Electrophoretic mobilities of cationic analytes in non-aqueous methanol, acetonitrile and their mixtures. Influence of ionic strength and ion-pair formation.

The mobilities of cationic analytes in organic solvents and water are compared, and the reasons for differences in the mobilities are discussed in detail. Actual mobilities (at background electrolyte concentration 10 mmol/l) of anilinium ions were determined by capillary zone electrophoresis in water, methanol, acetonitrile and mixtures of methanol and acetonitrile (in volume ratios 1:1, 1:3 and 3:1). The actual mobilities correlated with the viscosity of the organic solvent: the products of actual mobility and viscosity were constant within 7%. However, these products were significantly larger in water. Larger products of mobility and viscosity in water were also found for unsubstituted anilinium when the absolute mobility (at zero ionic strength) was taken into consideration. Thus, ion-solvent interactions must be responsible for the seemingly high mobility in water compared with that in organic solvents. This finding can be explained by the effect of the ion on the water structure. Based on equilibrium constant for ion-pair formation given in the literature, about 20% of the main background electrolyte constituent (tetrapropylammonium perchlorate) is associated at 10 mmol/l concentration in acetonitrile. Comparison of the plot of the measured mobilities of the analytes vs. the square root of the corrected ionic strength of the background electrolyte in acetonitrile with the prediction based on the Debye-Hückel-Onsager theory showed the measured mobilities deviate negatively from the theoretical line. This is apparently due to ion pairing, which takes place for the analytes as well.

Acetonitriles↗

Extremely high electric field strengths in non-aqueous capillary electrophoresis.

The influence of high electric field strength on the separation of basic analytes in non-aqueous alcohol background electrolyte (BGE) solutions was investigated. Increasing the separation voltage in capillary electrophoresis (CE) may be advantageous if the conductivity of the BGE solution is low enough to allow fast separations without excessive Joule heating or band broadening. The voltage range tested was 20-60 kV with methanol and ethanol, and 25-60 kV with propanol and butanol as solvent for BGE. The resulting electric field strengths ranged from 660 V cm(-1) to 2000 V cm(-1). Experiments were made with a special laboratory constructed CE instrument. The separation efficiency vs. voltage curve was found to vary with the alcohol BGE solution. The increase in voltage decreased the separation efficiency in the case of methanol BGE solution, but with the other BGEs a clear efficiency maximum was obtained above 30 kV. The highest separation efficiencies were achieved with propanol BGE solution, where the efficiency maximum was reached at 45 kV. However, reasonable efficiency was achieved even at 60 kV. The extent of Joule heating was determined by calculating the temperature inside the capillary and the observed plate heights were interpreted in terms of the Van Deemter equation. The decrease in the separation efficiency with higher voltage was attributed mainly to Joule heating in the case of methanol and ethanol BGE solution and to the analyte adsorption on the capillary wall with propanol and butanol BGE solutions.

Electricity↗

Capillary zone electrophoresis of basic analytes in methanol as non-aqueous solvent mobility and ionisation constant.

The electrophoretically relevant properties of monoacidic 21 bases (including common drugs) containing aliphatic or aromatic amino groups were determined in methanol as solvent. These properties are the actual mobilities (that of the fully ionised weak bases), and their pKa values. Actual mobilities were measured in acidic methanolic solutions containing perchloric acid. The ionisation constants of the amines were derived from the dependence of the ionic mobilities on the pH of the background electrolyte solution. The pH scale in methanol was established from acids with known conventional pK*a values in this solvent used as buffers, avoiding thus further adjustment with a pH sensitive electrode that might bias the scale. Actual mobilities in methanol were found larger than in water, and do not correlate well with the solvent's viscosity. The pK*a values of the cation acids, HB-, the corresponding form of the base, B, are higher in methanol, whereas a less pronounced shift was found than for neutral acids of type HA. The mean increase (compared to pure aqueous solution) for aliphatic ammonium type analytes is 1.8, for substituted anilinium 1.1, and for aromatic ammonium from pyridinium type 0.5 units. The interpretation of this shift was undertaken with the concept of the medium effect on the particles involved in the acid-base equilibrium: the proton, the molecular base, B, and the cation HB+.

Electrophoresis, Capillary↗

Resolution in capillary electrophoresis with nonaqueous methanol as solvent: theoretical prediction and experimental confirmation.

The resolution of the analytes was predicted from their known pKa* values and actual mobilities in nonaqueous methanolic solutions according to theory taking longitudinal diffusion as the only cause for peak dispersion. This leads to an equation of the resolution as a function of the pH*, as both selectivity and efficiency are dependent on the pH of the buffer. The experimentally obtained resolution values were in acceptable agreement with the predicted theoretical ones in most cases. This was demonstrated for substituted benzoic acids as analytes. The pKa* values needed for the calculation of the resolution were derived from the pH* dependence of the effective mobility. The pH* scale in methanol was based on conventional pKa* values of acetic acid and chloroacetic acid taken from the literature.

Benzoates↗

Novel dynamic polymer coating for capillary electrophoresis in nonaqueous methanolic background electrolytes.

Coated capillaries can be advantageous in many capillary electrophoretic applications where nonaqueous background electrolytes are used. In the present work, a new dynamic polymer coating (poly(glycidylmethacrylate-co-N-vinylpyrrolidone)) for methanol-based background electrolytes is introduced. The magnitude and stability of electroosmotic flow was investigated with coated capillaries at pH* values of 3, 7.8, and 10.4 in methanol. At pH* 7.8 and 10.4 the electroosmotic flow was negligible and repeatable. On the other hand, at pH* 3 a weak, unstable electroosmotic flow was observed, due to a change in the conformation of the polymer under acidic conditions. The dynamically coated capillaries were successfully applied to the separations of cationic drugs, phenols, and benzoic acids. The synthesis and characterization of the polymer are described in detail.

