Visualization of the IXth to XIIth cranial nerves using 3-dimensional constructive interference in steady state, 3-dimensional magnetization-prepared rapid gradient echo and T2-weighted 2-dimensional turbo spin echo magnetic resonance imaging sequences.

OBJECTIVE: The purpose of this study was to evaluate the visibility of the IXth to XIIth cranial nerves using different magnetic resonance sequences. Thirty healthy volunteers underwent magnetic resonance imaging at 1.5 T using 3-dimensional constructive interference in steady state (CISS) sequence (TR = 17 ms, TE = 8.08 ms, alpha = 70 degrees), 3-dimensional magnetization-prepared rapid gradient echo (MP-RAGE) sequence (TR = 11.08 ms, TE = 4.3 ms, alpha = 15 degrees), and T2-weighted (w) 2-dimensional turbo spin echo (TSE) sequence (TR = 4000 ms, TE = 102 ms, alpha = 180 degrees, slice thickness = 2 mm). Visibility of the IXth to XIIth cranial nerves in each sequence was evaluated by consensus of 2 radiologists using an evaluation scale from 1 (excellently visible) to 5 (not visible). A correlation with anatomic specimens was made. The 3-dimensional CISS sequence provides best resolution of the IXth to XIIth cranial nerves and their relation to surrounding structures. Additional information is given by the 3-dimensional MP-RAGE when nerves are surrounded by soft tissues. Using the T2w 2-dimensional TSE sequence, even whole nerves cannot be visualized due to intersection gap and partial volume effects. However, even in 3-dimensional high-resolution sequences, segments of nerves are not always visualized. A combination of 3-dimensional CISS and 3-dimensional MP-RAGE proved to be useful to visualize the IXth to XIIth cranial nerves, whereas the 2-dimensional technique failed. Further investigations using 3-dimensional MP-RAGE with contrast medium should be performed in the case of abnormality.

Accessory Nerve↗

MR imaging-guided stent placement in iliac arterial stenoses: a feasibility study.

PURPOSE: To assess the feasibility of magnetic resonance (MR) imaging-guided stent placement in iliac arterial stenoses. MATERIALS AND METHODS: Thirteen patients with 14 iliac arterial stenoses were examined prospectively. Angioplasty was performed through a femoral sheath by using a conventional 1.5-T MR imaging system. Stents and catheters were visualized on the basis of their artifacts. Nitinol stents were placed with gradient-echo MR imaging guidance. Angioplasty balloons were inflated with gadolinium-based contrast material. Results were evaluated clinically and with both digital subtraction angiography (DSA) and contrast material-enhanced MR angiography. RESULTS: Ten of 13 patients were treated with technical success by using MR imaging-guided intervention alone. Three patients were treated with additional fluoroscopic guidance, because complications (ie, panic attack, subintimal recanalization, and stent misplacement) occurred with MR guidance. The quality of the postinterventional contrast-enhanced MR angiograms of three of 12 lesions with stents was limited owing to stent-induced signal loss of the lumen. The mean stenosis degree after stent placement was significantly higher at contrast-enhanced MR angiography than at DSA (24.6% vs 6.2%). The mean MR imaging-guided procedure time was 74 minutes. CONCLUSION: MR imaging-guided stent placement in iliac arteries is feasible in select patients. The presented technique has limitations-that is, long procedure times, lack of real-time monitoring, and stent artifacts-that necessitate further modifications before it can be recommended for clinical use.

Aged↗

Renal time-resolved MR angiography: quantitative comparison of gadobenate dimeglumine and gadopentetate dimeglumine with different doses.

