PubMed Health⌕ Search

Biomedical subjects

S G Weber

Publications and source records attributed to S G Weber.

At least 37 records · Page 2Linked to original sources

Rotating ring-disk electrode study of copper(II) complexes of the model peptides triglycine, tetraglycine, and pentaglycine.

The reversible electrochemistry of the Cu(II)/Cu(III) couple was investigated for the copper(II) complexes of triglycine (G3), tetraglycine (G4), and pentaglycine (G5) in alkaline solution using a rotating ring-disk electrode (RRDE). The study was motivated by the need to elucidate electrochemical processes occurring in dual electrode postcolumn detection of peptides. The disk electrode served as the anode and the ring electrode as the cathode. The electrode was used in both linear sweep voltammetry and constant potential, varied rotation speed modes. Redox waves for two generic forms of the complexes, Cu(II)-NNNN and Cu(II)-NNNO, were identified, with respective E1/2 values of approximately 0.45 and 0.7 V. It was found that the G3 complex underwent an ECE-like process at the anode that magnified the anodic signal and suppressed the cathodic signal. The G4 and G5 complexes were subject to two CE processes, the C reactions being (i) deprotonation of Cu(II)-NNNO to Cu(II)-NNNN and (ii) loss of hydroxide ion by Cu(II)-NNN(OH-), a variant of Cu(II)-NNNO. An additional C reaction, dissociation of a carbonate variant of Cu(II)-NNNO, occurred in 0.2 M carbonate buffer. Visible absorbance measurements assisted in assignment of these forms. Measurements of diffusion coefficients of the complexes were performed by Taylor-Aris laminar flow axial dispersion measurements. The analytical implications for these findings are discussed.

Buffers↗

Determination of the pharmaceutical peptide TP9201 by post-column reaction with copper(II) followed by electrochemical detection.

An electrochemical detection method was applied to the determination of the synthetic peptide TP9201 (Telios Pharmaceuticals). The method utilizes reversed-phase HPLC, followed by post-column formation of Cu(II)-peptide complexes to render peptides electrochemically active via the Cu(III/II) couple. TP9201 is cyclic and N-amidated; the lack of a free amine precludes the use of typical fluorescent labeling reagents. Neither the cyclic structure nor the N-amidation prevented the copper complexation reaction, however. The detection limit in bovine serum was 20 nM, limited by interfering sample peaks, and the detector response was linear in a range 10-400 nM.

Amino Acid Sequence↗

Enhanced extraction of phenobarbital from serum with a designed artificial receptor.

The primary goal of this work was to determine whether artificial receptors that function on the basis of molecular recognition have analytical capabilities. As an example of such a receptor, we have chosen one directed toward barbiturates. Chloroform enriched with this artificial receptor (1 mM) can extract more than 90% of the phenobarbital from a 20 microM phenobarbital solution in human control serum using a volume ratio (organic/serum) as small as 0.5. In the absence of this receptor, the volume ratio must be greater than 10 to achieve similar extraction efficiencies. In addition to volume ratio, the role of pH, receptor concentration, and solvent type are discussed. The experimental results are found to be in good agreement with predictions based on chemical equilibria. Through the use of this and other similar receptors, the amount of organic solvent used in extractions can be minimized.

Barbiturates↗

Carbonized microcellular foam-based porous flow-through electrodes with unit coulometric efficiency.

The carbon foam used was pyrolyzed from PAN at 1100 degrees C. Its specific surface area is 21,000 cm-1 and its porosity is 0.97; thus, it is ideally suited for coulometric cells. Although the material is fragile, it can be bored with steel or glass tubing. The most effective cells consisted of cylindrical segments of foam which were from 0.5 to 3.0 mm long inside of a 1.0 mm in diameter glass tube. In the smallest cell, 0.5 mm long, the electrode volume was 0.4 microL, yet it yielded unit coulometric efficiency at 1.0 mL/min. The pressure required for higher flow rates caused electrode failure. Longer electrodes yielded cells with unit coulometric efficiency up to the system limits near 3 mL/min.

Carbon↗

Liquid chromatographic determination of acidic beta-aspartyl and gamma-glutamyl peptides in extracts of rat brain.

