PubMed Health⌕ Search

Biomedical subjects

S G Weber

Publications and source records attributed to S G Weber.

At least 19 recordsLinked to original sources

Electroporation of single cells and tissues with an electrolyte-filled capillary.

We show how an electrolyte-filled capillary (EFC) coupled to a high-voltage power supply can be used as a versatile electroporation tool for the delivery of dyes, drugs, and biomolecules to the cytoplasm of single cells and cells in tissues. A large-voltage pulse applied across the EFC (fused silica, 30 cm long, 375-microm o.d., 30-microm i.d.) gives rise to a small electric field outside the terminus of the EFC, which causes pore formation in cell membranes and induces an electroosmotic flow of electrolyte. When the EFC contains cell-loading agents, then the electroosmotic flow delivers the agents at the site of pore formation. The combination of pore formation and delivery enables loading of materials into the cytoplasm. By patch-clamp and fluorescence microscopy, formation of pores was observed at estimated transmembrane voltages of <85 mV with half-maximum values around 206 mV. The electroporation protocol was demonstrated by introduction of fluorogenic dyes into single NG108-15 cells, cellular processes, and small populations of cells in organotypic hippocampal cultures. Preliminary results are shown in which this protocol was employed for in vivo electroporation of ventral mesencephalon in rat brains. The technique was also used to access organelle-based detection systems inside cells. As a demonstration, 1,4,5-inositoltriphosphate was added to the electrolyte and detected by intracellular organelles in electroporated cells.

Animals↗

Alterations in glutathione and amino acid concentrations after hypoxia-ischemia in the immature rat brain.

Hypoxic-ischemic brain injury involves an increased formation of reactive oxygen species. Key factors in the cellular protection against such agents are the GSH-associated reactions. In the present study we examined alterations in total glutathione and GSSG concentrations in mitochondria-enriched fractions and tissue homogenates from the cerebral cortex of 7-day-old rats at 0, 1, 3, 8, 14, 24 and 72 h after hypoxia-ischemia. The concentration of total glutathione was transiently decreased immediately after hypoxia-ischemia in the mitochondrial fraction, but not in the tissue, recovered, and then decreased both in mitochondrial fraction and homogenate after 14 h, reaching a minimum at 24 h after hypoxia-ischemia. The level of GSSG was approximately 4% of total glutathione and increased selectively in the mitochondrial fraction immediately after hypoxia-ischemia. The decrease in glutathione may be important in the development of cell death via impaired free radical inactivation and/or redox related changes. The effects of hypoxia-ischemia on the concentrations of selected amino acids varied. The levels of phosphoethanolamine, an amine previously reported to be released in ischemia, mirrored the changes in glutathione. GABA concentrations initially increased (0-3 h) followed by a decrease at 72 h. Glutamine levels increased, whereas glutamate and aspartate were unchanged up to 24 h after the insult. The results on total glutathione and GSSG are discussed in relation to changes in mitochondrial respiration and microtubule associated protein-2 (MAP2) which are reported on in accompanying paper [64].

Age Factors↗

Chromatographic detection of nitroaromatic and nitramine compounds by electrochemical reduction combined with photoluminescence following electron transfer.

The oxidizing agent tris(bipyridyl)ruthenium(III), or Ru-(bpy)(3)3+, is used as a postcolumn reagent for the detection of nitroaromatic and nitramine explosive compounds. After separation, the explosives are reduced electrochemically to oxidizable products such as hydroxlamines and nitrosamines, and these products react readily with Ru-(bpy)(3)3+ and Ru(bpy)(3)2+. The photoluminescence from the latter is used for detection. A porous carbon electrode was used for on-line analyte reduction following chromatography. Another porous carbon electrode was used to generate the nonluminescent Ru(bpy)(3)3+ from Ru(bpy)(3)3+ on-line at high efficiency. The two streams were combined, and the Ru(bpy)(3)2+ produced by oxidation of the reduced analytes was detected by laser illumination and light detection. Reductive hydrodynamic voltammograms of nitrobenzene, 2,4,6-trinitrotoluene, and hexahydro-1,3,5-trinitro-1,3,5-triazine indicated that a potential of - 1500 mV vs Ag/AgCl was sufficient to achieve a maximum signal from the reduced analytes. HPLC with a water/acetonitrile gradient on a C-18 reversed-phase column was then used to determine these three compounds plus the four additional examples, 1,3,5,7-tetrazocine, 2,4-dinitrotoluene; 2,6-dinitrotoluene, and 4-nitrotoluene. For both hydrodynamic voltammetry and HPLC detection, the photoluminescence following electron-transfer signal was calibrated using the one-electron standards ferrocene and ferrocenecarboxylic acid. Detection limits were in the low-nanomolar range for 20-microL injections of nonpreconcentrated nitro compounds.

