PubMed Health⌕ Search

Biomedical subjects

Serge Bouillaguet

Publications and source records attributed to Serge Bouillaguet.

17 recordsLinked to original sources

Initial in vitro biological response to contemporary endodontic sealers.

The objective of this study was to evaluate the cytotoxicity of three endodontic sealers (AH Plus/Maillefer-Dentsply, Epiphany/Pentron, GuttaFlow, Coltene-Whaledent). Materials were mixed according to the manufacturer instructions and packed into Teflon molds (10 x 1 mm). For cytotoxicity testing (MTT method), the specimens were placed in contact with cultured cells, then evaluated at two subsequent time points (24 or 72 h). In addition to testing the mixed materials, 5 microl of primer liquid (GuttaFlow and Epiphany) and resin solvents (HEMA, ethanol, sterile water, or acetone) were added directly in culture for 24 and 72 h. The results showed that most materials pose significant cytotoxic risks and that cytotoxicity generally increased with time. At 72 h, GuttaFlow became significantly less toxic than AH Plus, Epiphany sealer, and Resilon. The current results support the need to continue to develop better endodontic sealers that combine the excellent sealing and bonding properties of resins with acceptable biological properties for endodontic applications.

Acetone↗

Sublethal concentrations of diverse gold compounds inhibit mammalian cytosolic thioredoxin reductase (TrxR1).

UNLABELLED: Thioredoxin reductase (TrxR) reduces thioredoxin (Trx), thereby contributing to cellular redox balance, facilitating the synthesis of deoxy-ribose sugars for DNA synthesis, and regulating redox-sensitive gene expression. Auranofin is a gold compound that potently inhibits TrxR. This inhibition is one suspected mechanism of auranofin's therapeutic benefit in the treatment of rheumatoid arthritis. The use of other gold compounds to treat cancer or inflammatory disease may rely on their ability to inhibit TrxR. In the current study, we tested the hypothesis that a variety of gold compounds may inhibit TrxR. METHODS: We exposed rat-TrxR1 to auranofin, gold sodium thiomalate, sodium aurothiosulfate, triphenyl phosphine gold chloride, or gold acetate, and measured TrxR activity ex vivo. We then compared TrxR1 inhibitory levels of gold compounds to those that inhibited mitochondrial activity of THP1 monocytes and OSC2 epithelial cells, estimated by succinate dehydrogenase activity. RESULTS: All gold compounds inhibited TrxR1 at concentrations ranging from 5 to 4000 nM (50% inhibitory concentration). The oxidation state of gold did not correlate with inhibitory potency, but ligand configuration was important. Au(I)-phosphine compounds (triphenyl phosphine gold chloride and auranofin) were the most potent inhibitors of TrxR. All TrxR1 inhibitory concentrations were sublethal to mitochondrial activity in both THP1 and OSC2 cells. CONCLUSIONS: Diverse types of gold compounds may be effective inhibitors of TrxR1 at concentrations that do not suppress cellular mitochondrial function. Inhibition may be optimized to some degree by altering the ligand configuration of the compounds. These results support future study of a variety of Au compounds for therapeutic development as inhibitors of TrxR1.

Animals↗

Hydrothermal and mechanical stresses degrade fiber-matrix interfacial bond strength in dental fiber-reinforced composites.

Fiber-reinforced composites (FRCs) show great promise as long-term restorative materials in dentistry and medicine. Recent evidence indicates that these materials degrade in vivo, but the mechanisms are unclear. The objective of this study was to investigate mechanisms of deterioration of glass fiber-polymer matrix bond strengths in dental fiber-reinforced composites during hydrothermal and mechanical aging. Conventional three-point bending tests on dental FRCs were used to assess flexural strengths and moduli. Micro push-out tests were used to measure glass fiber-polymer matrix bond strengths, and nanoindentation tests were used to determine the modulus of elasticity of fiber and polymer matrix phases separately. Bar-shaped specimens of FRCs (EverStick, StickTech, and Vectris Pontic, Ivoclar-Vivadent) were either stored at room temperature, in water (37 and 100 degrees C) or subjected to ageing (10(6) cycles, load: 49 N), then tested by three-point bending. Thin slices were prepared for micro push-out and nanoindentation tests. The ultimate flexural strengths of both FRCs were significantly reduced after aging (p < 0.05). Both water storage and mechanical loading reduced the interfacial bond strengths of glass fibers to polymer matrices. Nanoindentation tests revealed a slight reduction in the elastic modulus of the EverStick and Vectris Pontic polymer matrix after water storage. Mechanical properties of FRC materials degrade primarily by a loss of interfacial bond strength between the glass and resin phases. This degradation is detectable by micro push-out and nanoindentation methods.