PURPOSE: Results with different doses of gadobenate dimeglumine and gadopentetate dimeglumine were compared at magnetic resonance (MR) angiography of the renal arteries. The signal-to-noise ratio (SNR) was evaluated as a quantitative measure of image quality. MATERIALS AND METHODS: Sixty consecutive patients (age range, 24-81 years; mean age, 65 years) underwent intraarterial digital subtraction angiography (DSA) and contrast material-enhanced time-resolved MR angiography. DSA was the standard of reference. Fifteen patients received gadopentetate dimeglumine at doses of 0.2 or 0.1 mmol per kilogram of body weight. Fifteen patients received gadobenate dimeglumine at doses of 0.05 or 0.1 mmol/kg. The SNR was calculated in the aorta and both main renal arteries. The number and degree of stenoses of the renal arteries and accessory vessels were evaluated by four observers. RESULTS: SNRs with gadobenate dimeglumine at a dose of 0.1 mmol/kg were significantly superior to those with gadopentetate dimeglumine at a dose of 0.1 mmol/kg. Differences were not statistically significant between the SNRs in the other groups. Eleven (85%) of 13 hemodynamically significant renal artery stenoses were detected correctly with MR angiography as were 22 (85%) of 26 accessory renal arteries. CONCLUSION: SNRs with gadobenate dimeglumine were higher than those with gadopentetate dimeglumine, but in most cases the differences in SNRs were not statistically significant.

Adult↗

Spinal metastases from renal cell carcinoma: effect of preoperative particle embolization on intraoperative blood loss.

BACKGROUND AND PURPOSE: Surgical repair of spinal metastases from renal origin is often complicated by excessive bleeding. The purpose of this study was to assess the effect of preoperative particulate embolization on intraoperative blood loss. METHODS: Twenty spinal metastases from renal origin (17 patients) treated by preoperative embolization with polyvinyl alcohol particles were analyzed retrospectively. Surgical decompression was performed within 2 days after embolization. A control group of 10 patients with 11 spinal metastases of renal origin underwent surgery without embolization. The effect of preoperative embolization, of completeness of embolization, and of particle size on the estimated intraoperative blood loss was analyzed using nonparametric statistical tests. RESULTS: Complete embolization was achieved in 10 cases and partial embolization in the other 10. The estimated blood loss of 19 embolized and 11 control cases was available from the surgical report. Median intraoperative blood loss in 19 embolized lesions was 1500 mL (range, 300-8000 mL), compared with 5000 mL (range, 1440-15000 mL) in the control group. Even after partial embolization, blood loss (median, 2000 mL) was significantly lower than in the control group. No significant differences in estimated blood loss were noted between the use of particles smaller than 250 microm and those larger than 250 microm. No embolization-related permanent neurologic deficit or skin or muscle necrosis occurred. CONCLUSION: Preoperative embolization of spinal metastases of renal origin with polyvinyl alcohol particles is safe and might reduce intraoperative blood loss significantly. Even partial embolization seems to be effective.

Aged↗

Value of high-resolution MR in patients scheduled for cochlear implantation.

OBJECTIVE: To determine sensitivity and specificity of high-resolution MR imaging and of high-resolution axial CT (HRCT) and to compare the two modalities in predicting the surgical and functional success of cochlear implantation. MATERIAL AND METHODS: The presurgical MR images (2D T2W TSE, 3D T2*W CISS, plain and contrast-enhanced 3D T1W MP-RAGE) and axial HRCT findings of 26 patients were evaluated with regard to the predictive value concerning the success of cochlear implantation. RESULTS: We found a high correlation between MR and HRCT and the success of cochlear implantation. In all 26 patients, the MR-based predictions concerning the success of cochlear implantation were correct. In 10 patients, MR gave additional information to HRCT. In all patients, MR gave sufficient information about the status of the inner ear, inner auditory canal and cochlear nerve to aid the surgeon during the operation. CONCLUSION: A high-resolution MR protocol consisting of coronal 2D T2W TSE, 3D T2*W axial CISS, plain and contrast-enhanced sagittal T1W 3D MP-RAGE is recommended for the evaluation of candidates scheduled for cochlear implantation. It provides information which cannot be obtained by HRCT.

Adolescent↗

[Carotid endarterectomy and carotid stenting. A pilot study of a prospective, randomized and controlled comparison].