Aniline Compounds↗

Characterization of single-cell electroporation by using patch-clamp and fluorescence microscopy.

Electroporation of single NG108-15 cells with carbon-fiber microelectrodes was characterized by patch-clamp recordings and fluorescence microscopy. To minimize adverse capacitive charging effects, the patch-clamp pipette was sealed on the cell at a 90(o) angle with respect to the microelectrodes where the applied potential reaches a minimum. From transmembrane current responses, we determined the electric field strengths necessary for ion-permeable pore formation and investigated the kinetics of pore opening and closing as well as pore open times. From both patch-clamp and fluorescence microscopy experiments, the threshold transmembrane potentials for dielectric breakdown of NG108-15 cells, using 1-ms rectangular waveform pulses, was approximately 250 mV. The electroporation pulse preceded pore formation, and analyte entry into the cells was dictated by concentration, and membrane resting potential driving forces. By stepwise moving a cell out of the focused field while measuring the transmembrane current response during a supramaximal pulse, we show that cells at a distance of approximately 30 microm from the focused field were not permeabilized.

Animals↗

Chromatographic detection using tris(2,2'-bipyridyl)ruthenium(III) as a fluorogenic electron-transfer reagent.

Tris(2,2'-bipyridyl)ruthenium can be excited to fluorescence by visible light (lambda abs 454 nm, lambda em 607 nm) when in the M(II) oxidation state, but not in the M(III) state. A novel chromatographic detection method using the non-fluorescent M(III) form of the complex as a postcolumn fluorogenic reagent is demonstrated. The M(III) form is a powerful oxidizing agent (E degree = 1.27 V vs NHE, 1.05 V vs Ag/AgCl). The M(III) reagent is generated on-line from the M(II) form of the complex by a highly efficient porous carbon electrode and then reacted briefly with chromatographic effluent; the M(II) created by electron transfer from oxidation-susceptible analytes is then detected by fluorescence. The fluorescence detector can be calibrated for number of electrons transferred by injection of either M(II) or an oxidative standard such as ferrocyanide. It is hoped that this redox-based detection scheme will provide an alternative to electrochemical detection. Among the advantages are freedom from surface fouling and the potential for extremely low detection limits. The scheme was applied to detection of the peptide dynorphin A and several of its fragments. Dynorphin A contains tyrosine at the N-terminus (position 1) and tryptophan in position 15; these amino acid residues are susceptible to oxidation and peptides containing them can be detected on that basis. Flow injection testing of the model compounds Tyr-Gly-Gly-Phe-Leu and Gly-Gly-Trp-Gly indicated that tyrosine transferred approximately 1 electron to the M(III) reagent and that tryptophan transferred approximately 4 electrons. Similar results were obtained from the chromatographic runs. Dynorphin A and six dynorphin A fragments containing the N-terminal tyrosine were detected easily at 100 nM concentration (14 pmol) using laser-induced fluorescence. As expected, one fragment that did not contain tryptophan or tyrosine was not detected. A mass detection limit of 80 fmol was estimated for the tyrosine-containing fragments.

2,2'-Dipyridyl↗

Net efflux of cysteine, glutathione and related metabolites from rat hippocampal slices during oxygen/glucose deprivation: dependence on gamma-glutamyl transpeptidase.

Extracellular metabolism of the protective substance glutathione (gamma-glutamyl-cysteinyl-glycine) may generate cysteine, glycine, several gamma-glutamyl-containing dipeptides and possibly free glutamate, all of which could participate in neurotoxicity. In the present study, we have examined how blockage of gamma-glutamyl transpeptidase, the key enzyme in glutathione degradation, influences the extracellular concentrations of glutathione, cysteine and related metabolites during anoxia/aglycemia of rat hippocampal slices. The net efflux, i.e., the increase in extracellular concentration due to changes in release and/or uptake, of cysteine, cysteine sulfinate, gamma-glutamyl-glutamate, gamma-glutamyl-glutamine, glutathione, gamma-glutamyl-cysteine and glutamate increased as a result of anoxia/aglycemia. These increases in net efflux of cysteine, cysteine sulfinate, gamma-glutamyl-glutamate and gamma-glutamyl-glutamine were reduced or blocked by acivicin, an inhibitor of gamma-glutamyl transpeptidase. In contrast, acivicin caused an increase in both basal and anoxia/aglycemia-induced net efflux of glutathione whereas the basal and anoxia/aglycemia-induced efflux of glutamate was unchanged by acivicin treatment. The effect of acivicin on the efflux of gamma-glutamyl-cysteine was similar to that of glutathione although less pronounced. Addition of beta-mercaptoethanol to the incubation medium during and after 30 min of anoxia/aglycemia decreased the net efflux of cysteine sulfinate specifically, indicating that the increase in cysteine sulfinate during anoxia/aglycemia may be partly derived from the spontaneous oxidation of cysteine. The results suggest that gamma-glutamyl transpeptidase may be involved in the regulation of the extracellular concentrations of cysteine, several gamma-glutamyl-containing dipeptides and glutathione but not glutamate during ischemia.

