PubMed Health⌕ Search

Biomedical subjects

Rupert Menapace

Publications and source records attributed to Rupert Menapace.

At least 19 recordsLinked to original sources

"Instant vision" compared with postoperative patching: clinical evaluation and patient satisfaction after bilateral cataract surgery.

PURPOSE: To compare two methods of postoperative dressing regimen: patching vs "instant vision" without patch. DESIGN: Prospective randomized clinical trial. METHODS: Sixty consecutive hospitalized, nonambulatory patients with cataract surgery under topical anesthesia on both eyes at different days were enrolled prospectively. In randomized order, one eye was patched for the first 24 hours postoperatively; the other eye was left open without patch to obtain "instant vision." Both eyes received the same anti-inflammatory and antibiotic drop therapy. RESULTS: Twenty-four hours postoperatively, no significant differences between patching and "instant vision" could be found for corrected and uncorrected visual acuity, corneal epithelial defects, conjunctival inflammation, anterior chamber flare, and intraocular pressure (P > .05). During the first 24 hours postoperatively, all tear film parameters were significantly worse in the "instant vision" eyes (P < .001), indicating a transient tear film instability. During the first four hours after cataract surgery, pain scores in the "instant vision" eyes were significantly higher than in the patched eyes (P < .001). Eight hours postoperatively and later, there were no significant differences in any pain scores (P > .05). After experiencing both methods, 27% of the patients subjectively rated the two methods as equivalent; 8% of the patients preferred "instant vision." Despite of the benefits of immediately improved orientation, 65% of the tested patients preferred patching to "instant vision" because of lower pain and foreign body sensations and psychologic arguments. CONCLUSIONS: The clinical examinations showed that both methods were equally safe for postoperative therapy. However, further efforts have to be made to increase the patients' comfort with "instant vision" in the first hours after cataract surgery.

Aged↗

Effect of optic material and haptic design on anterior capsule opacification and capsulorrhexis contraction.

PURPOSE: To examine the influence of optic material (silicone and hydrophobic acrylic) and haptic design (one-piece and three-piece open loop) of sharp optic edge intraocular lenses (IOL) on anterior capsule opacification (ACO) and capsulorrhexis contraction. DESIGN: Randomized, controlled, double-blind clinical trial with intraindividual comparison. METHODS: This study was performed at the Department of Ophthalmology, Medical University of Vienna, Austria, and comprised 210 eyes of 105 patients with bilateral age-related cataract. In group 1 (n = 53 patients), a three-piece acrylic IOL was compared with a three-piece silicone IOL. In group 2 (n = 52 patients), the three-piece acrylic IOL was compared with the one-piece acrylic IOL. One year after the operation, standardized digital slit-lamp images of ACO were taken; 1 week and 1 year after the operation, digital retroillumination images were taken to assess capsulorrhexis size. The intensity of ACO was graded objectively (score, 0% to 100%), and the capsulorrhexis area (square millimeters) was determined objectively. RESULTS: One year after surgery, the mean ACO score was 21% for the acrylic and 20% for the silicone IOL (P = .4) in group 1 and 18% for both the three-piece and one-piece acrylic IOLs (P = .87) in group 2. Concerning the amount of capsulorrhexis contraction, there was no significant difference between the IOL types that were evaluated in this study (after Bonferroni-Holm correction, P > .05). CONCLUSION: In the hydrophobic sharp optic edge IOLs that were examined, neither the optic material nor the haptic design had an influence on the amount of ACO or capsulorrhexis contraction.

Acrylic Resins↗

Routine posterior optic buttonholing for eradication of posterior capsule opacification in adults: report of 500 consecutive cases.