Biomechanical Phenomena↗

Gold-induced reactive oxygen species (ROS) do not mediate suppression of monocytic mitochondrial or secretory function.

UNLABELLED: The toxicity of anti-rheumatic gold compounds has limited their use and development, yet both the toxicological and therapeutic actions of these compounds remain unclear. In the current study, we tested the hypothesis that intracellular reactive oxygen species (ROS) induced by Au(I) or Au(III) compounds mediate their ability to suppress mitochondrial activity. METHODS: Human THP1 monocytes were exposed to HAuCl(4) x 3H(2)O (Au(III)), or the anti-rheumatic compounds auranofin (AF) or gold sodium thiomalate (GSTM) for 6-72 h, after which mitochondrial activity (succinate dehydrogenase) was measured. To assess the role of cellular redox status as a mediator of mitochondrial suppression, monocytes were pre-treated with a pro-oxidant (t-butyl hydroquinone, t-BHQ) or antioxidant (N-acetyl cysteine, NAC ). ROS levels were measured 0-24h post-gold addition to determine their role as mediators of mitochondrial activity suppression. RESULTS: AF was the most potent inhibitor of mitochondrial activity, followed by Au(III) and GSTM. Only Au(III) induced intracellular ROS; no ROS formation was observed in response to AF or GSTM exposure. Although anti- and pro-oxidants had some effects on mitochondrial suppression of Au compounds, collectively the data do not support redox effects or ROS formation as major mediators of Au-compound mitochondrial suppression. CONCLUSIONS: Our results do not indicate that ROS and redox effects play major roles in mediating the cytotoxicity of AF, GSTM or Au(III).

Auranofin↗

Thermal risks from LED- and high-intensity QTH-curing units during polymerization of dental resins.

The aim of this study was to test the ability of an infrared (IR) camera to assess temperature changes and distributions in teeth below restorations when quartz-tungsten-halogen (QTH) and light-emitting diode (LED) curing lights were used to photopolymerize the restorative material. Our hypothesis was that the higher power density and broader spectral distribution of the QTH source would cause greater increases in tooth temperature than the LED source, and that these differences would be best demonstrated with the IR camera. Cavities were prepared on human third molars and restored with a resin composite restorative material. The material was light-cured using three light-curing sources using several exposure times. The external (outside the tooth) and internal (inside the pulp chamber) temperature changes during polymerization of the composite material were recorded over 360 s with thermocouples and an IR camera. Using thermocouples the maximum increase in external temperature (+17.7 degrees C) was reported for the Swiss Master light after 20 s of curing time while the minimum temperature rise (+7.8 degrees C) was reported for the Freelight 2. Whereas a 2.6 degrees C increase in internal temperature was observed after curing 20 s with the Freelight 2, 7.1 degrees C was reported after 60 s of light exposure to Astralis 10. Infrared images showed similar trends in external-internal rises in temperature as the thermocouples, although temperatures measured by the IR were generally higher. These results indicate that the higher power density QTH sources caused greater increases in tooth temperatures than the LED source and that thermocouples may underestimate the heat applied to the tooth.

Composite Resins↗

Light-curing time reduction with a new high-power halogen lamp.

