The effect of a microcarrier suspension cell culture system on polarization measurements from Ni-Cr dental casting alloys.

OBJECTIVES: Recent research has demonstrated that cells/cellular components can influence the corrosion or degradation of the implant material in addition to being challenged by the cytotoxic by-products the implant material may release. The overall objective of this research was to modify a microcarrier suspension cell culture system to incorporate an active corrosion experimental capacity. METHODS: The ability to conduct polarization experiments on two Ni-Cr dental casting alloys under the following environmental conditions: media only, media plus serum, media plus serum and antibiotics (complete media), complete media with microcarriers, and complete media with cells grown on microcarriers; was evaluated during this initial study. RESULTS: Results obtained were reproducible within sample groups (95% confidence level) indicating the precision of the corrosion set-up under all environmental conditions. These studies also show that media with serum and antibiotics (complete media) induced a significantly higher corrosion rate (95% confidence level) for both materials compared to the other test conditions. SIGNIFICANCE: Future experiments will focus on cytotoxic effects caused by parametrically controlled corrosion experiments on the suspension cell cultures, including co-cultures.

Adult↗

Magnetic resonance phase velocity mapping through NiTi stents in a flow phantom model.

PURPOSE: To assess constant and pulsatile flow velocity within the lumen of a peripheral NiTi stent using phase velocity mapping for comparison with independent assessments of flow velocity in a phantom model. MATERIALS AND METHODS: A 9 x 20-mm stent installed in flexible tubing was placed in a phantom filled with stationary fluid. Constant and pulsatile flow (produced by a pump programmed to produce a simulation of the carotid artery flow) was assessed using phase velocity mapping at 4.1 T (for constant flow) and at 1.5 T (for pulsatile flow). In all cases 256 x 256 gradient echo phase velocity maps were acquired. For the pulsatile flow condition, cine images with acquisition gated to the pump cycle were acquired with 40 msec temporal resolution across the simulated cardiac cycle. Computed flow volume rates were compared with fluid volume collection for the constant flow model, and with ultrasonic Doppler flow meter measurements for the pulsatile model. RESULTS: The data showed that volume flow rate assessments by phase velocity mapping agreed with independent measurements within 10% to 15%. CONCLUSION: Phase velocity mapping of the lumen of peripheral size NiTi stents is possible in an in vitro model.

Alloys↗

Evaluation of in-stent stenosis by magnetic resonance phase-velocity mapping in nickel-titanium stents.

PURPOSE: To evaluate different grades of in-stent stenosis in a nickel-titanium stent with MRI. MATERIALS AND METHODS: Magnetic resonance phase velocity mapping (MR-PVM) was used to measure flow velocity through a 9-mm NiTi stent with three different degrees of stenosis in a phantom study. The tested stenotic geometries were 1) axisymmetric 75%, 2) axisymmetric 90%, and 3) asymmetric 50%. The MR-PVM data were subsequently compared with the velocities from computational fluid dynamic (CFD) simulations of identical conditions. RESULTS: Good quantitative agreement in velocity distribution for the 50% and 75% stenoses was observed. The agreement was poor for the 90% stenosis, most likely due to turbulence and the high-velocity gradients found in the small luminal area relative to the pixel resolution in our imaging settings. CONCLUSION: The accuracy of the MRI velocities inside the stented area renders MRI a modality that may be used to assess moderate to severe in-stent restenosis (ISR) in medium-sized vascular stents in peripheral vessels, such as the iliac, carotid, and femoral arteries. Advances in MR instrumentation may provide sufficient resolution to obtain adequate velocity information from smaller vessels, such as the coronary arteries, and allow MRI to substitute for invasive and expensive catheterization procedures currently in clinical use.

Constriction, Pathologic↗

Middle infrared, quantum cascade laser optoelectronic absorption system for monitoring glucose in serum.

Advances in middle infrared technology are leading researchers beyond the Fourier transform infrared spectrometer and to the quantum cascade laser. While most research focuses on gas-phase detection, recent research explores its use for condensed-phase matter studies. This work investigates its use for monitoring biologically relevant samples of glucose in serum. Samples with physiological glucose concentrations were monitored with a laser at 1036 cm-1. A 0.992 R2 linearity value was observed. In addition, using another laser at 1194 cm-1 as a measure of the background spectroscopic characteristics, a linearity of 0.998 R2 was observed. The average predictive standard errors of the mean (SEM) were 32.5 and 24.7 mg/dL, respectively, for each method. Quantum cascade lasers could be used to develop middle infrared devices for uses beyond the confines of the laboratory.

Blood Glucose↗

Corrosion on spinal implants.

