Robert J Eckersley

Publications and source records attributed to Robert J Eckersley.

13 recordsLinked to original sources

Frequency and pressure dependent attenuation and scattering by microbubbles.

The aim of this study was to evaluate experimentally the degree of pressure dependence of attenuation and scattering by microbubbles at low acoustic pressures with an empirical nonlinear model. In addition, the pressure dependency over a range of frequencies (1 to 5 MHz) has been studied. A series of transmission and scattering measurements were made with the microbubble SonoVue, using an automated system. Results show that, within the pressure range studied, attenuation as a result of the microbubble is pressure-dependent, whereas no such dependence of scattering was detectable. The pressure dependence of attenuation for SonoVue was found to be most significant at 1.5 MHz. The scattering is shown to be the highest at the lowest insonation frequency, around 1 approximately 1.25 MHz, and then decreases with frequency.

Humans↗

Hepatic vein transit time of SonoVue: a comparative study with Levovist.

PURPOSE: To prospectively compare transit times of Levovist and SonoVue in healthy volunteers and patients with biopsy-proved hepatitis C-related liver disease. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Forty patients and 25 healthy volunteers were examined. Subjects fasted, a bolus of SonoVue (0.6 mL) was injected into a cubital fossa vein, and hepatic venous time-intensity profiles were measured with spectral Doppler tracing. This was repeated with two injections of Levovist (2 g) and another injection of SonoVue. Time-intensity curves of spectral Doppler signals of right and middle hepatic veins were analyzed. A sustained signal intensity increase of 10% above baseline levels indicated hepatic vein transit time (HVTT). Carotid artery audio intensity was measured in volunteers. Analysis of variance and t tests were used for statistical analysis. RESULTS: Twelve patients had mild hepatitis; 18, moderate or severe hepatitis; and 10, cirrhosis. Mean HVTTs in control, mild hepatitis, moderate or severe hepatitis, and cirrhosis groups were 38.3 seconds +/- 2.4 (standard error), 47.5 seconds +/- 6.5, 29.5 seconds +/- 10.8, and 17.6 seconds +/- 5.0, respectively, with Levovist (P < .001) and 29.4 seconds +/- 6.9, 27.4 seconds +/- 9.3, 22.9 seconds +/- 4.7, and 16.4 seconds +/- 4.9, respectively, with SonoVue (P < .001). HVTT decreased as severity increased at imaging with both contrast agents. There was no significant difference in HVTT between mild and moderate hepatitis groups with SonoVue; however, there were significant differences in HVTT between all patient groups with Levovist. HVTT of SonoVue was shorter than that of Levovist in all groups (P < .001) except the cirrhosis group; in this group, HVTT of the two contrast agents was similar (P = .05). No difference was observed in mean cardiopulmonary transit time for SonoVue or Levovist (9.1 seconds +/- 2.4 [standard error] and 8.4 seconds +/- 2.5, respectively, P = .18). CONCLUSION: HVTT was significantly shorter with SonoVue than with Levovist; there was no significant difference in cardiopulmonary transit time.

Contrast Media↗

Investigating the nonlinear microbubble response to chirp encoded, multipulse sequences.

A modified Rayleigh-Plesset model was used to investigate the nonlinear acoustic response of ultrasound contrast microbubbles to multipulse phase and amplitude modulated, chirp encoded sequences. Trade-offs between the signal-to-noise ratio (SNR) and axial resolution were quantified for differing chirp time-bandwidth products and methods for minimising the artifacts formed in the postprocessing stages were developed. It was found that the chirp length can be increased and bandwidth reduced to improve SNR, though resolution is sacrificed. Results from the simulated chirp, pulse inverted, amplitude modulated (chirp PIAM) sequences were also compared with equivalent short pulse PIAM sequences and it was found that the chirp sequences preserve their extra energy after scattering, which translates to an improved SNR after processing. Compression artifacts were reduced by using chirps with a centre frequency and bandwidth tuned to the frequency response of the microbubble and reversing the frequency sweep of one chirp in the sequence.

Artifacts↗

Nonlinear propagation of ultrasound through microbubble contrast agents and implications for imaging.