INTRODUCTION: A prospective, randomized and controlled trial is conducted to compare carotid endarterectomy and carotid stenting in high grade symptomatic carotid artery stenoses. METHODS: According to the study design symptomatic patients with a angiographically high-grade (> or = 70%) internal carotid artery stenosis are included. Pre- and postinterventional diagnostics during the hospitalization period includes neurological assessment, duplex sonography of the cervical and cerebral arteries and magnetic resonance imaging of the brain. Follow-up examinations are scheduled after 1, 6 and 12 months and consist of a neurological assessment and duplex sonography. After 12 months selective angiography and magnetic resonance imaging of the brain will be performed additionally. During a period of 9 months up to now 23/137 patients treated for a carotid artery stenosis were included in the study, 11 patients underwent surgery and 12 patients carotid stenting. RESULTS: Carotid stenting and endarterectomy was primarily successful without residual stenosis > 30% in each patient without the occurrence of stroke or death. In 18 follow-up examinations (neurological assessment including duplex sonography) of 13 patients (13 follow-up examinations after 30 days, 5 after 6 months) no relevant restenosis and no stroke occurred. CONCLUSION: As of yet, carotid stenting was a safe procedure. Due to the small number of patients a definitive conclusion can not be drawn.

Angiography, Digital Subtraction↗

Digital radiography of the skeleton using a large-area detector based on amorphous silicon technology: image quality and potential for dose reduction in comparison with screen-film radiography.

AIM: The purpose of this study was to evaluate a large-area, flat-panel X-ray detector (FD), based on caesium-iodide (CsI) and amorphous silicon (a-Si) with respect to skeletal radiography. Conventional images were compared with digital radiographs using identical and reduced radiation doses. MATERIALS AND METHODS: Thirty consecutive patients were studied prospectively using conventional screen-film radiography (SFR; detector dose 2.5 microGy). Digital images were taken from the same patients with detector doses of 2.5, 1.25 and 0.625 microGy, respectively. The active-matrix detector had a panel size of 43 x 43 cm, a matrix of 3 x 3K, and a pixel size of 143 microm. All hard copies were presented in a random order to eight independent observers, who rated image quality according to subjective quality criteria. Results were assessed for significance using the Student's t -test (confidence level 95%). RESULTS: A statistically significant preference for digital over conventional images was revealed for all quality criteria, except for over-exposure (detector dose 2.5 microGy). Digital images with a 50% dose showed a small, statistically not significant, inferiority compared with SFR. The FD-technique was significantly inferior to SFR at 75% dose reduction regarding bone cortex and trabecula, contrast and overall impression. No statistically significant differences were found with regard to over- and under-exposure and soft tissue presentation. CONCLUSION: Amorphous silicon-based digital radiography yields good image quality. The potential for dose reduction depends on the clinical query.

Aged↗

[The ultrasound centre as a medically and economically relevant alternative--a report of the Regensburg experience].

In most medical centres, ultrasonography is performed independently by several departments. In october 1997, the University hospital of Regensburg founded an ultrasound centre, integrating surgical and medical departments as well as the institutes for radiology and nuclear medicine. The aims of this centre were the concentration of organization, machines, financial resources, manpower and know-how, standardized training and quality, and strengthening of interdisciplinary cooperation in clinic, medical education and research. Booking, standardized reports and a joint archiving of reports are assisted by a collective computer system. Most examinations in the centre are performed by three all-day present gastroenterology, surgery and radiology residents who are supported by licensed sonographers of the other departments. Training is standardized, and the certification for ultrasound examinations is acquired after a test with theoretical and practical parts. The integration of various departments in the ultra-sound on-call service has led to significant savings. The pool of ultrasound machines is used jointly, department-specific resources for new machines have been put together. We are convinced that this way of a close interdisciplinary cooperation will result in improvements in quality, utilization of financial resources and clinical research.

Cost-Benefit Analysis↗

[Stent angioplasty of pelvic artery stenosis with MRI control: initial clinical results].