OBJECTIVE: Modular spine implants are used as an aid to obtaining fusion, but fretting and corrosion occur between modular components in a biologic environment. METHODS: Forty-eight spinal implant constructs manufactured by a variety of companies were retrieved from 47 patients and were subjected to surface analysis stereomicroscopy. RESULTS: Stainless-steel implants (n = 23) had either semirigid constructs with mild or no surface alteration (n = 7) or rigid constructs with moderate or severe alteration (n = 16). Surface damage was consistent with previously observed mechanically assisted crevice corrosion phenomena. Titanium alloy implants (n = 25) showed no significant corrosion but had three constructs with fatigue failure of anchoring screws. One cobalt alloy construct showed no evidence of corrosion. CONCLUSIONS: Long-term effects of fretting and corrosion are unclear, and minimization of these phenomena seems justified. Selection of modular components with similar materials and surface finish may help the surgeon minimize localized changes over time. Stainless-steel implants with rigid interconnections and those with different surface finishes between rods and connectors are most susceptible to corrosion.

Alloys↗

A flow visualization study of an anatomic coronary artery anastomosis model with an implant.

Flow Streamlining Devices is a new tool in Coronary Artery Bypass Grafting (CABG). They aim in: a) Performing a sutureless anastomosis to reduce thrombosis at the veno-arterial junction, and b) Providing a hemodynamically efficient scaffolding to reduce secondary flow disturbances. Thrombosis and flow disturbances are factors that have been reported as contributing factors to the development of intimal hyperplasia (IH) and failure of the graft. By reducing thrombosis and flow disturbances, it is expected that IH will be inhibited and the lifetime of the graft extended. To evaluate the hemodynamic benefits of such an implant, two models were designed and fabricated. One simulated the geometry of the conventional anastomosis without an implant, and the other simulated an anastomosis with a flow streamlining implant. Identical flow conditions relevant to a coronary anastomosis were imposed on both models and flow visualization was performed with dye injection and a digital camera. Results showed reduction of disturbances in the presence of the implant. This reduction seems to be favorable to hemodynamic streamlining which may create conditions that may inhibit the initialization of IH. However, the compliance and geometric mismatch between the anastomosis and the implant created a disturbance at the rigid compliant wall interface, which should be eliminated prior to clinical applications.

Anastomosis, Surgical↗

The hemodynamic effects of compliance, bulging, and curvature in a saphenous vein coronary artery bypass graft model.

The development of Intimal Hyperplasia (IH) in saphenous vein coronary artery bypass grafts (SV-CABG) is responsible for the short-term patency of these grafts. Previous studies of SV-CABG models were performed on rigid anastomotic vessels. However, the effects of compliance, bulging and curvature at the anastomosis on the general hemodynamic field, due to compliance and geometric mismatch between the vein and the artery have not been evaluated. We studied axial and transverse velocities by Laser Doppler Velocimetry on a compliant, in vitro, anatomical model of an end-to-side saphenous vein graft (SVG) to left anterior descending (LAD). The model incorporated a bulge at the sinus and curvature at the graft-host junction. Physiologic pressure and flow conditions pertaining to SV-CABG were applied. The presence of the bulge and curvature showed differences in the velocity profiles in comparison with previous rigid model studies. Dynamic separation zones were temporally augmented at the flow divider. The moving stagnation point at the floor of the host vessel was observed to move past the toe of the model during the accelerating portion of the cycle. These findings suggest that the presence of the bulge curvature and compliance may further favor conditions for the development of intimal hyperplasia (IH) at the floor of a CABG.

Coronary Artery Bypass↗

Comparative MRI compatibility of 316 L stainless steel alloy and nickel-titanium alloy stents.

The initial success of coronary stenting is leading to a proliferation in peripheral stenting. A significant portion of the stents used in a clinical setting are made of 316 low carbon stainless steel (SS). Other alloys that have been used for stent manufacture include tantalum, MP35N, and nickel-titanium (NiTi). The ferromagnetic properties of SS cause the production of artifacts in magnetic resonance imaging (MRI). The NiTi alloys, in addition to being known for their shape memory or superelastic properties, have been shown to exhibit reduced interference in MRI. Thus, the objective of this study was to determine the comparative MRI compatibility of SS and NiTi stents. Both gradient echo and spin-echo images were obtained at 1.5 and 4.1 T field strengths. The imaging of stents of identical geometry but differing compositions permitted the quantification of artifacts produced due to device composition by normalizing the radio frequency shielding effects. These images were analyzed for magnitude and spatial extent of signal loss within the lumen and outside the stent. B1 mapping was used to quantify the attenuation throughout the image. The SS stent caused significant signal loss and did not allow for visibility of the lumen. However, the NiTi stent caused only minor artifacting and even allowed for visualization of the signal from within the lumen. In addition, adjustments to the flip angle of standard imaging protocols were shown to improve the quality of signal from within the lumen.

Alloys↗

Using two discrete frequencies within the middle infrared to quantitatively determine glucose in serum.

