PubMed Health⌕ Search

Biomedical subjects

Roger S Anderson

Publications and source records attributed to Roger S Anderson.

12 recordsLinked to original sources

The effect of simulated lens yellowing and opacification on blue-on-yellow acuity and contrast sensitivity.

Short-wavelength-sensitive (SWS) resolution acuity has been reported to be limited by the density of the responding ganglion cells for people without appreciable age-related lenticular change. This study measured the robustness of SWS-cone acuity and contrast sensitivity (CS) to simulated lens yellowing and opacification. Resolution acuity at 8 deg eccentricity proved robust to significant amounts of yellowing and remained lower than detection acuity, indicating that the resolution continued to be limited by ganglion cell density. Both the detection and resolution CS functions were affected by simulated lens yellowing, except for resolution close to the CS cut-off. For simulated opacification, only dense opacity significantly affected performance. SWS resolution acuity and CS close to the resolution limit are resistant to moderate simulated age-related lens changes and continue to be mediated by the density of the responding ganglion cells, indicating important clinical potential to measure SWS neural losses of vision in older subjects.

Adult↗

Severity staging by early features of age-related maculopathy exhibits weak relationships with functional deficits on SWS grating acuity.

PURPOSE: To examine the relationship between short-wavelength-sensitive (SWS) resolution acuity and epidemiologically defined stages of early age-related maculopathy (ARM). METHODS: Subjects consisted of 88 adults aged 51 to 87 years. Psychophysical testing was undertaken in only one eye of each subject (the study eye). All study eyes had a LogMAR acuity of 0.30 (20/40 Snellen) or better. SWS and achromatic grating resolution acuity were measured at 6 degrees eccentricity from the fovea. Stereoscopic color fundus photographs centered on the macula were taken on both eyes of each subject and were graded using the Wisconsin Age-Related Maculopathy Grading System (WARMGS). After grading, features of ARM were combined to assign a severity stage from 0 to 5 using the methods described by the Rotterdam Eye Study. Relationships between visual function, study eye ARM stage, and fellow eye status were examined with the use of standard statistical analysis. RESULTS: Although SWS resolution acuity was significantly reduced in eyes classified as having any ARM compared with eyes classified as having no ARM (P = 0.002), there was no relationship between the severity of functional deficits and the morphologic severity from stage 1 to stage 4. On reassigning subject eyes to a revised severity staging (stage 0, stages 1 to 4 combined, and stage 5), SWS acuity was significantly different among these three groups (P < 0.001). No significant relationship was found between achromatic resolution acuity and ARM staging. The status of the fellow eye (advanced macular degeneration present or absent) was not significantly related to visual function in the study eye. CONCLUSIONS: Significant functional deficits in SWS resolution acuity were found in eyes with ARM features, but the severity of functional loss did not correlate well with the currently accepted method of assigning a morphologic severity stage. Longitudinal studies may reveal further information on the relationships between functional deficits, ARM status, disease progression, and outcome.

Aged↗

Human S-cone vision: relationship between perceptive field and ganglion cell dendritic field.

We measured the S-cone contrast threshold for stimuli of different size modulated along the white -90 deg direction in the isoluminant plane of DKL color space. The stimuli were presented at eccentricities of 5-30 deg in the horizontal temporal retinal meridian. Ricco's area of complete spatial summation was estimated using a bilinear fit of the log threshold/log area function. Ricco's area increased towards the retinal periphery to include an increasing number of S-cones while remaining 1.6-1.8 times larger than the dendritic field area of the small bistratified and parasol retinal ganglion cells. Assuming constant coverage factor by the dendritic field, Ricco's area incorporated a constant number (three to four) of small bistratified cells. It was also found that the threshold contrast for stimuli that matched Ricco's area was constant across the studied eccentricity range, similar to previous findings for achromatic vision. Our data support the point of view that this invariance is the result of a constant number of cells involved in stimulus detection.

