PubMed Health⌕ Search

Biomedical subjects

S Feuerbach

Publications and source records attributed to S Feuerbach.

At least 55 records · Page 3Linked to original sources

[Percutaneous therapy of inoperable biliary stenoses and occlusions with a new self-expanding nitinol stent (SMART)].

OBJECTIVE: To evaluate the treatment of malignant biliary stenoses and occlusions using a new stent. METHODS: In a prospective study, 25 patients with malignant obstructive jaundice were treated with SMART(R) stents. The handling and the quality of stent expansion were documented. Stent function was assessed 2 - 4 days after intervention by cholangiography and laboratory tests. A follow-up was performed three months, after stent placement. RESULTS: All lesions were treated successfully, with a total of 35 stents implanted. In 14 patients a further balloon dilatation was performed after stent placement (8 - 10 mm diameter/ 40 - 80 mm length). The mean serum bilirubin level decreased significantly from 11.6 mg/dl to 4.6 mg/dl after intervention (p < 0.05). The follow-up showed a mean serum bilirubin level at 4.0 mg/dl. In 4 cases (16 %) a further intervention (PTCD or stent) was performed. Six patients died due to tumor progression. The stents proved to be patent in 79 % (n = 15) of patients alive at the time of follow-up. CONCLUSIONS: Placement of the SMART stent for the therapy of malignant biliary lesions yields good technical and clinical results.

Aged↗

MR imaging of cranial nerve lesions using six different high-resolution T1- and T2(*)-weighted 3D and 2D sequences.

PURPOSE: To find a suitable high-resolution MR protocol for the visualization of lesions of all 12 cranial nerves. MATERIAL AND METHODS: Thirty-eight pathologically changed cranial nerves (17 patients) were studied with MR imaging at 1.5 T using 3D T2*-weighted CISS, T1-weighted 3D MP-RAGE (without and with i.v. contrast medium), T2-weighted 3D TSE, T2-weighted 2D TSE and T1-weighted fat saturation 2D TSE sequences. Visibility of the 38 lesions of the 12 cranial nerves in each sequence was evaluated by consensus of two radiologists using an evaluation scale from 1 (excellently visible) to 4 (not visible). RESULTS: The 3D CISS sequence provided the best resolution of the cranial nerves and their lesions when surrounded by CSF. In nerves which were not surrounded by CSF, the 2D T1-weighted contrast-enhanced fat suppression technique was the best sequence. CONCLUSIONS: A combination of 3D CISS, the 2D T1-weighted fat suppressed sequence and a 3D contrast-enhanced MP-RAGE proved to be the most useful sequence to visualize all lesions of the cranial nerves. For the determination of enhancement, an additional 3D MP-RAGE sequence without contrast medium is required. This sequence is also very sensitive for the detection of hemorrhage.

Contrast Media↗

Evaluation of arterial bypass grafts of the pelvic and lower extremities with gadolinium-enhanced magnetic resonance angiography: comparison with digital subtraction angiography.

RATIONALE AND OBJECTIVES: The aim of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) with digital subtraction angiography (DSA) in the assessment of patency and stenoses in bypass grafts. METHODS: Fifteen patients were examined with both CE MRA and DSA. Fifteen bypass grafts were evaluated by four readers for potential stenosis in five locations. The stenoses were classified in five types: 1 (0% to 24% stenosis), 2 (25% to 49%), 3 (50% to 74%), 4 (75% to 99%), and 5 (occlusion). RESULTS: Using both techniques, 70 of 75 evaluated locations (93.3%) were classified identically. This included six stenoses < 50% and six stenoses > 50%, respectively. Four of five overestimations of stenoses were scaled in DSA as stenoses type 1. One stenosis was categorized as type 3 in DSA. Sensitivity for CE MRA for detecting stenoses >or= 25% was 100% and the specificity 90%. Interobserver agreement for all evaluations was 0.77 (Spearman rank correlation test). CONCLUSION: In the assessment of low-grade stenosis in bypass grafts, CE MRA overestimates stenoses slightly but yields good results in comparison with DSA.

