PubMed Health⌕ Search

PubMed · 11284482

Does surgical technique influence cataract surgery contamination?

Abstract

PURPOSE: To compare cataract surgery contamination rates in large-incision extracapsular cataract extraction (ECCE) and phacoemulsification (PE), we studied 65 cases prospectively. METHODS: Thirty-five cases were operated by large-incision ECCE (Group I) and 30 by PE (Group II). Conjunctival swab cultures were taken immediately before surgery and anterior chamber aspirate was taken for culture upon completion of surgery for each case. RESULTS: Anterior chamber cultures were positive in 22.8% of the cases in group I and 23% in Group II. Frequencies of contamination in each group were no different (x2: 0.22, p>0.05). When the contaminations were evaluated in relation to operating time, prolongation of the operating time raised the contamination rate in Group I (p<0.05) but not in Group II (p>0.05). Silicone and PMMA intraocular lenses (IOL) were tested to see whether they had any additional risk of contamination. The frequencies of contaminated silicone IOL implanted cases (6/26) and contaminated PMMA IOL implanted cases (8/39) were similar (x2: 0.36, p>0. 05). CONCLUSIONS: Although the architecture of the incision and irrigation dynamics provided an advantage to the PE technique as the operating time became longer, routine PE was not superior to classical ECCE with respect to contamination when performed in the same circumstances. Prolonging the operating time raised the contamination rate in classical ECCE.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Koç, Z Akçam, S Kuruoğlu, I Oge, M Günaydin. Does surgical technique influence cataract surgery contamination?. https://doi.org/10.1177/112067210101100107

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Intraluminal pressure response in Baerveldt tube shunts: a comparison of modification techniques.

PURPOSE: To design an apparatus for in vitro quantification of effects of modifications to nonvalved tube shunts, and to compare the effects of these modifications done to prevent early postoperative hypotony. MATERIALS AND METHODS: A testing apparatus was designed and constructed to measure intraluminal pressure (ILP) during constant infusion of balanced salt solution at 2 microL/min through Baerveldt tube shunts mounted on cadaver eyes. Three different modifications were performed and 3 shunts were used for each modification. The modifications were partial tube occlusion with a 3-0 Supramid suture, tube perforation with a 27-gauge needle on an occluded tube, and a 1.2 mm longitudinal venting slit on an occluded tube. RESULTS: The final steady state ILP for the 3-0 Supramid partially occluded tube ranged between 1.6 and 2.8 mm Hg over 3 trials with an average final steady state ILP of 2.0 mm Hg. The 27-gauge needle perforation produced ILPs of 4.6 to 8.2 mm Hg over 3 trials with an average final steady state pressure of 5.9 mm Hg. The 1.2 mm longitudinal venting slit produced an ILP range of 12.6 to 17.3 mm Hg over 3 trials with an average final steady state ILP of 14.8 mm Hg. The differences in final steady state ILP between the 3 modification techniques were statistically significant (P=0.00036). CONCLUSIONS: The 3-0 Supramid occlusion and the 27-gauge perforation techniques produced hypotony, whereas the 1.2 mm longitudinal venting slit produced acceptable pressures in vitro.

Aqueous Humor↗

Myocilin-associated exosomes in human ocular samples.

Mutations in myocilin result in ocular hypertension, likely due to decreased drainage of aqueous humor through the trabecular meshwork. Since less myocilin is found in the aqueous humor of those with disease-causing mutations, understanding myocilin's role in the aqueous humor is of clinical importance. Recently, myocilin was shown to exit cultured trabecular meshwork cells in association with shed vesicles called exosomes. To examine relevance of this finding in a physiological setting, the present study examined three different types of ocular samples for the presence of myocilin-associated exosomes. Using differential centrifugation steps, we found myocilin associated with exosomes isolated from effluent collected from human anterior segments in organ culture and aqueous humor obtained from human cadaveric eyes or from patients undergoing excisional surgery. Similar to results with cultured cells, myocilin associated predominately with exosomes in fresh samples, appeared mostly soluble at later times, and had biochemical properties (density of 1.13-1.19 g/ml in linear sucrose gradient) similar to those characteristics of exosomes. These data indicate that exosomes are present and may facilitate the transport of myocilin into the extracellular space of human ocular cells.

Aqueous Humor↗