Digital imaging of the chest.

The development of effective methods for producing digital chest radiographs is essential if the totally digital radiology department of the future is to evolve. Digital radiography of the chest is now possible with a variety of techniques. The most promising approach currently in clinical use involves the use of large-area detectors composed of photostimulable phosphors read with a laser to produce high-quality digital chest images. Image processing to modify contrast and latitude of the image display as well as enhancement of selected spatial frequencies and energy subtraction is possible with digital chest radiography. The wide exposure latitude of digital image receptors may allow useful images to be obtained with significantly smaller exposure doses than those required in conventional techniques and may also be used to compensate for inadvertent overexposure, eliminating the need for repeat examinations because of errors in exposure technique. Limitations of many current systems result from inadequate resolution provided by CRT display monitors. The production of hard copy images by laser printer on small format film overcomes this problem, allowing application of digital techniques for chest radiology to be incorporated into clinical practice with images comparable in spatial resolution to those of film-screen systems.

Fluoroscopy↗

Digital subtraction angiography: fundamental noise characteristics.

Detectability of low-contrast objects (vessels) in subtraction imaging depends on the noise properties of the image. There is a structure imposed upon the quantum noise that is due to the attenuation of the subtracted background object; this structure is referred to as a "noise print." It is shown to be a function of the manner of presubtraction processing (linear or logarithmic) and the local thickness of the attenuator in the x-ray beam path. The influence of the noise print on the visibility of vessels in subtraction images is demonstrated.

Angiography↗

[Roentgen pictures in the digital image].

In addition to computed tomography which presents actually the most important processing and transfer procedure of digital X-ray images, application of real time addition and subtraction of X-ray images in a digital mode has found considerable interest. An estimation of the information contents of both digital and analog images is made in close relation to applications. As example of an image processing system on digital base a recently developed system for intravenous arteriography is described: the Philips-DVI.

Angiography↗

Topometric, roentgenologic, laboratory and clinical criteria of tumor regression in conservative management of prostatic carcinoma.

The assessment of prostatic carcinoma management results requires a complex approach. It is necessary to consider the objective criteria of tumor regression in the primary tumor and metastases to soft tissue, bone as well as indirect signs of tumor process (levels of acid and alkaline phosphatases). Subjective response cannot be assessed accurately. Reliable criteria in prostatic cancer management are: (1) objective regression by 50% or more decrease in all measurable lesions and unequivocal improvement in evaluable but non-measurable lesions with no new lesions developing; (2) Ultrasonotomography is a fine method of objective response assessment in the primary tumor and metastases; (3) Duration of response is the important criteria of tumor regression in conservative management of prostatic carcinoma.

Clinical Laboratory Techniques↗

Radiation exposure to the operator performing cardiac angiography with U-arm systems.

We measured the radiation exposure received by a group of operators performing 700 coronary angiograms. All studies were performed using the brachial artery approach and the Philips Cardio Diagnost. Nineteen sites were monitored on each operator, using lithium fluoride thermoluminescent dosimeters. Four hundred examinations were performed with a table-mounted protective shield in place. Three hundred were performed without the shield. The average exposures (in mR per study) with and without the shield were 1.9/6 for the eyes and 1.4/8.3 for the thyroid. The resulting operator exposure with the shield in place is low enough so that an operator performing 25 procedures per week on a continuous basis will not exceed the recommendations of the National Commission on Radiological Protection and Units. We therefore strongly recommend the use of properly designed and appropriately positioned shield with all U-arm systems.

Angiography↗

The use of photochromic eyeglasses by radiologists.

Photochromic lenses which undergo a change in density with varying intensities of sunlight have been incorporated into routine eyeglasses. Laboratory tests have shown that glasses of this type do not decrease the visual acuity of the radiologist.

Eyeglasses↗