Publications and source records attributed to S Lampotang.

13 recordsLinked to original sources

Magnetron-based inline microwave fluid warmer.

OBJECTIVE: To develop an in-line microwave fluid warming system that eliminates the difficulties of uneven heating that are characteristic of batch-mode microwave fluid warmers. METHODS: Using a commercial microwave oven, we developed a method for warming fluid as it flowed through tubing along a defined path in the oven's cavity. Algorithms utilizing either proportional or adaptive control were used to control microwave heating cycles by varying the heating pulse-width during 3-second epochs. Methods of fluid entry and exit were devised to minimize microwave leakage. Heating performance was tested using icewater at multiple flow rates from 18 mL/min to 105 mL/min. RESULTS: In all warming tests, the system achieved temperature control without exceeding the maximum temperature allowable based on American Association of Blood Banks requirements. The adaptive control maintained the set temperature, with peak-to-peak oscillations of 2 degrees C or less. Microwave leakage was below the commercially required limit for home microwave appliances. CONCLUSIONS: The combination of proportional and adaptive control is successful in controlling the permanent magnet magnetron microwave energy to heat the icewater tested. The in-line microwave warmer has the potential to become a successful medical fluid warmer. More study is needed to determine the stability of the control system under clinical conditions, and to evaluate its utility for warming blood.

Blood Transfusion

[Anesthesia simulators and training devices].

Simulators and training devices are used extensively by educators in 'high-tech' occupations, especially those requiring an understanding of complex systems and co-ordinated psychomotor skills. Because of advances in computer technology, anaesthetised patients can now be realistically simulated. This paper describes several training devices and a simulator currently being employed in the training of anaesthesia personnel at the University of Florida. This Gainesville Anesthesia Simulator (GAS) comprises a patient mannequin, anaesthesia gas machine, and a full set of normally operating monitoring instruments. The patient can spontaneously breathe, has audible heart and breath sounds, and palpable pulses. The mannequin contains a sophisticated lung model that consumes and eliminates gas according to physiological principles. Interconnected computers controlling the physical signs of the mannequin enable the presentation of a multitude of clinical signs. In addition, the anaesthesia machine, which is functionally intact, has hidden fault activators to challenge the user to correct equipment malfunctions. Concealed sensors monitor the users' actions and responses. A robust data acquisition and control system and a user-friendly scripting language for programming simulation scenarios are key features of GAS and make this system applicable for the training of both the beginning resident and the experienced practitioner. GAS enhances clinical education in anaesthesia by providing a non-threatening environment that fosters learning by doing. Exercises with the simulator are supported by sessions on a number of training devices. These present theoretical and practical interactive courses on the anaesthesia machine and on monitors. An extensive system, for example, introduces the student to the physics and clinical application of transoesophageal echocardiography.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesiology

Simulation of ventilatory-induced stone movement and its effect on stone fracture during extracorporeal shock wave lithotripsy.

Because ventilation influences renal movement, we investigated the effect of stone motion on the efficiency of extracorporeal shock-wave lithotripsy (ESWL). Comparisons of the rates of fragmentation of an experimental model of renal calculi were made between simulated high-frequency jet ventilation at 100 breaths/min. with four-mm. stone movement as measured from the fluoroscope screen, conventional mechanical ventilation at 10 breaths/min. with 32-mm. stone movement as measured from the fluoroscope screen, and a static control. Fragmentation did not differ significantly between high-frequency jet ventilation and no ventilation (static control), but was significantly greater with high-frequency jet ventilation than with conventional ventilation.

High-Frequency Jet Ventilation

Effects of expiratory flow resistance on inspiratory work of breathing.

To minimize work of breathing, airway pressure should not fluctuate during spontaneous breathing with continuous positive airway pressure (CPAP). However, flow resistance in the inspiratory limb of the breathing circuit and an inadequate continuous gas flow rate result in airway pressure fluctuation and increased work of breathing. Flow resistance of the expiratory pressure/exhalation valve also directly affects the level of airway pressure during spontaneous inhalation with CPAP (the greater the resistance of the valve, the greater the decrease in airway pressure and work of breathing). We compared this effect with three types of expiratory pressure valves: a threshold resistor with low resistance to flow, an inflatable balloon (mushroom) valve with moderate resistance to flow, and a variable-orifice flow resistor with a high resistance to flow. Work increased up to threefold with the balloon valve and more than tenfold with the flow resistor compared with the threshold resistor. To apply CPAP, expiratory pressure valves with low resistance to flow should be used to minimize fluctuations in airway pressure and, thus, in the work of spontaneous breathing.

