PubMed Health⌕ Search

Biomedical subjects

Samuel G Armato

Publications and source records attributed to Samuel G Armato.

23 records · Page 2Linked to original sources

Automated detection of lung nodules in CT scans: effect of image reconstruction algorithm.

We have investigated the effect of computed tomography (CT) image reconstruction algorithm on the performance of our automated lung nodule detection method. Commercial CT scanners offer a choice of several algorithms for the reconstruction of projection data into transaxial images. Different algorithms produce images with substantially different properties that are apparent not only quantitatively, but also through visual assessment. During some clinical thoracic CT examinations, patient scans are reconstructed with multiple reconstruction algorithms. Thirty-eight such cases were collected to form two databases: one with patient projection data reconstructed with the "standard" reconstruction algorithm and the other with the same patient projection data reconstructed with the "lung" reconstruction algorithm. The automated nodule detection method was applied to both databases. This method is based on gray-level-thresholding techniques to segment the lung regions from each CT section to create a segmented lung volume. Further gray-level-thresholding techniques are applied within the segmented lung volume to identify a set of lung nodule candidates. Rule-based and linear discriminant classifiers are used to differentiate between lung nodule candidates that correspond to actual nodules and those that correspond to non-nodules. The automated method that was applied to both databases was exactly the same, except that the classifiers were calibrated separately for each database. For comparison, the classifier then was trained on one database and tested independently on the other database. When applied to the databases in this manner, the automated method demonstrated overall a similar level of performance, indicating an encouraging degree of robustness.

Adult↗

Automated lung nodule classification following automated nodule detection on CT: a serial approach.

We have evaluated the performance of an automated classifier applied to the task of differentiating malignant and benign lung nodules in low-dose helical computed tomography (CT) scans acquired as part of a lung cancer screening program. The nodules classified in this manner were initially identified by our automated lung nodule detection method, so that the output of automated lung nodule detection was used as input to automated lung nodule classification. This study begins to narrow the distinction between the "detection task" and the "classification task." Automated lung nodule detection is based on two- and three-dimensional analyses of the CT image data. Gray-level-thresholding techniques are used to identify initial lung nodule candidates, for which morphological and gray-level features are computed. A rule-based approach is applied to reduce the number of nodule candidates that correspond to non-nodules, and the features of remaining candidates are merged through linear discriminant analysis to obtain final detection results. Automated lung nodule classification merges the features of the lung nodule candidates identified by the detection algorithm that correspond to actual nodules through another linear discriminant classifier to distinguish between malignant and benign nodules. The automated classification method was applied to the computerized detection results obtained from a database of 393 low-dose thoracic CT scans containing 470 confirmed lung nodules (69 malignant and 401 benign nodules). Receiver operating characteristic (ROC) analysis was used to evaluate the ability of the classifier to differentiate between nodule candidates that correspond to malignant nodules and nodule candidates that correspond to benign lesions. The area under the ROC curve for this classification task attained a value of 0.79 during a leave-one-out evaluation.

Adult↗

Massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography.

In this study, we investigated a pattern-recognition technique based on an artificial neural network (ANN), which is called a massive training artificial neural network (MTANN), for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography (CT) images. The MTANN consists of a modified multilayer ANN, which is capable of operating on image data directly. The MTANN is trained by use of a large number of subregions extracted from input images together with the teacher images containing the distribution for the "likelihood of being a nodule." The output image is obtained by scanning an input image with the MTANN. The distinction between a nodule and a non-nodule is made by use of a score which is defined from the output image of the trained MTANN. In order to eliminate various types of non-nodules, we extended the capability of a single MTANN, and developed a multiple MTANN (Multi-MTANN). The Multi-MTANN consists of plural MTANNs that are arranged in parallel. Each MTANN is trained by using the same nodules, but with a different type of non-nodule. Each MTANN acts as an expert for a specific type of non-nodule, e.g., five different MTANNs were trained to distinguish nodules from various-sized vessels; four other MTANNs were applied to eliminate some other opacities. The outputs of the MTANNs were combined by using the logical AND operation such that each of the trained MTANNs eliminated none of the nodules, but removed the specific type of non-nodule with which the MTANN was trained, and thus removed various types of non-nodules. The Multi-MTANN consisting of nine MTANNs was trained with 10 typical nodules and 10 non-nodules representing each of nine different non-nodule types (90 training non-nodules overall) in a training set. The trained Multi-MTANN was applied to the reduction of false positives reported by our current computerized scheme for lung nodule detection based on a database of 63 low-dose CT scans (1765 sections), which contained 71 confirmed nodules including 66 biopsy-confirmed primary cancers, from a lung cancer screening program. The Multi-MTANN was applied to 58 true positives (nodules from 54 patients) and 1726 false positives (non-nodules) reported by our current scheme in a validation test; these were different from the training set. The results indicated that 83% (1424/1726) of non-nodules were removed with a reduction of one true positive (nodule), i.e., a classification sensitivity of 98.3% (57 of 58 nodules). By using the Multi-MTANN, the false-positive rate of our current scheme was improved from 0.98 to 0.18 false positives per section (from 27.4 to 4.8 per patient) at an overall sensitivity of 80.3% (57/71).