Angiography, Digital Subtraction↗

Laser surgical planning with magnetic resonance imaging-based 3-dimensional reconstructions for intralesional Nd:YAG laser therapy of a venous malformation of the neck.

BACKGROUND: Three-dimensional (3-D) imaging using computed tomography or magnetic resonance imaging data is well known for surgical planning of complex lesions in neurosurgery. In dermatology, percutaneous and intralesional Nd:YAG laser therapy is well established for numerous types of vascular malformations. Diagnostic imaging using ultrasound, computed tomography, or magnetic resonance imaging is necessary to plan the laser therapy of those malformations. The therapeutic problem is to localize the venous malformation exactly before treatment on sectional 2-dimensional images. OBSERVATIONS: We describe a 27-year-old woman with a venous malformation of the neck. The data of diagnostic magnetic resonance imaging were used for a 3-D reconstruction of the venous malformation to demonstrate the anatomical extent and subcutaneous involvement for laser surgical planning. Percutaneous and intralesional laser therapy was performed at 3-month intervals with the Nd:YAG laser using the 3-D reconstruction as a road map for the Nd:YAG laser. Eight weeks after the last laser treatment, the bulky lesions of the neck showed regression. Using the 3-D reconstruction for laser surgical planning, physicians could perform intralesional laser treatment more exactly. The complex anatomy of the venous malformation could be elucidated by studying the 3-D images before and during laser surgery. CONCLUSION: The use of magnetic resonance imaging-based 3-D reconstructions for laser surgical planning can demonstrate the often unexpected extent and improve the intralesional laser therapy in the treatment of venous malformations.

Adult↗

Dynamic magnetic resonance imaging defecography: a diagnostic alternative in the assessment of pelvic floor disorders in proctology.

PURPOSE: Standard diagnostic proctologic procedures in the assessment of pelvic floor disorders include clinical evaluation and endoscopy. Particular aspects of combined pelvic floor disorders, especially those involving more than one pelvic compartment, may remain undetected without additional technical diagnostic procedures such as videoproctoscopy, cinedefecography, or colpocystodefecography. The aim of the study was to review the potentials of dynamic magnetic resonance imaging defecography to elucidate the underlying anatomic and pathophysiologic background of pelvic floor disorders in proctologic patients. PATIENTS AND METHODS: Dynamic magnetic resonance imaging defecography was performed in 20 Patients (13 females) with main diagnoses such as rectal prolapse or intussusception, rectocele, descending perineum, fecal incontinence, outlet obstruction, and dyskinetic puborectalis muscle after clinical evaluation. The investigation was performed on a 1.5 T-magnetic resonance imaging machine in supine position. The rectum was filled with Gd-DTPA enriched ultrasound gel. First a T1/T2 weighted investigation of the pelvis was performed, followed by defecography with evacuation of the rectum. Images were obtained in a sagittal plane in a frequency of 1 image/second (true FISP) at rest and during straining. The obtained magnetic resonance imaging video tapes were analyzed off-line with cinematographic evaluation of bladder base, uterus, and anal canal position in relation to the pubococcygeal line by a blinded radiologist. Investigation time was 20 minutes. RESULTS: In dynamic magnetic resonance imaging defecography of the pelvic floor, 12 patients with descending perineum, 10 rectoceles (10 females), 6 cystoceles (6 females), 4 enteroceles (4 females), 8 intussusceptions (5 females), and a dyskinetic puborectalis muscle in 3 males were detected. In 11 females and 3 males multifocal disorders were found, involving more than one compartment in females, whereas in males complex defects were restricted to the posterior compartment. Magnetic resonance imaging defecography revealed diagnoses consistent with clinical results in 77.3 percent and defects in addition to clinical diagnoses in combined pelvic floor disorders in 34 percent. CONCLUSIONS: In complex pelvic floor disorders, involving more than a single defect, dynamic magnetic resonance imaging represents a convenient diagnostic procedure in females and to a lesser extent in males, in particular in terms of dynamic imaging of pelvic floor organs during defecation. In addition to the clinical assessment, dynamic magnetic resonance imaging had clinical impact in proctologic and interdisciplinary treatment.