Animals↗

Development of a liquid chromatographic method for picomole determination of S-sulfocysteine in trifluoroacetic acid extracts of neonatal rat brain.

Neonatal Sprague Dawley rat brain tissue was extracted with methanol, acetonitrile, acetic acid and trifluoroacetic acids (TFA). Among the extractants tested, 0.1 M TFA gave the highest recovery, 73.4 +/- 5.2% (slope of regression of 'added' vs. 'found' and standard error of the slope) of S-sulfocysteine (SSC). The poorest recovery of SSC was found with acetonitrile and 90% methanol extractions (less than 10%). Possible reasons for the low recoveries have been explored. The recovery of SSC from aqueous standards in 0.1 M TFA is 92 +/- 5%. Detection of picomole quantities of SSC has been demonstrated with a combination of the optimized extraction procedures and our previously developed detection system. Supernatant of rat brain homogenate (0.10 M TFA as extractant) was evaporated to dryness in a vacuum centrifuge. Residues were reconstituted with deionized water. Samples were separated on a reversed phase column. The mobile phase was 20 mM aqueous acetate buffer (pH 5.2) containing 0.40 mM cetyl trimethylammonium p-toluene sulfonate and 2 vol.% methanol. Electrochemical detection used dual series gold-mercury amalgam electrodes. For the first time, S-sulfocysteine was detected in normal neonatal rat brain. Its concentration is 0.99 +/- 0.25 pmol/mg brain tissue. The results indicate that TFA, rarely reported an an extractant, efficiently recovers SSC from rat brain tissues.

Animals↗

Glutathione efflux induced by NMDA and kainate: implications in neurotoxicity?

Neurotoxicity in acute as well as chronic neurological diseases may be partly mediated by oxidative stress caused by overactivation of glutamate receptors. A key component of the cellular defense against oxidative stress is reduced glutathione. In our earlier work, we have shown that ischemia in brain induces increased efflux, elevated metabolism, and decreased tissue concentrations of glutathione. In this study, we have evaluated the effect of glutamate receptor activation on the efflux of glutathione from hippocampus in vitro. NMDA and kainate induced a delayed increase in glutathione, taurine, and phosphoethanolamine efflux. Extracellular glutathione was recovered mainly in the reduced form (85-95%); the efflux was dependent on extracellular calcium but unrelated to dantrolene-sensitive intracellular calcium release and independent of glutathione or NO synthesis. The NMDA-induced efflux of glutathione was enhanced by blockage of gamma-glutamyl transpeptidase, indicating an increased transpeptidation of glutathione after NMDA receptor activation. Our results suggest that increased efflux of glutathione could be a factor in initiating nerve cell death via a change in intracellular redox potential and/or a decrease in the intracellular capacity for inactivation of reactive oxygen species.

Animals↗

Comparison of anion-exchange and ion-modified reversed-phase liquid chromatography for the determination of S-sulfocysteine.

A dual Hg-Au amalgam electrode is used to detect S-sulfocysteine (SSC) in this study. There exist two main components in the acetonitrile (ACN) rat brain extracts, namely, Cl- and GSSG (oxidized glutathione), that are active in our detection system (GSH is not extracted in ACN). Two strong anion-exchange columns from different companies were used to separate the samples under different conditions, but SSC and Cl- were not separated at the optimum detection pH of 5.2. The signal from Cl- was greatly decreased by lowering the potential at the downstream electrode, though it cannot be completely eliminated. While a silver cartridge removed Cl- from micromoles to several millimoles without any negative effect on the SSC signal in aqueous standards, a large negative peak which interferes with SSC detection was unfortunately introduced when a silver cartridge was applied to brain tissue samples. However, SSC and Cl- in the samples are successfully separated by ion-modified reversed-phase LC in acetate buffer at the optimum detection pH (5.2). The separation conditions are 20 mM acetic acid, 2% methanol, 0.5 mM cetyltrimethylammonium p-toluene sulfonate (CTMA) (pH 5.2). Most importantly, the sensitivity of SSC under the optimum separation conditions is not sacrificed. The detection limit is 8 nM (20 microl injected).

