The use of megavoltage CT (MVCT) images for dose recomputations.

Megavoltage CT (MVCT) images of patients are acquired daily on a helical tomotherapy unit (TomoTherapy, Inc., Madison, WI). While these images are used primarily for patient alignment, they can also be used to recalculate the treatment plan for the patient anatomy of the day. The use of MVCT images for dose computations requires a reliable CT number to electron density calibration curve. In this work, we tested the stability of the MVCT numbers by determining the variation of this calibration with spatial arrangement of the phantom, time and MVCT acquisition parameters. The two calibration curves that represent the largest variations were applied to six clinical MVCT images for recalculations to test for dosimetric uncertainties. Among the six cases tested, the largest difference in any of the dosimetric endpoints was 3.1% but more typically the dosimetric endpoints varied by less than 2%. Using an average CT to electron density calibration and a thorax phantom, a series of end-to-end tests were run. Using a rigid phantom, recalculated dose volume histograms (DVHs) were compared with plan DVHs. Using a deformed phantom, recalculated point dose variations were compared with measurements. The MVCT field of view is limited and the image space outside this field of view can be filled in with information from the planning kVCT. This merging technique was tested for a rigid phantom. Finally, the influence of the MVCT slice thickness on the dose recalculation was investigated. The dosimetric differences observed in all phantom tests were within the range of dosimetric uncertainties observed due to variations in the calibration curve. The use of MVCT images allows the assessment of daily dose distributions with an accuracy that is similar to that of the initial kVCT dose calculation.

Algorithms↗

Evaluation of a diode array for QA measurements on a helical tomotherapy unit.

A helical tomotherapy system is used in our clinic to deliver intensity-modulated radiation therapy (IMRT) treatments. Since this machine is designed to deliver IMRT treatments, the traditional field flatness requirements are no longer applicable. This allows the unit to operate without a field flatness filter and consequently the 400 mm wide fan beam is highly inhomogeneous in intensity. The shape of this beam profile is mapped during machine commissioning and for quality assurance purposes the shape of the beam profile needs to be monitored. The use of a commercial diode array for quality assurance measurements is investigated. Central axis beam profiles were acquired at different depths using solid water built-up material. These profiles were compared with ion chamber scans taken in a water tank to test the accuracy of the diode array measurements. The sensitivity of the diode array to variations in the beam profile was checked. Over a seven week period, beam profiles were repeatedly measured. The observed variations are compared with those observed with an on-board beam profile monitor. The diode measurements were in agreement with the ion chamber scans. In the high dose, low gradient region the average ratio between the diode and ion chamber readings was 1.000 +/- 0.005 (+/- 1 standard deviation). In the penumbra region the agreement was poorer but all diodes passed the distance to agreement (DTA) requirement of 2 mm. The trend in the beam profile variations that was measured with the diode array device was in agreement with the on-board monitor. While the calculated amount of variation differs between the devices, both were sensitive to subtle variations in the beam profile. The diode array is a valuable tool to quickly and accurately monitor the beam profile on a helical tomotherapy unit.

Evaluation Studies as Topic↗

Ultrasonographic guidance for spinal extracranial radiosurgery: technique and application for metastatic spinal lesions.

OBJECT: The relatively stationary anatomy of the intracranial compartment has allowed the development of stereotactic radiosurgery as an effective treatment option for many intracranial lesions. Difficulty in accurately tracking extracranial targets has limited its development in the treatment of these lesions. The ability to track extracranial structures in real time with ultrasound images allows a system to upgrade and interface pretreatment volumetric images for extracranial applications. In this report the authors describe this technique as applied to the treatment of localized metastatic spinal disease. METHODS: The extracranial stereotactic system consists of an optically tracked ultrasonography unit that can be registered to a linear accelerator coordinate system. Stereotactic ultrasound images are acquired following patient positioning, based on a pretreatment computerized tomography (CT) simulation. The soft-tissue shifts between the virtual CT-based treatment plan and the actual treatment are determined. The degree of patient offset is tracked and used to correct the treatment plan. The ultrasonography-based stereotactic navigation system is accurate to within an approximate means of 1.5 mm based on testing with an absolute coordinate phantom. A radiosurgical treatment was delivered using the system for localization of a metastatic spinal lesion. Compared with the virtual CT simulation, the actual treatment plan isocenter was shifted 12.2 mm based on the stereotactic ultrasound image. The patient was treated using noncoplanar beams to a dose of 15.0 Gy to the 80% isodose shell in a single fraction. CONCLUSIONS: A system for high-precision radiosurgical treatment of metastatic spinal tumors has been developed, tested, and applied clinically. Optical tracking of the ultrasonography probe provides real-time tracking of the patient anatomy and allows computation of the target displacement prior to treatment delivery. The results reported here suggest the feasibility and safety of the technique.