PURPOSE: To study the efficacy of posterior optic buttonholing (POBH) through a primary posterior capsulorhexis (PPCCC) to preserve full capsular transparency, and its potential as a routine alternative to standard in-the-bag implantation of sharp-edged optic intraocular lenses (IOLs). SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: After standard cataract removal, a PPCCC 4.0 to 5.0 mm in diameter was performed and the optic of a 3-piece IOL buttonholed posteriorly. One third of the eyes additionally had extensive anterior capsule polishing. All surgeries were performed under topical anesthesia. RESULTS: The first 500 consecutive surgeries were evaluated. In 11 eyes, POBH was not performed as planned. In 4 cases, anterior capsulorhexis fixation of the optic was used as an alternative. In the early series, vitreous entanglement was seen in 5 eyes, of which 1 case prompted translimbal anterior vitrectomy. No case of cystoid macula edema was observed. One case of peripheral retinal detachment in a highly-myopic eye 4 months postoperatively appeared to be unrelated to the surgery. All lenses were well-centered without tilt, and both capsule leaves remained clear especially after additional polishing. CONCLUSION: Posterior optic buttonholing precludes lens epithelial cells from accessing the retrolental space. The sandwiched posterior capsule blocks optic contact and thus fibrosis of the anterior capsule. Posterior optic buttonholing avoids after-cataract independent of optic edge design. Anterior capsule polishing adds to its efficacy by excluding any residual fibrosis. Surgery under topical anesthesia was well-controlled and safe. Posterior optic buttonholing may become a routine alternative to standard in-the-bag IOL implantation when supported by a longer follow-up.

Capsulorhexis↗

Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: three- and 5-year results of a randomized trial.

PURPOSE: To evaluate the long-term effects of anterior capsule polishing on regeneratory posterior capsule opacification (PCO), anterior capsule opacification (ACO), and fibrotic PCO with a silicone intraocular lens (IOL) with sharp optic edges. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This prospective bilateral randomized patient- and examiner-masked clinical trial comprised 130 eyes of 65 patients with bilateral age-related cataract. All eyes had implantation of a 3-piece silicone IOL with a truncated, sharp-edged optic (CeeOn Edge 911A, Advanced Medical Optics). In 1 eye, the anterior capsule was extensively polished using an aspiration curette after phacoemulsification and cortex aspiration. Regenerative PCO was quantified objectively, while ACO and fibrotic PCO were graded subjectively 1, 2, 3, and 5 years postoperatively. RESULTS: The mean ACO score was significantly lower in the eyes in which the anterior capsule had been polished (1 year, P<.02; 2 years, P<.03; 3 years, P<.01; 5 years, P<.01). The mean difference in regeneratory PCO and fibrotic PCO scores between the 2 groups was not statistically significant. CONCLUSIONS: Three years after cataract surgery, eyes in which the anterior capsule had been polished had significantly less ACO. However, polishing did not lower PCO intensity when a sharp-edged CeeOn 911A IOL was implanted in the bag. Although results indicate that anterior capsule polishing may enhance the development of regeneratory PCO, this trend did not reach statistical significance.

Cataract↗

Influence of infusion volume on the ocular hemodynamic effects of peribulbar anesthesia.

PURPOSE: To test the hypothesis that ocular blood-flow response to peribulbar anesthesia can be reduced by using a smaller volume of anesthetic mixture. SETTING: Departments of Ophthalmology and Clinical Pharmacology, Medical University of Vienna, Vienna, Austria. METHODS: Twenty patients scheduled for bilateral age-related cataract surgery were enrolled in a prospective randomized balanced observer-masked crossover study. Two study days with a 2 mL injection volume or 5 mL injection volume used for peribulbar anesthesia were scheduled. On 1 study day, patients received the 1-dose regimen and on the other study day, when the contralateral eye had surgery, patients received the other injection volume. On both study days, the anesthetic mixture consisted of an equal amount of lidocaine, bupivacaine, and hyaluronidase independently of the injection volume. Intraocular pressure (IOP), blood pressure, and pulse rate were measured noninvasively. Ocular fundus pulsation amplitude (FPA) and peak systolic and end diastolic flow velocities in the central retinal artery were measured with laser interferometry and color Doppler imaging, respectively. The results were recorded as means +/- SD. RESULTS: Peribulbar anesthesia increased IOP and reduced FPA and flow velocities in the central retinal artery. The effects on IOP (5 mL, 35.1% +/- 16.0%; 2 mL, 14.1% +/- 14.1%; P<.001) and ocular hemodynamic parameters (FPA: 5 mL, -17.5% +/- 7.8%/2 mL, -7.3% +/- 7.2%, P<.001; peak systolic velocity: 5 mL, -19.5% +/- 10.7%/2 mL, -10.6% +/- 9.8%, P = .013; end diastolic velocity: 5 mL, -16.7% +/- 6.2%/2 mL, -8.4% +/- 7.3%, P = .005) were more pronounced with the 5 mL injection volume than with the 2 mL injection volume. CONCLUSIONS: An injection volume of 2 mL instead of 5 mL reduced the ocular blood-flow response to peribulbar anesthesia. This procedure may be used in patients with ocular vascular disease to reduce the incidence of anesthesia-induced ischemia and loss of vision.