Humans

Capnography and the Bain circuit II: Validation of a computer model.

Validation of a computer model is described. The behavior of this model is compared both with mechanical ventilation of a test lung in a laboratory setup that uses a washout method and with manual ventilation. A comparison is also made with results obtained from a volunteer breathing spontaneously through a Bain circuit and with results published in the literature. This computer model is a multisegment representation of the Bain circuit and connecting tubing. For each segment, gas pressure, gas volume flow, and partial pressure of carbon dioxide are calculated for any number of breaths wanted. As a result, the time course of these variables can be generated for any location or, conversely, the carbon dioxide distribution in the system can be calculated for any time instant. A test lung, the human lungs, the ventilator bellows, and the reservoir bag are each represented by a single segment. The shapes of pressure and flow curves and of the capnograms taken at different locations in the Bain tubing are in good agreement. The washout study permits measurement of the time delay between the first expiration and the arrival of carbon dioxide at a particular location. The carbon dioxide level in the test lung decreases during inspiration and is stable during expiration. Quantitative agreement between model and experimental transport delays and carbon dioxide levels is such that the differences can be explained by the inaccuracy of the measurement. This is concluded from a sensitivity analysis. The study of the effect of segment size shows an almost optimal agreement between model behavior and experimental results for a 36-segment model. Execution of a thorough validation is imperative before such models can be used for clinical management and decision making or for teaching.

Airway Resistance

Flow resistance of expiratory positive-pressure valve systems.

The flow-resistive characteristics of a variety of commercially available expiratory positive-pressure valve systems used to provide continuous positive airway pressure (CPAP) and positive end-expiratory pressure were evaluated. One flow-resistor and seven threshold-resistor expiratory pressure valve systems were set at 5, 10, 15, 20, and 25 cm H2O of expiratory pressure, and sinusoidal exhaled flows peaking at 50,100, and 200 L/min were directed through each valve at each level of expiratory pressure. The Siemens flow-resistor valve demonstrated the greatest deviation in pressure above set CPAP levels at peak flow rates of 100 and 200 L/min, which suggests high resistance to exhaled flow. The Vital Signs threshold-resistor valve demonstrated the least deviation in pressure from set CPAP levels at all rates of exhaled flow, which suggests low flow resistance. The Emerson and IMV Bird threshold-resistor systems resisted flow less than the BEAR-2 and the Puritan-Bennett MA-2 and 7200 inflatable-balloon threshold-resistor-like valve systems. These data suggest that threshold resistors may be classified as low-resistance or high-resistance types. Using only low-resistance threshold resistors for CPAP may minimize the incidence of barotrauma and other deleterious effects related to airway pressure.

Airway Resistance

Capnography and the Bain circuit I: A computer model.

The Mapleson D anesthesia breathing system has no valves and allows rebreathing of carbon dioxide. Its coaxial version is known as the Bain system. The interpretation of capnograms obtained during its use requires an understanding of the interrelationships of patient and system variables. Toward that end, a systematic description of mechanical ventilation with the Bain circuit was undertaken based on the physical laws of gas transport. The mathematical formulation of the model contains the relations between pressure, flow, and volume in the tube, alveolar space, and ventilator. The flows, calculated from these relations, are used to determine the CO2 concentrations in the different parts of the model. Two sets of data are used--patient and system. The patient data, used to solve the equations numerically, are lung-thorax compliance, CO2 inflow into alveolar space (CO2 production), functional residual capacity, dead space volume, airway resistance, and respiratory quotient. The ventilation system data comprise the dimensions and volumes of the Bain circuit, ventilator, connectors, and tubes; spill valve pressure; resistances to flow in the individual tube parts; ventilator settings; and fresh-gas flow rates. After incorporation of a volunteer's respiratory variables into the model, capnograms obtained from the model compared well with those obtained from the volunteer. The structure of the model is such that it permits easy introduction or changes of patient and system variables to obtain individual results or model specific circumstances. This flexibility makes it a useful tool for understanding the properties of the Bain circuit under a variety of clinical circumstances. The results may be displayed in a number of different ways.

Anesthesia, General

Factors influencing capnography in the Bain circuit.

The Bain circuit provides continuous fresh gas flow near the airway. The potential mixing of this fresh gas with expired gas may prevent reliable analysis of expired gas. We therefore investigated the interaction of sampling site, fresh gas flow rate, expiratory flow rate, and sampling flow rate on expiratory capnography. Sampling near the fresh gas outlet yielded inaccurate results under several of these conditions. The magnitude of the error was related to the fresh gas and expiratory flow rates. A reliable sampling region near the endotracheal tube was identified.

Anesthesiology