Antineoplastic Combined Chemotherapy Protocols↗

Radiosurgery using a stereotactic headframe system for irradiation of brain tumors in dogs.

Radiation therapy of brain tumors in dogs typically involves administration of multiple fractions over several weeks. Fractionation is used to minimize damage to normal tissue. Radiosurgery uses multiple non-coplanar stereotactically focused beams of radiation in a series of arcs to deliver a single dose to the target with extreme accuracy. The large number of beams facilitates a high degree of conformation between the treatment area and the target tumor and allows for a steep dose gradient; the use of nonintersecting arcs minimizes exposure of normal tissue. Computed tomography with a stereotactic localizer secured to the skull allows generation of a 3-dimensional image of the target and provides accurate spatial coordinates for computerized treatment planning and delivery. Three dogs were treated with radiosurgery, using 1,000 to 1,500 cGy. A linear accelerator mounted on a rotating gantry was used to generate and deliver the radiation. Two dogs with meningiomas survived 227 and 56 weeks after radiosurgery. A dog with an oligodendroglioma survived 66 weeks. No complications were observed following the use of this technique.

Animals↗

Initial clinical experience with frameless stereotactic radiosurgery: analysis of accuracy and feasibility.

PURPOSE: To report on preliminary clinical experience with a novel image-guided frameless stereotactic radiosurgery system. METHODS AND MATERIALS: Fifteen patients ranging in age from 14 to 81 received radiosurgery using a commercially available frameless stereotactic radiosurgery system. Pathologic diagnoses included metastases (12), recurrent primary intracranial sarcoma (1), recurrent central nervous system (CNS) lymphoma (1), and medulloblastoma with supratentorial seeding (1). Treatment accuracy was assessed from image localization of the stereotactic reference array and reproducibility of biteplate reseating. We chose 0.3 mm vector translation error and 0.3 degree rotation about each axis as the maximum tolerated misalignment before treating each arc. RESULTS: The biteplates were found on average to reseat with a reproducibility of 0.24 mm. The mean registration error from CT localization was found to be 0.5 mm, which predicts that the average error at isocenter was 0.82 mm. No patient treatment was delivered beyond the maximum tolerated misalignment. The radiosurgery treatment was delivered in approximately 25 min per patient. CONCLUSION: Our initial clinical experience with stereotactic radiotherapy using the infrared camera guidance system was promising, demonstrating clinical feasibility and accuracy comparable to many frame-based systems.

Adolescent↗

Optically guided intensity modulated radiotherapy.

BACKGROUND AND PURPOSE: Previously, we reported on development of an optically guided system for 3D conformal intracranial radiotherapy using multiple noncoplanar fixed fields. In this paper we report on the extension of our system for stereotactic fractionated radiotherapy to include intensity modulated static ports. METHODS AND MATERIALS: A 3D treatment plan with maximum beam separation is developed in the stereotactic space established by an optically guided system. Gantry angles are chosen such that each beam has a unique entrance and exit pathway, avoids the critical structures, and has a minimal beam's eye view projection. Once, a satisfactory treatment plan is found using this geometric approach an inverse treatment plan is developed using the beam portals established previously. The purpose of adding inverse planing is two fold, on the one hand it allows further reduction of margins around the PTV, while on the other hand it affords the possibility of conformal avoidance of critical structures that are close to or abut the PTV. RESULTS: The use of the optically guided system in conjunction with intensity modulated noncoplanar radiotherapy treatment planning using fixed fields allows the generation of highly conformal treatment plans that exhibit smaller 90, 70, and 50% of prescription dose isodose volumes, improved PITV ratios, comparable or improved EUD, smaller NTD(mean) for the critical structures, and an inhomogeneity index that is within generally accepted limits. CONCLUSION: Because optically guided technology improves the accuracy of patient localization relative to the linac isocenter and allows real-time monitoring of patient position, the planning target volume needs to be corrected only for the limitations of image resolution. Intensity modulated static beam radiotherapy planning then provides the user the ability to further reduce margins on the PTV and to conform very closely to this smaller target volume, and enhances the normal tissue sparing, and high degree of conformality possible with 3D conformal radiotherapy. In addition, since optically guided technology affords improved patient localization and online monitoring of patient position during treatment delivery it allows for safe and efficient delivery of intensity modulated radiotherapy.