Aged↗

Aspiration curette for anterior capsule polishing: laboratory and clinical evaluation.

Capsular fibrosis or fibrotic after-cataract results from transdifferation of anterior lens epithelial cells into myofibroblasts with consequent contraction and collagen deposition. To avoid possible complications, an instrument was designed for efficient and safe polishing of the anterior capsule leaf. The curette features an upward-facing slit with sharp-edged flanks and rounded turning points and an optional bypass hole. It is introduced through 3 equidistant 20-gauge paracentesis openings. In a laboratory test, vacuum rise time and vacuum levels under occlusion and the effect of adding a bypass hole were investigated for various pump settings. In a clinical pilot series, efficiency and safety of various designs were tested and vacuum and flow settings titrated for optimum performance; the clinical effect was determined in prospectively randomized bilateral studies. Optimum pump settings were 5 mL/min and 10 mm Hg with the nonventing curette and 7 to 10 mL/min and 50 mm Hg with the venting curette. A bypass hole delayed the vacuum rise and reduced the mean vacuum level on full occlusion. It also allowed fine-tuning the vacuum at the slit by varying the flow rate with the foot pedal. Anterior capsule polishing significantly decreased capsule fibrosis and is recommended when posterior capsulorhexis and optic buttonholing are combined.

Epithelial Cells↗

Long-term effect of sharp optic edges of a polymethyl methacrylate intraocular lens on posterior capsule opacification: a randomized trial.

PURPOSE: To compare the posterior capsule opacification (PCO) inhibiting effect of a 3-piece polymethyl methacrylate (PMMA) intraocular lens (IOL) with a sharp optic edge design with that of the round-edged version of the same IOL during a 5-year period. DESIGN: Randomized patient- and examiner-masked clinical trial with intraindividual comparison. PARTICIPANTS: Thirty-two patients with bilateral age-related cataract (64 eyes). METHODS: Each study patient had phacoemulsification cataract surgery in both eyes and received a sharp optic edge PMMA IOL in one eye and a round optic edge PMMA IOL in the fellow eye (both by Dr Schmidt in Germany). Follow-up examinations were at 1 week, 1 month, 1 year, 3 years, and 5 years. Digital retroillumination images were taken from each eye. The amount of posterior capsule opacification was assessed objectively by means of automated image analysis software (Automated Quantification of After-Cataract) at 1 year, 3 years, and 5 years after surgery. MAIN OUTCOME MEASURE: Posterior capsule opacification score: 0-10. RESULTS: The sharp optic edge IOL showed significantly less regeneratory and fibrotic PCO at 1 year, 3 years, and 5 years after surgery. The mean AQUA PCO score was 5.12 for the round-edge and 2.49 for the sharp-edge IOL (scale, 0-10; P<0.001) at 5 years. The mean difference among patients for the PCO score in the eye implanted with the sharp optic edge versus the score in the eye with the round optic edge was 2.83 at 5 years (95% confidence interval, 1.66-4.00). Due to the large number of neodymium:yttrium-aluminum-garnet laser capsulotomies that were performed (12 in the round-edge group and 4 in the sharp-edge group), there was no significant difference in visual acuity between both groups at any time point. CONCLUSIONS: Compared with the round-edge version, the sharp optic edge design of a 3-piece PMMA IOL led to significantly less PCO at 1 year, 3 years, and 5 years after surgery. However, the sharp optic edge did not lead to complete PCO prevention during this follow-up period. This finding has implications for the design of PMMA IOLs used for cataract surgery, especially in the developing world.