Microbubble contrast agents produce nonlinear echoes under ultrasound insonation, and current imaging techniques detect these nonlinear echoes to generate contrast agent images accordingly. For these techniques, there is a potential problem in that bubbles along the ultrasound transmission path between transducer and target can alter the ultrasound transmission nonlinearly and contribute to the nonlinear echoes. This can lead to imaging artefacts, especially in regions at depth. In this paper we provide insight, through both simulation and experimental measurement, into the nonlinear propagation caused by microbubbles and the implications for current imaging techniques. A series of investigations at frequencies below, at, and above the resonance frequency of microbubbles were performed. Three specific effects on the pulse propagation (i.e., amplitude attenuation, phase changes, and harmonic generation) were studied. It was found that all these effects are dependent on the initial pulse amplitude, and their dependence on the initial phase of the pulse is shown to be insignificant. Two types of imaging errors are shown to result from this nonlinear propagation: first, that tissue can be misclassified as microbubbles; second, the concentration of microbubbles in the image can be misrepresented. It is found that these imaging errors are significant for all three pulse frequencies when the pulses transmit through a microbubble suspension of 6 cm in path length. It also is found that the first type of error is larger at the bubble resonance frequency.

Computer Simulation↗

Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power.

A series of in vitro experiments were performed to determine the efficacy of generalised phase- and amplitude-modulated sequences for low-power nonlinear microbubble contrast imaging. The microbubble agent Definity (Dupont, Boston, MA) was exposed to sequences in which the phase and amplitude were changed from one pulse to the next. Echoes from these pulses were combined to suppress or enhance particular linear or nonlinear components. The results show that established two-pulse pulse-inversion and amplitude-modulation approaches perform similarly, providing 14 +/- 1 dB of enhancement, compared with the echoes from the linear scatterer. A two-pulse combined phase and amplitude sequence achieved an additional 4 +/- 1 dB of enhancement. This improvement is due to improved preservation of second and third order harmonic signals, while maintaining the suppression of the linear signals. These results were obtained at low power, below the threshold of microbubble destruction, and are applicable to real-time perfusion imaging.

Contrast Media↗

Pressure-dependent attenuation with microbubbles at low mechanical index.

It has previously been shown that the attenuation of ultrasound (US) by microbubble contrast agents is dependent on acoustic pressure (Chen et al. 2002). Although previous studies have modelled the pressure-dependence of attenuation in single bubbles, this paper investigates this subject by considering a bulk volume of bubbles together with other linear attenuators. Specifically, a new pressure-dependent attenuation model for an inhomogeneous volume of attenuators is proposed. In this model, the effect of the attenuation on US propagation is considered. The model was validated using experimental measurements on the US contrast agent Sonovue. The results indicate, at low acoustic pressures, a linear relationship between the attenuation of Sonovue, measured in dB, and the insonating acoustic pressure.

Humans↗

A novel technique to measure splanchnic transit time using microbubble ultrasound.

OBJECTIVE: The objective of this study was to measure splanchnic transit time by intravenous injection of a microbubble. MATERIALS AND METHODS: Ten volunteers were examined before and after eating. After Doppler indices of splanchnic circulation were obtained, the superior mesenteric artery (SMA) and vein (SMV) were simultaneously interrogated using power Doppler ultrasound after intravenous injection of a microbubble. Contrast arrival in the SMA and subsequently the SMV was recorded and splanchnic transit time calculated from differences in the time-intensity curves. RESULTS: Splanchnic transit time decreased significantly after eating (mean 11 vs. 6.9 seconds; P = 0.007), reflecting splanchnic hemodynamics. Between-subject variability attributable to repeated measurements was least for the SMA resistive index (17%) but 56% for the new index, suggesting poor reproducibility. CONCLUSION: Splanchnic transit time may be measured by microbubble injection but is subject to considerable measurement error. Newer microbubbles and imaging methods may allow more reproducible measurements.

Adult↗

Can Doppler sonography grade the severity of hepatitis C-related liver disease?

OBJECTIVE: Many authors have claimed that Doppler sonography indexes are of value in grading and assessing diffuse liver disease. However, there is much controversy regarding the reliability and reproducibility of these techniques. We performed a prospective study to evaluate whether these methods can grade disease in a well-stratified cohort of patients with hepatitis C virus (HCV)-related liver disease. SUBJECTS AND METHODS: Sixty-five patients with biopsy-proven HCV-related liver disease were recruited, and Doppler sonography was performed by one operator. The patients were classified into one of the following three groups on the basis of the Ishak-modified histologic activity index (HAI) fibrosis (F) and necroinflammatory (NI) scores: mild hepatitis (F < or = 2 and NI < or = 3), moderate or severe hepatitis (3 < or = F < 6 or NI > or = 4), or cirrhosis (F = 6/6). We measured the following Doppler indexes: main hepatic artery peak velocity (Vmax) and resistive index, main portal vein peak velocity (Vmax), and maximal portal vein diameter and circumference that allowed calculation of the portal vein congestive index (portal vein area and portal vein velocity). The ratio of the hepatic artery velocity (Vmax) to the portal vein velocity (Vmax) was also calculated, and the phasicity (triphasic, biphasic, or monophasic) of the hepatic veins of each patient was recorded. We also measured the maximal spleen length longitudinally. RESULTS: A total of 65 patients with liver disease (mild hepatitis, n = 20; moderate or severe hepatitis, n = 25; cirrhosis, n = 20) with biopsy-proven HCV-related liver disease were studied. Optimal hepatic arterial traces were obtained in only 30 patients and portal vein circumference in 18 patients. No significant differences were observed in the Doppler indexes with increasing severity of liver disease. Five (29%) of 17 patients with mild hepatitis had an abnormal hepatic vein trace (i.e., biphasic or monophasic) compared with 11 (55%) of 20 patients with moderate or severe hepatitis and 12 (60%) of 20 patients with cirrhosis. The only index to show a significant intergroup difference was splenic length (analysis of variance, p < 0.001), but there was still overlap between the groups. CONCLUSION: Doppler-derived indexes, which have previously been recommended for the assessment of severity in chronic liver disease, are difficult to reproduce reliably and therefore have a limited clinical role in the noninvasive assessment of hepatic fibrosis or inflammation.