INTRODUCTION: Orthodontic brackets are routinely bonded with light-cured adhesives. Conventional halogen lights used in bonding have the disadvantage of a long curing time, and the available alternatives (laser and plasma lights) are expensive. Our aim was to investigate the minimum time necessary to bond brackets with a new, relatively low-priced, high-power halogen light. METHODS: Five groups of 15 deciduous bovine incisors were bonded with stainless steel brackets (Mini Diamond Twin, Ormco, Orange, Calif) by using different lamps and curing times. Three of the groups were bonded by using a high-power halogen light (Swiss Master Light, Electro Medical Systems, Nyon, Switzerland) for 2, 3, and 6 seconds, respectively. The fourth group, bonded with a fast halogen light (Optilux 501, Sybron Dental Specialties, Danbury, Conn) for 40 seconds, served as the positive control group. The fifth group, the comparison group, was bonded with a plasma light (Remecure, Remedent, Deurle, Belgium) for 4 seconds. After storage for 24 hours in the dark at 37 degrees C in water, shear bond strength was measured with a universal testing machine. RESULTS: A curing time of 2 seconds with the high-power halogen light negatively affected the bond strength and the probability of bond survival. The adhesive remnant index scores were not significantly different among the groups. Most failures (> 60%) occurred at the bracket base/adhesive interface. CONCLUSIONS: The high-power halogen light seems to be a cost-effective solution to reducing curing time. The recommended curing times to bond stainless steel brackets are 6 seconds and, with caution, even 3 seconds.

Analysis of Variance↗

Resin composite shrinkage and marginal adaptation with different pulse-delay light curing protocols.

The aims of this study were, first, to measure shrinkage induced by different methods of pulse-delay light curing and, second, to verify their influence on the marginal adaptation of class V restorations in enamel and dentin. Eight groups, comprising seven groups (n = 6) with different pulse-delay parameters and a control group, were compared for dynamic linear displacement and force by using a fine hybrid composite. Based on these results, the pulse-delay curing procedure with the lowest shrinkage force was chosen and tested against the control group with respect to marginal adaptation in class V restorations (n = 8) before and after simultaneous thermal and mechanical loading. Statistically significant differences between groups were found for both shrinkage properties tested, with one pulse-delay group giving the lowest overall shrinkage values. However, the percentages of 'continuous margin' of this group, and of the control before and after loading, were not significantly different in dentin, whereas a significantly lower percentage of 'continuous margin' was detected in the pulse-delay group in enamel after loading.

Composite Resins↗

Sublethal concentrations of Au (III), Pd (II), and Ni(II) differentially alter inflammatory cytokine secretion from activated monocytes.

Many transition metals have been viewed collectively as nonspecific biological toxins in cells, which has limited investigation into their possible therapeutic effects. In the current study, the effects of Au(III), Ni(II), and Pd(II) on the differential secretion of cytokines from monocytes has been investigated. This is critical to understanding any therapeutic potential of these metals, their allergenicity, or the clinical effects of current metal therapies such as chrysotherapy. Lethal concentrations (defined as > 50% suppression of mitochondrial succinate dehydrogenase (SDH) activity) of metals were determined by dose-response curves with the use of 72 h exposures to human THP-1 monocytes. Then, secretion of TNFalpha, IL1beta, and IL6 were measured after the monocytes were exposed to sublethal concentrations of metals, with or without stimulation by lipopolysaccharide. The concentrations of Au(III), Pd(II), and Ni(II) required to suppress SDH activity by 50% were found to be 255, 270, and 90 microM, respectively. No sublethal concentration of any metal alone caused secretion of the cytokines. However, LPS-induced cytokine secretion was significantly and differentially altered by sublethal concentrations of each metal. Differential responses were highly dependent on metal concentration and involved both suppression and potentiation of the LPS activation. In the case of Ni(II), potentiation of TNFalpha, IL1beta, and IL6 ranged from 200% for TNFalpha to over 1200% for IL6. Metals such as Au(III), Pd(II), and Ni(II) differentially alter cytokine expression from monocytes. These results imply that metals have more specific effects on cell signaling than previously assumed. These results also are important in explaining multiple clinical effects often seen with chrysotherapy, identifying potential new avenues for metal therapy, and understanding the inflammatory effects of metals such as nickel.

Cell Line↗

BIOLOGICAL RISKS OF RESIN-BASED MATERIALS TO THE DENTIN-PULP COMPLEX.

Over the past 30 years, restorative dentistry has seen a revolution in materials, restorative techniques, and patient priorities. This revolution has been made possible with the development of new resin-based materials which can be bonded to the tooth structure. Not all of these changes have been without controversy or concern, and some have raised questions about the biological safety of these new materials and techniques. It is the purpose of this review to present recent and relevant information about the biological risks and consequences of resin-tooth bonding and how these risks are affected by the material, its clinical properties, and its manipulation by the practitioner. These biological risks are complex and interactive, and are still incompletely defined. In broad terms, these risks can be divided into those stemming from the toxicological properties of the materials themselves (direct biological risks) and those stemming from microbiological leakage (indirect biological risks).