Alprenolol↗

Non-aqueous capillary electrophoresis.

The benefits of non-aqueous capillary electrophoresis have been described in a number of recent publications. The wide selection of organic solvents, with their very different physicochemical properties, broadens our scope to manipulate separation selectivity. The lower currents present in non-aqueous solvents allow the use of high electric field strengths and wide bore capillaries, the latter in turn allowing larger sample load. In many cases detection sensitivity can also be enhanced. The potential of non-aqueous capillary electrophoresis is discussed throughout the paper, and the feasibility of capillary electrophoresis under non-aqueous media is demonstrated with reference to several applications.

Electrophoresis, Capillary↗

Compensation of the siphoning effect in nonaqueous capillary electrophoresis by vial lifting.

Increasing the sample load in nonaqueous capillary electrophoresis through the use of wide-bore capillaries is a good way to scale up analytical separations to semipreparative level. However, obtaining high efficiency requires the use of special instrumentation to eliminate siphoning. When wide-bore capillaries are employed, relatively large solvent volumes are transported from inlet to outlet vial, and due to the difference in liquid levels a siphoning flow from outlet to inlet is established. Siphoning induces a deviation from the plug-like flow profile and adversely affects the separation efficiency. In this study the use of wide-bore capillaries in nonaqueous capillary electrophoresis was examined with compensation for siphoning by lifting of the inlet vial. The inlet vial is raised at a speed appropriate for maintaining equal levels of liquid in the inlet and outlet vials. The optimal lift rate was determined empirically from a series of runs in which the lift rate was varied. As well, a simple theoretical model was devised for the calculation of lift rates. The model was successfully applied for the 200 microm and 320 microm ID capillaries but for the 530 microm ID capillary the predicted optimal lift rate was too low. Evidently this was because the theory was unable to account for the effect of siphoning on the migration times. Three model compounds, bumetanide, furosemide and ethacrynic acid, were separated using an acetonitrile-ethanol mixture (50:50, v/v) with potassium acetate (1 mM) or ammonium acetate (5 mM) as electrolyte. Good separation of bumetadine and ethacrynic acid was obtained even with a 530 microm ID capillary when the lift rate was carefully optimized. Without elimination of siphoning the peaks would not have been detectable. The viscosities and electrical conductivities of the electrolyte solution measured at different temperatures showed that viscosity as well as conductivity decreased with increasing temperature. The temperature dependence of the conductivity was used to estimate the temperature inside the CE capillary.

Electric Conductivity↗

Modified liquid junction interface for nonaqueous capillary electrophoresis-mass spectrometry.

Electrospray ionization (ESI) is the most widely used ionization method in on-line coupling of capillary electrophoresis-mass spectrometry (CE-MS). The conventional coaxial sheath flow electrospray interface is currently being replaced by the more sensitive nanoelectrospray technique. The usual limitation of nanoelectrospray CE-MS interface has been its short lifetime caused by deterioration of the metal coating on the CE capillary terminus. This article describes an easy way to construct a more durable and sensitive nanospray interface for nonaqueous CE-MS. In this approach a very thin glass spray capillary (ca. 30 microm outer diameter) is partly inserted inside the CE capillary, the junction being surrounded by the electrolyte medium, which is in contact with the platinum electrode. The interface was tested with five pharmaceuticals: methadone, pentazocine, levorphanol, dihydrocodeine, and morphine. Detection limits ranged from 12 to 540 fmol. Separation efficiency and reproducibility were also studied. The CE current was found to be stable and the migration times were highly reproducible. All the CE separations were carried out in a nonaqueous background electrolyte solution.

Codeine↗

Effect of electrolyte and solvent composition on capillary electrophoretic separation of some pharmaceuticals in non-aqueous media.

Non-aqueous capillary electrophoresis was used to study the separation selectivity of positively charged drug substances and negatively charged diuretics. Study was made of the effects of organic solvent composition and the background electrolyte on the separation. The separation selectivity could be altered considerably by varying the methanol/acetonitrile composition. In addition, the migration order and the resolution of the pharmaceuticals could be altered merely by changing the electrolyte cation or the anion. The electrolytes tested were alkali metal acetates, ammonium acetate, ammonium chloride and ammonium bromide. As with aqueous background electrolyte solutions, the electroosmotic flow was decreased with increasing size of the alkali metal cation of the electrolyte in methanol/acetonitrile 50:50 (v/v).

Acetates↗

Alcohols and wide-bore capillaries in nonaqueous capillary electrophoresis.

The feasibility of using C1-C5 alcohols as electrolyte solutions in nonaqueous capillary zone electrophoresis was investigated. The separation of basic narcotic analgesics and acidic diuretics was modified by changing the alcohol in an electrolyte solution containing alcohol-acetonitrile-acetic acid (50:49:1, v/v) and 20 mM ammonium acetate while other experimental conditions were kept constant. The alcohols studied were methanol, ethanol, 1-propanol, 2-propanol, 1-butanol, 2-butanol, and 1-pentanol. The results indicate that even longer-chain alcohols can be used in nonaqueous capillary zone electrophoresis and, because of the lower currents they allow, they are especially advantageous in wider capillaries. Basic analytes were separated in 200 microm and 320 microm ID capillaries with 1-butanol-acetonitrile-acetic acid (50:49:1, v/v) containing 20 mM ammonium acetate as electrolyte solution. Problems related to the use of wide-bore capillaries are discussed.

Acetates↗