Cohort Studies↗

Evidence for spleen-specific uptake of a microbubble contrast agent: a quantitative study in healthy volunteers.

PURPOSE: To evaluate the pharmacokinetics of the microbubble contrast agent BR1. MATERIALS AND METHODS: Twenty healthy volunteers were injected via arm vein with a 1.2-mL bolus of BR1. Ultrasonographic images of liver and right kidney and of spleen and left kidney were obtained intermittently for 5 minutes with low-mechanical-index software (to minimize microbubble destruction) that shows stationary microbubbles in green. Percentage total uptake was calculated as the number of green pixels in the region of interest for each organ over time, divided by the total pixels. Relative uptake, the ratio of total uptake in liver to that in right kidney and of total uptake in spleen to that in left kidney, and differential uptake, the difference in total uptake between liver and right kidney and between spleen and left kidney, were calculated. Total uptake for each organ was plotted against time, and the gradient of a best-fit straight line was calculated. Wilcoxon signed rank test was used to compare mean uptake values in each subject. Mann-Whitney U test was used for comparisons in sex and age. RESULTS: Total uptake declined over 5 minutes in left and right kidney and in liver (from 88% +/- 10% [1 minute] to 67% +/- 14% [5 minutes]), but not in spleen (range, 90%-99%). Mean relative uptake +/- 1 SD for spleen increased from 2.3 +/- 0.7 (1 minute) to 3.7 +/- 2.3 (5 minutes) (P =.005) but for liver was constant: 2.1 +/- 0.9 (1 minute) and 2.3 +/- 0.4 (5 minutes) (P =.06). Mean differential uptake +/- 1 SD for spleen increased from 51.3% +/- 14.9% (1 minute) to 65.0% +/- 9.1% (5 minutes) (P =.002). Significant difference was seen over time in total uptake gradients between spleen and left kidney (P =.014) but not between liver and right kidney or right and left kidney. No difference was seen between men and women or with age. CONCLUSION: BR1 produces spleen-specific enhancement that is longer (5 minutes) than the blood pool phase.

Adult↗

Quantitative microbubble enhanced transrectal ultrasound as a tool for monitoring hormonal treatment of prostate carcinoma.

BACKGROUND: We quantified changes in prostate carcinoma vascularity treated with anti-androgens using color Doppler and power transrectal ultrasound in combination with microbubble contrast agent Levovist. METHODS: Thirty-six men with prostate carcinoma were studied at baseline and at intervals during treatment. At each attendance, Levovist((R)) (10 ml, 300 mg/ml) was given as an iv bolus. Using quantitative analysis, we calculated the pre-enhancement scores, arrival time, time to peak, peak value, and area under the time-enhancement curve (AUC). These were compared to pre-treatment values and serial PSA measurements. RESULTS: The pre-enhancement, peak value, and AUC each showed a marked response with reductions within one week. The average AUC declined to 68% +/- 9% (mean +/- standard error) by week 1, 56% +/- 9% by week 3, and 20% +/- 4% by week 6. A strong correlation with changes in the mean PSA (r = 0.95, P < 0.001) was also measured. In four patients, Doppler indices did not fall with PSA: two patients with the most marked discrepancy relapsed at 6 months. CONCLUSION: The vascular enhancement declined with therapy, similar to PSA. Microbubble enhanced ultrasound can show early response to treatment.

Androgen Antagonists↗

Which continuous US scanning mode is optimal for the detection of vascularity in liver lesions when enhanced with a second generation contrast agent?