Adult↗

Frequency of benign hepatic lesions incidentally detected with contrast-enhanced thin-section portal venous phase spiral CT.

PURPOSE: To evaluate the frequency of benign focal hepatic lesions incidentally detected at contrast-enhanced thin-section portal venous phase spiral CT. MATERIAL AND METHODS: Between January 1998 and February 1999, contrast-enhanced hepatic spiral CT examinations were performed in 1,892 patients. Out of these, only 100 patients fulfilled the following inclusion criteria: No underlying malignant disease, no liver cirrhosis, no suspected or known focal liver lesions. Standardized spiral CT parameters were applied. All CT studies were reviewed retrospectively by one radiologist. Any focal lesion was recorded and classified. Lesion size and number were noted. RESULTS: A total of 108 hepatic lesions were reported in 33 out of 100 patients (80 cysts; 18 hemangiomas; 3 focal fatty infiltrations; 2 focal non-tumorous perfusion defects; 1 calcification; and 4 non-classified lesions). The average lesion size was 9.4 mm (< or =5 mm: n=40; 6-10 mm: n=30; 11-15 mm: n=28; >15 mm: n=10). CONCLUSION: Benign liver lesions are probably a frequent incidental finding at abdominal spiral CT.

Adult↗

[Percutaneous transpapillary extraction of biliary calculi for symptomatic choledocholithiasisafter unsuccessful endoscopic treatment].

PURPOSE: Evaluation of a percutaneous transhepatic treatment of symptomatic choledocholithiasis in bile ducts that cannot be reached with the endoscope. METHODS: From January 1996 to August 2000 a transhepatic extraction of biliary calculus was performed in four patients. Endoscopic retrograde cholangiography (ERC) was not successful in any of the cases. Clinical symptoms were icterus in four cases, additional cholangitis or colics in two cases. First, a balloon dilation of the papilla was performed by a percutaneous transhepatic approach. For removal of bile duct stones, occlusion catheters and Dormia baskets were used. Technical success was defined as complete removal of bile duct stones. Clinical success was defined as normalization of cholestasis and inflammation parameters. In the follow-up an ultrasound examination was performed and blood samples were taken for control of cholestasis parameters. RESULTS: In all four cases treatment was technically and clinically successful. For complete removal of biliary calculus a second intervention was necessary in two cases. In each case an internal to external drainage was left over a mean of 7 days (3-13 days). In the mean follow-up of 30.5 months (6-50 months) all patients had persistent relief of symptoms. No further interventions were necessary. No complications were present. CONCLUSION: Percutaneous transpapillary extraction of biliary calculus is an effective alternative to surgery in patients with bile ducts, that cannot be reached with the endoscope.

Aged↗

[The PACS concept of the University of Regensburg].

AIM: Planning a PACS (Picture Archiving and Communication System) with the aim of a filmless hospital. The service for the referring physicians should be optimised. METHODS: Statistical analysis of data from the RIS (Radiological Information System), customer survey, workflow analysis and cost effectiveness analysis was the basis for planning the PACS. RESULTS: The calculated data quantity of the institute is 6.2 gigabyte per day or 1.7 terabyte per year. The referring physicians wanted to have the examination in 93% of the cases on the same day. For 53% of the cases remote studies were necessary for reading. Only 2.3% of these pictures were older than two years. The organisation of the department makes it necessary to have access to the examination of all modalities from each diagnosis workstation. CONCLUSIONS: Due to specific attributes of the institute, a fast nearline archive, a clustering of the diagnosis workstations and a DiCOM based picture distribution were planned.