PURPOSE: To investigate the feasibility of MR-guided stent angioplasty of iliac artery stenoses under passive visualization. MATERIAL AND METHODS: Three patients with short, concentric stenoses of the iliac arteries were enrolled. The vascular interventions were performed on a 1.5 T MR scanner (Magnetom Symphony, Siemens, Erlangen, Germany). Stents, guidewires, and balloon catheters were visualized on the basis of susceptibility artifacts. Contrast-enhanced MR angiography (ceMRA) was used to localized the stenosis prior to stent deployment. Nitinol stents were placed under MR-guidance using a fast 2D gradient echo technique. Balloon dilatiation was performed with an angioplasty catheter inflated with diluted gadolinium-DTPA. Postinterventional results were evaluated by ceMRA, DSA, and Doppler indices. RESULTS: Position of the stent, stent deployment, and balloon dilatation were depicted by MR. All stents were correctly placed within the stenosis. Stent positions as monitored by MRI were identical to those seen on DSA images. All patients were treated successfully by the MR-guided intervention. CONCLUSION: An MR-guided stent angioplasty of simple iliac artery stenosis is feasible under passive visualization.

Aged↗

[CT-guided biopsies, drainage and and percutaneous gastrostomies: comparison of punctures with and without CT fluoroscopy].

PURPOSE: The purpose of this prospective and randomized study was to compare two CT guidance techniques (CT-fluoroscopy/conventional CT) on percutaneous biopsies, drainages and gastrostomies. MATERIAL AND METHODS: 78 CT-guided interventions (29 biopsies, 38 drainages, 8 gastrostomies) were recorded and the Mann-Whitney U-test was applied. In 3 cases both guidance techniques were used. Procedure times, yields and radiation doses were analyzed. RESULTS: All 38 drainages and all 8 gastrostomies were successfully applied. 13 biopsies with conventional CT guidance (n = 15) and 13 biopsies with CT-fluoroscopy (n = 14) showed a representative histopathologic result. The procedure times were not significantly different (drainages: p = 0.658, biopsies: p = 0.431, gastrostomies: p > 0.06). The radiation doses (CTID1) of the biopsies and drainages showed significantly higher values (drainages p < 0.001, biopsies p < 0.001) with CT-fluoroscopy than with conventional CT. There were no significant differences in gastrostomy procedures (p > 0.06). CONCLUSION: Procedure times and yields were not improved by using CT-fluoroscopy. Radiation doses showed significantly higher values with CT-fluoroscopy than with conventional CT guidance. CT-fluoroscopy was advantageous in non-compliant patients over conventional CT guidance.

Adult↗

[Volume-artifact reduction technique by spiral CT in the anterior, middle and posterior cranial fossae. Comparison with conventional cranial CT].

PURPOSE: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). METHODS: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. RESULTS: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosal bone, at the internal occipital crest, and at the level of the transverse sinus (p < 0.005). CONCLUSIONS: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae.

Adolescent↗

[Therapy of iliac artery lesions with a new premounted balloon-expandable stent ("Flexible Iliac Bridge Stent")].

PURPOSE: Evaluation of the handling, technical success rate and six month patency rate of a new, premounted balloon-expandable stent in iliac artery lesions. MATERIALS AND METHODS: In a prospective study 26 stenoses and 3 occlusions of the iliac arteries were primary treated in 24 patients (Fontaine IIa-III, mean age 60.4 year) with the "Flexible Iliac Bridge Stent" (Medtronic AVE, Düsseldorf). Five patients had bilateral stenoses. The ankle-brachial index (ABI) in rest and after exercise was determined before the intervention as well as 1-3 days, 1 and 6 months after the Intervention. The handling and visibility of the stent was scored on a three grade scale by the operators. Follow-up angiography including intraarterial pressure measurement was performed in 17 out of 24 patients (21 out of 29 lesions) after 6 months. RESULTS: All 29 lesions were treated with technical success by implantation of 36 stents. The mean degree of the stenoses before intervention was 72.7 +/- 13.8% (+/- 1 standard deviation) and less than 5% in all cases postinterventionally. The mean pressure gradient before and after stent placement was 21 +/- 13.1 mm Hg and 0.8 +/- 2.3 mm Hg, respectively. The Fontaine stage improved by at least one in all patients. The mean ABI at rest improved from 0.63 +/- 0.15 to 0.89 +/- 0.16, and after exercise from 0.46 +/- 0.17 to 0.8 +/- 0.2, respectively. At 6 months 2 lesions out of 21 (9.5%) showed a restenosis of 55% and 70% with an intraarterial pressure gradient of 16 mm Hg and 27 mm Hg, respectively. After 6 months the mean ABI at rest decreased to 0.83 +/- 0.13, and to 0.72 +/- 0.14 after exercise. Handling and visibility was scored as good by all operators. CONCLUSION: Endoluminal therapy of iliac artery lesions with the used stent is safe and effective. The six month patency rate is comparable to the published data of other stents.