Aged↗

Long-term efficacy of adding a sharp posterior optic edge to a three-piece silicone intraocular lens on capsule opacification: five-year results of a randomized study.

PURPOSE: To compare the intensity of capsule opacification with the sharp and the round optic edge variant of an open-loop hydrophobic silicone intraocular lens (IOL). DESIGN: Randomized, controlled, double-blind clinical trial with intraindividual comparison. METHODS: Fifty-one patients with bilateral age-related cataract were included (102 eyes). Each patient had had cataract surgery in both eyes and received a Microsil IOL with a sharp optic edge design (model S) in one eye and a Microsil IOL with a round optic edge design (model R) in the fellow eye. Both IOLs had an identical haptic design (nonangulated polymethylmethacrylate) and silicone optic material. The patients were examined at the slit lamp, best-corrected visual acuity was assessed, and standardized high-resolution digital retroillumination images of the posterior capsule were taken 5 years after surgery. The intensity of regeneratory posterior capsule opacification (rPCO), fibrotic PCO (fPCO), and anterior capsule opacification (ACO) was assessed subjectively at the slit lamp, and of rPCO, objectively using automated image analysis software (AQUA). The need for an Nd:YAG laser capsulotomy (Nd:YAG-LCT) was noted. RESULTS: The mean AQUA PCO score was 1.2 for the model S and 2.4 for the model R lens (P = .001). The model S lens also led to less peripheral fPCO (P = .003). Concerning ACO, there was no significant difference between both IOL groups (P = .72). Whereas no capsulotomy was required with the model S, four cases (16%) had been performed in the model R group. CONCLUSION: Five years postoperatively, the sharp-edged silicone IOL showed less rPCO and fPCO than the round-edged IOL. However, regarding ACO, there was no significant difference between both IOL styles.

Aged↗

Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification.

PURPOSE: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Sensar OptiEdge AR40e intraocular lens (IOL) with that of the double-round edge design of the Sensar AR40 IOL over a period of 3 years. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Fifty-three patients with bilateral age-related cataract (106 eyes) were included in this randomized prospective bilateral patient- and examiner-masked clinical trial with intraindividual comparison. Each study patient had cataract surgery in both eyes and received a Sensar AR40 IOL (anterior and posterior round optic edges) in 1 eye and a Sensar OptiEdge AR40e IOL (round anterior and sharp posterior optic edge) in the other eye. Follow-up examinations were at 1 week, 1 and 6 months, and 1, 2, and 3 years. Digital retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slitlamp and objectively using automated image-analysis software (AQUA) 1, 2, and 3 years after surgery. RESULTS: The sharp-edged AR40e lens showed significantly less regeneratory and fibrotic PCO 1, 2, and 3 years after surgery. The mean AQUA PCO score was 2.18 for the AR40 and 1.00 for the AR40e lens after 1 year; 2.94 and 1.56 after 2 years, and estimated at 3.13 and 1.77, respectively, after 3 years (scale 0 to 10; P<.001). The neodymium:YAG laser capsulotomy rate was significantly higher in the AR40 group. The AR40e lens also led to less peripheral fibrotic PCO. There was no significant difference in complaints concerning edge glare between the groups. CONCLUSION: Compared with the AR40 IOL, the sharp posterior optic edge design of the Sensar OptiEdge AR40e IOL led to significantly less PCO 1, 2, and 3 years postoperatively. In contrast with most past studies on PCO-preventative factors, this study varied only 1 parameter, namely the optic edge design, and the main outcome measure (PCO) was assessed with an objective image-analysis system.

Acrylic Resins↗

Pilocarpine-induced shift of an accommodating intraocular lens: AT-45 Crystalens.

