Contact pressures at grafted cartilage lesions in the knee.

The use of tissue-engineered cellular constructs is currently under clinical evaluation for the surgical treatment of articular cartilage lesions in the knee. The primary failure mode in such cartilage repair techniques is related to fixation. In addition, the repair tissue is believed to be very fragile in the post-operative period, and unable to support the intra-articular loads. We have developed a laboratory testing protocol in order to quantify the contact pressure distribution that develops on fibrin glue grafts applied to full-thickness cartilage lesions. The contact pressure distribution has been mapped on the contact surface of specimens subject to compression, in three configurations (intact, defect and grafted), at increasing load levels. All the maps show stress concentrations at the rim of the defect and a more uniform stress distribution around the rim after defect grafting. At a contact load of 180 N, the peak contact pressure measured on cartilage is 2.5 MPa. In presence of the graft, the peak pressures on the cartilage area surrounding the defect are reduced by 16%, on average. In contrast, both the mean contact pressure on the graft and the graft's contact area increase. The graft was found to carry around 80% of the total applied contact load, at all load levels tested. Fibrin glue was chosen as a grafting material in our study because it shows material properties very representative of currently-implanted cellular constructs. Thus, the results of this study have quantified aspects of recipient graft sites that may assist in optimising such grafting procedures from a biomechanical point of view.

Animals↗

Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations.

The evaluation of contact areas and pressures in total knee prosthesis is a key issue to prevent early failure. The first part of this study is based on the hypothesis that the patterns of contact stresses on the tibial insert of a knee prosthesis at different stages of the gait cycle could be an indicator of the wear performances of a knee prosthesis. Contact stresses were calculated for a mobile bearing knee prosthesis by means of finite element method (FEM). Contact areas and stresses were also measured through in vitro tests using Fuji Prescale film in order to support the FEM findings. The second part of this study addresses the long-term structural integrity of metal tibial components in terms of fatigue life by means of experimental tests and FEM simulations. Fatigue experimental evaluations were performed on Cr-Co alloy tibial tray, based on ISO standards. FEM models were used to calculate the stress patterns. The failure risk was estimated with a standard fatigue criterion on the basis of the results obtained from the FEM calculations. Experimental and computational results showed a positive matching.

Computer Simulation↗

Behavior of the bone-titanium interface after push-in testing: a morphological study.

Fourteen titanium dental implants (Tioblast) were implanted singly in the proximal tibia of New Zealand rabbits for 120 days. A bone defect was surgically produced and filled with Bio-Oss around six of these implants. After the animals were sacrificed and their organs harvested, bone segments were fixed and methacrylate embedded after the push-in test had been performed. Microradiography was performed on longitudinal sections of the implants, whereas scanning electron microscope analysis was performed on the remaining embedded half-implants using secondary electrons only. The results showed that the implants were apically and coronally surrounded by bone, whether Bio-Oss was used or not. Fractures were evident through the newly formed bone and between the pre-existing and newly formed bone. Some fracture lines propagated through the bone and stopped at the implant surface without continuing along the bone-titanium interface. Detachment between the implant and the bone occurred at the coronal extremity of the implants and along its cervical region. These results highlight the fact that the bone-titanium interface has a high resistance to loading. It exhibited greater resistance than the newly formed bone and seems to behave in a manner similar to the cement lines of osteons.

Animals↗

Mechanical behavior of coronary stents investigated through the finite element method.

Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent is mounted on a balloon catheter and delivered to the site of blockage. When the balloon is inflated, the stent expands and is pressed against the inner wall of the coronary artery. After the balloon is deflated and removed, the stent remains in place, keeping the artery open. Hence, the stent expansion defines the effectiveness of the surgical procedure: it depends on the stent geometry, it includes large displacements and deformations and material non-linearity. In this paper, the finite element method is applied (i) to understand the effects of different geometrical parameters (thickness, metal-to-artery surface ratio, longitudinal and radial cut lengths) of a typical diamond-shaped coronary stent on the device mechanical performance, (ii) to compare the response of different actual stent models when loaded by internal pressure and (iii) to collect suggestions for optimizing the device shape and performance. The stent expansion and partial recoil under balloon inflation and deflation were simulated. Results showed the influence of the geometry on the stent behavior: a stent with a low metal-to-artery surface ratio has a higher radial and longitudinal recoil, but a lower dogboning. The thickness influences the stent performance in terms of foreshortening, longitudinal recoil and dogboning. In conclusion, a finite element analysis similar to the one herewith proposed could help in designing new stents or analyzing actual stents to ensure ideal expansion and structural integrity, substituting in vitro experiments often difficult and unpractical.