This work describes further development of our previously presented method for determination of acidic sulfur/phosphor-containing amino acids, gamma-glutamyl di/tripeptides, and beta-aspartyl dipeptides. Automated precolumn fluorogenic derivatization was performed with o-phthaldialdehyde/beta-mercaptoethanol and the derivatives were separated by reversed-phase liquid chromatography. The method was optimized for the analysis of brain tissue extracts. Due to the complex sample matrix, three separation schemes with complementary selectivities were developed. Different extraction protocols were evaluated and sonication of frozen tissue powder in methanol-H2O (9:1, v/v) yielded the highest recoveries and precision. beta-Mercaphtoethanol and EDTA were added to the extraction media to inhibit spontaneous oxidation of thiol-containing amino compounds. Analyte identification was based on retention times and recovery of standards added to extracts. The following compounds were identified in rat cerebral cortex (mean tissue concentration +/- SD, n = 6): gamma-glutamylglutamine (38.5 +/- 12.6 microM), gamma-glutamylglutamate (14.4 +/- 6.0 microM), gamma-glutamyltaurine (4.9 +/- 2.2 microM), beta-aspartylglycine (4.0 +/- 0.4 microM), beta-aspartyltaurine (3.7 +/- 0.6 microM), O-phosphoserine (3.2 +/- 0.8 microM), gamma-glutamylcysteine (1.9 +/- 0.3 microM), gamma-glutamylglycine (1.1 +/- 0.1 microM), and gamma-glutamylcysteateglycine (0.8 +/- 0.1 microM). In addition over 15 unidentified components were found. Cysteate, cysteine sulfinate, homocysteate, homocysteine sulfinate, O-Sulfoserine, gamma-glutamylaspartate, gamma-glutamylcysteate, gamma-glutamylhistidine, and beta-aspartylalanine were not present at concentrations above 1 microM.

Animals↗

Electrical double-layer models of ion-modified (ion-pair) reversed-phase liquid chromatography.

Stoichiometric models of ion-modified reversed-phase liquid chromatography are based on chemical equilibria between ionic modifiers and analyte. These are briefly discussed. Non-stoichiometric models portray the ionic solute as being under the summed influence of all of the ions in the system. Chromatographic theories have been developed that are based on the Poisson-Boltzmann equation, which quantitates the summed influence of the ions in the system on the solute. These ideas and quantitative predictions are described and are critically discussed.

Chromatography, Liquid↗

Electrochemical detection of dipeptides with selectivity against amino acids.

Electrolysis of a basic mobile phase containing biuret reagent [Cu(II) and a tartrate salt] at high (> 1.2 V vs. Ag/AgCl) potentials modifies the glassy carbon electrode. This modified anode oxidizes dipeptides, yielding signals expected for a one-electron transfer, even at low (down to 0.7 V vs. Ag/AgCl) potentials and in the absence of intentionally added copper(II) ion in the reagent or mobile phase. The same modification demonstrates a selectivity to alpha-dipeptides over amino acids that is unprecedented. The product of the anodic reaction is reduced at a downstream cathode at low positive potentials. Sensitivities for several amino acids and dipeptides are reported under several conditions. Neither the anodic nor the cathodic signals for the buiret complex of the tripeptide Ala-Ala-Ala are significantly altered because of the modification.

Amino Acid Sequence↗

Influence of tyrosine on the dual electrode electrochemical detection of copper(II)-peptide complexes.

The bluret reaction makes peptides electrochemically active. This is the basis of an electrochemical method for the detection of peptides following their liquid chromatographic separation. This paper discusses the influence of tyrosine, an electroactive amino acid, on the detection of Cu(II)-peptide (bluret) complexes containing it. The dual electrode detector has an upstream anode and a downstream cathode. Tyrosine-containing peptides yield anodic signals that are approximately the sum of the tyrosine signal and the signal from the bluret complex of a nonelectroactive model peptide, phenylalanylglycyl-glycine (FGG). The cathodic signal is depressed in comparison to FGG. This is traced to the presence of an intramolecular reaction between Cu(III) and a reaction product resulting from the oxidation of the tyrosinyl residue. The rate constant for the corresponding intermolecular reaction is significant (10(6)-10(7) M-1 s-1), but in practical analytical situations, the concentrations of the reactants will be small, so the reaction will not be a major factor. Sensitivities for several bioactive peptides are reported. The dependence of the signals on the position of tyrosine in a tripeptide is also studied.