Cost-Benefit Analysis↗

[Dynamic MR defecography for diagnosis of combined functional disorders of the pelvic floor in proctology].

PURPOSE: Evaluation of magnetic resonance defecography in the diagnosis of pelvic floor disorders were examined prospectively. MRI was performed on a 1.5 T scanner. The rectum was opacified with 200 ml of ultrasound transmission gel. A sagittal single section T2-weighted gradient echo sequence with a temporal resolution of 1.1 second was performed. Changes of the anorectal angle and the position of the pelvic organs in relation to the pubococcygeal line were registered at rest, during straining, and during evacuation of the rectum. RESULTS: Patients with obstructed defecation (n = 15) showed prolapse of the rectal mucosa (n = 5), anterior rectocele (n = 8), pelvic floor descent (n = 5), enterocele (n = 2), and anorectal dyscoordination (n = 3). Individuals with stool incontinence (n = 15) had an anterior rectocele (n = 10), pelvic floor descent (n = 11), enterocele (n = 2), prolapse of rectal mucosa (n = 1), and a puborectal insufficiency (n = 1). Urine incontinence was associated with cystocele (n = 10) or normal findings (n = 4). In patients with unspecific symptoms (n = 6), anorectal dyscoordination (n = 4) and prolapse of the rectal mucosa (n = 2) were found. MRI was superior for the detection of enteroceles, cystoceles and pelvic floor descent compared with clinical investigation. CONCLUSION: Dynamic MR imaging supplies complex information in anorectal disease and thus improves proctoscopy.

Adolescent↗

[Percutaneous transfemoral implantation of a new, flexible thoracic aorta endoprosthesis using a percutaneous suture system for vascular suture--initial experiences].

PURPOSE: To evaluate the transfemoral placement of a new, flexible stent-graft into the thoracic aorta and the suture-mediated closure of the femoral access. PATIENTS AND METHODS: Five patients were treated endovascularly with a stent-graft for an aneurysm (n = 3) or acute dissection (n = 2) of the thoracic aorta via a femoral 24 F sheath. The femoral access site was closed with two suture-mediated closure devices after placement of the stent-graft. RESULTS: The aneurysm or the false lumen was excluded from perfusion by the placement of the stent-graft in all patients. Hemostasis at the femoral access site was successful in all patients with the percutaneous suture device. A minor stenosis of the femoral artery was found angiographically in four patients after suture-mediated closure. Besides a reversible renal failure due to the medically induced hypotension for the treatment of an acutely ruptured aneurysm, no complications resulted from the stent-graft placement or the percutaneous suture. CONCLUSION: The percutaneous transfemoral placement of stent-grafts in the thoracic aorta using a suture-mediated closure of the access site is technically feasible. Long-term results of the technique have to be awaited.

Aged↗

[Treatment of para-ostium renal artery stenoses with a new, solidly premounted balloon expandable stent].

PURPOSE: Evaluation of the handling, technical success rate, and six-months patency rate of a new, premounted balloon-expandable stent in ostial renal artery stenoses. MATERIAL AND METHODS: In a prospective study, 27 ostial renal artery stenoses in 20 patients were primarily treated with the new "Renal Bridge Stent" (Medtronic AVE, Düsseldorf). All patients had a history of hypertension and 8 patients had renal dysfunction. The handling and visibility of the stent was scored on a three grade scale by the operators. Follow-up angiography including intra-arterial trans-stenotic pressure measurements was performed in 23 out of 27 stenoses (17 patients). RESULTS: Handling and visibility were scored as good by all operators. 26 of 27 stenoses were treated with technical success by implantation of 28 stents. The mean degree of stenosis was reduced from 74.2% to less than 5%. At 6 months, 8 stents out of 23 (35%) showed a significant in-stent stenosis (stenosis degree > 50% and intra-arterial pressure gradient > 10 mmHg). The stenosis rates were 63% using 5-mm stents, 30% using 6-mm stents, and 0% using 7-mm stents. CONCLUSION: Endovascular treatment of ostial renal artery stenosis with the used stent is safe and effective. The new stent shows a good handling and visibility. The high rate of in-stent stenoses might be explained by the rigid follow-up protocol including angiography, trans-stenotic pressure measurements, and the high number of 5-mm vessels in our study.

