PubMed Health⌕ Search

PubMed · 17169700

Investigating the nonlinear microbubble response to chirp encoded, multipulse sequences.

Abstract

A modified Rayleigh-Plesset model was used to investigate the nonlinear acoustic response of ultrasound contrast microbubbles to multipulse phase and amplitude modulated, chirp encoded sequences. Trade-offs between the signal-to-noise ratio (SNR) and axial resolution were quantified for differing chirp time-bandwidth products and methods for minimising the artifacts formed in the postprocessing stages were developed. It was found that the chirp length can be increased and bandwidth reduced to improve SNR, though resolution is sacrificed. Results from the simulated chirp, pulse inverted, amplitude modulated (chirp PIAM) sequences were also compared with equivalent short pulse PIAM sequences and it was found that the chirp sequences preserve their extra energy after scattering, which translates to an improved SNR after processing. Compression artifacts were reduced by using chirps with a centre frequency and bandwidth tuned to the frequency response of the microbubble and reversing the frequency sweep of one chirp in the sequence.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kevin Chetty, Joseph V Hajnal, Robert J Eckersley. 2006. Investigating the nonlinear microbubble response to chirp encoded, multipulse sequences.. https://doi.org/10.1016/j.ultrasmedbio.2006.06.022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