Adult↗

The psychophysics of glaucoma: improving the structure/function relationship.

Perimetry of some kind remains an important tool in the detection, diagnosis and monitoring of glaucomatous damage to the visual pathway. However, recent studies have served to reinforce the suspicion that conventional perimetry does not possess the sensitivity to detect the earliest signs of functional loss resulting from glaucoma. The relationship between differential light threshold and ganglion cell loss is extremely weak and, in the early stages of glaucoma, non-existent. Alternative, more novel perimetric techniques seem to offer promise of better detectability for early loss by claiming to tap in to one or other of the separate parallel pathways of the visual system. While some of these tests show potential for better detection and monitoring of glaucoma, the reasons why this might be so are not always clearly formulated or represented. This leads to misunderstanding of what the test actually measures and of the glaucomatous disease process itself. This paper seeks to revisit and review the theory underlying psychophysical testing of visual function related to glaucoma and stresses the importance of developing tests that are based on a firm theoretical understanding of visual function and processing in order to both detect glaucoma at an earlier stage and better understand the mechanisms of loss from the disease process.

Glaucoma↗

Simulated impairment of contrast sensitivity: performance and gaze behavior during locomotion through a built environment.

PURPOSE: An experimental study investigated the effects of simulated impairment of contrast sensitivity (CS) on performance and eye gaze patterns during locomotion through a library. METHOD: Normally sighted participants with simulated CS impairment (diffusive blur) walked two routes, one entailing limited change in direction (simple) and the other entailing several changes in direction (complex), while eye movements relative to the scene were recorded. Performance variables included walking speed in completing the route, pauses during travel, and collisions with objects on the route. For eye movements, dwell time and saccades were determined for each of three object classes: (1) objects on the route below eye level; (2) objects on the route extending above eye level; and (3) elsewhere-objects not on the route. RESULTS: Walking speed was significantly affected by CS level and by route; pauses and collisions were rare. Dwell times and saccades suggested limited attention directed to low-level objects, except for CS impairment on the complex route. In the complex route, saccades and dwell times in the object class "elsewhere" were also reduced. CONCLUSIONS: The results for the simple route suggest ballistic strategies: the participant appraises the scene and follows a more or less predetermined path. For the complex route, CS impairment appears to adversely affect information processing and locomotion. The results have implications for the design of built environments, especially with regard to the safety of visually impaired occupants during emergency scenarios.

Adult↗

The filtered Fourier difference spectrum predicts psychophysical letter discrimination in the peripheral retina.

We wished to devise a measure of dissimilarity (D) which could predict psychophysical discrimination performance for Snellen letter pairs in peripheral vision. Threshold size for discriminating 33 pairs of Snellen letters was measured at 30 degrees eccentricity in the nasal retina for two subjects. D was computed for each pair by performing an overlap subtraction in the spatial domain, followed by a Fast Fourier Transform on this difference image, and dividing the total power in the resultant 'difference spectrum' by the sum of the powers of the individual letter spectra. A plot of D vs. psychophysical threshold letter size gave a mean correlation of R = -0.81. When D was calculated for letters that were low-pass filtered at different cut-off frequencies, the correlation with psychophysical performance was greatest when cut-off was between 1.25-1.9 cycles/letter (R = -0.85). Conversely, when the difference spectrum was high-pass filtered at different cut-off frequencies, the correlation decreased continuously as the cut-off increased. These results imply that the band of frequencies between zero and 1.25 cycles/letter are most important for letter discrimination in peripheral vision.

Discriminant Analysis↗

Spatial summation of S-cone ON and OFF signals: effects of retinal eccentricity.