Tight glucose monitoring is essential for the reduction of diabetic complications. This research investigated the changes of absorption spectra observed in serum at three prominent glucose absorption peaks in the middle infrared using a demountable liquid, transmission cell. Two frequencies of light were used to determine the glucose absorption: one at 1193 cm(-1 ) to determine the background water absorption and the other at one of the characteristic peaks (1035, 1080, and 1109 cm(-1)). The peak at 1035 cm(-1) was best for quantitative determination with a standard of error of 20.6 mg/dl (1.1 mmol/L). While interference from other serum constituents could cause problems, urea and albumin-two constituents known to have close absorption peaks-were determined to have no effect on the ability to determine the glucose levels at 1035 cm( -1).

Blood Chemical Analysis↗

Effect of a flow-streamlining implant at the distal anastomosis of a coronary artery bypass graft.

Intimal thickening in the coronary artery bypass graft (CABG) distal anastomosis has been implicated as the major cause of restenosis and long-term graft failure. Several studies point to the interplay between nonuniform hemodynamics including disturbed flows and recirculation zones, wall shear stress, and long particle residence time as possible etiologies. The hemodynamic features of two anatomic models of saphenous-vein CABGs were studied and compared. One simulated an anastomosis with both diameter and compliance mismatch and a curvature at the connection, analogous to the geometry observed in a conventional cardiothoracic procedure. The other, simulated an anastomosis with a flow stabilizing anastomotic implant connector which improves current cardiothoracic procedures by eliminating the distal vein bulging and curvature. Physiologic flow conditions were imposed on both models and qualitative analysis of the flow was performed with dye injection and a digital camera. Quantitative analysis was performed with laser Doppler velocimetry. Results showed that the presence of the bulge at the veno-arterial junction, contributed to the formation of accentuated secondary structures (helices), which progress into the flow divider and significantly affect radial velocity components at the host vessel up to four diameters downstream of the junction. The model with the implant, achieved more hemodynamically efficient conditions on the host vessel with higher mean and maximum axial velocities and lower radial velocities than the conventional model. The presence of the sinus may also affect the magnitude and shape of the shear stress at locations where intimal thickening occurs. Thus, the presence of the implant creates a more streamlined environment with more primary and less secondary flow components which may then inhibit the development of intimal thickening, restenosis, and ultimate failure of the saphenous vein graft.

Arteriovenous Anastomosis↗

Hemoglobin adsorption isotherm at the silica-water interface with evanescent wave cavity ring-down spectroscopy.

Evanescent wave cavity ring-down spectroscopy (EW-CRDS) is used to observe the adsorption isotherm for hemoglobin (Hb) from controlled urine samples to assess the potential for rapid diagnosis in hemoglobinuria. The absorbance of Hb at 425 nm is monitored using an alexandrite laser-pumped, room temperature, LiF:F2+** color-center pulsed laser. A minimum absorbance detection level of 2.57 x 10(-4) is achieved, corresponding to a minimum detectable concentration of Hb in urea of 5.8 nM. A multilayered Hb biofilm is formed, and a minimum of eight layers are required to model the adsorption isotherm, allowing for cooperative binding within the layers and extending 56 nm into the interface. A binding constant for Hb to silica 18.23+/-7.58 x 10(6) M is derived, and a binding constant for Hb to Hb in subsequent layers is determined to be 5.631+/-0.432 x 10(5) M. Stoichiometric binding coefficients of 1.530+/-0.981 for layer one and 1.792+/-0.162 for subsequent layers suggest that cooperative binding both to the silica surface and between the layers of the biofilm is important.

Adsorption↗

Nanostructured ceramics for biomedical implants.

Recent progress in the synthesis, characterization, and biological compatibility of nanostructured ceramics for biomedical implants is reviewed. A major goal is to develop ceramic coating technology that can reduce the friction and wear in mating total joint replacement components, thus contributing to their significantly improved function and longer life span. Particular attention is focused on the enhancement of mechanical properties such as hardness, toughness, and friction coefficient and on the bioactivity as they pertain to the nanostructure of the material. The development of three nanostructured implant coatings is discussed: diamond, hydroxyapatite, and functionally graded metalloceramics based on the Cr-Ti-N ternary system. Nanostructured diamond produced by chemical vapor deposition (CVD) techniques and composed of nano-size diamond grains have particular promise because of the combination of ultrahigh hardness, improved toughness over conventional microcrystalline diamond, low friction, and good adhesion to titanium alloys. Nanostructured processing applied to hydroxyapatite coatings is used to achieve the desired mechanical characteristics and enhanced surface reactivity and has been found to increase osteoblast adhesion, proliferation, and mineralization. Finally, nanostructured metalloceramic coatings provide continuous variation from a nanocrystalline metallic bond at the interface to the hard ceramic bond on the surface and have the ability to overcome adhesion problems associated with ceramic hard coatings on metallic substrates.