Algorithms↗

Isotropic beam bouquets for shaped beam linear accelerator radiosurgery.

In stereotactic radiosurgery and radiotherapy treatment planning, the steepest dose gradient is obtained by using beam arrangements with maximal beam separation. We propose a treatment plan optimization method that optimizes beam directions from the starting point of a set of isotropically convergent beams, as suggested by Webb. The optimization process then individually steers each beam to the best position, based on beam's-eye-view (BEV) critical structure overlaps with the target projection and the target's projected cross sectional area at each beam position. This final optimized beam arrangement maintains a large angular separation between adjacent beams while conformally avoiding critical structures. As shown by a radiosurgery plan, this optimization method improves the critical structure sparing properties of an unoptimized isotropic beam bouquet, while maintaining the same degree of dose conformity and dose gradient. This method provides a simple means of designing static beam radiosurgery plans with conformality indices that are within established guidelines for radiosurgery planning, and with dose gradients that approach those achieved in conventional radiosurgery planning.

Dose-Response Relationship, Radiation↗

Calibration of three-dimensional ultrasound images for image-guided radiation therapy.

A new technique of patient positioning for radiotherapy/radiosurgery of extracranial tumours using three-dimensional (3D) ultrasound images has been developed. The ultrasound probe position is tracked within the treatment room via infrared light emitting diodes (IRLEDs) attached to the probe. In order to retrieve the corresponding room position of the ultrasound image, we developed an initial ultrasound probe calibration technique for both 2D and 3D ultrasound systems. This technique is based on knowledge of points in both room and image coordinates. We first tested the performance of three algorithms in retrieving geometrical transformations using synthetic data with different noise levels. Closed form solution algorithms (singular value decomposition and Horn's quaternion algorithms) were shown to outperform the Hooke and Jeeves iterative algorithm in both speed and accuracy. Furthermore, these simulations show that for a random noise level of 2.5, 5, 7.5 and 10 mm, the number of points required for a transformation accuracy better than 1 mm is 25, 100, 200 and 500 points respectively. Finally, we verified the tracking accuracy of this system using a specially designed ultrasound phantom. Since ultrasound images have a high noise level, we designed an ultrasound phantom that provides a large number of points for the calibration. This tissue equivalent phantom is made of nylon wires, and its room position is optically tracked using IRLEDs. By obtaining multiple images through the nylon wires, the calibration technique uses an average of 300 points for 3D ultrasound volumes and 200 for 2D ultrasound images, and its stability is very good for both rotation (standard deviation: 0.4 degrees) and translation (standard deviation: 0.3 mm) transformations. After this initial calibration procedure, the position of any voxel in the ultrasound image volume can be determined in world space, thereby allowing real-time image guidance of therapeutic procedures. Finally, the overall tracking accuracy of our 3D ultrasound image-guided positioning system was measured to be on average 0.2 mm, 0.9 mm and 0.6 mm for the AP, lateral and axial directions respectively.

Algorithms↗

Analysis of risk factors associated with radiosurgery for vestibular schwannoma.