Computer Simulation↗

Experimental procedure for the evaluation of the mechanical properties of the bone surrounding dental implants.

The mechanical stability of the fixture in bone is one of the most important factors for the long-term reliability of dental implants. This paper focuses on an experimental procedure to evaluate the mechanical properties of the bone surrounding dental implants. The procedure is based on a surgical animal model followed by mechanical tests. The experimental mechanical testing has been used for preliminary investigations on the role played by different parameters such as the healing time and the surgical technique (standard or with regenerative material). The procedure has been evaluated in some preliminary tests on a few specimens. Microradiographic analyses have been performed on the bone surrounding the implants in order to give an interpretation of the bone properties on the basis of the bone morphology and to distinguish the newly formed bone from the pre-existing bone. The preliminary results relevant to 10 threaded titanium implants are presented and discussed. Our findings show that the mechanical properties of the bone surrounding the implant improve with the increase in the healing time from 24 to 45 days. The ultimate loads recorded during mechanical tests arise from 395 N to 2665 N in case of coronal defects filled with bone regenerative and from 2200 N to 5700 N in case of standard technique.

Animals↗

An in vitro methodology for evaluating the mechanical properties of aortic vascular prostheses.

The main problem in the replacement of pathological segments of the aorta with vascular prostheses consists of matching the fluid admittance of the host artery and the graft. This mismatch results from the different compliance between natural and prosthetic vessels and from the plastic dilatation of the prosthesis diameter that occurs after implantation. An experimental procedure was set up for evaluating the mechanical properties of aortic vascular prostheses. An MTS 858 MiniBionix testing machine was equipped with a purposely designed testing apparatus, which allows loading a ring-shaped prosthesis specimen with forces that can be related easily to the transmural pressure acting on the prostheses in vivo. The reference pressure waveforms are simulated from a lumped parameter model of the cardiovascular system. Preliminary tests on 3 different (woven, warp knitted, and carbon-coated warp knitted fabric) aortic prostheses point out a good reproducibility of the results. The fabric strongly affects the circumferential elasticity and the dimensional stability of the graft. Simulation of hypertension promotes larger diameter dilatation and reduction in compliance. Agreement between in vitro and clinical diameter measurements has been assessed for 8 prosthesis samples and found to be adequate. This method is thus a potentially useful means for preclinical evaluation of compliance of vascular prostheses for the purpose of matching to native vessels.

Aged↗

Quantitative approach for the prediction of tooth movement during orthodontic treatment.

The orthodontic treatment is aimed to displace and/or rotate the teeth to obtain the functionally correct occlusion and the best aesthetics and consists in applying forces and/or couples to tooth crowns. The applied loads are generated by the elastic recovery of metallic wires linked to the tooth crowns by brackets. These loads generate a stress state into the periodontal ligament and hence, in the alveolar bone, causing the bone remodeling responsible for the tooth movement. The orthodontic appliance is usually designed on the basis of the clinical experience of the orthodontist. In this work, a quantitative approach for the prediction of the tooth movement is presented that has been developed as a first step to build up a computer tool to aid the orthodontist in designing the orthodontic appliance. The model calculates the tooth movement through time with respect to a fixed Cartesian frame located in the middle of the dental arch. The user interface panel has been designed to allow the orthodontist to manage the standard geometrical references and parameters usually adopted to design the treatment. Simulations of specific cases are reported for which the parameters of the model are selected in order to reproduce forecasts of tooth movement matching data published in experimental works.

