Microchip capillary electrophoresis for point-of-care analysis of lithium.

BACKGROUND: Microchip capillary electrophoresis (CE) is a promising method for chemical analysis of complex samples such as whole blood. We evaluated the method for point-of-care testing of lithium. METHODS: Chemical separation was performed on standard glass microchip CE devices with a conductivity detector as described in previous work. Here we demonstrate a new sample-to-chip interface. Initially, we took a glass capillary as a sample collector for whole blood from a finger stick. In addition, we designed a novel disposable sample collector and tested it against the clinical standard at the hospital (Medisch Spectrum Twente). Both types of collectors require < 10 microL of test fluid. The collectors contain an integrated filter membrane, which prevents the transfer of blood cells into the microchip. The combination of such a sample collector with microchip CE allows point-of-care measurements without the need for off-chip sample treatment. This new on-chip protocol was verified against routine lithium testing of 5 patients in the hospital. RESULTS: Sodium, lithium, magnesium, and calcium were separated in < 20 s. The detection limit for lithium was 0.15 mmol/L. CONCLUSIONS: The new microchip CE system provides a convenient and rapid method for point-of-care testing of electrolytes in serum and whole blood.

Antimanic Agents↗

Viability study of HL60 cells in contact with commonly used microchip materials.

This paper presents a study in which different commonly used microchip materials (silicon oxide, borosilicate glass, and PDMS) were analyzed for their effect on human promyelocytic leukemic (HL60) cells. Copper-coated silicon was analyzed for its toxicity and therefore served as a positive control. With quantitative PCR, the expression of the proliferation marker Cyclin D1 and the apoptosis marker tissue transglutaminase were measured. Flow cytometry was used to analyze the distribution through the different phases of the cell cycle (propidium iodide, PI) and the apoptotic cascade (Annexin V in combination with PI). All microchip materials, with the exception of Cu, appeared to be suitable for HL60 cells, showing a ratio apoptosis/proliferation (R(ap)) comparable to materials used in conventional cell culture (polystyrene). These results were confirmed with cell cycle analysis and apoptosis studies. Precoating the microchip material surfaces with serum favor the proliferation, as demonstrated by a lower R(ap) as compared to uncoated surfaces. The Cu-coated surface appeared to be toxic for HL60 cells, showing over 90% decreased viability within 24 h. From these results, it can be concluded that the chosen protocol is suitable for selection of the cell culture material, and that the most commonly used microchip materials are compatible with HL60 culturing.

Apoptosis↗

Rapid inorganic ion analysis using quantitative microchip capillary electrophoresis.

Rapid quantitative microchip capillary electrophoresis (CE) for online monitoring of drinking water enabling inorganic ion separation in less than 15 s is presented. Comparing cationic and anionic standards at different concentrations the analysis of cationic species resulted in non-linear calibration curves. We interpret this effect as a variation in the volume of the injected sample plug caused by changes of the electroosmotic flow (EOF) due to the strong interaction of bivalent cations with the glass surface. This explanation is supported by the observation of severe peak tailing. Conducting microchip CE analysis in a glass microchannel, optimized conditions are received for the cationic species K+, Na+, Ca2+, Mg2+ using a background electrolyte consisting of 30 mmol/L histidine and 2-(N-morpholino)ethanesulfonic acid, containing 0.5 mmol/L potassium chloride to reduce surface interaction and 4 mmol/L tartaric acid as a complexing agent resulting in a pH-value of 5.8. Applying reversed EOF co-migration for the anionic species Cl-, SO42- and HCO3- optimized separation occurs in a background electrolyte consisting of 10 mmol/L 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) and 10 mmol/L HEPES sodium salt, containing 0.05 mmol/L CTAB (cetyltrimethylammonium bromide) resulting in a pH-value of 7.5. The detection limits are 20 micromol/L for the monovalent cationic and anionic species and 10 micromol/L for the divalent species. These values make the method very suitable for many applications including the analysis of abundant ions in tap water as demonstrated in this paper.

Electrophoresis, Microchip↗

A new pulsed electric field microreactor: comparison between the laboratory and microtechnology scale.