PURPOSE: To measure the shift of an accommodating plate-haptic intraocular lens (IOL) along the visual axis induced by ciliary muscle contraction after application of pilocarpine. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Fifty-four eyes of 28 patients with age-related cataract comprised this prospective study. Each patient received an AT-45 silicone accommodating IOL (Crystalens, Eyeonics Corp.) after standardized cataract surgery. In a subgroup of 24 eyes, capsular bag fibrosis was reduced by extensive polishing of the anterior capsule with a slit cannula. Assessment included measurements of anterior chamber depth, assessed with partial coherence interferometry, before and after application of pilocarpine 2% and evaluation of near visual acuity 1 month and 3 months postoperatively. RESULTS: A slight backward shift of the IOL of 151 mum in the nonpolished group (P < .001) and 122 mum in the polished group (P < .005) could be detected after application of pilocarpine. Polishing the capsule did not influence IOL shift. The median near visual acuity with distance correction 1 month and 3 months postoperatively was J5 and J4, respectively, in the nonpolished group and J6 at both times in the polished group. CONCLUSIONS: Pilocarpine induced a counterproductive active backward shift of the AT-45 IOL. Polishing of the capsular bag had no impact on accommodative ability. The reading performance of patients with the AT-45 IOL patients at 1 and 3 months was not significantly different from that of with a standard IOL under similar testing methods.

Accommodation, Ocular↗

Influence of optic edge design, optic material, and haptic design on capsular bend configuration.

PURPOSE: To assess and classify capsular bend configuration at the optic rim and its association with posterior capsule (PCO) and anterior capsule opacification (ACO) and capsulorhexis contraction with various intraocular lenses (IOLs). SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: A total of 659 post-cataract surgery eyes of 370 patients from different prospective randomized studies were evaluated. All eyes had standardized phacoemulsification surgery with implantation of an IOL in the capsular bag. The IOLs had a sharp or round optic edge design and were made of silicone, acrylic, or poly(methyl methacrylate) optic materials. One year postoperatively, the configuration of the capsular bend at the optic rim was assessed at the slitlamp, and standardized slitlamp images of ACO and fibrotic PCO were taken. One week, 1 year, and 3 years postoperatively, digital retroillumination images were taken for objective quantification of regeneratory PCO and the capsulorhexis area. The outcome measures were the type of capsular bend configuration, ACO score (0% to 100%), regeneratory PCO score (0 to 10), fibrotic PCO score (0 to 3), and amount of capsulorhexis contraction (mm(2)). RESULTS: Four main types of capsular bend configuration were classified: parallel, "Y," right angle, and wrapping. The right-angle type was observed in the most cases (52%). Eyes with a wrapping capsular bend configuration had significantly less PCO, more capsulorhexis contraction, and more ACO than eyes with the other configurations. Wrapping capsule configuration was seen most often (55%) in round-edged silicone IOLs that had a thin optic rim. CONCLUSION: The design and material of IOLs influenced the long-term capsular bend configuration at the optic rim. The right-angle type was the most common capsular bend configuration. Intraocular lenses with silicone optic material and a thin optic rim caused a wrapping capsule configuration and resulted in more capsulorhexis contraction and ACO, but less PCO.

Biocompatible Materials↗

Long-term changes in the morphology of posterior capsule opacification.

