Digital images.

This tutorial introduces basic digital image processing concepts. An increasing fraction of fluoroscopic images are handled and processed using digital tools. The quality of an image in digital format depends on both the technical details of the digitization process and on the quality of the starting scene. Digital tools yield images that are difficult or impossible to achieve using analog techniques. Proper processing improves the observer's perception of clinical information.

Analog-Digital Conversion↗

Cine PACS: preprint.

The technology of cardiac image management is increasingly digital. This tutorial introduces some of the basic concepts relevant to the application of this technology in the cardiac catheterization laboratory.

Cardiac Catheterization↗

Radiation safety in the cardiac catheterization laboratory: operational radiation safety.

The goal of the catheterization laboratory radiation safety program is to facilitate invasive cardiology while simultaneously reducing staff risks to an acceptable level. Achieving this goal requires a balance between the value of catheterization to the patient and the associated radiation risk to the staff. This article introduces the principles of radiation protection as applied in the catheterization laboratory. Prudent conformance to these principles will appropriately reduce radiation risk. Cathet. Cardiovasc. Intervent. 47:347-353, 1999.

Air Pollution, Radioactive↗

An overview of radiation safety regulatory recommendations and requirements.

This article reviews the formal basis of radiation protection programs. It also reviews the application of these programs in the cardiac catheterization laboratory. Radiation protection rules are based on epidemiology, radiobiology, and radiation physics. Applicable scientific results are periodically reviewed by committees reporting to the United States National Academy of Science and to the United Nations. National and international expert committees convert science to recommendations. The legislative process enacts enforceable regulations. These regulations need to be interpreted in relation to the actual risks experienced by the fluoroscopist.

Female↗

Endovascular brachytherapy: physics and technology.

Brachytherapy is the placement of radiation sources (usually radioactive materials) in or near a target tissue. This paper introduces the physics and technology needed to perform endovascular brachytherapy. Three main delivery systems under investigation are low activity radioactive stents; high activity solid-sources; and high activity gas or liquid filled balloons. A wide range of radionuclides is under consideration for each of these systems. There are fundamental differences in both the local and long-range distribution of radiation around beta or gamma emitting sources. Devices in the microCi range are permanently implanted. Devices in the mCi range are inserted for a few minutes. Both beta and gamma sources can be extremely dangerous if they are mishandled.

Arterial Occlusive Diseases↗

Imaging factors and image optimization.

Optimization of dose and image quality is task-dependent. The three main image quality parameters, sharpness, contrast, and noise, are interdependent in radiographic systems. The need to minimize patient dose imposes further couplings between these factors. This is the reason why there are no universally applicable imaging systems.

Radiographic Image Enhancement↗

Hematocrit as a predictor of significant injury after penetrating trauma.

A study was undertaken to determine if there are differences in hematocrit (HCT) during the initial evaluation of patients with and without significant visceral intrathoracic or intraabdominal injury after penetrating trauma and, if so, the predictive value of this parameter. Sixty consecutive adults with potentially significant penetrating trauma who presented to an urban municipal trauma center during a 10-week period were studied. Diagnostic variables were recorded for all patients at risk for significant injury, defined as intrathoracic or intraabdominal injury requiring surgical intervention. Patients were ultimately grouped on the basis of operative findings or observation to discharge. Acquired variables included vital signs, initial HCT (HCT-0), HCT at 15 minutes (HCT-15), HCT at 30 minutes (HCT-30), and fluid administered. Twenty-one patients had significant injuries (INJ), and 39 did not (NO-INJ). INJ patients had lower HCT values than NO-INJ on presentation (35% +/- 6% and 41% +/- 5%, respectively). At presentation, a low HCT was predictive of significant injury, but a normal HCT did not preclude injury. The changes in HCT from arrival to 15 minutes, between INJ and NO-INJ patients, were similar (-1.5% +/- 3% and -0.6% +/- 3% respectively). Only when the decrease in HCT was > or =6.5% from presentation measurements was it predictive of injury. During the first 15 minutes a decrease in HCT of > or =6.5% had a positive predictive value and specificity of 1.0. The change in HCT between 15 and 30 minutes was less useful. There was a large difference between the amounts of fluid given to injured and uninjured patients, which may have been responsible for some of the differences in HCT between the two groups. These results show that HCT may have some diagnostic utility during the early management of penetrating trauma. Presentation with an HCT below normal, or an early decrease in HCT, is an indicator of potential injury. Although many patients with serious internal injuries do not manifest large decreases early after presentation, those who do have a high probability of internal injury. The lower the HCT, or the greater the decrease, the greater the probability that a significant injury exists.

