The psychophysics of glaucoma: improving the structure/function relationship.

Abstract

Perimetry of some kind remains an important tool in the detection, diagnosis and monitoring of glaucomatous damage to the visual pathway. However, recent studies have served to reinforce the suspicion that conventional perimetry does not possess the sensitivity to detect the earliest signs of functional loss resulting from glaucoma. The relationship between differential light threshold and ganglion cell loss is extremely weak and, in the early stages of glaucoma, non-existent. Alternative, more novel perimetric techniques seem to offer promise of better detectability for early loss by claiming to tap in to one or other of the separate parallel pathways of the visual system. While some of these tests show potential for better detection and monitoring of glaucoma, the reasons why this might be so are not always clearly formulated or represented. This leads to misunderstanding of what the test actually measures and of the glaucomatous disease process itself. This paper seeks to revisit and review the theory underlying psychophysical testing of visual function related to glaucoma and stresses the importance of developing tests that are based on a firm theoretical understanding of visual function and processing in order to both detect glaucoma at an earlier stage and better understand the mechanisms of loss from the disease process.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roger S Anderson. 2005-08-02. The psychophysics of glaucoma: improving the structure/function relationship.. https://doi.org/10.1016/j.preteyeres.2005.06.001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