PURPOSE: To classify the morphologic appearance of posterior capsule opacification (PCO) and to observe and document the changes over longer periods of time. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: Eighty-one pseudophakic eyes of 53 patients with PCO of varying degrees were included in this prospective study. Digital retroillumination images of the posterior capsule were taken in a standardized fashion 1, 2, and 3 years after cataract surgery. The PCO morphology was classified, and changes among the 3 follow-up images were analyzed. RESULTS: At 1, 2, and 3 years, pearls occurred in 16 (20%), 41 (51%), and 57 (63%) eyes. Pearls increased in size and number. Cases with thin layers of PCO decreased from 53 to 33 to 16 eyes. Conversely, cases with thick layers increased from 18 to 45 and 64 eyes. "Cheese holes" appeared most frequently as the predominant structure (range 47% to 51%), followed by plates (range 28% to 31%), islands (range 15% to 20%), and traces of PCO (range 1% to 5%). Changes in expansion of the PCO area were observed in 61 eyes (75%) during period 1 (1 to 2 years) and period 2 (2 to 3 years). Regions of expansion and regression in the same eye occurred in periods 1 and 2 in 11 eyes (14%) and 9 eyes (11%), respectively. The phenomenon of thinning bridges, a regression of syncytial extensions of PCO, occurred in 22 eyes (27%) and 32 eyes (40%), respectively. An overlapping growth of 2 layers was observed in 18 eyes (22%). CONCLUSIONS: The morphology of PCO is multifaceted. Apart from the Elschnig pearls, categories such as cheese holes, plates, islands, and traces of PCO were distinguished. Over the years, pearls increased in frequency, size, and number. Expansion and regression occurred simultaneously in some cases. Two or more layers grew on top of each other in some eyes.

Cataract↗

Effect of anterior capsule polishing on posterior capsule opacification and neodymium:YAG capsulotomy rates: three-year randomized trial.

PURPOSE: To compare the long-term effect of extensive polishing and nonpolishing of the anterior lens capsule on posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This prospective randomized bilateral double-masked study included 108 eyes of 54 consecutive patients with age-related cataract. Following phacoemulsification, 3-piece intraocular lenses (IOLs) with round-edged silicone optics were implanted. Patients received an Allergan SI-40 IOL with a truncated, round optic edge or a Domilens Silens6 IOL with a fully round optic edge. Patients were randomly assigned to have extensive anterior capsule polishing with the Menapace aspiration curette or no treatment in the first eye; the second eye received the opposite treatment. Digital retroillumination images were taken at 1 week, 1 year, and 3 years, and Nd:YAG capsulotomy rates were evaluated. Posterior capsule opacification was objectively scored using automated image analysis software (AQUA) or estimated based on clearly defined assumptions if a capsulotomy had been performed. RESULTS: Thirty-nine patients (78 eyes) concluded the study. Three-year PCO scores after polishing did not differ significantly (P>.05). However, 21 polished eyes (53.8%) required Nd:YAG laser capsulotomy compared with 14 nonpolished eyes (35.9%). The mismatch between PCO scores and Nd:YAG rates resulted from a change in PCO morphology that is not detected by scoring methods based on retroillumination photography but is visually disturbing to patients. CONCLUSIONS: Polishing the anterior capsule was effective in reducing fibrotic opacification but ineffective in reducing regeneratory opacification. Changes in regeneratory PCO morphology not picked up by retroillumination photography increased the need for Nd:YAG laser capsulotomy.

Cataract↗

Effect of optic material on posterior capsule opacification in intraocular lenses with sharp-edge optics: randomized clinical trial.

PURPOSE: Comparison of the intensity of posterior capsule opacification (PCO) between a silicone intraocular lens (IOL) and a hydrophobic acrylic IOL, both of them 3-piece and open-loop and having truncated optics with sharp edges. DESIGN: Randomized, controlled, patient- and examiner-masked trial with intrapatient comparison. PARTICIPANTS AND CONTROLS: One hundred six eyes of 53 patients with age-related bilateral cataract. METHODS: Each patient had cataract surgery in both eyes and received a silicone IOL in one eye and a hydrophobic acrylic IOL in the fellow eye. Follow-up examinations were at 1 and 3 years after surgery. The patients were examined at the slit lamp, visual acuity (VA) was assessed, and standardized high-resolution digital retroillumination images of the posterior capsule were taken. The amount of PCO was assessed subjectively at the slit lamp and objectively using automated image analysis software. Data of 56 eyes of 28 patients, who were examined at each follow-up, were analyzed. MAIN OUTCOME MEASURE: Posterior capsule opacification intensity at 3 years as measured with automated image analysis. RESULTS: At 1 and 3 years after surgery, PCO did not differ between the silicone (1.6 and 1.9 [image analysis scores, 0-10 scale], respectively) and acrylic IOLs (1.7 and 2.2) (P > 0.24). Furthermore, there was no significant difference in best-corrected VA, rhexis/IOL overlap, capsular folds, and amount of anterior capsule opacification during the follow-up period. In each group, one neodymium:yttrium-aluminum-garnet (YAG) laser capsulotomy was performed during the entire study duration. CONCLUSION: Silicone and hydrophobic acrylic are similarly effective in inducing the PCO-inhibiting effect of a rectangular, sharp optic edge. Three years after surgery, the PCO intensity and the YAG rate were low with both IOL models.

