PubMed Health⌕ Search

Biomedical subjects

Richard Knochenmuss

Publications and source records attributed to Richard Knochenmuss.

13 recordsLinked to original sources

Ion formation mechanisms in UV-MALDI.

Matrix Assisted Laser Desorption/Ionization (MALDI) is a very widely used analytical method, but has been developed in a highly empirical manner. Deeper understanding of ionization mechanisms could help to design better methods and improve interpretation of mass spectra. This review summarizes current mechanistic thinking, with emphasis on the most common MALDI variant using ultraviolet laser excitation. A two-step framework is gaining acceptance as a useful model for many MALDI experiments. The steps are primary ionization during or shortly after the laser pulse, followed by secondary reactions in the expanding plume of desorbed material. Primary ionization in UV-MALDI remains somewhat controversial, the two main approaches are the cluster and pooling/photoionization models. Secondary events are less contentious, ion-molecule reaction thermodynamics and kinetics are often invoked, but details differ. To the extent that local thermal equilibrium is approached in the plume, the mass spectra may be straightforwardly interpreted in terms of charge transfer thermodynamics.

Ions↗

Enhanced MALDI ionization efficiency at the metal-matrix interface: practical and mechanistic consequences of sample thickness and preparation method.

Electrosprayed spots of varying thickness were evaluated for use as reproducible, homogenous, high efficiency MALDI samples. Thin samples on stainless steel plates were found to give exceptionally strong signals, as did the last layers of thick samples, when ablated down to the steel substrate. A small enhancement was also observed for thin samples on a gold substrate, and with a few-nanometer gold coating on top of a thick sample. Ion yields and intensity ratios can be understood in the context of the previously described quantitative MALDI model including the matrix-metal interfacial ionization potential reduction effect (Knochenmuss, R.; Anal. Chem. 2004, 76, 3179-3184). The absolute and relative stabilities of ion signals were found to be at least a factor of two better for the thin electrosprayed spots, compared to spots prepared by dried droplet methods.

Animals↗

Recombinant antibodies for the depletion of abundant proteins from human serum.

The identification of biomarkers from serum or plasma is often hindered by a few proteins present at high concentrations, which may obscure less abundant proteins. Ideal serum depletion strategies would be flexible as regards the proteins to be removed, and would feature the use of reagents with long shelf-lives. In this article, we describe a novel protein depletion methodology based on the incubation of serum samples with phage-derived recombinant antibody fragments, which are able to bind to staphylococcal Protein A, and which carry a C-terminal peptide tag capable of streptavidin binding. The resulting protein-antibody complexes can be removed by simultaneous capture on Protein A and/or streptavidin resin. The depletion methodology was exemplified by the isolation of recombinant human mAb fragments specific to abundant human serum Ags and by the simultaneous depletion of albumin, immunoglobulins, alpha2-macroglobulin, hemoglobin, transferrin and haptoglobin. The depleted serum samples were analyzed by 2-DE and by gel-free MS-based methodologies, confirming the efficiency and selectivity of the depletion process. The methodology presented is modular in nature, since several recombinant antibodies can be combined in a single depletion experiment. Furthermore, antibodies do not have to be covalently coupled to a solid support facilitating long-term storage.

Antibodies↗

MALDI MS imaging of amyloid.

Label-free molecular imaging by mass spectrometry allows simultaneous mapping of multiple analytes in biological tissue sections. In this chapter, the application of this new technology to the detection Abeta peptides in mouse brain sections is discussed.

Amyloid↗

Molecular dynamics model of ultraviolet matrix-assisted laser desorption/ionization including ionization processes.

A molecular dynamics model of UV-MALDI including ionization processes is presented. In addition to the previously described breathing sphere approach developed for simulation of laser ablation/desorption of molecular systems, it includes radiative and nonradiative decay, exciton hopping, two pooling processes, and electron capture. The results confirm the main conclusions of the continuum model of Knochenmuss, Anal. Chem. 2003, 75, 2199, but provide a much more detailed description of the interaction between ablation/desorption and ionization processes in the critical early time regime. Both desorption and ablation regimes generate free ions, and yields are in accordance with experiment. The first molecular ions are emitted at high velocities shortly before neutral desorption begins, because of surface charging caused by electron escape from the top of the sample. Later ions are entrained and thermalized in the plume of neutral molecules and clusters. Clusters are found to be stable on a nanosecond time scale, so the ions in them will be released only slowly, if at all. Exciton hopping rate and the mean radius for ion recombination are shown to be key parameters that can have a significant effect on net ion yield.

