PubMed Health⌕ Search

Biomedical subjects

S Steinmetz

Publications and source records attributed to S Steinmetz.

4 recordsLinked to original sources

Left ventricular myocardial mass determination by contrast enhanced colour Doppler compared with magnetic resonance imaging.

OBJECTIVE: To assess the feasibility of using contrast enhanced colour Doppler echocardiography to determine left ventricular (LV) mass and to compare its accuracy with LV mass obtained by magnetic resonance imaging (MRI). METHODS: Images were acquired in the short axis plane of the heart, derived from coronal and sagittal scout views and double oblique angulation. The LV mass was calculated by two methods: Simpson's rule and the area-length method. Levovist (Schering AG, Berlin, Germany) 2.5 g was given by slow intravenous bolus or infusion over about 45 seconds for contrast imaging. LV images were captured in the apical two chamber, four chamber, and three chamber views. Each contrast harmonic colour Doppler image was converted to a cavity-only image by simple image mathematics. RESULTS: 27 (77.1%) of the patients (mean (SD) age 66.2 (8.9) years) were men. There was a mean (SD) interval of 6.6 (8.6) days (range 0-27 days) between echocardiography and MRI. The mean (SD) LV mass determined by MRI Simpson's rule method was 171.0 (52.4) g (range 105.1-318.7 g). The mean LV mass (SD) determined by the echocardiographic Simpson's rule method was 178.2 (47.0) g (range 112.6-307.6 g). The mean (SD) MRI area-length LV mass was 187.3 (64.5) g (range 109.0-393.6 g). The linear regression correlation between LV mass determined by MRI Simpson's and echocardiographic Simpson's methods was excellent (y = 1.022x, R2 = 0.986) with a mean (SD) difference of 7.20 (20.9) g. The linear regression correlation between the MRI area-length LV mass and MRI Simpson's LV mass was excellent (y = 1.101x, R2 = 0.989) with a mean (SD) difference of 16.3 (22.3) g. CONCLUSIONS: LV mass may be obtained reliably by contrast enhanced colour Doppler and two dimensional echocardiography. The contrast Doppler method accurately determines LV mass with excellent agreement with the MRI technique.

Aged↗

Methods for quantifying ultrasound backscatter and two-dimensional video intensity: implications for contrast-enhanced sonography.

Quantification of acoustic backscatter energy is believed to be useful for assessing "tissue character" and for quantifying the regional concentration of echo contrast. Measurement of ultrasonic video intensity has been the traditional means of quantifying backscatter energy, with "integrated backscatter" considered the gold standard. The purpose of this work is to review the commonly used methods for quantifying ultrasonic backscatter and to describe the difference between detected backscatter energy and the intrinsic tissue backscatter coefficient. Many of the quantification pitfalls that can lead to erroneous conclusions will also be discussed. A set of eight rubber phantoms with backscatter coefficient from -6 dB to +15 dB relative to liver were imaged at 2.5, 3.5, and 5.0 MHz. Methods for calculating the acoustic backscatter intensity from calibrated video intensity measurements and for calculating the tissue backscatter coefficient are described and tested using equipment from two different manufacturers. A commercially available automatic "acoustic densitometry" system with on-board quantitative integrated backscatter is also evaluated. Ultrasound attenuation and ultrasound system factors were found to strongly influence the detected backscatter intensity using either calibrated video intensity or on-board integrated backscatter. Special system transfer functions and attenuation correction were found to be useful in converting video intensity and integrated backscatter to a measure of the intrinsic tissue backscatter coefficient. With these correction factors, the correlation between the measured tissue backscatter coefficient and the phantom backscatter coefficient was excellent (r = 0.99, intercept 0.0, regression slope essentially 1.0) at all three imaging frequencies with traditional video intensity or on-board integrated backscatter. Uncalibrated video intensity and on-board integrated backscatter have limitations when used in isolation for tissue characterization. Rigorous attention to the imaging parameters and the use of calibration functions are necessary before video intensity measurement or integrated backscatter can be used reliably to measure the tissue backscatter coefficient.

Acoustics↗

Harmonic imaging with Levovist.

Our purpose was to test the hypothesis that second harmonic imaging preferentially detects backscatter from microbubbles compared with tissue structural components. A prototype second harmonic scanner was used to image a flow channel in a tissue-mimicking rubber phantom (liver density). Video time-intensity curves were calculated from repeated bolus injections of microbubble echocardiographic contrast material under the same fluid dynamic conditions but with three different imaging modes: (1) fundamental imaging at 2.5 MHz (transmit and receive at 2.5 MHz), (2) fun damental imaging at 5.0 MHz (transmit and receive at 5.0 MHz), and (3) second harmonic imaging (transmit at 2.5 MHz and receive at 5.0 MHz). Each video time-intensity curve was calibrated-such that quantitative backscatter intensity was measured relative to the tissue phantom (0 dB). The peak increase in backscatter from the contrast material in the channel relative to the tissue phantom and the intensity in the channel before the contrast effect (the noise floor) was measured along with the area under the calibrated time-intensity curve relative to the phantom. When referenced to the noise floor in the flow channel, all imaging modes produced approximately 25 dB of enhancement. However, when referenced to the tissue phantom, second harmonic imaging produced a 22.3 +/- 1.8 dB peak enhancement, which was greater than either fundamental imaging at 2.5 MHz (15.5 +/- 0.8 dB; p < 0.001) or fundamental imaging at 5.0 MHz (15.3 +/- 1.5 dB; p < 0.001). The area under the time-intensity curves confirmed that harmonic imaging has approximately 7 dB of relative enhancement to the phantom compared with fundamental imaging at either frequency. Second harmonic imaging specifically enhances backscatter from microbubbles compared with a tissue-mimicking phantom. This specificity for microbubbles is due to a decrease in backscatter for the tissue phantom, rather than an increase in backscatter for the microbubbles. These data support the hypothesis that second harmonic imaging may be able to detect microbubbles in the tissue vascular space by preferentially decreasing the backscatter from tissue structural components.

Echocardiography↗