We studied spatial summation for S-cone ON and OFF signals as a function of retinal eccentricity in human subjects. S-cone isolation was obtained by the two-colour threshold method of Stiles, modified by adding blue light to the yellow background. Test stimuli were blue light increments or decrements within a circular area of variable size. These were presented for 100 ms at 0 to 20 deg along the horizontal temporal retinal meridian. Ricco's area of complete spatial summation was measured from the threshold vs. area curves. This was nearly constant and approximately the same for both types of stimuli within the 0-5 deg range and increased beyond this range. The decremental area increased faster, suggesting that separate mechanisms, presumably ON and OFF, integrate S-cone increments and decrements. The results appear to provide new evidence for the existence of separate S-cone ON and OFF pathways. We compare the data with known morphology of primate retina and assume that, if S-cone decrements are detected via separate OFF cells, these should differ in density and dendritic field size from the S-cone ON cells, but only in the retinal periphery.

Adult↗

Short-wavelength acuity: optical factors affecting detection and resolution of blue-yellow sinusoidal gratings in foveal and peripheral vision.

Previous studies have indicated that peripheral achromatic grating resolution is limited by the sampling density of the neural array (sampling limited), and largely unaffected by large amounts of optical defocus and significant changes in luminance. Under certain conditions, peripheral short-wavelength sensitive (SWS) grating acuity is also sampling limited. We wished to determine how the sampling-limited nature of SWS-driven grating resolution was affected by changing optical defocus and stimulus luminance. Using SWS-cone isolation techniques, detection and resolution acuity were measured for sinusoidal gratings under varying levels of stimulus mean luminance and optical defocus in the fovea and at 20 degrees eccentricity. From 1.4 down to 0.3 cd/m(2) peripheral detection acuity was superior to resolution acuity, accompanied by observations of aliasing: there was little change in resolution performance throughout this range. For defocus up to 3-4 dioptres, peripheral detection acuity was superior to resolution but fell steadily: resolution performance remained flat throughout the same range. Unlike achromatic acuity, foveal resolution performance displayed some robustness to defocus but to a lesser degree than the periphery. Peripheral SWS-driven resolution remains sampling limited for large changes in stimulus luminance and optical defocus, and should thus be useful as a clinical test of SWS-driven ganglion cell density.

Color Perception↗

Short-wavelength acuity: blue-yellow and achromatic resolution loss with age.

Previous studies have indicated that peripheral resolution for achromatic gratings is sampling limited and directly related to the density of the underlying midget ganglion cell population. Previous studies by the authors have shown that peripheral resolution for blue-cone isolating gratings is also sampling limited, is robust to optical defocus and short-wavelength attenuation, and yields estimates of sampling density which correspond closely with the density of small bistratified ganglion cells. We measured peripheral resolution in a group of normal subjects ranging in age from 12 to 72 years, using both achromatic and blue-cone isolating gratings, to determine how performance (and hence ganglion cell density) changed with age for both systems. Resolution was higher for achromatic than blue-yellow gratings and performance was flat for both until the fifth decade. After this, performance declined for both at a rate of approximately 14%/decade with no significant difference between the two rates of decline. Individual measurements of lens density were not correlated with short-wavelength sensitive resolution performance in the older subjects, further indicating that the decline in resolution was not attributable to pre-retinal absorption.

Adolescent↗

Peripheral resolution for achromatic and SWS gratings in early to moderate glaucoma and the implications for selective ganglion cell density loss.