Ions↗

Spatial and spectral correlations in MALDI mass spectrometry images by clustering and multivariate analysis.

Matrix-assisted laser desorption/ionization mass spectrometry imaging is a technique for direct analysis of tissue sections without the use of molecular tags or contrast agents. The combination of spatial and mass resolution results in large and complex data sets that require powerful and efficient analysis and interpretation tools. Conventional images, derived from a specific analyte mass, do not identify the spatially localized correlations between analytes that are latent in the data. A new approach to find and visualize these correlations is presented. Clustering methods are used to classify pixels by spectral similarity, facilitating definition of distinct spatial regions. Principal component and discriminant analyses are combined to comprehensively identify changes in the mass spectra between regions. Images are generated by projecting the spectra of each pixel on the discriminant spectra; contrast is then a function of multiple correlated peaks.

Algorithms↗

Exciton mobility and trapping in a MALDI matrix.

Energy transfer (ET) from excited matrix to fluorescent traps is used to probe the mobility of excitations in the matrix-assisted laser desorption/ionization (MALDI) matrix material 2,5-dihydroxybenzoic acid. The dependence of host and guest fluorescence on excitation density (laser intensity) and trap concentration gives clear evidence for long-range energy transport in this matrix. This conclusion is further supported by time-resolved emission data showing a 2 ns delay between matrix and trap emission. Rate equation and random walker models give good agreement with the data, allowing determination of hopping, collision, and trapping parameters. Long-range energy transfer contributes to the pooling reactions which can lead to primary ions in MALDI. The results validate the pooling aspect of the prior quantitative MALDI ionization model (J. Mass Spectrom. 2002, 37, 867-877). It is shown that exciton trapping can decrease MALDI ion yield, even at low trap concentration.

Gentisates↗

FT-ICR mass spectrometry in the drug discovery process.

The high mass accuracy and resolution of Fourier transform (FT)-ion cyclotron resonance (ICR) mass spectrometry are making it an increasingly useful tool in drug discovery and development. The basics of FT-ICR are described here, including modern ion sources and fragmentation methods. Although FT-ICR is not a high-throughput method in the traditional sense, previously difficult and complex problems are being efficiently approached using steadily improving instruments and magnets. Applications are surveyed in fields such as proteomics, metabonomics, natural product analysis and non-covalent complexes.

Chemistry, Pharmaceutical↗

Small-molecule MALDI using the matrix suppression effect to reduce or eliminate matrix background interferences.

The matrix suppression effect (MSE) can lead to high-quality MALDI mass spectra: strong analyte signals and weak or negligible matrix background peaks. Experiment and theory suggest that MSE should be widespread and, therefore, generally applicable to measurement of low molecular weight (LMW) substances. These are otherwise impractical with MALDI due to interference from matrix. Appropriate conditions for MSE were investigated and tested on a variety of LMW substances. Straightforward and semiautomated interpretation was possible for 87.7% of these. Another 3.5% gave poor MSE due to sodium cationization rather than protonation of the analyte, but interpretation was possible. MALDI imaging shows that MSE varies significantly across a typical sample. Selective data accumulation could further increase the utility of the method. Samples containing more than one analyte were also studied. Analyte-analyte suppression was not found to be excessive, and moderately abundant minority species can be adequately detected.

Molecular Weight↗

Photoionization pathways and free electrons in UV-MALDI.