OBJECT: The aim of this study was to identify factors associated with delayed cranial neuropathy following radiosurgery for vestibular schwannoma (VS or acoustic neuroma) and to determine how such factors may be manipulated to minimize the incidence of radiosurgical complications while maintaining high rates of tumor control. METHODS: From July 1988 to June 1998, 149 cases of VS were treated using linear accelerator radiosurgery at the University of Florida. In each of these cases, the patient's tumor and brainstem were contoured in 1-mm slices on the original radiosurgical targeting images. Resulting tumor and brainstem volumes were coupled with the original radiosurgery plans to generate dose-volume histograms. Various tumor dimensions were also measured to estimate the length of cranial nerve that would be irradiated. Patient follow-up data, including evidence of cranial neuropathy and radiographic tumor control, were obtained from a prospectively maintained, computerized database. The authors performed statistical analyses to compare the incidence of posttreatment cranial neuropathies or tumor growth between patient strata defined by risk factors of interest. One hundred thirty-nine of the 149 patients were included in the analysis of complications. The median duration of clinical follow up for this group was 36 months (range 18-94 months). The tumor control analysis included 133 patients. The median duration of radiological follow up in this group was 34 months (range 6-94 months). The overall 2-year actuarial incidences of facial and trigeminal neuropathies were 11.8% and 9.5%, respectively. In 41 patients treated before 1994, the incidences of facial and trigeminal neuropathies were both 29%, but in the 108 patients treated since January 1994, these rates declined to 5% and 2%, respectively. An evaluation of multiple risk factor models showed that maximum radiation dose to the brainstem, treatment era (pre-1994 compared with 1994 or later), and prior surgical resection were all simultaneously informative predictors of cranial neuropathy risk. The radiation dose prescribed to the tumor margin could be substituted for the maximum dose to the brainstem with a small loss in predictive strength. The pons-petrous tumor diameter was an additional statistically significant simultaneous predictor of trigeminal neuropathy risk, whereas the distance from the brainstem to the end of the tumor in the petrous bone was an additional marginally significant simultaneous predictor of facial neuropathy risk. The overall radiological tumor control rate was 93% (59% tumors regressed, 34% remained stable, and 7.5% enlarged), and the 5-year actuarial tumor control rate was 87% (95% confidence interval [CI] 76-98%). Analysis revealed that a radiation dose cutpoint of 10 Gy compared with more than 10 Gy prescribed to the tumor margin yielded the greatest relative difference in tumor growth risk (relative risk 2.4, 95% CI 0.6-9.3), although this difference was not statistically significant (p = 0.207). CONCLUSIONS: Five points must be noted. 1) Radiosurgery is a safe, effective treatment for small VSs. 2) Reduction in the radiation dose has played the most important role in reducing the complications associated with VS radiosurgery. 3) The dose to the brainstem is a more informative predictor of postradiosurgical cranial neuropathy than the length of the nerve that is irradiated. 4) Prior resection increases the risk of late cranial neuropathies after radiosurgery. 5) A prescription dose of 12.5 Gy to the tumor margin resulted in the best combination of maximum tumor control and minimum complications in this series.

Adolescent↗

A geometrically based method for automated radiosurgery planning.

PURPOSE: A geometrically based method of multiple isocenter linear accelerator radiosurgery treatment planning optimization was developed, based on a target's solid shape. METHODS AND MATERIALS: Our method uses an edge detection process to determine the optimal sphere packing arrangement with which to cover the planning target. The sphere packing arrangement is converted into a radiosurgery treatment plan by substituting the isocenter locations and collimator sizes for the spheres. RESULTS: This method is demonstrated on a set of 5 irregularly shaped phantom targets, as well as a set of 10 clinical example cases ranging from simple to very complex in planning difficulty. Using a prototype implementation of the method and standard dosimetric radiosurgery treatment planning tools, feasible treatment plans were developed for each target. The treatment plans generated for the phantom targets showed excellent dose conformity and acceptable dose homogeneity within the target volume. The algorithm was able to generate a radiosurgery plan conforming to the Radiation Therapy Oncology Group (RTOG) guidelines on radiosurgery for every clinical and phantom target examined. CONCLUSIONS: This automated planning method can serve as a valuable tool to assist treatment planners in rapidly and consistently designing conformal multiple isocenter radiosurgery treatment plans.