Acrylic Resins↗

Natural course of intraocular pressure after cataract surgery with sodium chondroitin sulfate 4%-sodium hyaluronate 3% (Viscoat).

PURPOSE: To investigate the natural course of intraocular pressure (IOP) and its peak after small-incision cataract surgery with chondroitin sulfate 4%-sodium hyaluronate 3% (Viscoat, Alcon Laboratories, Inc., Fort Worth, TX). DESIGN: Observational case series. PARTICIPANTS: This prospective study comprised 40 eyes of 40 consecutive cataract patients scheduled for small-incision cataract surgery. METHODS: Cataract surgery was performed with sodium chondroitin sulfate 4%-sodium hyaluronate 3% as the ophthalmic viscosurgical device, which was removed as completely as possible from the eye at the end of surgery. The IOP was measured preoperatively and 30 minutes; 1, 2, 3, 4, 6, 8, and 20 to 24 hours; and 1 week postoperatively. MAIN OUTCOME MEASURES: Postoperative IOP increase. RESULTS: The mean IOP increased significantly at all observation times during the first 20 to 24 hours, with a peak increase of 13.4+/-9.4 mmHg after 1 hour (P<0.05). In all, 28 eyes (70%) had an IOP spike to 30 mmHg or higher. Sixty-eight percent of these spikes occurred at 30 minutes as well as at 1 hour and 2 hours postoperatively. At 20 to 24 hours, no eye had an IOP spike to 30 mmHg or higher. CONCLUSIONS: Significant IOP increases were found during the first 24 hours, peaking at 1 hour after surgery. With a single postoperative IOP measurement, between 30 minutes and 2 hours after surgery, two thirds of these IOP spikes could be detected. To detect all IOP spikes, a second measurement between 4 and 6 hours after surgery would be necessary.

Aged↗

Influence of optic edge design and anterior capsule polishing on posterior capsule fibrosis.

PURPOSE: To evaluate the role of posterior optic edge design and the effect of anterior capsule polishing on peripheral fibrotic posterior capsule opacification (PCO). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This randomized prospective study comprised 144 eyes of 72 patients with bilateral age-related cataract. Each patient had standardized cataract surgery in both eyes by the same surgeon. Group 1 (46 patients) received a round-edged hydrophobic acrylic IOL (AMO Sensar AR40) in 1 eye and a sharp-edged hydrophobic acrylic IOL (AMO Sensar OptiEdge AR40e) in the other eye. Group 2 (26 patients) received a silicone IOL (Pharmacia CeeOn 911A) with a truncated optic in both eyes. In this group, the anterior capsule was extensively polished in 1 eye and was left unpolished in the other eye. Digital slitlamp photographs were taken 1 year postoperatively using a standardized photographic technique for fibrotic PCO. The intensity of PCO was subjectively graded (score 0 to 4) by 2 masked examiners. RESULTS: Subjective PCO scores correlated well between the 2 examiners (r = 0.88). In Group 1, the mean PCO score was 0.26 for the OptiEdge AR40e IOL and 0.90 for the AR40 IOL (P<.01). In Group 2, the mean PCO score was 0.24 in eyes with a polished capsule and 0.17 in eyes in which the capsule was not polished (P =.31). CONCLUSIONS: The sharp-edged OptiEdge AR40e IOL led to significantly less peripheral fibrotic PCO 1 year postoperatively than the round-edged AR40 IOL. In eyes with the sharp-edged silicone 911A IOL, anterior capsule polishing caused no significant difference in fibrotic PCO.

