0.01). Edge-enhancing reconstruction kernels increase the visible stent lumen, but also increase image noise. Dedicated postprocessing filters can reduce the introduced noise without a loss of spatial resolution.

Artifacts↗

CT images of abdomen and pelvis: effect of nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics.

The purpose of this study was to retrospectively assess the effect of a postprocessing nonlinear three-dimensional optimized reconstruction algorithm on image quality and lesion characteristics in abdominal and pelvic computed tomographic (CT) images. Institutional review board approved the HIPAA-compliant study protocol; informed consent was waived. Abdominal and pelvic CT images (40 patients; male-female ratio, 20:20; age range, 28-86 years) at 5-mm (n = 20) and 2-mm (n = 20) section thicknesses were postprocessed with the algorithm at three noise reduction levels. Image noise at the level of porta hepatis and acetabulum was evaluated with a five-point scale (1, no or minimal noise; 5, unacceptable noise), and presence and number of lesions and conspicuity were assessed. Statistical analysis was performed (Wilcoxon signed rank test, analysis of variance). Significant noise reduction was noted at all three levels with the algorithm (P < .05). Reduction in image contrast was noted with only one noise reduction level (P < .0001). The algorithm improves image noise without affecting lesion conspicuity and detection on low-dose abdominal and pelvic CT images.

Adult↗

A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement.

RATIONALE AND OBJECTIVES: To evaluate a newly developed algorithm for metal artifact reduction (MAR) in Computed Tomography (CT). METHODS: A projection interpolation algorithm for MAR with threshold-based metal segmentation was developed. First, the algorithm was tested with a simulated hip phantom. On demand, the presence of metallic inserts was simulated, representing total hip endoprostheses. Second, CT data of 20 patient with total hip endoprosthesis were reconstructed with and without application of the MAR algorithm. Image quality was independently assessed by 2 experienced radiologists using a qualitative score. The results of the in vitro study were evaluated with the Student's t test. Results of the in vivo study were analyzed using a repeated-measure analysis of variance. RESULTS: Applying the MAR algorithm the phantom study showed no significant difference between images with and without simulated metal contributions. The patient study revealed improved image quality using the MAR algorithm. Results were statistically significant for fat (P=0.0097), vessels (P=0.0091), and bone (P=0.0005). Improvement of the image quality for muscle was not statistically significant (P=0.0287). CONCLUSIONS: A new algorithm for metal artifact reduction was successfully introduced into clinical routine. The algorithm led to a robust reduction of metal artifacts. The MAR algorithm may serve for an improvement in image quality in patients with metallic implants.

Aged↗

Spatial domain filtering for fast modification of the tradeoff between image sharpness and pixel noise in computed tomography.

In computed tomography (CT), selection of a convolution kernel determines the tradeoff between image sharpness and pixel noise. For certain clinical applications it is desirable to have two or more sets of images with different settings. So far, this typically requires reconstruction of several sets of images. We present an alternative approach using default reconstruction of sharp images and online filtering in the spatial domain allowing modification of the sharpness-noise tradeoff in real time. A suitable smoothing filter function in the frequency domain is the ratio of smooth and original (sharp) kernel. Efficient implementation can be achieved by a Fourier transform of this ratio to the spatial domain. Separating the two-dimensional spatial filtering into two subsequent one-dimensional filtering stages in the x and y directions using a Gaussian approximation for the convolution kernel further reduces computational complexity. Due to efficient implementation, interactive modification of the filter settings becomes possible, which can completely replace the variety of different reconstruction kernels.

Algorithms↗

Spatial domain image filtering in computed tomography: feasibility study in pulmonary embolism.

Our objective was to evaluate the clinical feasibility of spatial domain filtering as an alternative to additional image reconstruction using different kernels in chest CT. Spatial domain filtering generates smooth images from sharp images and thus avoids the need for additional reconstructions when two sets of images are desired. Forty adult patients with clinical suspicion of pulmonary embolism were examined utilizing multi-slice CT (Somatom Volume Zoom, Siemens, Germany). Derived from thin collimated source images (100 mAs, collimation 4x1 mm, rotation time 0.5 s, table speed 7 mm/rotation), two sets of images [effective slice thickness (S(eff)) 5 mm, reconstruction increment (RI) 5 mm) were generated using lung (Siemens B50) and soft tissue (Siemens B30) kernels. Additionally, B50 images were filtered in the spatial domain, producing images largely equivalent to B30 images. Firstly, diagnostic accuracy was assessed on spatial domain filtered images regarding central, segmental, and subsegmental pulmonary embolism. In a second step, diagnostic accuracy was assessed for the initially reconstructed B30 images. The results were compared with thin axial slices from the same data set, which were considered as the gold standard in this respect (S(eff )1.25 mm, RI 0.8 mm; B30). Initially reconstructed B30 slices and secondary filtered images were rated for subjective image quality, using a five-point scale (1=excellent, 2=good, 3=moderate, 4=poor, 5=non-diagnostic). Finally, quantitative measurements were assessed using the region of interest (ROI) methodology. In 20 patients pulmonary embolism was proven. Five-millimeter images revealed 10 of 10 central emboli, 18 of 19 segmental thrombi, and 18 of 20 emboli on the subsegmental level. Pulmonary embolism was excluded in 18 of 20 subjects, and in 2 patients a false-positive result was obtained in subsegmental arteries. These findings were concordant for reconstructed and filtered images. Quantitative density measurements provided comparable Hounsfield units in this respect. Subjective gradings of image quality, based on soft tissue settings, were 1.30 (+/-0.61) for reconstructed slices vs 1.35 (+/-0.62) for filtered images (weighted kappa coefficient 0.6117; 95% confidence intervals 0.3298-0.8935). Spatial domain filtering has proved to be feasible. Compared with conventional soft tissue reconstructions for central, segmental, and subsegmental pulmonary embolism, no significant difference in the diagnostic value of spatial domain filtered images was found. Online modifications of image sharpness and pixel noise in real time leads to a considerable reduction of processing time and cost saving for storage of CT images. Despite different data processing methods, thin effective slice thicknesses and overlapping reconstruction increments are mandatory for detailed CT analysis of pulmonary embolism on the segmental and subsegmental level.

Feasibility Studies↗