Algorithms↗

A high-precision system for conformal intracranial radiotherapy.

PURPOSE: Currently, optimally precise delivery of intracranial radiotherapy is possible with stereotactic radiosurgery and fractionated stereotactic radiotherapy. We report on an optimally precise optically guided system for three-dimensional (3D) conformal radiotherapy using multiple noncoplanar fixed fields. METHODS AND MATERIALS: The optically guided system detects infrared light emitting diodes (IRLEDs) attached to a custom bite plate linked to the patient's maxillary dentition. The IRLEDs are monitored by a commercially available stereo camera system, which is interfaced to a personal computer. An IRLED reference is established with the patient at the selected stereotactic isocenter, and the computer reports the patient's current position based on the location of the IRLEDs relative to this reference position. Using this readout from the computer, the patient may be dialed directly to the desired position in stereotactic space. The patient is localized on the first day and a reference file is established for 5 different couch positions. The patient's image data are then imported into a commercial convolution-based 3D radiotherapy planning system. The previously established isocenter and couch positions are then used as a template upon which to design a conformal 3D plan with maximum beam separation. RESULTS: The use of the optically guided system in conjunction with noncoplanar radiotherapy treatment planning using fixed fields allows the generation of highly conformal treatment plans that exhibit a high degree of dose homogeneity and a steep dose gradient. To date, this approach has been used to treat 28 patients. CONCLUSION: Because IRLED technology improves the accuracy of patient localization relative to the linac isocenter and allows real-time monitoring of patient position, one can choose treatment-field margins that only account for beam penumbra and image resolution without adding margin to account for larger and poorly defined setup uncertainty. This approach enhances the normal tissue sparing, high degree of conformality, and homogeneity characteristics possible with 3D conformal radiotherapy.

Brain Neoplasms↗

Calculation of cranial nerve complication probability for acoustic neuroma radiosurgery.

PURPOSE: Estimations of complications from stereotactic radiosurgery usually rely simply on dose-volume or dose-diameter isoeffect curves. Due to the sparse clinical data available, these curves have typically not considered the target location in the brain, target histology, or treatment plan conformality as parameters in the calculation. In this study, a predictive model was generated to estimate the probability of cranial neuropathies as a result of acoustic schwannoma radiosurgery. METHODS AND MATERIALS: The dose-volume histogram reduction scheme was used to calculate the normal tissue complication probability (NTCP) from brainstem dose-volume histograms. The model's fitting parameters were optimized to provide the best fit to the observed complication data for acoustic neuroma patients treated with stereotactic radiosurgery at the University of Florida. The calculation was then applied to the remainder of the patients in the database. RESULTS: The best fit to our clinical data was obtained using n = 0.04, m = 0.15, and alpha/beta = 2.1 Gy(-1). Although the fitting parameter m is relatively consistent with ranges found in the literature, both the volume parameter, n, and alpha/beta are much smaller than the values quoted in the literature. The fit to our clinical data indicates that brainstem, or possibly a specific portion of the brainstem, is more radiosensitive than the parameters in the literature indicate, and that there is very little volume effect; in other words, irradiation of a small fraction of the brainstem yields NTCPs that are nearly as high as those calculated for entire volume irradiation. These new fitting parameters are specific to acoustic neuroma radiosurgery, and the small volume effect that we observe may be an artifact of the fixed relationship of acoustic tumors to specific regions of the brainstem. Applying the model to our patient database, we calculate an average NTCP of 7.2% for patients who had no cranial nerve complications, and the average NTCP for was 66% for patients who sustained a cranial neuropathy. For the entire patient population, the actual percentage of patients suffering either facial or trigeminal neuropathy was 14.7%, whereas the calculated average NTCP was 14.8%. DISCUSSION: NTCP calculations using brainstem dose-volume histograms can be used to estimate the rate of cranial neuropathies from acoustic neuroma radiosurgery. More clinical data and further study will lead to refinement of the model with time.

Brain Stem↗

Image localization for frameless stereotactic radiotherapy.

