Advantages of parallel imaging in conjunction with hyperpolarized helium--a new approach to MRI of the lung.

Hyperpolarized helium (3He) gas MRI has the potential to assess pulmonary function. The non-equilibrium state of hyperpolarized 3He results in the continual depletion of the signal level over the course of excitations. Under non-equilibrium conditions the relationship between the signal-to-noise ratio (SNR) and the number of excitations significantly deviates from that established in the equilibrium state. In many circumstances the SNR increases or remains the same when the number of data acquisitions decreases. This provides a unique opportunity for performing parallel MRI in such a way that both the temporal and spatial resolution will increase without the conventional decrease in the SNR. In this study an analytical relationship between the SNR and the number of excitations for any flip angle was developed. Second, the point-spread function (PSF) was utilized to quantitatively demonstrate the unconventional SNR behavior for parallel imaging in hyperpolarized gas MRI. Third, a 24-channel (24ch) receive and two-channel (2ch) transmit phased-array system was developed to experimentally prove the theoretical predictions with 3He MRI. The in vivo experimental results prove that significant temporal resolution can be gained without the usual SNR loss in an equilibrium system, and that the entire lung can be scanned within one breath-hold (approximately 13 s) by applying parallel imaging to 3D data acquisition.

Administration, Inhalation↗

Diffusional kurtosis imaging in the lung using hyperpolarized 3He.

Diseases of the small airspaces represent an increasingly important health problem. Asthma is primarily a disease of airway dysfunction, while chronic obstructive pulmonary disease (COPD) is associated with abnormalities in both the small airways and the alveoli. Conventional diffusion magnetic resonance imaging (MRI) of hyperpolarized noble gases, because of the short T(2)* of the gas, is only capable of monitoring diffusion over short times and hence only short distances. Diffusion imaging is therefore only sensitive to changes in small structures of the lung (primarily the alveoli), and will not adequately interrogate diffusion along the longitudinal axes of bronchi and bronchioles. In this communication we present a new method, termed diffusional kurtosis imaging (DKI), that is particularly sensitive to diffusion over longer distances. DKI may therefore be more sensitive to abnormalities in the bronchioles and bronchi than conventional diffusion imaging. Preliminary DKI measurements on healthy human subjects and one patient with symptoms suggestive of small airway disease are presented. Although the apparent diffusion coefficient (ADC) in the patient was similar to that in the normal controls, diffusional kurtosis was markedly reduced. This suggests that DKI measurements may be useful for assessing diseases of the small airways.

Artifacts↗

Towards quantification of blood-flow changes during cognitive task activation using perfusion-based fMRI.

Multi-slice perfusion-based functional magnetic resonance imaging (p-fMRI) is demonstrated with a color-word Stroop task as an established cognitive paradigm. Continuous arterial spin labeling (CASL) of the blood in the left common carotid artery was applied for all repetitions of the functional run in a quasi-continuous fashion, i.e., it was interrupted only during image acquisition. For comparison, blood oxygen level dependent (BOLD) contrast was detected using conventional gradient-recalled echo (GE) echo planar imaging (EPI). Positive activations in BOLD imaging appeared in p-fMRI as negative signal changes corresponding to an enhanced transport of inverted water spins into the region of interest, i.e., increased cerebral blood flow (CBF). Regional differences between the localization of activations and the sensitivity of p-fMRI and BOLD-fMRI were observed as, for example, in the inferior frontal sulcus and in the intraparietal sulcus. Quantification of CBF changes during cognitive task activation was performed on a multi-subject basis and yielded CBF increases of the order of 20-30%.

Adult↗

Continuous arterial spin labeling at the human common carotid artery: the influence of transit times.

In evaluating the sensitivity of arterial spin labeling (CASL) and for quantification of perfusion, knowledge of the transit time from the labeling plane to the imaging slice is crucial. The purpose of the current study was to obtain estimates of transit times relevant under the specific experimental conditions of CASL in human subjects using a separate local labeling coil at the neck. Specifically, the post-label delay (PLD), i.e. the time between the end of the labeling period and the image acquisition, was varied either with or without additional application of crusher gradients to suppress intravascular signal contributions. The overall sensitivity change for varying the PLD between 1000 and 1700 ms was low. A tissue transit time from the neck to an axial supraventricular section through Broca's knee was obtained by fitting the PLD dependence to a two-compartment model. Averaging over subjects yielded 1930 +/- 110 ms for the tissue transit time, and 73 +/- 5 ml min(-1) 100 g(-1) for the cerebral blood flow. Small areas that exhibited a very high signal change upon labeling were indicative of regional variation in cerebral blood flow related to vascular anatomy.