Acrylic Resins↗

Effect of intraocular lens optic edge design and material on fibrotic capsule opacification and capsulorhexis contraction.

PURPOSE: To examine the influence of intraocular lens (IOL) optic edge design and optic material on fibrosis of the anterior and peripheral posterior capsules and on capsulorhexis contraction. SETTING: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. METHODS: This randomized controlled patient- and examiner-masked study comprised 210 eyes of 105 patients with bilateral age-related cataract. In Group 1 (n = 53), the Sensar OptiEdge AR40e hydrophobic acrylic IOL with a sharp posterior optic edge was compared with the AR40 acrylic IOL with a round edge. In Group 2 (n = 52), the ClariFlex OptiEdge silicone IOL with a sharp posterior optic edge was compared with the PhacoFlex SI-40 silicone IOL with a round edge All IOLs were manufactured by Advanced Medical Optics, Inc. Standardized digital slitlamp images of anterior capsule opacification (ACO) and fibrotic posterior capsule opacification (PCO) were taken 1 year postoperatively, and digital retroillumination images were taken at 1 week and 1 year. The intensity of fibrotic PCO was graded subjectively (score 0 to 4), ACO was graded objectively (score 0% to 100%), and the capsulorhexis area (mm(2)) was determined objectively. RESULTS: One year after surgery, the mean ACO score was 32% in eyes with the sharp-edged acrylic IOL and 29% in eyes with the round-edged acrylic IOL (P<.05). In the silicone group, the mean was 31% and 26%, respectively (P<.05). The mean fibrotic PCO score was lower in eyes with a sharp-edged acrylic IOL than in eyes with a round-edged acrylic IOL (0.26 and 0.93, respectively; P<.05) and in eyes with a sharp-edged silicone IOL than in eyes with a round-edged silicone IOL (0.24 and 0.82, respectively; P<.001). At 1 year, the mean capsulorhexis area was statistically significantly smaller in eyes with a sharp-edged silicone IOL than in eyes with a round-edged silicone IOL (P<.05). CONCLUSIONS: Acrylic and silicone IOLs with the sharp OptiEdge design led to significantly less fibrotic PCO but more ACO than round-edged acrylic and silicone IOLs. The sharp-edged silicone IOL caused significantly more capsulorhexis contraction than the round-edged silicone IOL and both acrylic IOLs.

Acrylic Resins↗

Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification.

PURPOSE: To compare the inhibiting effect on posterior capsule opacification (PCO) of a silicone intraocular lens (IOL) with a sharp posterior optic edge (ClariFlex OptiEdge, Advanced Medical Optics) and a silicone IOL with a round optic edge (PhacoFlex SI-40, Advanced Medical Optics). SETTING: Department of Ophthalmology, University of Vienna, Vienna, Austria. METHODS: This prospective randomized patient- and examiner-masked study comprised 104 eyes of 52 patients with bilateral age-related cataract. All patients had cataract surgery in both eyes and received a sharp-edged IOL in 1 eye and a round-edged IOL in the other eye. Postoperative examinations were at 1 week, 1 and 6 months, and 1 year. Digital slitlamp and retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slitlamp and objectively using Automated Quantification of After-Cataract (AQUA) automated-image analysis software. RESULTS: The sharp-edged IOL group had significantly less regeneratory and fibrotic PCO 1 month, 6 months, and 1 year after surgery. The mean AQUA PCO score (scale 0 to 10) was 0.71 in the sharp-edged IOL group and 1.40 in the round-edged IOL group (P<.001). The sharp-edged IOL group had less peripheral fibrotic PCO. There was no significant difference between the 2 IOL groups in patient reports of edge glare. CONCLUSION: The sharp-edged design of the ClariFlex OptiEdge silicone IOL led to significantly less PCO than the round-edged PhacoFlex SI-40 IOL 1 year postoperatively.

Aged↗