PubMed Health⌕ Search

Biomedical subjects

S Möhlenkamp

Publications and source records attributed to S Möhlenkamp.

24 records · Page 2Linked to original sources

Usefulness of motion patterns indentified by tissue Doppler echocardiography for diagnosing various cardiac masses, particularly valvular vegetations.

This study sought to test whether anomalous cardiac and aortic structures can be differentiated from native tissue and artifacts by physical properties of tissue motion using transesophageal tissue Doppler echocardiography (TDE). TDE was employed in 85 consecutive patients after anomalous structures had been detected by conventional transesophageal echocardiography (TEE). The control group consisted of 40 randomized patients. Certainty of diagnosis was divided into 4 categories, and TDE signals were related to particular anomalous structures by a blinded second observer. A mechanical model of a beating ventricle was constructed and suspended in a water bath. Synthetic material was utilized to simulate anomalous intracavitary structures with varying shape, consistency, and attachment. Incoherent motion was present in endocarditic vegetations, freely oscillating thrombi, fourth-degree aortic plaques, Chiari network, valvular prolapse, tumors, and in normal valve leaflets and papillary muscles. Within 15 seconds vegetations could be detected in 17 patients (68%) using TDE versus 5 patients (20%) using only conventional imaging. Coherent motion with a phase difference occurred due to damped oscillation. This phenomenon occurred in 5 patients with thrombi of the left atrial appendage (100%), in 3 ventricular clots (75%), and in 2 hypernephroma in the right atrium (100%). Rapid identification of clots could be achieved in 15 patients (71%) versus 12 patients (57%). Concordant motion was shown in third-degree aortic plaques, postrheumatic valvular lesions, and aortic intramural hematomas, but diagnostic benefit could not be demonstrated. In 41 patients (48%) histopathologic and intraoperative results confirmed echocardiographic findings. Motion patterns could be reproduced independently of the heart rate by model experiments. This study demonstrates that TDE expedites the detection of vegetations in infective endocarditis. Diagnostic certainty can be increased as well for thrombus formations.

Adult↗

Minimally invasive evaluation of coronary stents with electron beam computed tomography: In vivo and in vitro experience.

We sought to describe the value of electron beam computed tomography (EBCT) to detect stent restenoses at follow-up and to identify characteristic EBCT features of coronary stents. Six coronary stents (GRII, Jostent, NIR, PS, Micro, Wiktor) were scanned in vitro (10 1. 5-mm-thick slices, 15-cm FoV, 100-ms AT) before and after inflation with 3.0-, 3.5-, and 4.0-mm balloons to study intensity values and different stent dimensions in comparison to caliper measurements. In 44 patients (60 +/- 10 years, 4 females) we prospectively compared EBCT findings [eight 8-mm-thick slices in the flow mode, 26-cm field of view (FoV), 50 ms acquisition time (AT)] with 6-month angiographic outcome after placement of 86 stents in 49 vessels. For the detection of significant angiographic luminal narrowing (>/=75%) that occurred in 17/49 vessels (35%), we found a sensitivity of 65%, a specificity of 84%, and a positive and negative predictive value of 69% and 82%, respectively. The in vitro data show significant differences in image intensity between the stents and a significant gradual decrease in image intensity with increasing stent diameters. The mean differences between EBCT and caliper measurements for the length and diameter were 0.17 +/- 0.18 mm and -0.32 +/- 0.25mm, respectively. EBCT is currently the only noninvasive technique that allows the assessment of stent dimensions and stent geometry, which may prove useful in patients when intravascular ultrasound cannot be performed. Contrast-enhanced EBCT is a promising tool for minimally invasive stent patency evaluation at follow-up, especially in patients that are unable to exercise. Cathet. Cardiovasc. Intervent. 48:39-47, 1999.

Coronary Angiography↗

Improved coronary risk assessment with electron beam computed tomography in an asymptomatic female with familial hypercholesterolemia.

An asymptomatic 36-year-old woman had high cholesterol levels due to heterozygous familial hypercholesterolemia (FHC) and a family history of coronary artery disease (CAD) but no other risk factors. Exercise testing showed no signs of ischemia. Conventional drug therapy did not lower lipid levels adequately. However, low-density lipoprotein (LDL) apheresis, which effectively reduces cholesterol levels in patients with heterozygous FHC, was not indicated, according to current guidelines. Electron beam computed tomography demonstrated exceptionally high amounts of coronary calcium for the patient's age and sex. A subsequent coronary angiogram revealed advanced CAD, which justified the initiation of LDL apheresis to reduce her cholesterol levels. In patients with heterozygous FHC refractory to conventional lipid-lowering therapy, the presence of coronary calcium in the highest percentiles for age and sex (i.e., > 75th percentile) may warrant aggressive clinical management to improve prognosis, even if no symptoms or signs of ischemia are present.

Adult↗

[Improved structure identification with tissue Doppler echocardiography].