Adult↗

Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: a computer simulation.

Continuous arterial spin labeling (CASL) using adiabatic inversion is a widely used approach for perfusion imaging. For the quantification of perfusion, a reliable determination of the labeling efficiency is required. A numerical method for predicting the labeling efficiency in CASL experiments under various experimental conditions, including spin relaxation, is demonstrated. The approach is especially useful in the case of labeling at the carotid artery with a surface coil, as consideration of the experimental or theoretical profile of the B(1) field is straightforward. Other effects that are also accounted for include deviations from a constant labeling gradient, and variations in the blood flow velocity due to the cardiac cycle. Assuming relevant experimental and physiological conditions, maximum inversion efficiencies of about 85% can be obtained.

Blood Flow Velocity↗

Pulsed-field gradient-nuclear magnetic resonance (PFG NMR) to measure the diffusion of ions and polymers in cartilage: applications in joint diseases.

Since cartilage contains neither blood nor lymph vessels, diffusion is the most important transport process for the supply of cartilage with nutrients and for the removal of metabolic waste products. Therefore, diffusion measurements are of high interest in cartilage research. Different techniques of diffusion measurements exist. Here we describe methods based on pulsed-field gradient nuclear magnetic resonance (PFG NMR). This technique offers the considerable advantage that neither concentration gradients nor labeling of the diffusing species are required. In addition to the description of the fundamentals and the applicability of PFG NMR studies in cartilage research, emphasis is on the influence of the observation time, Delta, on the diffusion coefficient, D: at short times, diffusion is primarily determined by the water content of the sample, and great care is needed to keep this parameter constant. However, by varying the diffusion time, data on the internal structure of cartilage, e.g., the distance of the collagen fibrils, can also be obtained. In addition to classical water diffusion, the diffusion behavior of selected ions and polymers in cartilage is described. The capabilities, the limitations, and the clinical relevance of diffusion measurements for the assessment of joint diseases are discussed.

Animals↗

Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 T.

Functional perfusion imaging with a separate labeling coil located above the common carotid artery was demonstrated in human volunteers at 3 T. A helmet resonator and a spin-echo echo-planar imaging (EPI) sequence were used for imaging, and a circular surface coil of 6 cm i.d. was employed for labeling. The subjects performed a finger-tapping task. Signal differences between the condition of finger tapping and the resting state were between -0.5% and -1.1 % among the subjects. The imaging protocol included a long post-label delay (PLD) to reduce transit time effects. Labeling was applied for all repetitions of the functional run to reduce the sampling interval.

Adult↗

Self-diffusion of polymers in cartilage as studied by pulsed field gradient NMR.

Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) was used to investigate the self-diffusion behaviour of polymers in cartilage. Polyethylene glycol and dextran with different molecular weights and in different concentrations were used as model compounds to mimic the diffusion behaviour of metabolites of cartilage. The polymer self-diffusion depends extremely on the observation time: The short-time self-diffusion coefficients (diffusion time Delta approximately 15 ms) are subjected to a rather non-specific obstruction effect that depends mainly on the molecular weights of the applied polymers as well as on the water content of the cartilage. The observed self-diffusion coefficients decrease with increasing molecular weights of the polymers and with a decreasing water content of the cartilage. In contrast, the long-time self-diffusion coefficients of the polymers in cartilage (diffusion time Delta approximately 600 ms) reflect the structural properties of the tissue. Measurements at different water contents, different molecular weights of the polymers and varying observation times suggest that primarily the collagenous network of cartilage but also the entanglements of the polymer chains themselves are responsible for the observed restricted diffusion. Additionally, anomalous restricted diffusion was shown to occur already in concentrated polymer solutions.

Animals↗

Continuous arterial spin labeling using a local magnetic field gradient coil.

Continuous arterial spin labeling (ASL) using a locally induced magnetic field gradient for adiabatic inversion of spins in the common carotid artery of human volunteers is demonstrated. The experimental setup consisted of a helmet resonator for imaging, a circular RF surface coil for labeling, and gradient loops to produce a magnetic field gradient. A spin-echo (SE) echo-planar imaging (EPI) sequence was used for imaging. The approach is independent of the gradients of the MR scanner. This technology may be used if the imaging gradient system does not produce an appropriate magnetic field gradient at the location of the carotid artery-for example, in a head-only scanner-and is a prerequisite for the development of a system that allows continuous labeling during the imaging experiment.