Amino Acid Sequence↗

Polar bonded phase with the zwitterionic sulfobetaine functional group. Comparison to silica.

A new bonded phase has been prepared by the reaction of n-propylsultone with dimethylaminopropylsilane-modified silica. The resulting functional group is the zwitterionic ammonium propane sulfonate. Chromatographic solvents based on three strong solvents, methylene chloride, diisopropyl ether and acetonitrile, were prepared in hexane. Solutes, including substituted benzenes, polycyclic aromatic hydrocarbons and low-molecular-weight species commonly used as solvents, were chromatographed on the zwitterionic phase and on silica from the same supplier of the dimethylamino phase. The zwitterionic phase is a weaker adsorbent than silica and retentions are less influenced by the type of strong solvent employed, compared to silica. The retention (log k') of solutes on the zwitterionic phase is highly correlated with the free energy of transfer of solute from the vapor phase to water.

Adsorption↗

Electrochemical detection of oligopeptides through the precolumn formation of biuret complexes.

The relatively slow kinetics of formation of the electroactive Cu(II)-peptide complexes from larger (greater than 6 amino acids) peptides requires relatively high temperature and long reaction times for a postcolumn reactor. The precolumn incubation of bradykinin, Tyr8-bradykinin and insulin A chain with biuret reagent for 20 min at 60 degrees C leads to the formation of biuret complexes which can be subjected to chromatography in acidic or basic eluents. These complexes are detected electrochemically with a sensitivity similar to the Cu(II)-(ala)3 complex (1 nC/pmol at 1.0 ml/min). The influence of the column-packing material on the electrochemical detector response of the Cu-peptide complexes has also been studied.

Biuret↗

Tris(2,2'-bipyridine)ruthenium (II) as a peroxide-producing replacement for enzymes as chemical labels.

The concentration of the ruthenium-based label is determined from the rate of hydrogen peroxide production elicited by photolysis. Electron transfer quenching of the photoexcited label by methyl viologen (1,1'-dimethyl-4,4'bipyridinium dication, MV2+) and/or oxygen in the presence of EDTA generates hydrogen peroxide. Both flow injection and direct photolysis techniques were tested, with the latter showing better results. Direct photolysis is more sensitive, faster, requires only a 20 microliters sample volume, uses only 30 mW laser power and shows a smaller background. The presence of 5% normal human serum in the sample did not interfere with the measurements. Linear calibration curves were obtained in the nanomolar concentration range for goat antimouse antibody labeled with the ruthenium complex. The determination of membrane-surface-bound labeled IgG is accomplished by direct photolysis of a membrane that covers a platinum microelectrode.

2,2'-Dipyridyl↗

Chemical control of reaction time in an enzyme assay and feasibility of enzyme spot tests.

There are many circumstances in which the understanding of a patient's status would be improved by knowing one or more enzyme activities. Such data are routinely produced in clinical laboratories, but simple, noninstrumental tests for enzymes are a rarity, so their extralaboratory determination is also rare. The essential problem is that effective clinical determinations of enzyme activities are typically carried out by measuring reaction rates, so the reaction time needs to be controlled. The reaction time of a sample can be controlled by using a passive, ion exchange-based titration. In this work, OH-, H+, and quinidine have been used to stop the enzymes LDH (EC 1.1.1.27) (with H+ and OH-) and cholinesterase (EC 3.1.1.8) (with quinidine). The ion exchange material containing the enzyme-stopping ion is separated from the sample by a filter. The sample contains ions that can exchange with the enzyme-stopping ion in the ion exchange material, and it may contain species that buffer the enzyme-stopping ion. The reaction time is governed by the exchanging ion's concentration in the sample, the quantity of buffer in the sample, the thickness of the filter between the ion exchange material and the sample, and the temperature. A test for LDH requiring 50 microL of serum and no instrumentation can be made so that results from sera with elevated levels appear different than those with normal levels.

Cholinesterases↗

Electrochemical detection of dipeptides and dipeptide amides.

