PubMed Health⌕ Search

Biomedical subjects

S Kuruoğlu

Publications and source records attributed to S Kuruoğlu.

3 recordsLinked to original sources

Evolving experience in the management of pleural empyema.

The objective of this study was to determine treatment strategies for children admitted with pleural empyema. We reviewed the medical records of 93 consecutive patients with pleural empyema who presented in the last three years. Mean age was 3.8 years (range 3.5 months to 14 years) and the male to female ratio was 52 : 41. The left side was involved in 51 (54.8 %) cases and there was only one case with bilateral effusion. After the chest X-ray and analysis of pus obtained by thoracocentesis, the initial treatment modality was chest tube drainage in 81 (87 %) patients. Children required chest tube drainage for an average of 11.9 +/- 4.8 days. Out of the 81 children, 6 needed thoracotomy due to organized pleural fluid and another 4, who developed loculated pleural effusions, were treated with intrapleural urokinase (UK) administration. Twelve children, who had a delayed presentation with organized loculated pleural fluid and pleural thickening, underwent decortication and one, who was found to have a foreign body, found during surgery, needed an upper lobe resection. Medical management with adequate chest tube drainage and appropriate antibiotics has resulted in full resolution in the majority of patients with empyema. In cases of loculated pleural effusions identified at the early stages of the chest tube drainage, intrapleural UK administration was found to be a safe and efficient treatment modality. Thoracotomy should be reserved for late and organized empyema cases.

Adolescent↗

Effect of intraocular lens and anterior capsule opening type on posterior capsule opacification.

PURPOSE: To determine the effect of intraocular lens (IOL) type and anterior capsulectomy technique on the incidence of posterior capsule opacification. SETTING: Department of Ophthalmology, Medical Faculty, University of Ondokuz Mayis, Samsun, Turkey. METHODS: Three hundred two eyes of 294 patients were examined retrospectively after IOL implantation in the capsular bag performed between February 1991 and November 1996. Patients were divided into 3 groups according to IOL type: poly(methyl methacrylate) (PMMA); heparin-surface-modified PMMA (HSM PMMA); plate-haptic silicone. Envelope capsulectomy or continuous curvilinear capsulorhexis (CCC) was used. Mean follow-up was 27 months (range 12 to 33 months). RESULTS: Posterior capsule opacification developed in 47 cases (15.6%): 21.7% in the PMMA lens group after planned extracapsular cataract extraction (ECCE), 17.4% in the HSM PMMA lens group after planned ECCE, and 7.7% in the plate-haptic silicone lens group after phacoemulsification. Posterior capsule opacification occurred less in patients who had anterior capsulectomy using the CCC technique (11.5%) than in those having an envelope capsulectomy (24.5%) (P < .05). Posterior capsule opacification was significantly less in eyes with a capsular-bag-fixated plate-haptic silicone lens than in those with a PMMA or HSM PMMA IOL (P < .05). CONCLUSION: This study demonstrated that the anterior capsulectomy technique and the IOL type influence the incidence of PCO.

Aged↗

Does surgical technique influence cataract surgery contamination?

PURPOSE: To compare cataract surgery contamination rates in large-incision extracapsular cataract extraction (ECCE) and phacoemulsification (PE), we studied 65 cases prospectively. METHODS: Thirty-five cases were operated by large-incision ECCE (Group I) and 30 by PE (Group II). Conjunctival swab cultures were taken immediately before surgery and anterior chamber aspirate was taken for culture upon completion of surgery for each case. RESULTS: Anterior chamber cultures were positive in 22.8% of the cases in group I and 23% in Group II. Frequencies of contamination in each group were no different (x2: 0.22, p>0.05). When the contaminations were evaluated in relation to operating time, prolongation of the operating time raised the contamination rate in Group I (p<0.05) but not in Group II (p>0.05). Silicone and PMMA intraocular lenses (IOL) were tested to see whether they had any additional risk of contamination. The frequencies of contaminated silicone IOL implanted cases (6/26) and contaminated PMMA IOL implanted cases (8/39) were similar (x2: 0.36, p>0. 05). CONCLUSIONS: Although the architecture of the incision and irrigation dynamics provided an advantage to the PE technique as the operating time became longer, routine PE was not superior to classical ECCE with respect to contamination when performed in the same circumstances. Prolonging the operating time raised the contamination rate in classical ECCE.

Aqueous Humor↗