Adult↗

[Contrast media-enhanced MR angiography of the lower extremity arteries using a dedicated peripheral vascular coil system. First clinical results].

PURPOSE: To evaluate contrast enhanced magnetic resonance angiography (ceMRA) of the pelvic and peripheral arteries with a dedicated peripheral vascular coil system and automated table-feed technique in patients with arterial occlusive disease. METHODS: Three-dimensional gadolinium-enhanced MR angiography in a two-step automatic table feed technique was performed in 45 patients using a 1.5 Tesla imager (Magnetom Symphony, Siemens). The pelvic arteries were imaged with a single injection of contrast material. The upper and the lower leg were imaged with a second injection of contrast material in an automated table feed technique using a dedicated vascular coil system. In 20 patients ceMRA was compared with digital subtraction angiography (DSA) as the standard of reference and in 25 patients ceMRA was performed solely. RESULTS: Sensitivity and specificity for grading significant stenoses > or = 50% and occlusions (in parenthesis) were in the pelvic arteries 94.7%, 96.8%, (100%, 100%), in the arteries of the upper leg 92.3%, 93.3% (87.5%, 100%) and in the arteries of the lower leg 96.5%, 95.8%, (95.2%, 96.8%), respectively. Depiction of the runoff vessels of the lower leg was excellent in ceMRA. CeMRA was of diagnostic quality in all the patients. CONCLUSION: Contrast-enhanced MRA using a dedicated peripheral vascular coil system increases the diagnostic quality of the lower leg. The runoff vessels can be evaluated. Thus, ceMRA in the presented technique is a diagnostic alternative to arterial angiography.

Adult↗

Morphology and hemodynamics in dissection of the descending aorta. Assessment with MR imaging.

PURPOSE: To obtain morphologic and functional information in patients with dissection of the descending aorta using contrast-enhanced MR angiography (MRA) and MR blood flow quantification of the true and false lumina. MATERIAL AND METHODS: Fourteen patients were studied prospectively using a 1.5 T unit. MRA was performed with a 3D FISP sequence (TR/TE/flip angle 4.7/1.9 ms/30 degrees) after injection of 0.2 mmol Gd-DTPA per kg b.w. Flow quantification with phase velocity mapping was done at the level of the diaphragm using a 2D FLASH technique (TR/TE/flip angle 28/6.5 ms/30 degrees) with an average temporal resolution of 23 frames per cardiac cycle (34 ms). A spectral broadening index was applied to quantify the amount of flow irregularity within both channels of the aorta. Extension of the dissection and involvement of the major branch vessels were analyzed. RESULTS: The mean flow volume per minute was 1,982 ml (SD 1,083 ml) in the true and 1,052 ml (SD 763 ml) in the false lumen. Average peak-velocities were 98 cm/s (SD 33 cm/s) in the true channel and 47 cm/s (SD 26 cm/s) in the false channel. Ten patients had bidirectional flow in the false lumen with a reflux volume ranging between 6.8% and 98%. Only 1 patient presented with bidirectional flow in the true lumen (reflux volume 15%). A significantly higher degree of flow irregularity was found in the false lumen compared with the true channel. CONCLUSION: Different hemodynamic patterns were found in aortic dissection. Their prognostic value and the impact on therapy, specifically percutaneous interventional procedures, have to be further studied.

Adult↗