PubMed HealthSearch

Biomedical subjects

S G Proskurin

Publications and source records attributed to S G Proskurin.

3 recordsLinked to original sources

Application of the zooming method in near-infrared imaging.

Images of a tissue simulating phantom are obtained by inverting a limited number of continuous-wave relative transmission measurements. The diffusion approximation to the radiative transfer equation is used as a light propagation model. The inversion procedure is based on a quasi-Newton method and the Levenberg-Marquardt method, and the imaging parameter is the absorption coefficient of the phantom. It is shown that the resolution of the images can be improved using the zooming method. The image indicates the presence of an inhomogeneity in approximately the correct location, but the shape and size of the inhomogeneity in the reconstructed image differs from the shape and size of the actual inhomogeneity. Possible methods for further enhancement of the images are discussed.

Algorithms

A new method of bone tissue measurement based upon light scattering.

In recent years, time-resolved spectroscopy systems using near infrared pulsed laser have been applied to develop optical computed tomography. We applied this technique to measure the optical properties of osseous tissues. First, we gradually demineralized 10 mm blocks of bovine trabecular bone with EDTA, maintaining the absorption characteristics and structure but varying the hydroxyapatite content, thus creating specimens differing only in light scattering properties. We used computer densitograms to assess light penetration, and analyzed the correlation with bone mineral density (BMD) as with dual-energy X-ray absorptiometry scans. The light penetration increased with decreasing BMD. Second, using the above-mentioned pulsed laser time-resolved spectroscopy system, we investigated the correlation between the BMD and the time response waveforms of 10-mm blocks of bovine cortical bone, trabecular bone, and surrounding tissue as well as human trabecular bone. The human lumbar vertebral bone also displayed an inverse correlation between BMD and maximum light penetration and a positive correlation between BMD and peak time delay. This is the first demonstration of a correlation between BMD and light scattering properties showing that BMD can indeed be measured with light. Our results show the possibility of obtaining information on internal bone structure and composition in vivo through assessment of the waveforms obtained by a time-resolution system in the near infrared region.

Animals

[A decrease in the hydrodynamic resistance in the mesenteric arterioles of rats injected with the polyethylene oxide Polyox WSR-301].

The infusion of polyethylene oxide in anesthetised rats in a total dose of 10(-7) g/ml caused a 10-16% reduction in blood pressure. This injection has been associated with 17% decreased pressure (servo-nulling method) and 54% increased blood velocity (laser Doppler fluxmetry) in mesenteric arterioles (d - about 24 mu), but no increase in their internal diameter was observed (image-split method). Vasodilatation (adenosine, 10(-5) M) did not change the hemodynamic response of the arterioles to polymer infusion. These results suggest that microdisturbances of blood flow which can be diminished by drug-reducing polymers are more important for the vascular resistance to blood than it has been previously.

Animals