PURPOSE: Infrared light-emitting diodes (IRLEDs) have been used for optic-guided stereotactic radiotherapy localization at the University of Florida since 1995. The current paradigm requires stereotactic head ring placement for the patient's first fraction. The stereotactic coordinates and treatment plan are determined relative to this head ring. The IRLEDs are attached to the patient via a maxillary bite plate, and the position of the IRLEDs relative to linac isocenter is saved to file. These positions are then recalled for each subsequent treatment to position the patient for fractionated therapy. The purpose of this article was to report a method of predicting the desired IRLED locations without need for the invasive head ring. METHODS AND MATERIALS: To achieve the goal of frameless optic-guided radiotherapy, a method is required for direct localization of the IRLED positions from a CT scan. Because it is difficult to localize the exact point of light emission from a CT scan of an IRLED, a new bite plate was designed that contains eight aluminum fiducial markers along with the six IRLEDs. After a calibration procedure to establish the spatial relationship of the IRLEDs to the aluminum fiducial markers, the stereotactic coordinates of the IRLED light emission points are determined by localizing the aluminum fiducial markers in a stereotactic CT scan. RESULTS: To test the accuracy of direct CT determination of the IRLED positions, phantom tests were performed. The average accuracy of isocenter localization using the IRLED bite plate was 0.65 +/- 0. 17 mm for these phantom tests. In addition, the optic-guided system has a unique compatibility with the stereotactic head ring. Therefore, the isocentric localization capability was clinically tested using the stereotactic head ring as the absolute standard. The ongoing clinical trial has shown the frameless system to provide a patient localization accuracy of 1.11 +/- 0.3 mm compared with the head ring. CONCLUSION: Optic-guided radiotherapy using IRLEDs provides a mechanism through which setup accuracy may be improved over conventional techniques. To date, this optic-guided therapy has been used only as a hybrid system that requires use of the stereotactic head ring for the first fraction. This has limited its use in the routine clinical setting. Computation of the desired IRLED positions eliminates the need for the invasive head ring for the first fraction. This allows application of optic-guided therapy to a larger cohort of patients, and also facilitates the initiation of extracranial optic-guided radiotherapy.

Algorithms↗

Stereotactic radiosurgery: techniques and clinical applications.

Radiation is a common treatment modality for cancer. Although commonly used, the treatment techniques of radiation delivery have changed substantially. One of the most important changes in implementation is the widespread application of stereotactic techniques and their acceptance into the mainstream of radiotherapeutic delivery. The distinguishing characteristics of stereotactic radiosurgery and its current and future application are important for all physicians to understand. This article discusses these treatment techniques and applications from the perspective of a surgical oncologist.

Brain Neoplasms↗

Image registration of BANG gel dose maps for quantitative dosimetry verification.

BACKGROUND: The BANG (product symbol SGEL, MGS Research Inc., Guilford, CT) polymer gel has been shown to be a valuable dosimeter for determining three-dimensional (3D) dose distributions. Because the proton relaxation rate (R2) of the gel changes as a function of absorbed dose, MR scans of the irradiated gel can be used to generate 3D dose maps. Previous work with the gel, however, has not relied on precise localization of the measured dose distribution. This has limited its quantitative use, as no precise correlation exists with the planned distribution. This paper reports on a technique for providing this correlation, thus providing a quality assurance tool that includes all of the steps of imaging, treatment planning, dose calculation, and treatment localization. METHODS AND MATERIALS: The BANG gel formulation was prepared and poured into spherical flasks (15.3-cm inner diameter). A stereotactic head ring was attached to each flask. Three magnetic resonance imaging (MRI) and computed tomography (CT) compatible fiducial markers were placed on the flask, thus defining the central axial plane. A high-resolution CT scan was obtained of each flask. These images were transferred to a radiosurgery treatment-planning program, where treatment plans were developed. The gels were irradiated using our systems for stereotactic radiosurgery or fractionated stereotactic radiotherapy. The gels were MR imaged, and a relative 3D dose map was created from an R2 map of these images. The dose maps were transferred to an image-correlation program, and then fused to the treatment-planning CT scan through a rigid body match of the MRI/CT-compatible fiducial markers. The fused dose maps were imported into the treatment-planning system for quantitative comparison with the calculated treatment plans. RESULTS: Calculated and measured isodose surfaces agreed to within 2 mm at the worst points within the in-plane dose distributions. This agreement is excellent, considering that the pixel resolution of the MRI dose maps is 1.56 x 1.56 mm, and the treatment-planning dose distributions were calculated on a 1-mm dose grid. All points within the dose distribution were well within the tolerances set forth for commissioning and quality assurance of stereotactic treatment-planning systems. Moreover, the quantitative evaluation presented here tests the accuracy of the entire treatment-planning and delivery process, including stereotactic frame rigidity, CT localization, CT/MR correlation, dose calculation, and radiation delivery. CONCLUSION: BANG polymer gel dosimetry coupled with image correlation provides quantitative verification of the accuracy of 3D dose distributions. Such quantitative evaluation is imperative to ensure the high quality of the 3D dose distributions generated and delivered by stereotactic and other conformal irradiation systems.