A postcolumn reagent is used to create electroactive species from non-electroactive peptides. The reagent, based on the classical biuret reagent, consists of Cu(II), tartrate, bicarbonate and base. The detection is by dual electrode electrochemical detection. N-Acetylated dipeptides are oxidized at pH 12 and low potential. Dipeptides and carboxy terminal dipeptide amides give useful signals at lower pH. The dipeptide amides react with Cu(II) as do the tripeptides to yield the electronic spectrum and electrochemistry of the biuret complex. The complexes formed from the dipeptides are reversibly oxidized at potentials greater than 0.85 V vs. Ag/AgCl, 3 M NaCl. Analytically useful signals are obtained for the dipeptide amides at sensitivities equivalent to the sensitivities for longer peptides, 3-5 nA/microM, while the sensitivities for the dipeptides are about an order of magnitude lower.

Amides↗

Microring electrode/optical waveguide: electrochemical characterization and application to electrogenerated chemiluminescence.

A novel optoelectrochemical microprobe has been developed that allows the combination of optical and electrochemical methods in a very small system. The key element is a gold-coated optical fiber polished to a flat surface, such that the gold forms a microring electrode surrounding the optical fiber. The electrochemistry of the microring has been characterized; cyclic voltammetric and chronoamperometric limiting currents agree well with published theoretical treatments. The probe has also been used for electrogenerated chemiluminescence with tris(2,2'-bypyridine)ruthenium(II) with persulfate in 50:50 MeCN:H2O. Detection limits of 4.3 X 10(-8) M Ru(bpy)3(2+) have been obtained.

Electrochemistry↗

Electrochemical detection of peptides.

A general method of wide applicability for the determination of peptides is described. Peptides longer than dipeptides react in the classical biuret reaction with Cu(II) to yield electroactive Cu(II)-peptide complexes that can be oxidized to the corresponding Cu(III) complexes. This allows the sensitive electrochemical detection of peptides following their separation by reversed-phase liquid chromatography. The reaction chemistry, which is reversible, allows for the determination of peptides that lack an electroactive group or a primary amine. Selectivity for a model peptide is 10(3)-10(4) over nonelectroactive amino acids.

Electrochemistry↗

Signal-to-noise ratio in microelectrode-array-based electrochemical detectors.

The signal-to-noise ratio at an electrode array depends on the electrode area, the perimeter-to-area ratio of the electroactive portion of the surface, the mass transfer coefficient of the analyte-electrode combination, the measurement bandwidth, and the sources and magnitudes of the noises. Simple models for chronoamperometry with an array in quiescent solution and for hydrodynamic current at an array in one wall of a rectangular conduit through which analyte-containing solution is following are given. Noises from seven sources, including environmental noises, are considered in a noise model. The signal and noise models are combined to yield a model for signal-to-noise ratio at array-based electrochemical detectors. There exists an optimum array density for a given area that depends on the noise power, noise resistance, the current density at a sparse array, and the current density at a solid electrode of the same area. Approximations that lead to simple expressions for the optimum electroactive area fraction and noise resistance lead to results that are in good agreement with more complex and less approximate calculations. Electrodes of millimeter dimensions consisting of about 1% active surface with electroactive "pieces" of micrometer dimensions are anticipated to yield detection limits of about 1 fmol injected into a typical packed-column liquid chromatograph. This corresponds to about 10(-10) M analyte in the detector and about an order of magnitude improvement over solid electrodes.

Electrochemistry↗

Control of molecular weight selectivity in electrode modifications based on phase-inversion cellulose acetate membranes.

Modified electrodes with size selectivity are required for electrochemical blosensors and for analysis of biological samples. The phase-inversion process for making reverse osmosis membranes is used to make modified electrodes with the goals of decreasing thickness, improving response time, and understanding the influence of both casting solution composition and casting conditions on the resultant membrane's porosity. Poly(ethylene glycol) esters of ferrocene-carboxylic acid are used for the determination of the membrane's response time, selectivity, and structure. It is shown that there is an optimum composition range of greater than 95% acetone, less than 2% cellulose acetate, and less than 5% aqueous Mg(CIO4)2. This composition range gives the minimum response time (greater than 90% of maximum signal is obtained in less than 7 min), maximum reproducibility (less than 20% relative error), and best size selectivity in the few thousand daltons range.

Cellulose↗