Adult↗

[CT-guided thoracal sympathicolysis for the treatment of peripheral arterial occlusive disease and chronic thoracal pain syndromes in 6 patients].

UNLABELLED: CT-guided thoracal sympathicolysis for the treatment of peripheral arterial occlusive disease and chronic thoracal pain syndromes in 6 patients. PURPOSE: Retrospective evaluation of the safety and effectivity of CT-guided percutaneous thoracal sympathicolysis (CT-TSL) in the treatment of patients with peripheral arterial occlusive disease (PAOD) of the upper limb and chronic thoracal pain syndromes. Comparison of our own experience with literature reports. MATERIAL AND METHODS: Between 6/96 and 12/99, 4 patients with PAOD of the upper limb and two with chronic thoracal pain syndromes caused by herpes zoster were treated by unilateral CT-TSL. RESULTS: 18, 21 and 32 months after the intervention 3 out of 4 patients treated for PAOD reported subjective improvements, and one remained unchanged. Two patients treated for pain syndromes showed no long-term benefit of the procedure. There were no serious complications. CONCLUSION: The CT-TSL is an alternative method in the treatment of PAOD in patients who are unsuitable for treatment by revascularization.

Aged↗

[Indirect MR Arthrography of the wrist in the diagnosis of TFCC-Lesions].

PURPOSE: The objective of this prospective study was to assess the value of the indirect MR arthrography (MR-AR) of the wrist in the detection of lesions of the TFCC. MATERIAL AND METHODS: Indirect MR-AR was performed in 45 patients (23 f/22 m) with unclear ulnar wrist pain. After i. v. injection of 0.1 mmol/kg Gd-DTPA and after a motion-phase of the wrist (15 minutes) MRI was performed in a coronal plane. We used a STIR-, a fatsaturated (fs) T1-SE and a 3D-DESS sequence. The images were evaluated by two radiologists using a consensus score. The lesions were assigned to the system of Palmer and correlated with arthroscopy. RESULTS: Indirect MR-AR showed in 35 of 45 patients a lesion of the TFCC, but arthroscopy only revealed a defect in 32 cases. This means three false positive but no false negative assessments by MRI. Using this MRI protocol sensitivity and specificity in the detection of TFCC lesions were calculated as 100 % and 77 %. The accuracy was 93 %. Small degenerative changes of the fibres were most common (Palmer type II A). In trauma patients the ligaments usually showed tears near the insertion at the ulna (Palmer type I B). The sensitivity and specificity was 88 % and 95 % for evaluation of the scapho-lunate (SL) ligament, the accuracy was 93 %. Arthroscopy and MRI did not diagnose any rupture of the lunate-triquetral (LT) ligament. CONCLUSION: Indirect MR-AR is a non-invasive method with a high sensitivity in the evaluation of the TFCC and associated injuries. Therefore, it is an excellent screening procedure to assess the indication for therapeutic arthroscopy.

Adolescent↗

Quantification of blood flow in the carotid arteries: comparison of Doppler ultrasound and three different phase-contrast magnetic resonance imaging sequences.