Animals↗

Prediction of molecular recognition-enhanced phenobarbital extraction based on solvatochromic analysis.

The extraction efficiency for organic molecules using synthetic receptors is highly dependent on solvent properties. Solvent influences the partitioning of both the desired compound and the interfering species. Solvent also influences the solubility of the receptor and its affinity for the substrate. Therefore the free energy involved in extraction can be optimized by using a carefully selected solvent. In this paper we demonstrate the use of a solvatochromic model to predict the influence of solvent dipolarity, H-bond acidity and H-bond basicity on selectivity and yield of phenobarbital extraction. We also used this method to estimate the purity and yield of phenobarbital extraction in 12 poly(vinyl chloride) plasticizers and solvents. This approach can be generalized for assisting the selection of optimal solvent and provide insight into the rational design of solvent and receptor for industrial extractions.

Drug Contamination↗

Bicarbonate-sensitive cysteine induced elevation of extracellular aspartate and glutamate in rat hippocampus in vitro.

The effect of different concentrations of cysteine (0.125, 0.25, 0.5 and 1 mM) on the net efflux of endogenous amino acids was studied by the incubation of rat hippocampal slices. Addition of cysteine (1 mM) in bicarbonate containing low K+ medium (5 min) selectively increased the basal net efflux of glutamate and aspartate by 370% and 396%, respectively. High K+ media (50 mM) containing cysteine (1 mM) evoked the net efflux of glutamate and aspartate by 1454% and 1019%, respectively. The corresponding effects in control slices without cysteine were 669% and 404%, respectively. No changes were observed on the concentrations of GABA, glutamine and taurine. The cysteine oxidation products, cysteine sulfinate (0.5 microM) and cystine (0.25 mM) were without effects. The effect of cysteine (0.5 mM) was dramatically reduced in media with no added bicarbonate/CO2. Thus, cysteine in a bicarbonate-sensitive manner selectively increases the extracellular concentration of excitotoxic amino acids in adult rat brain in vitro, possibly by interfering with the carrier-mediated glutamate uptake/release.

Animals↗

Molecular recognition of phenobarbital in plasticizers equilibrium investigations on the solubility of the barbiturate artificial receptor and its binding to phenobarbital in plasticizers.

Environmental concern is renewing interest in selective, waste-free extractions. A recent report demonstrated an improved extraction of phenobarbital by means of a specifically designed molecular receptor. In that work, the solvent was CHCl3. The current work is the first step in extending extractions based on molecular recognition to reusable solvents, namely plasticizers. Phenobarbital aqueous/organic partition coefficients, receptor solubility, and phenobarbital-receptor-formation constants in several plasticizers and in their CHCl3 solutions are reported. In addition, by a thermodynamic cycle, the free energy for transfer of the barbiturate-receptor complex from CHCl3 to plasticizers has been calculated. Finally, the data have been displayed in coordinate systems representing extraction efficiency and selectivity. The most selective extraction medium yielding useful extraction efficiency is dioctyl phthalate.

Chemical Phenomena↗

Detection of bioactive oligopeptides after microbore HPLC with electrochemical detection of their Cu(II) complexes: effect of operating parameters on sensitivity and selectivity.

We used a microbore reversed phase column for acetonitrile/0.1% aqueous TFA gradient elution separation of peptides with the detection of their copper complexes by electrochemical detection. The copper complexes are formed in a short (1 or 1.5 min) postcolumn reactor following mixing of the eluent with the postcolumn reaction phase. Detection can be at an upstream anode or a downstream cathode of a dual-electrode electrochemical detector. The following parameters have been investigated for their effect on the sensitivity and the selectivity of the procedure: postcolumn pH, buffer type, temperature, reaction time, and anode potential. Of the 23 bioactive peptides used, there are several that fall into classes according to their chemical and electrochemical behavior with copper(II): those with a blocked terminal amine, those with aspartate in the third position, those that have an electroactive amino acid, and those that have a cyclic structure formed by the amide backbone through a Cys-Cys disulfide bridge. Depending on these attributes, the operating parameters have an influence on the sensitivity of the determination. Among the more well-defined results are the following. Uncomplicated peptides with a free amine terminus react rapidly in the postcolumn reactor and give signals in the range predicted by theory. There is evidence that longer peptides, and those with a blocked amine terminus, have a sensitivity limited by kinetic factors. The oxidations of tyrosine and tryptophan in peptides are dramatically influenced by buffer type at pH 9.8. At pH 8.0, there is no signal from several peptides in phosphate buffer, while in borate there is a signal.