Animals↗

Pressure drops in a distensible model of end-to-side anastomosis in systemic-to-pulmonary shunts.

The modified Blalock-Taussig shunt is a surgical procedure used as a palliation to treat complex congenital heart defects. It consists of an interposing prosthetic tube between the innominate/subclavian artery and the right pulmonary artery. Previous experience indicates that the pressure drop across the shunt is affected by the pulmonary pressure at the distal anastomosis combined with the distensibility of the anastomosis. In this study, a computational fluid-structure interaction approach is presented to investigate the haemodynamic behaviour. Steady-state fluid dynamics and structural analyses were carried out using commercial codes based on the finite element method (FIDAP and ABAQUS) coupled by means of a purposely-developed procedure to transfer boundary conditions. Both prosthetic tube and artery walls were characterised by non-linear material properties. Three different pulmonary pressures (2, 5 and 15 mmHg) and two volume flow rates (0.4 and 0.8 l/min) were investigated. Results indicate that the effects of distensibility at the distal anastomosis on the shunt pressure drop are relevant only when the distal anastomosis on the shunt pressure drop are relevant only when the distal anastomosis is not fully distended, which occurs when the pulmonary pressure is lower than 5 mmHg.

Algorithms↗

The effect of fixture neck design in a realistic model of dental implant: a finite element approach.

The aim of this work is to develop an accurate finite element model able to reproduce a standard experimental set-up for the evaluation of mechanical failure of a dental implant system. The considered system is composed of a fixture, an abutment and a connecting screw. We analysed the behaviour of the implant system considering three different designs of the fixture, in order to establish which one provides the better mechanical behaviour. After the definition of the numerical models, loading conditions were selected in order to reproduce the same stress state found in previous mechanical failure tests. Preloading and functional loading conditions were simulated. The analysis of the numerical results shows that the structure yielding is due to the fixture neck plastic deformation, that increases the load eccentricity and then the bending stress on the connecting screw. Only slight differences were found between the three implant systems in the amount and distribution of stress. The model reproduces properly the implant systems and the experimental set-up. The goodness of the model can be summarised as: realistic geometrical structure, elastoplastic model for the material description, correct definition of the contacts and the existing tolerance among the different system components, reproduction of the preloading stress condition. The present study permitted to define a valid procedure for the realization of numerical models of implant systems.

Computer Simulation↗

The effect of hydrodynamic shear on 3D engineered chondrocyte systems subject to direct perfusion.

Bioreactors allowing direct-perfusion of culture medium through tissue-engineered constructs may overcome diffusion limitations associated with static culturing, and may provide flow-mediated mechanical stimuli. The hydrodynamic stress imposed on cells within scaffolds is directly dependent on scaffold microstructure and on bioreactor configuration. Aim of this study is to investigate optimal shear stress ranges and to quantitatively predict the levels of hydrodynamic shear imposed to cells during the experiments. Bovine articular chondrocytes were seeded on polyestherurethane foams and cultured for 2 weeks in a direct perfusion bioreactor designed to impose 4 different values of shear level at a single flow rate (0.5 ml/min). Computational fluid dynamics (CFD) simulations were carried out on reconstructions of the scaffold obtained from micro-computed tomography images. Biochemistry analyses for DNA and sGAG were performed, along with electron microscopy. The hydrodynamic shear induced on cells within constructs, as estimated by CFD simulations, ranged from 4.6 to 56 mPa. This 12-fold increase in the level of applied shear stress determined a 1.7-fold increase in the mean content in DNA and a 2.9-fold increase in the mean content in sGAG. In contrast, the mean sGAG/DNA ratio showed a tendency to decrease for increasing shear levels. Our results suggest that the optimal condition to favour sGAG synthesis in engineered constructs, at least at the beginning of culture, is direct perfusion at the lowest level of hydrodynamic shear. In conclusion, the presented results represent a first attempt to quantitatively correlate the imposed hydrodynamic shear level and the invoked biosynthetic response in 3D engineered chondrocyte systems.

Animals↗