C-arm-based three-dimensional navigation: a preliminary feasibility study.

OBJECTIVE: With the new Siremobil Iso-C3D C-arm, three-dimensional (3D) datasets can be acquired intraoperatively in near-real time. Preliminary studies investigated the advantages of this system for depiction in joint and spinal surgery. Three-dimensional navigation seems feasible using the DICOM dataset of the Siremobil Iso-C3D in navigation devices. An experimental study was designed to investigate the feasibility and accuracy of this new technique. MATERIALS AND METHODS: After implantation of fiducial markers (titanium mini-screws, Leibinger), a Siremobil Iso-C3D C-arm with standard imaging options was used to acquire pre-interventional 3D datasets of the specimens. These isotropic voxel data were transferred via DICOM to a medivision navigation system using the spine module. After registration of the fiducials, a total of 20 pedicle screws were implanted (in 4 artificial-bone vertebral bodies and 6 cadaver vertebrae in situ) with the use of the navigation system in real-time mode. Post-interventionally, Iso-C3D and CT scans were obtained to control for implant position in the cadaver study. RESULTS: Fiducial marker implantation and registration require a special protocol to ensure correct identification and patient orientation in the DICOM dataset. The obtained accuracy was within 2 mm. Post-interventional imaging of the cadaveric vertebrae showed 10 of 12 screws to be correctly placed, with the other two in marginal intraosseous positions. CONCLUSIONS: Three-dimensional navigation with the Siremobil Iso-C3D data set is feasible, the accuracy being comparable to that of CT-based navigation and adequate for clinical interventions. Fiducial marker-based registration allows navigation of different bones in the same dataset without additional 3D scanning. This method is very useful as an additional tool in registration-free Iso-C3D-based navigation, since the navigation system allows the use of only one dynamic reference base (DRB).

Bone Screws↗

Photoelastic and thermoelastic measurement of stress on the proximal femur before and after implantation of a hip prosthesis with retention of the femoral neck.

This study demonstrated the improved medial support and the transfer of load onto the retained neck of the femur using seven fresh frozen femurs. Results confirm the reliability of the thermoelastic stress analysis method, which is comparable to the photoelastic surface coating method, but with greater sensitivity. The loading pattern after stem implantation shows a homogeneous transfer of force onto the preserved femoral neck. After femoral neck removal, an inhomogeneous increase of the intertrochanteric compression loading was observed. Therefore, improved biomechanical conditions are created for a permanently stable implantation of stem prostheses with retention of the femoral neck.

Femur↗