RATIONALE AND OBJECTIVES: To compare blood flow velocities in the carotid arteries measured with three different magnetic resonance (MR) phase-contrast imaging techniques and with percutaneous Doppler ultrasound. METHODS: Fourteen healthy male volunteers with a mean age of 33 +/- 3.8 years were studied. Ultrasound and MR phase velocity mapping of both common carotid arteries (n = 28) was performed within 5 hours. A two-dimensional fast low-angle shot sequence with retrospective cardiac gating, a sequence with prospective cardiac triggering, and a breath-hold sequence with prospective cardiac triggering were used. Resistance indexes and pulsatility indexes were calculated for all modalities. RESULTS: The comparison of flow velocities obtained with ultrasound and the different MR techniques led to a moderate correlation of the retrospective gated and prospective triggered MR techniques (eg, r = 0.73 for maximum systolic velocity). The worst correlation was found between the breath-hold technique and retrospective cardiac gating (eg, r = 0.004 for pulsatility index). There was a weak correlation of all three MR sequences compared with ultrasound (r = 0.19-0.60) CONCLUSIONS: A moderate correlation was found between velocities and indexes measured with the prospective cardiac-triggered phase-contrast MR technique and the retrospective cardiac-gated phase-contrast MR technique. A weak correlation was found between the three different MR techniques and ultrasound, as well as between the breath-hold prospective cardiac-triggered MR sequence and both of the other MR sequences. The influence of temporal and spatial resolution on MR phase-contrast velocity mapping was confirmed.

Adult↗

Appearance of vascular stents in computed tomographic angiography: in vitro examination of 14 different stent types.

RATIONALE AND OBJECTIVES: To evaluate the appearance of the vessel lumen after implantation of different vascular stents with the use of a computed tomographic (CT) angiography model. METHODS: A vascular phantom was studied with helical CT and different slice thicknesses (2 and 3 mm) and pitch values (1.0, 1.5, and 2.0). Original transverse CT images and coronal reformations were evaluated. Fourteen different stents were analyzed with regard to changes in the stent lumen (attenuation values, noise, and artificial lumen narrowing). RESULTS: Some stents caused artifacts resulting in potential errors during evaluation of their patency. Assessment of the lumen was impaired in two stents (Strecker tantalum and Passager). Increased attenuation values were measured in all stents (increase of 8%-145%). The degree of artificial lumen narrowing was 4.4% to 77.8%. CONCLUSIONS: In most stents, reliable evaluation of the stent lumen seems possible. However, knowledge of the artifacts caused by different stent types is useful for the assessment of stent patency with CT angiography.

Angiography↗

Comparison between magnetic resonance phase contrast imaging and transcranial Doppler ultrasound with regard to blood flow velocity in intracranial arteries: work in progress.

OBJECTIVE: The authors evaluate blood flow velocities in the medial cerebral artery (MCA) and the basilar artery using magnetic resonance (MR) phase contrast technique in comparison with transcranial Doppler ultrasound (TCD). Eleven healthy male volunteers were studied. TCD of the MCA (n = 22) and basilar artery (n = 11) was performed. MR phase velocity mapping was done in each vessel at the same location where the TCD signal had been acquired. A 2-dimensional FLASH sequence with retrospective cardiac gating and an average temporal resolution of 45 ms was used. Resistance indices (RIs) and pulsatility indices (PIs) were calculated for both modalities. The TCD insonation angle was measured retrospectively with MR, and TCD velocities were corrected based on these measurements. The comparison of flow velocities obtained with TCD and MR led to a low correlation coefficient with regard to the basilar artery and the MCA: maximum systolic velocity, r = 0.02 and r = 0.50, respectively; enddiastolic velocity, r = 0.47 and r = 0.65, respectively; mean velocity, r = 0.52 and r = 0.66, respectively. The average PIs in the basilar artery and the MCA were 0.80 and 0.81 with MR and 0.65 and 0.85 with TCD, respectively. The average RIs in the basilar artery and the MCA were 0.52 and 0.54 with MR and 0.52 and 0.55 with TCD, respectively. The TCD insonation angle differed significantly from the ideal value in the basilar artery (mean value = 32.6 degrees) and the MCA (mean value = 26.5 degrees). The authors find a low correlation between velocities measured with MRI and TCD but similar results with regard to the PIs and RIs. Several sources of error, such as a nonideal TCD insonation angle, were identified.

Adult↗