This paper presents a new microreactor dedicated for pulsed electric field treatment (PEF), which is a pasteurization method that inactivates microorganisms with short electric pulses. The PEF microreactor consists of a flow-through channel with a constriction where the electric field is focussed. Compared to a laboratory-scale setup 25 times lower voltages were needed to obtain the same electric field strength due to the close electrode spacing. A finite element model showed that the electric field intensity is very homogeneous throughout the channel, which is crucial for the pasteurization processes. Experiments where artificial vesicles, loaded with carboxyfluorescein, were electroporated showed that the maximum transmembrane potential adequately described the processes both in the microreactor and the laboratory-scale setup, although the length scales are different. Electroporation started at a transmembrane potential of 0.5 V, reaching a maximum fraction of electroporated vesicles of 51% at a transmembrane potential of 1.5 V. The partial electroporation is not a result of the heterogenity of the vesicles or the electric field. With this new PEF microreactor it is possible to study the PEF process in more detail.

Bacteria↗

Microchip analysis of lithium in blood using moving boundary electrophoresis and zone electrophoresis.

The determination of inorganic cations in blood plasma is demonstrated using a combination of moving boundary electrophoresis (MBE) and zone electrophoresis. The sample loading performed under MBE conditions is studied with the focus on the quantitative analysis of lithium. A concentration adjustment takes place when the sample components migrate into the chip during the sample loading step. Using a heart-cutting method, a diluted sample plug is subsequently separated with capillary zone electrophoresis. The excessive dispersion that is typical of the samples with a high ionic strength is thereby prevented. The method can be easily applied to commercially available capillary electrophoresis microchips under the condition that the electroosmotic flow is suppressed. For the first time the lithium concentration is determined in the blood plasma from a patient on lithium therapy without sample pretreatment. Using a microchip with conductivity detection, a detection limit of 0.1 mmol/L is obtained for lithium in a 140 mmol/L sodium matrix.

Electric Conductivity↗

Apoptotic cell death dynamics of HL60 cells studied using a microfluidic cell trap device.

This paper presents the design, fabrication and first results of a microfluidic cell trap device for analysis of apoptosis. The microfluidic silicon-glass chip enables the immobilization of cells and real-time monitoring of the apoptotic process. Induction of apoptosis, either electric field mediated or chemically induced with tumour necrosis factor (TNF-alpha), in combination with cycloheximide (CHX), was addressed. Exposure of cells to the appropriate fluorescent dyes, FLICA and PI, allows one to discriminate between viable, apoptotic and necrotic cells. The results showed that the onset of apoptosis and the transitions during the course of the cell death cascade were followed in chemically induced apoptotic HL60 cells. For the case of electric field mediated cell death, the distinction between apoptotic and necrotic stage was not clear. This paper presents the first results to analyse programmed cell death dynamics using this apoptosis chip and a first step towards an integrated apoptosis chip for high-throughput drug screening on a single cellular level.

Apoptosis↗

Direct measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection.

The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.

Acrylic Resins↗

Comparison of capillary zone electrophoresis performance of powder-blasted and hydrogen fluoride-etched microchannels in glass.

The applicability of glass chips with powder-blasted microchannels for electrophoretic separations was examined, and the performance was compared to microchannels etched with hydrogen fluoride (HF), using bicarbonate buffer and rhodamine B and fluorescein as model compounds. The measured electroosmotic mobilities in all chips were comparable, with values of ca. 7 x 10(-4) cm(2) V(-1)s(-1). The effect of electrical field strength and detection length on the separation efficiency was monitored. It was found that the main source of dispersion is of the Taylor-Aris type, which was discussed in relation to channel roughness differences. Although in powder-blasted channels with a separation length of 8.20 cm, 7-9 times lower plate numbers were obtained than in a HF-etched channel with similar dimensions, successful separation of five fluorescein isothiocyanate (FITC)-labeled amino acids was obtained on a powder-blasted chip within 80 s. Efficiencies of up to 360 000 plates/m were demonstrated on this chip, when a higher buffer concentration was used at a field strength of 664 V/cm. It can be concluded that powder-blasted microchannel chips, although they have a lower separation efficiency compared to HF-etched chips, perform well enough for many applications. Powder blasting can therefore be considered a low-cost and efficient alternative to HF etching, in particular because of the possibility to fabricate access holes through the glass with the same process.

Amino Acids↗