Amino Acid Sequence↗

Optimization of a modified electrode for the sensitive and selective detection of alpha-dipeptides.

Sensitive and selective detection of dipeptides is important in neurochemistry. We have developed a flexible detection scheme for dipeptides based on a modified carbon electrode. The modification arises from the anodic treatment of the carbon electrode in alkaline solution. The flexibility of the detection scheme arises from the different conditions used in both the modification and the detection. It is shown that the modification step requires the presence of cupric ion, while the detection step does not. On the other hand, it is shown that the presence of copper in the detection eluent, as well as the pH of the environment, can be used in controlling the selectivity of the modified electrode. For example, the modified electrode is more selective for alpha-dipeptides over beta- and gamma-dipeptides as well as amino acids at pH 9.8, whereas it is selective for all dipeptides over amino acids at pH 8.0. Detection limits of dipeptides on the order of 10 nM were achieved at pH 8.0 by flow-injection analysis with a knotted Teflon tubing connecting the injector and the detector that gave a typical peak volume of about 0.50 ml at 1.0 ml/min. From surface analysis it is shown that the oxygenation of the glassy carbon electrode gives rise to the selectivity. The oxidation of dipeptides at the modified electrode is completely inhibited by 10 mM Mg2+ in the eluent.

Chromatography, Liquid↗

Fluorescence, photodestruction, photoionization and thermal degradation of o-phthalaldehyde/beta-mercaptoethanol-labelled aliphatic alpha-oligopeptides.

Photophysical and photochemical properties of o-phthalaldehyde/beta-mercaptoethanol-labelled aliphatic alpha-peptides were investigated. It is found that alpha-peptide derivatives have lower fluorescence quantum yields, higher photodestruction quantum yields and lower yields for formation of solvated electrons as compared to amino acid and simple alkylamine derivatives in aqueous alkaline solution. These properties of the alpha-peptide derivatives sets narrow limits for their utilization in laser-based (high light intensity) detector systems. In contrast, the thermal stability of the peptide derivatives was found to be severalfold higher than for the parent amino acid derivatives. The differential rates of thermal derivative degradation could be utilized in a new approach towards selective determination of peptides. determination of peptides. determination of peptides.

Mercaptoethanol↗

Sensitivity and selectivity of the electrochemical detection of the copper(II) complexes of bioactive peptides, and comparison to model studies by rotating ring-disc electrode.

Post-column reaction of peptides with Cu(II) can be used for the electrochemical detection of peptides as their biuret complexes. Understanding of the behavior (sensitivity at the anode and cathode in the dual-series electrochemical detector) of the system is facilitated through the observation of the rotating ring disc voltammetry of some model compounds. In operation, the anodic signal from the oxidation of the Cu(II)-peptide to the Cu(III) form can be used to detect peptides, or the downstream cathode can be used to detect the Cu(III) form. The signals appear at about 0.4 V (anode) for tetra- and longer peptides, 0.65 V for tripeptides. The anode signal is augmented by tyrosine (oxidation at 0.4-0.5 V) and tryptophan (0.5-0.6 V). If the cathode is used as the detector in a two working electrode cell, the sensitivity depends on the stability of the Cu(III) product. This is peptide dependent, but the signal is significant and useful analytically. Twenty-three bioactive peptides in two groups, naturally electrochemically active and naturally electrochemically silent, and several model compounds have been studied. Both naturally electrochemically active peptides (contain tyrosine and/or tryptophan) and naturally electrochemically silent peptides have been studied. Chromatography with an acetonitrile gradient has been used to separate the peptides in each group. Detection limits are for non-electroactive peptides in the range of 16-100 fmol (10- microliters injection 1.6-10 nM, 100 microliters injection 0.16-1.0 nM), and for electroactive peptides in the range of 6-40 fmol (0.6-4.0 nM for a 10- microliters injection and 60-400 pM for a 100- microliters injection). A tryptic digest of bovine cytochrome c is easily seen at 100 nM.

Amino Acid Sequence↗