PubMed Health⌕ Search

PubMed · 16958076

Diffusional kurtosis imaging in the lung using hyperpolarized 3He.

Abstract

Diseases of the small airspaces represent an increasingly important health problem. Asthma is primarily a disease of airway dysfunction, while chronic obstructive pulmonary disease (COPD) is associated with abnormalities in both the small airways and the alveoli. Conventional diffusion magnetic resonance imaging (MRI) of hyperpolarized noble gases, because of the short T(2)* of the gas, is only capable of monitoring diffusion over short times and hence only short distances. Diffusion imaging is therefore only sensitive to changes in small structures of the lung (primarily the alveoli), and will not adequately interrogate diffusion along the longitudinal axes of bronchi and bronchioles. In this communication we present a new method, termed diffusional kurtosis imaging (DKI), that is particularly sensitive to diffusion over longer distances. DKI may therefore be more sensitive to abnormalities in the bronchioles and bronchi than conventional diffusion imaging. Preliminary DKI measurements on healthy human subjects and one patient with symptoms suggestive of small airway disease are presented. Although the apparent diffusion coefficient (ADC) in the patient was similar to that in the normal controls, diffusional kurtosis was markedly reduced. This suggests that DKI measurements may be useful for assessing diseases of the small airways.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert Trampel, Jens H Jensen, Ray F Lee, Igor Kamenetskiy, Georgeann McGuinness, Glyn Johnson. 2006. Diffusional kurtosis imaging in the lung using hyperpolarized 3He.. https://doi.org/10.1002/mrm.21045

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