Abdominal Injuries↗

Guidelines for personnel radiation monitoring in the cardiac catheterization laboratory. Laboratory Performance Standards Committee of the Society for Cardiac Angiography and Interventions.

The Laboratory Performance Standards Committee of the Society for Cardiac Angiography and Interventions has devised guidelines to inform catheterization laboratory personnel about appropriate radiation monitoring and protection. A personal monitoring dosimeter must be placed over any radiation protective garments on the collar near the thyroid. A second dosimeter, worn at the waist level under any radiation protective garments, is mandatory for any declared pregnant workers exposed to radiation. This dosimeter is recommended, but not required, for all personnel in the catheterization laboratory. The limit for whole body radiation exposure is stated in terms of the effective dose equivalent (EDE). Different formulas are used for calculating the EDE, depending on the number of dosimeters worn simultaneously by the individual. Finger dosimeters should be worn by personnel whose hands are likely to be directly exposed to the x-ray beam. Initial and periodic training in radiation protection is a part of good laboratory practice.

Cardiac Catheterization↗

Fundamental properties of digital images.

The quality of a digital image is affected by matrix size, unsharpness in the underlying image, bit depth, and noise in the underlying image. The array of all of the pixels into which an image is divided is the image matrix. If the image matrix is small (ie, composed of a few large pixels), the resolution of the digital image is low. Image blur dominates when the pixel size is much smaller than the unsharpness of the underlying image. The density in a pixel is represented by a binary number with a variable number of bits (bit depth). The more noise present in the initial image, the fewer the bits that are needed to convey its representation. Insufficient numbers of bits in the digital representation of an image, whether from too few pixels or too small a bit depth in each pixel, result in inadequate image quality. Use of too many bits, relative to the quality of the underlying image, places an increasingly unwarranted demand on digital image handling and processing.

Analog-Digital Conversion↗

Review of radiation safety in the cardiac catheterization laboratory.

With the increasing use of coronary arteriography and interventional procedures, radiation exposure to patients and personnel working in cardiac catheterization laboratories has increased. Proper technique to minimize both patient and operator exposure is necessary. A practical approach to radiation safety in the cardiac catheterization laboratory is presented. This discussion should be useful to facilities with well-established radiation safety programs as well as facilities that require restructuring to cope with the radiation environment in a modern cardiac catheterization laboratory.

Cardiac Catheterization↗

Cardiac catheterization laboratory survey: 1990. Society for Cardiac Angiography and Interventions, Laboratory Performance Standards Committee.

A survey of 117 member cardiac catheterization laboratories was undertaken by the Society for Cardiac Angiography and Interventions. The survey included numbers and types of procedures, both diagnostic and interventional, in adult as well as pediatric age groups. Radiation safety, various laboratory policies, frequency of short stay, and outpatient procedures were tabulated. Report generation, training programs, administrative organization, and laboratory equipment were all included. The results were compared with a 1978 survey. Areas of concern in terms of safety of the patient and possible underutilization of laboratories were identified.

Angioplasty, Balloon, Coronary↗

Optimizing radiologic costs in the DRG environment.

Previously developed consensus algorithms expressing a suggested radiologic workup for the diagnostic related groups (DRGs) specified by the prospective reimbursement policy have proven to be useful tools for investigating radiologic decision making and the resulting economic implications. The mathematical equations for determining diagnostic and therapeutic costs for two alternative algorithms for suspected acute cholecystitis are formulated. Illustrative examples and graphic displays are given regarding how such algorithms and equations are useful in finding answers to questions about the appropriate diagnostic workup, time, and cost. Exploration of the effect of different parameter values on the choice of the appropriate algorithm is illustrated.

Algorithms↗

Diagnostic protocols for radiologic efficiency.

Starting January 1988, New York State started an all-payor prospective reimbursement for inpatient hospitalizations. Medicare had already adopted a prospective reimbursement system for its patients during the previous year. This article reviews our departmental efforts to prepare for the consequences of these new policies.

Algorithms↗