Tissue Doppler echocardiography (TDE) has been shown to be of particular value in patients with impaired myocardial function. Recently, the technique was successfully employed to localize the ventricular insertion of accessory atrioventricular pathways. The identification of abnormal cardiac structures is coming up now as a new field of clinical interest. The purpose of this study was to differentiate anomalous cardiac and aortic from native structures by physical properties of tissue motion using transesophageal TDE. Characteristic motion patterns of anomalous structures have not been described in detail and tissue Doppler findings have not been associated with clinical features up to now. Forty consecutive patients were included after anomalous cardiac or vascular structures had been detected by conventional transesophageal echocardiography (TEE). A control group consisted of 20 subjects. Rapidity of diagnosis in anomalous structures was divided into 3 categories, and TDE signals were related to particular pathology by a blinded, 2nd observer. Three different motion patterns could be defined: incoherent motion due to free oscillation of an anomalous structure which is independent of the surrounding tissue (Figure 1b); coherent motion with a phase difference meaning that motion depends on the motion of the surrounding tissue but is out of phase (Figure 2); concordant motion showing no difference in direction, velocity, or phase of motion compared with the surrounding tissue. Incoherent motion was present in endocarditic vegetations, 4th degree aortic plaques, Chiari network, valvular prolapse, intracavitary tumors, and freely oscillating thrombi as well as in normal valve leaflets and papillary muscles. Especially if endocarditic vegetations are present its incoherent motion facilitates to recognize these small structures. The colorcode of this motion pattern demarcates the vegetation reliably from the surrounding tissue (Figure 1b). Within 15 seconds vegetations could be detected in 9 (82%) vs 2 (18%) patients employing only conventional imaging. Using conventional echocardiographic approaches detection of vegetations is frequently hindered by their small size and minor echo intensity (Figure 1a). In contrast, size and echo intensity do not affect the tissue Doppler signal. Normal papillary muscles and distal portions of the mitral and tricuspid valves were demonstrated to regularly meet the criterion of incoherent tissue motion in the control group. In part, this was also observed with respect to the aortic and pulmonary valves. In valvular tissue incoherent motion was caused by passive floating, whereas papillary muscles show an active inverse motion for short time intervals. Nevertheless, physiologic incoherent motion did not lead to any false differential diagnosis. The phase difference of coherent motion results from damped oscillation. This phenomenon was visualized by tissue Doppler M-mode in 5 thrombi of the left atrial appendage (LAA) (100%) and in 1 ventricular thrombus (50% of all clots). Concordant motion was shown in 3rd degree aortic plaques and postrheumatic and calcified vegetations. These structures were found to be completely embedded or closely attached, so that their passive motion corresponded to the motion of the surrounding regular tissue. Detection and assessment of anomalous structures are based on their motion patterns which can be synchronous or asynchronous in comparison with the surrounding tissue. Another goal of this investigation was to test if the sensitivity of TEE to spontaneous echo contrast can be improved using TDE. In 21 patients presenting with left atrial dilation (left atrial diameter > 44 mm) due to mitral stenosis (n = 8), mitral regurge (n = 5), arterial hypertension (n = 5) and multiple valvular disease (n = 3) fundamental multiplane TEE and transesophageal TDE were performed with standardized gain setting. The control group consisted of 20 randomized individuals with normal left

Aorta, Thoracic↗

[New imaging methods for visualizing coronary arteries].

Techniques in the field of coronary artery imaging can be divided into two groups: invasive and non-invasive methods. Apart from the conventional coronary artery angiography, invasive methods include intracoronary ultrasound, intracoronary angioscopy, and optical coherence tomography. Non-invasive methods include magnetic resonance tomography, synchrotron-coronary angiography, and electron beam computed tomography. In the late 1980s, intracoronary ultrasound has come into clinical practice. It offers a real-time, cross-sectional image of the coronary artery in high resolution. Coronary arteries enlarge in the presence of atherosclerotic plaque formation in order to compensate for luminal narrowing caused by plaque formation (remodeling). With coronary angiography, the plaque formation cannot be detected until a lumen reduction of about 40-45%. With intravascular ultrasound, the early stages of atherosclerosis can clearly be demonstrated. In combination with the intracoronary Doppler technique, syndrome X can be differentiated. Another important role of intracoronary ultrasound in the diagnosis of coronary artery disease is to guide coronary interventions and to assess the result of coronary interventions especially to evaluate the result of stent implantation. Due to the clinical use of intracoronary ultrasound and the guidance of high pressure stent implantation, the incidence of acute stent thrombosis has decreased to about 1%. Coronary angioscopy portrays the surface of the vessel lumen. It is helpful to identify the mural thrombus especially to differentiate fresh and chronic thrombus formation. Magnetic resonance tomography is able to image the coronary arterial contour of the proximal segment. With today's gating technique, it is possible to portray the whole coronary tree and avoid disturbances resulting from the heart beat and respiration. Electron beam computed tomography is a very promising technique in screening for coronary artery disease. It is a very sensitive method to identify coronary calcification and, thus, to detect atherosclerotic plaque. Studies have shown that the presence of calcification almost invariably indicates the presence of coronary artery disease and that the absence of calcification can nearly rule out significant coronary artery disease. Moreover, a close correlation exists between the amount of calcification and the severity of coronary artery disease. Additionally, in combination with contrast injection, coronary artery perfusion can be evaluated. This is important to assess the conductance of coronary stent and bypass graft.

Coronary Artery Disease↗

Stress echocardiography: new techniques.

Stress echocardiography is frequently used to evaluate coronary artery disease, and also in quantitative assessment of right and left ventricular function or cardiac valve integrity in patients with cardiomyopathy or during chemotherapy. Various new ultrasound techniques in stress echocardiography are now playing a significant role in this important area of cardiological diagnostics. New methods of echocardiographic signal processing have been developed to provide more quantitative and reproducible information on cardiac function during stress. The most important are: (1) raw data analysis techniques for endocardial border detection (acoustic quantification, CK = colour kinesis), (2) tissue Doppler imaging for myocardial velocity analysis and (3) transpulmonary contrast agents (Albunex, Laevovist, BY 963) for improving endocardial border delineation and for future analysis of myocardial perfusion. Like all new techniques, they must first be subjected to comprehensive scientific assessment, and appropriate training should be given, taking into account physical and physiological limits. These limits will constantly be redefined as echocardiographic techniques continue to change presenting new challenges for the further development of ultrasound technology. In this review, the improved new techniques will be discussed in detail.

Animals↗