OBJECTIVES: Microbubble echo-enhancers help in the assessment of focal liver masses by enhancing the signal from blood vessels. A variety of linear and nonlinear scanning modes are now available, but it is unclear which is optimal. A controlled comparison was performed during the infusion of such an agent (SonoVue: Bracco, Milan, Italy). METHODS AND MATERIALS: Ten patients with known focal liver lesions were studied. The diagnoses, confirmed on dual phase helical computed tomography (CT) at the same attendance were metastasis (n = 7), haemangioma (n = 2) and focal nodular hyperplasia FNH (n = 1). A dose of 12 ml SonoVue concentrated at 5 mg/ml was infused intravenously at a rate of 1 ml/min. The enhancement level was monitored with a continuous wave (CW) Doppler probe over the right radial artery and the intensity of the signal was registered at 1 s intervals. When a plateau of enhancement was reached, a single lesion in each patient was imaged using five different continuous scanning modes, fundamental grey scale (FGS); fundamental colour Doppler (FCD); fundamental power Doppler (FPD); second harmonic grey scale (HGS); and pulse inversion mode (Pim) using an HDI5000 scanner and C5-2 probe (ATL, Bothell, WA). The order of scanning modes was varied between patients using a predefined randomisation protocol. The videos (super video home system (SVHS)) were analysed offsite by two blinded readers, both experienced in contrast ultrasound of the liver. The readers were asked to score each mode in terms of its ability to detect vessels within/around the lesion at optimal enhancement. This was done using a ranking system (1, worst; 5, best) for each patient. RESULTS: Both observers scored FPD as the optimal imaging method, followed by Pim. (Scores summed across all patients, observer 1: FPD 48, Pim 42, FCD 37, HGS 21, FGS 10; observer 2: FPD 49, Pim 40, FCD 38, HGS 21, FGS 10). The differences from FPD were significant for FCD, HGS and FGS using a unpaired analysis of variance (ANOVA) comparison, with Bonferroni multiple corrections, (P<0.01, both observers). The differences between FPD and Pim were also significant both for observer 2 and for both observers combined (P<0.01), but did not reach significance for observer 1 (P = 0.19). CONCLUSIONS: In this study, FPD performed best, and the non-linear modes, performed continuously (pulse inversion and second HGS), showed no clear advantage.

Adult↗

Enhancement characteristics of the microbubble agent Levovist: reproducibility and interaction with aspirin.

We investigated the reproducibility of Doppler enhancement indices following intravenous bolus injections of Levovist (Schering AG, Berlin) microbubbles. We also aimed to determine whether observations from animal studies suggesting that aspirin potentiates microbubble enhancement were reproducible in humans. In five healthy volunteers, time enhancement profiles of Doppler intensity following repeated bolus injections of Levovist were acquired from the common carotid artery, hepatic vein and kidney using spectral and power Doppler before and after oral aspirin (600 mg). Peak enhancement (PE), area under the curve (AUC) and decay slopes (lambda) were calculated. Hepatic vein contrast arrival time (AT) was determined subjectively. Well-defined carotid enhancement was seen in 19/20 injections. Reproducibility was high (r > 0.8). PE and AUG were unaffected by aspirin, but lambda was slightly reduced (P = 0.02). Renal power Doppler profiles were well defined (10/10) with no significant changes of AUC, PE or lambda after aspirin. Our study demonstrates good reproducibility of carotid spectral Doppler time intensitometry with Levovist in man. Aspirin does not have a significant effect on enhancement indices except carotid spectral Doppler decay. We conclude that aspirin is unlikely to potentiate microbubble enhancement, as seen in animal studies.

Adult↗

Advances in ultrasound.

Ultrasound (US) has undergone dramatic changes since its inception three decades ago; the original cumbersome B-mode gantry system has evolved into a high resolution real-time imaging system. This review describes both recent advances in ultrasound and contrast media and likely future developments. Technological advances in electronics and computing have revolutionized ultrasound practice with ever expanding applications. Developments in transducer materials and array designs have resulted in greater bandwidths with improvements in spatial and contrast resolution. Developments in digital signal processing have produced innovations in beam forming, image display and archiving. Technological advances have resulted in novel imaging modes which exploit the non-linear behaviour of tissue and microbubble contrast agents. Microbubble contrast agents have dramatically extended the clinical and research applications of ultrasound. Not only can Doppler studies be enhanced but also novel non-linear modes allow vessels down to the level of the microcirculation to be imaged. Functional and quantitative studies allow interrogation of a wide spectrum of tissue beds. The advent of tissue-specific agents promises to improve the sensitivity and specificity of ultrasound in the detection and characterization of focal liver lesions to rival that of computed tomography (CT) and magnetic resonance imaging (MRI). Ultrasound has recently moved into therapeutic applications with high intensity focused ultrasound (HIFU) and microbubble assisted delivery of drugs and genes showing great promise.

Humans↗