PubMed Health⌕ Search

PubMed · 14708757

C-arm-based three-dimensional navigation: a preliminary feasibility study.

Abstract

OBJECTIVE: With the new Siremobil Iso-C3D C-arm, three-dimensional (3D) datasets can be acquired intraoperatively in near-real time. Preliminary studies investigated the advantages of this system for depiction in joint and spinal surgery. Three-dimensional navigation seems feasible using the DICOM dataset of the Siremobil Iso-C3D in navigation devices. An experimental study was designed to investigate the feasibility and accuracy of this new technique. MATERIALS AND METHODS: After implantation of fiducial markers (titanium mini-screws, Leibinger), a Siremobil Iso-C3D C-arm with standard imaging options was used to acquire pre-interventional 3D datasets of the specimens. These isotropic voxel data were transferred via DICOM to a medivision navigation system using the spine module. After registration of the fiducials, a total of 20 pedicle screws were implanted (in 4 artificial-bone vertebral bodies and 6 cadaver vertebrae in situ) with the use of the navigation system in real-time mode. Post-interventionally, Iso-C3D and CT scans were obtained to control for implant position in the cadaver study. RESULTS: Fiducial marker implantation and registration require a special protocol to ensure correct identification and patient orientation in the DICOM dataset. The obtained accuracy was within 2 mm. Post-interventional imaging of the cadaveric vertebrae showed 10 of 12 screws to be correctly placed, with the other two in marginal intraosseous positions. CONCLUSIONS: Three-dimensional navigation with the Siremobil Iso-C3D data set is feasible, the accuracy being comparable to that of CT-based navigation and adequate for clinical interventions. Fiducial marker-based registration allows navigation of different bones in the same dataset without additional 3D scanning. This method is very useful as an additional tool in registration-free Iso-C3D-based navigation, since the navigation system allows the use of only one dynamic reference base (DRB).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ekkehard Euler, Sandro Heining, Christian Riquarts, Wolf Mutschler. 2003. C-arm-based three-dimensional navigation: a preliminary feasibility study.. https://doi.org/10.3109/10929080309146101

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Chronic whiplash syndrome is no indication for craniocervical fixation].

Throughout many years, a large number of publications have focused on structural changes in soft tissues in the cervical spine in patients with whiplash associated disorders I-II. In recent years the development in MRI techniques have made it possible to visualize the small ligaments in the craniocervical junction; a small number of publications have investigated the association between signal changes in these ligaments and whiplash associated disorders I-II. The results are, however, not conclusive, and no prospective studies have demonstrated any causal connection between type of whiplash injury and signal changes in these ligaments. Craniocervical fixation is major surgery with a moderate level of perioperative complications. There is also a theoretical risk of increasing the degenerative process in the level below the fixation. The indications for craniocervical fixation are now serious conditions like instability caused by rheumatic arthritis, tumours and fractures. The scientific evidence for introducing a new indication for craniocervical fixation is lacking, and craniocervical fixation in WAD I-II must be considered experimental surgery.

Bone Screws↗