PURPOSE: To investigate whether there is significant selective reduction in short-wavelength-sensitive (SWS) ganglion cell density in early to moderate glaucoma. METHODS: Peripheral achromatic resolution acuity (an indirect measure of the underlying midget ganglion cell density) and peripheral chromatic resolution acuity under conditions of blue cone isolation (an indirect measure of the underlying small bistratified ganglion cell density) were measured at 13 degrees eccentricity in four oblique meridians in 15 eyes (mean age, 64.6 +/- 9.6 years) with early to moderate glaucoma. The results from the subjects with glaucoma were compared with those in a group of 17 age-matched normal eyes (mean age, 62.5 +/- 6.6 years). RESULTS: Mean achromatic resolution acuity across the four locations was significantly lower in the subjects with glaucoma than in the normal subjects (2.92 vs. 4.01 cyc/deg). Mean chromatic resolution acuity across the four locations was also significantly lower in the subjects with glaucoma than the normal subjects (0.78 vs. 0.99 cyc/deg). There was no selective loss of mean SWS acuity in the subjects with glaucoma. Individual location analysis revealed that the chromatic-achromatic resolution ratio was not significantly different in the subjects with glaucoma who had early glaucomatous damage when compared with the normal subjects. The chromatic-achromatic resolution ratio was lower than normal at certain locations in certain individuals with early glaucoma. CONCLUSIONS: The results indicate that there is no evidence of significant selective reduction in global SWS ganglion cell density in early to moderate glaucoma. However, there may be selective loss of SWS ganglion cell density at individual locations in individual eyes.

Aged↗

What limits detection and resolution of short-wavelength sinusoidal gratings across the retina?

Peripheral resolution acuity for achromatic gratings is known to be limited by the density of the underlying ganglion cell sampling array. After confirming isolation of the short-wavelength sensitive (SWS) system using chromatic adaptation methods, we wished to determine if resolution is limited by blue/yellow ganglion cell sampling (evidenced by a superiority of detection over resolution acuity and the perception of aliasing) and thus directly related to SWS-driven ganglion cell density. We measured detection and resolution acuity between 0 degrees and 35 degrees, using blue sinusoidal gratings superimposed on a yellow adapting background which ranged in intensity from 2.5 to 4.7logTrolands. At all locations, a break could be observed in the acuity vs. illumination curves followed by a plateau. Detection and resolution acuity were the same for low background intensities, but resolution acuity was lower than detection at higher intensities, accompanied by observations of chromatic aliasing. SWS resolution is sampling-limited across the retina and agrees well with predicted performance based on anatomical estimates of small bistratified ganglion cell density.

Adolescent↗

Changes in human short-wavelength-sensitive and achromatic resolution acuity with retinal eccentricity and meridian.

Psychophysical measurements using achromatic grating resolution acuity in peripheral vision show a prominent retinal asymmetry in acuity which is consistent with predicted values based on available estimates of midget ganglion cell density. Recent studies have shown that peripheral grating resolution acuity values for short-wavelength-sensitive (SWS) isolating gratings in normal observers are closely related to predicted values based on the underlying small bistratified ganglion cell density. By measuring SWS resolution acuity at different locations across the visual field, we wished to see if any significant acuity asymmetry exists for the short-wavelength system. In addition to this, we wanted to compare SWS and achromatic resolution acuity at different retinal locations of equal eccentricity. SWS and achromatic grating resolution acuity was measured in two observers at a number of different retinal meridians of 10- and 25-deg eccentricity from the fovea, and out to 35-deg eccentricity along the horizontal meridian. Achromatic resolution acuity was higher than SWS resolution acuity at all locations. At 10-deg eccentricity there was slight radial asymmetry in SWS and achromatic acuity, both displaying highest acuity along the horizontal meridian. At 25-deg eccentricity, SWS and achromatic acuity showed significant asymmetry with acuity being higher in the nasal retina compared to the temporal retina and with higher acuity in the superior retina compared to the inferior retina. At 35-deg eccentricity, the acuity asymmetry along the horizontal meridian was maintained with acuity for both significantly higher in the nasal retina. The SWS acuity changes with eccentricity and meridian were qualitatively similar to that found for achromatic acuity at the majority of retinal locations. Like achromatic acuity, SWS acuity shows significant asymmetry at different retinal locations of equal eccentricity. This suggests that both the midget and small bistratified ganglion cell population density changes significantly with retinal location and eccentricity. SWS acuity appears to change in parallel with achromatic acuity for the majority of retinal locations measured, although the amount of nasotemporal asymmetry appears to be slightly less for the SWS system at 25- and 35-deg eccentricity.

Adult↗