Image localization for frameless stereotactic radiotherapy.

Abstract

PURPOSE: Infrared light-emitting diodes (IRLEDs) have been used for optic-guided stereotactic radiotherapy localization at the University of Florida since 1995. The current paradigm requires stereotactic head ring placement for the patient's first fraction. The stereotactic coordinates and treatment plan are determined relative to this head ring. The IRLEDs are attached to the patient via a maxillary bite plate, and the position of the IRLEDs relative to linac isocenter is saved to file. These positions are then recalled for each subsequent treatment to position the patient for fractionated therapy. The purpose of this article was to report a method of predicting the desired IRLED locations without need for the invasive head ring. METHODS AND MATERIALS: To achieve the goal of frameless optic-guided radiotherapy, a method is required for direct localization of the IRLED positions from a CT scan. Because it is difficult to localize the exact point of light emission from a CT scan of an IRLED, a new bite plate was designed that contains eight aluminum fiducial markers along with the six IRLEDs. After a calibration procedure to establish the spatial relationship of the IRLEDs to the aluminum fiducial markers, the stereotactic coordinates of the IRLED light emission points are determined by localizing the aluminum fiducial markers in a stereotactic CT scan. RESULTS: To test the accuracy of direct CT determination of the IRLED positions, phantom tests were performed. The average accuracy of isocenter localization using the IRLED bite plate was 0.65 +/- 0. 17 mm for these phantom tests. In addition, the optic-guided system has a unique compatibility with the stereotactic head ring. Therefore, the isocentric localization capability was clinically tested using the stereotactic head ring as the absolute standard. The ongoing clinical trial has shown the frameless system to provide a patient localization accuracy of 1.11 +/- 0.3 mm compared with the head ring. CONCLUSION: Optic-guided radiotherapy using IRLEDs provides a mechanism through which setup accuracy may be improved over conventional techniques. To date, this optic-guided therapy has been used only as a hybrid system that requires use of the stereotactic head ring for the first fraction. This has limited its use in the routine clinical setting. Computation of the desired IRLED positions eliminates the need for the invasive head ring for the first fraction. This allows application of optic-guided therapy to a larger cohort of patients, and also facilitates the initiation of extracranial optic-guided radiotherapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S L Meeks, F J Bova, T H Wagner, J M Buatti, W A Friedman, K D Foote. 2000-03-15. Image localization for frameless stereotactic radiotherapy.. https://doi.org/10.1016/s0360-3016(99)00536-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A note on a generalized single step theory for any number of hierarchical genomic matrices.

BACKGROUND: The Single Step algorithm allows combining information from genotyped and un-genotyped individuals, provided they are connected by a pedigree. However, current single step theory is limited to a single list of markers. RESULTS: We present a generalized single step (GSS) method that can accommodate any number of hierarchical molecular datasets (e.g. sequence, high and low density arrays) and pedigree, avoiding imputation. We prove that a similar efficient inversion algorithm exists. The method is recursive, starting with the highest marker density scenario. We illustrate the method with simulation and show that GSS can increase predictive accuracy compared to standard single step. R code is provided so that custom scenarios can be easily compared, either with simulated or real data. CONCLUSION: The method developed generalizes extant single step theory to any number of hierarchical molecular relationship matrices, broadening the scenarios where single step can be applied. A topic of particular interest can be ecology field data or human populations where pedigree is not available, but where samples sequenced and genotyped at different densities can exist. GSS can also be a useful tool to optimize allocation of genotyping and / or sequencing resources.

Algorithms↗

cgDist: Nucleotide-level distance calculation from cgMLST allelic profiles.

Bacterial genomic surveillance requires balancing computational efficiency with genetic resolution for effective cluster investigation. cgMLST distance calculations treat all allelic differences as equivalent units, obscuring nucleotide-level variation. Furthermore, single nucleotide polymorphism-based pipelines provide finer resolution at substantially higher computational cost, which limits their routine deployment in surveillance laboratories. We present cgDist, an algorithm that calculates nucleotide-level distances directly from cgMLST allelic profiles, providing finer resolution than allele-count distances by leveraging within-allele nucleotide variation. The cache architecture stores alignment statistics, enabling distance calculation modes without computation and supporting both dataset-specific and schema-complete cache generation. This design enables incremental surveillance analysis, with performance benefits as laboratories accumulate alignment data. cgDist functions as a precision 'zoom lens' for the investigation of clusters identified through initial cgMLST screening. Rather than restructuring population relationships, this targeted approach concentrates enhanced resolution where it is most informative. The algorithm ensures that cgDist distances are greater than or equal to corresponding cgMLST distances, preserving epidemiological interpretability while adding genetic discrimination. By increasing resolution within identified clusters, cgDist may also support outbreak investigation, a potential application that remains to be evaluated on outbreak-derived data.

Algorithms↗

Theseus: fast and optimal affine-gap sequence-to-graph alignment.

MOTIVATION: Sequence-to-graph alignment is a central problem in bioinformatics, with applications in multiple sequence alignment (MSA) and pangenome analysis, among others. However, current algorithms for optimal affine-gap alignment impose high memory and computational requirements, limiting their scalability to aligning long sequences to complex graphs. Practical solutions partially address this problem using heuristic strategies that ultimately trade off optimality for speed. RESULTS: This work presents Theseus, a novel, fast, and optimal affine-gap sequence-to-graph alignment algorithm. Theseus leverages similarities between genomic sequences to accelerate the alignment computation and reduces the overall memory requirements without compromising optimality. To that end, Theseus processes only a subset of the dynamic programming cells, using a sparse-data strategy that enables efficient sequence-to-graph alignment. Moreover, our algorithm supports optimal affine-gap alignment on arbitrary directed graphs, including those with cycles. We evaluate Theseus on two key problems: MSA and pangenome read mapping. For MSA, we compare it against SPOA, abPOA, and POASTA. Theseus is 1.6× to 17.6× faster than POASTA, and 7.3× faster, on average, than SPOA, both optimal aligners. Compared with abPOA, Theseus ensures optimality and scales to the largest problems. For pangenome read mapping, we benchmark Theseus against the alignment stage of the mapping tool vg map, along with the alignment kernels of SPOA, abPOA, and POASTA. Theseus outperforms the other methods, showing a 1.9× to 16.9× speedup on short reads. Moreover, Theseus is 1.5× to 36.3× faster than vg when aligning against synthetic cyclic graphs. AVAILABILITY AND IMPLEMENTATION: Theseus code and documentation are publicly available at https://github.com/albertjimenezbl/theseus-lib.

Algorithms↗