Algorithms↗

Lung cancers missed at low-dose helical CT screening in a general population: comparison of clinical, histopathologic, and imaging findings.

PURPOSE: To compare clinical, histopathologic, and imaging features of lung cancers missed at low-radiation-dose helical computed tomography (CT). MATERIALS AND METHODS: Eighty-three primary lung cancers were found during an annual low-dose CT screening program and confirmed histopathologically at either surgery or biopsy. Thirty-two of these lung cancers were missed on 39 CT scans: on 23 scans owing to detection errors and on 16 owing to interpretation errors. The clinical characteristics, CT features, and histopathologic findings of these missed lung cancers were correlated. RESULTS: All missed cancers were intrapulmonary, and 28 (88%) were stage IA. All 20 detection errors occurred in cases of adenocarcinoma, 17 (85%) of which were well-differentiated tumors and 11 (55%) of which were in nonsmoking women. The mean size of cancers missed owing to detection error, 9.8 mm, was smaller than that of cancers missed owing to interpretation error, 15.9 mm (P <.001). In the detection error group, the percentages of nodules with ground-glass opacity (91%) or judged to be subtle (91%) were greater than those of nodules in the interpretation error group (38% and 25%, respectively) (P <.001). In the detection error group, 83% (19/23) of cancers were overlapped with, obscured by, or similar in appearance to normal structures such as pulmonary vessels. On 14 of the 16 CT scans with which there were interpretation errors, the CT findings mimicked benign disease, and the patients also had underlying lung disease, such as tuberculosis, emphysema, or lung fibrosis. CONCLUSION: The lung cancers missed at low-dose CT screening in this series generally were very subtle and appeared as small faint nodules, overlapping normal structures, or opacities in a complex background of other disease.

Adenocarcinoma↗

Lung cancer: performance of automated lung nodule detection applied to cancers missed in a CT screening program.

PURPOSE: To evaluate the performance of a fully automated computerized method for the detection of lung nodules in computed tomographic (CT) scans in the identification of lung cancers that may be missed during visual interpretation. MATERIALS AND METHODS: A database of 38 low-dose CT scans with 50 lung nodules was obtained from a lung cancer screening program. Thirty-eight of the nodules represented biopsy-confirmed lung cancers that had not been reported during initial clinical interpretation. A computer detection method that involved the use of gray-level thresholding techniques to identify three-dimensionally contiguous structures within the lungs was applied to the CT data. Computer-extracted volume was used to determine whether a structure became a nodule candidate. A rule-based scheme and a cascaded automated classifier were applied to the set of nodule candidates to distinguish actual nodules from areas of normal anatomy. Overall performance of the computer detection method was evaluated with free-response receiver operating characteristic (FROC) analysis. RESULTS: At a specific operating point on the FROC curve, the method achieved a sensitivity of 80% (40 of 50 nodules), with an average of 1.0 false-positive detection per section. Missed cancers were detected by the computerized method with a sensitivity of 84% (32 of 38 nodules) and a false-positive rate of 1.0 per section. CONCLUSION: With an automated lung nodule detection method, a large fraction (84%, 32 of 38) of missed cancers in a database of low-dose CT scans were detected correctly.

Aged↗