FACS technology used in a new rapid bacterial detection method.

Culture methods for bacterial detection (BacT/ALERT or Pall eBDS) are currently implemented in blood donor screening procedures in many countries. Experience in the first years after implementation of these detection assays showed that although the analytical sensitivity was extremely high (about 1 CFU mL(-1)), the majority of these platelets were still transfused before a positive screening result was attained. Rapid technologies were developed to more effectively prevent transfusion-transmitted bacterial infection. In this study, a new rapid bacterial detection method based on fluorescence-activated cell sorting (FACS) technology was developed. Bacteria were stained with thiazole orange dye for 5 min and measurement was taken immediately after staining. The entire process took only 30 min. Six transfusion-relevant bacteria strains were tested in a spiking study. Without pre-incubation in a special bacteria growth medium, analytical sensitivity ranged between 10(5) CFU mL(-1) (Klebsiella oxytoca and Serratia marcesens) and 10(3) CFU mL(-1) (Escherichia coli). Sensitivity could be improved to 10(1) CFU mL(-1) for all tested bacteria by adding a pre-incubation step (6 h at 37 degrees C). Although preliminary in nature, results of our study suggest that bacterial detection by FACS technology in conjunction with a pre-incubation step offers a sensitive alternative technology to culture methods. Additionally, it provides the benefit of a rapid test time and the opportunity of preventing bacterial transmitted infections more effectively.

Bacteriological Techniques↗

Fluorescence quencher improves SCANSYSTEM for rapid bacterial detection.

BACKGROUND AND OBJECTIVES: The optimized scansystem could detect contaminated platelet products within 24 h. However, the system's sensitivity was reduced by a high fluorescence background even in sterile samples, which led to the necessity of a well-trained staff for confirmation of microscope results. MATERIALS AND METHODS: A new protocol of the optimized scansystem with the addition of a fluorescence quencher was evaluated. Pool platelet concentrates contaminated with five transfusion-relevant bacterial strains were tested in a blind study. RESULTS: In conjunction with new analysis software, the new quenching dye was able to reduce significantly unspecific background fluorescence. Sensitivity was best for Bacillus cereus and Escherichia coli (3 CFU/ml). DISCUSSION: The application of a fluorescence quencher enables automated discrimination of positive and negative test results in 60% of all analysed samples.

Bacteriological Techniques↗