Gels↗

Linear accelerator radiosurgery for nonacoustic schwannomas.

PURPOSE: To analyze the results of nonacoustic schwannomas treated with linear accelerator stereotactic radiosurgery. METHODS AND MATERIALS: Between August 1989 and October 1997, 18 patients with nonacoustic schwannomas underwent stereotactic radiosurgery at the University of Florida. Nine patients had schwannomas located in the jugular foramen region, seven in the trigeminal nerve, and two in the facial nerve. Nine patients had initial subtotal resections and nine did not undergo surgical intervention. One of the 9 patients with subtotal resection was treated with radiosurgery for a recurrent tumor. Tumor volumes ranged from 0.7 to 15.4 cm3 with a mean volume of 5.5 cm3. Minimal tumor doses ranged from 10.0 to 15.0 Gy with a mean dose of 13.1 Gy. Treatment dose was specified to the 80% isodose shell in 11 patients (58%) and to the 70% isodose shell in the remaining patients. Ten patients (56%) were treated with a single isocenter, 6 patients (33%) with 2-4 isocenters, and 2 patients (11%) with greater than 5 isocenters. Follow-up ranged from 5 to75 months and the mean follow-up was 32 months. Ten patients (56%) had follow-up beyond 2 years and none were lost to follow-up. Local control was defined as clinically stable neurological status and/or stable or decreased tumor size on yearly follow-up MR imaging. RESULTS: Eighteen evaluable patients (100%) had local control after treatment. All were alive and progression-free at last follow-up. Six of 10 patients with follow-up MRI 2 years or more after treatment had tumor regression and 4 patients had stable disease. Three additional patients with an MRI at 1 year showed no tumor change. Four complications in 3 patients included one worsening of a preexisting VII nerve palsy, 2 patients with new onset of hearing loss, and one with ataxia. No surgical intervention or prolonged steroid use was necessary for any patient with complications. Five patients had improvement in preexisting neurologic deficits. CONCLUSIONS: Excellent preliminary tumor control rates and a favorable toxicity profile support the effectiveness of linear accelerator stereotactic radiosurgery for patients with nonacoustic schwannomas.

Adolescent↗

The midline dose distribution for a three-field radiotherapy technique.

At the University of Florida, head and neck cancer often is irradiated using parallel opposed lateral fields (with inferior borders slanted superiorly) and an anterior low neck field. A common criticism is that overlap may occur at the match-line junction of the three fields, resulting in an increased risk of radiation myelitis. One setup for treatment of the oropharynx and two for the larynx were irradiated in an anthropomorphic head and neck phantom made of tissue-equivalent polyacrylamide gel with a two-dimensional thermoluminescent dosimeter array in its sagittal midplane. The results showed that no excess radiation dose was measured at the junction of the three fields. The "spinal cord dose," as percentage of dose to the central axis of the primary field, was as follows: oropharynx setup, 15% to 100%; larynx setup with midline tracheal block, 10% to 90%; larynx setup without tracheal block, 10% to 90%. In conclusion, the University of Florida three-field technique for head and neck cancer produces no measured increase in dose at field junctions.

Acrylic Resins↗