PubMed Health⌕ Search

Biomedical subjects

Rene Hornung

Publications and source records attributed to Rene Hornung.

2 recordsLinked to original sources

Fluorescence hysteroscopy using 5-aminolevulinic: a descriptive study.

BACKGROUND AND OBJECTIVES: To assess the feasibility of fluorescence hysteroscopy following topical ALA application and to describe the optical appearance of normal and neoplastic endometrium. STUDY DESIGN/MATERIALS AND METHODS: Fifty-four patients scheduled for routine hysteroscopy and D&C were assigned to the study group using topically applied ALA. Two milliliters of a 2% 5-ALA-solution at pH = 4.0 (ASAT AG/Zug, Switzerland) was administrated into the uterine cavity 4 hours before fluorescence hysteroscopy, using a STORZ-D-Light (Tuttlingen, Germany) system. Hysteroscopic findings were compared to the histological diagnosis of hematoxylin & eosin (H&E) stained sections. In the study group, 60 histological specimens were taken (47 materials of curettage and 13 targeted biopsies). The percentage of fluorescence positive patients was calculated. RESULTS: The rate of fluorescent endometrial samples was low in atrophic endometrium 1/16 (6.2%). Endometrial carcinoma were diagnosed in two patients. Both cases exhibited selective and intense PpIX-mediated red fluorescence. Fluorescence hysteroscopy could not differentiate between hyperplastic areas with or without atypia. Minimal uterine cramps or discomfort following ALA instillation were complained by 30 (56%) patients, no pain was indicated by 24 patients (44%). CONCLUSIONS: Fluorescence hysteroscopy following intrauterine application of ALA is feasible. Cancerous, hyperplastic, and secretory endometrial tissue showed high red fluorescence.

Administration, Topical↗

Axillary staging using positron emission tomography in breast cancer patients qualifying for sentinel lymph node biopsy.

Axillary lymph node dissection (ALND) is the standard of care for nodal staging of patients with invasive breast cancer. Due to significant somatic and psychological side effects, replacement of ALND with less invasive techniques is desirable. The goal of this study was to evaluate the clinical usefulness of axillary lymph node (ALN) staging by means of positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG) in breast cancer patients qualifying for sentinel lymph node biopsy (SLNB). FDG-PET was performed within 1 week before surgery in 24 clinically node-negative breast cancer patients with tumors smaller than 3 cm. Sentinel lymph nodes (SLNs) were identified by preoperative lymphoscintigraphy following peritumoral technetium 99m-labeled colloid albumin injection, and by intraoperative gamma detector and blue dye localization. Following SLNB, a standard ALND was performed. Serial sectioning and immunohistochemistry of the SLN as well as standard histologic examination of the non-SLN was performed. FDG-PET detected all primary breast cancers. Staging of ALNs by PET was accurate in 15 of 24 patients (62.5%), whereas PET staging was false negative in 8 of 10 node-positive patients and false-positive in 1 patient. The sensitivity, specificity, positive predictive value, and negative predictive value of FDG-PET for nodal status was 20%, 93%, 67%, and 62%, respectively. The mean diameter of false-negative ALN metastases was 7.5 mm (range 1-15 mm). Lymph node staging using FDG-PET is not accurate enough in clinically node-negative patients with breast cancer qualifying for SLNB and should not be used for this purpose.

Adult↗