Methods for quantifying ultrasound backscatter and two-dimensional video intensity: implications for contrast-enhanced sonography.

Abstract

Quantification of acoustic backscatter energy is believed to be useful for assessing "tissue character" and for quantifying the regional concentration of echo contrast. Measurement of ultrasonic video intensity has been the traditional means of quantifying backscatter energy, with "integrated backscatter" considered the gold standard. The purpose of this work is to review the commonly used methods for quantifying ultrasonic backscatter and to describe the difference between detected backscatter energy and the intrinsic tissue backscatter coefficient. Many of the quantification pitfalls that can lead to erroneous conclusions will also be discussed. A set of eight rubber phantoms with backscatter coefficient from -6 dB to +15 dB relative to liver were imaged at 2.5, 3.5, and 5.0 MHz. Methods for calculating the acoustic backscatter intensity from calibrated video intensity measurements and for calculating the tissue backscatter coefficient are described and tested using equipment from two different manufacturers. A commercially available automatic "acoustic densitometry" system with on-board quantitative integrated backscatter is also evaluated. Ultrasound attenuation and ultrasound system factors were found to strongly influence the detected backscatter intensity using either calibrated video intensity or on-board integrated backscatter. Special system transfer functions and attenuation correction were found to be useful in converting video intensity and integrated backscatter to a measure of the intrinsic tissue backscatter coefficient. With these correction factors, the correlation between the measured tissue backscatter coefficient and the phantom backscatter coefficient was excellent (r = 0.99, intercept 0.0, regression slope essentially 1.0) at all three imaging frequencies with traditional video intensity or on-board integrated backscatter. Uncalibrated video intensity and on-board integrated backscatter have limitations when used in isolation for tissue characterization. Rigorous attention to the imaging parameters and the use of calibration functions are necessary before video intensity measurement or integrated backscatter can be used reliably to measure the tissue backscatter coefficient.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Q Schwarz, X Chen, S Steinmetz. 1998. Methods for quantifying ultrasound backscatter and two-dimensional video intensity: implications for contrast-enhanced sonography.. https://doi.org/10.1016/s0894-7317(98)70074-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of gamma irradiation on mechanical properties of defatted trabecular bone allografts assessed by speed-of-sound measurement.

New sterilization methods for human bone allografts may lead to alterations in bone mechanical properties, which strongly influence short- and medium-term outcomes. In many sterilization procedures, bone allografts are subjected to gamma irradiation, usually with 25 KGy, after treatment and packaging. We used speed-of-sound (SOS) measurements to evaluate the effects of gamma irradiation on bone. All bone specimens were subjected to the same microbial inactivation procedure. They were then separated into three groups, of which one was treated and not irradiated and two were exposed to 10 and 25 KGy of gamma radiation, respectively. SOS was measured using high- and low-frequency ultrasound beams in each orthogonal direction. SOS and Young modulus were altered significantly in the three groups, compared to native untreated bone. Exposure to 10 or 25 KGy had no noticeable effect on the study variables. The impact of irradiation was small compared to the effects of physical or chemical defatting. Reducing the radiation dose used in everyday practice failed to improve graft mechanical properties in this study.

Acoustics↗

Objective and subjective evaluation of the acoustic comfort in classrooms.

The acoustic comfort of classrooms in a Brazilian public school has been evaluated through interviews with 62 teachers and 464 pupils, measurements of background noise, reverberation time, and sound insulation. Acoustic measurements have revealed the poor acoustic quality of the classrooms. Results have shown that teachers and pupils consider the noise generated and the voice of the teacher in neighboring classrooms as the main sources of annoyance inside the classroom. Acoustic simulations resulted in the suggestion of placement of perforated plywood on the ceiling, for reduction in reverberation time and increase in the acoustic comfort of the classrooms.

Acoustics↗

Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers.

OBJECTIVE: To characterize the ultrasound fields produced by a cohort of transducers from a single manufacturer via hydrophone and Schlieren technology. DESIGN: Descriptive study. SETTING: Measurement laboratory. PARTICIPANTS: Seven same-model ultrasound transducers from a single manufacturer. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Effective radiating area (ERA), total power, spatial average intensity (SAI), beam nonuniformity ratio (BNR), and Schlieren beam widths at 1.0 and 3.3 MHz. RESULTS: Values for ERA (1.0 MHz range, 3.62-4.38 cm(2); 3.3 MHz range, 3.74-4.76 cm(2)), total power (1.0 MHz range, 5.0-5.6 W; 3.3 MHz range, 4.7-5.7 W), SAI (1.0 MHz range, 1.2-1.4 W/cm(2); 3.3 MHz range, 1.0-1.5 W/cm(2)), and BNR (1.0 MHz range, 2.79-5.85; 3.3 MHz range, 2.51-4.56) fell within manufacturer's specifications and U.S. Food and Drug Administration (FDA) regulations. Schlieren analysis showed significantly larger beam widths at 3.3 MHz compared with 1.0 MHz and a large degree of variability in the ultrasound fields generated by the different transducers. There were no significant correlations between beam widths and ERA values. CONCLUSIONS: ERA and total power values in a test cohort exist within a range that met FDA regulations. Individual variability in ERA and total power resulted in 50% variability in SAI. This variability may help explain previous reports of heating differences between transducers.

Acoustics↗