The recently developed model for primary and secondary UV-MALDI ion formation (Knochenmuss, R. J. Mass Spectrom. 2002, 37, 867-877. Knochenmuss, R. Anal. Chem. 2003, 75, 2199.) is applied to questions regarding photoionization pathways and electron versus negative ion production. Two-photon ionization of the matrix in direct contact with analyte is possible under some circumstances (Kinsel, G.; Knochenmuss, R.; Setz, P.; Land, C. M.; Goh, S.-K.; Archibong, E. F.; Hardesty, J. H.; Marynik, D. J. Mass Spectrom. 2002, 37, 1131-1140.), and is added to the model. When analyte is present in large mole ratios (such as when matrix suppression is desired), this effect contributes modestly to the ion yield. Generally, matrix exciton pooling remains dominant. The interfacial layer of thin samples on a metal substrate may also be ionizable in a 2-photon process. A mechanism is proposed, and the correspondingly modified model gives excellent agreement with electron emission versus laser intensity data. Capture in, or escape of low-energy electrons from a thick sample (or on a nonmetallic substrate) is also examined. Because the mean free path for MALDI electrons in a solid matrix is on the order of 10 nm, below such depths, any electrons generated are captured to form negative ions. Only a surface layer can emit free electrons. This surface emission effect is also well reproduced by the model, up to a laser intensity limit caused by surface charging. This charging phenomenon is investigated and illustrated by molecular dynamics calculations.

Journal Article↗

A quantitative model of ultraviolet matrix-assisted laser desorption/ionization including analyte ion generation.

A quantitative model of ionization in ultraviolet matrix-assisted laser desorption/ionization (Knochenmuss, R. J. Mass Spectrom. 2002, 37, 867) is extended to include secondary ion-molecule reactions. Matrix-to-analyte charge-transfer reaction kinetics are described by a hard-sphere Arrhenius expression. The activation energy is derived from the reaction exoergicity using a nonlinear free energy relationship. The approach is applied to the specific case of proton-transfer reactions. With no adjustable parameters, the model correctly predicts the existence and characteristics of the matrix and analyte suppression effects, the shapes of the two-pulse time-delayed yield curves, and the dependence of analyte yields on laser fluence, molecular weight, relative concentrations, and reaction exoergicity.

Gramicidin↗

Reduction of Cu(II) in matrix-assisted laser desorption/ionization mass spectrometry.

The mechanisms of the reduction of Cu(II) in matrix-assisted laser desorption/ionization mass spectrometry (MALDI) are studied. In MALDI mass spectra, ions cationized by copper mostly contain Cu(I) even if Cu(II) salts are added to the sample. It was found that Cu(II) was reduced to Cu(I) by gas-phase charge exchange with matrix molecules, which is a thermodynamically favorable process. Under some conditions, large amounts of free electrons are present in the plume. Cu(II) can be even more efficiently reduced to Cu(I) by free electron capture in the gas phase. The matrices studied in this work are nicotinic acid, dithranol, and 2,5-dihydroxybenzoic acid.

Journal Article↗

Ionization energy reductions in small 2,5-dihydroxybenzoic acid-proline clusters.

The photoionization of (pro)(n)DHB (pro = proline, DHB = 2,5-dihydroxybenzoic acid, n = 0, 1, 2 or 4) clusters was studied both experimentally and computationally. Experimentally the (pro)(n)DHB clusters are generated in the gas phase by laser desorption and supersonic jet entrainment. The photoionization thresholds are then determined by the mass-selective measurement of both one- and two-color photoionization efficiency curves. These experiments demonstrate that the ionization energies (IEs) of the (pro)(n)DHB clusters are substantially reduced in comparison with the IE of free DHB. Computational studies of the (pro)(n)DHB clusters provide insights into the mechanism of IE reduction. For the (pro)DHB system the IE reduction results from spin delocalization in the ion state of the cluster. In contrast, for the (pro)(2)DHB and (pro)(4)DHB clusters the IE reduction results from an inductive delocalization of electron density from pro to DHB in the ground state of the cluster. This latter effect, which is a result of the specific hydrogen-bonding interactions occurring in the mixed clusters, leads to IE reductions of >1 eV. Finally, determination of the energetics of the (pro)(2)DHB radical cation demonstrate that the DHB-to-proline proton transfer reaction is a barrierless, exoergic process in the ion state and that energetic demands for cluster dissociation to protonated (pro)(2) plus a deprotonated DHB radical are substantially lower than those for cluster dissociation to (pro)(2) plus DHB(+*). Cumulatively, these studies provide new energetic and mechanistic insights into both primary and secondary MALDI ionization processes.

Journal Article↗