Journal Article↗

Cytotoxicity and sealing properties of four classes of endodontic sealers evaluated by succinic dehydrogenase activity and confocal laser scanning microscopy.

The objectives of this study were to evaluate the cytotoxicity and sealing properties of four classes of endodontic sealers (PCS/Kerr, RoekoSeal/Roeko, TopSeal/Dentsply, and EndoREZ/Ultradent). For cytotoxicity testing (MTT method), the materials were either placed immediately in contact with cultured cells or 24 h after setting, then evaluated at three subsequent time points (24 h, 48 h, or 1 wk). For the leakage study, extracted human roots were obturated with acrylic cones and sealers and immersed for 48 h into rhodamine-labeled lipopolysaccharide. The roots were then observed under a confocal laser scanning microscope to estimate (semiquantitatively) the presence of the rhodamine-lipopolysaccharide (LPS) inside the canal. The results showed that cytotoxicity generally increased with time, and that most materials pose significant cytotoxic risks, particularly in the freshly mixed condition. Further, all materials showed significant leakage although there was large variation among teeth. Overall, the silicon-based material (Roeko Seal) was less cytotoxic and more effective in sealing root canals against LPS leakage than other materials.

Analysis of Variance↗

Toothbrushing causes elemental release from dental casting alloys over extended intervals.

The release of elements from dental alloys has been linked to alloy biocompatibility. Much of the research measuring elemental release has been done in vitro under passive conditions. The current study supplements a previous report that measured elemental release from dental alloys during and after the equivalent of 1 week of toothbrushing. In the current study, toothbrushing times were extended to the equivalent of 2 years, and elemental release was measured during and after brushing, with and without toothpaste. The results showed that for the major classes of dental alloys, brushing alone caused no significant elemental release during the brushing, and only minor increases after brushing. Brushing with toothpaste caused significant increases in elemental release for all elements of all alloys, but the largest increases were for the two nickel-based alloys. Nickel released during brushing with toothpaste reached 600-800 microg/cm(2) of alloy surface. Both beryllium-containing and non-beryllium-containing nickel-based alloys behaved similarly, refuting claims that non-beryllium alloys are superior in this regard. Thus, brushing with toothpaste under these extended in vitro conditions appears to increase the biological liabilities from elemental release for all alloys, but primarily for nickel-based alloys.

Alloys↗

In vitro cytotoxicity of traditional versus contemporary dental ceramics.

STATEMENT OF PROBLEM: The biocompatibility of new dental ceramics has not been assessed with the same scrutiny as has been applied to alloys and composites. Yet, the biocompatibility of ceramics is critical to the long-term success of dental prostheses because ceramics are in close contact with oral tissues for extended periods. MATERIAL AND METHODS: Five dental ceramics (2 traditional feldspathic veneer porcelains [Vita Omega and Duceragold], 2 lithium disilicate pressable materials [Stylepress and Empress-2], and a pressable leucite-based material [Empress-1]) were tested for their ability to alter cellular mitochondrial dehydrogenase activity after fabrication using a tetrazolium assay, after aging for 2 weeks in a biologic solution and after post-aging polishing with either a fine diamond or diamond polishing paste. Cellular responses were compared with polytetrafluoroethylene controls (analysis of variance, Tukey pairwise post-hoc comparison, alpha=.05). RESULTS: The feldspathic porcelains caused only mild (<25% of controls) mitochondrial suppression regardless of aging or polishing. The pressable leucite-based material initially caused a 5% stimulation (not significant) of mitochondrial activity, which decreased significantly (P<.05) by 30% with aging to levels comparable to the feldspathic porcelains, and did not change with polishing. Both lithium disilicate materials caused an initial suppression of mitochondrial activity that decreased significantly with aging, but Empress-2 was severely cytotoxic initially (<20% of controls, P<.01), and became more cytotoxic again after polishing. Stylepress was less cytotoxic initially (85% of controls, not significant) and did not become cytotoxic again after polishing. CONCLUSIONS: Dental ceramics are not equivalent in their in vitro biologic effects, even within the same class of material, and biologic safety should not be assumed. Most ceramics caused only mild in vitro suppression of cell function to levels that would be acceptable on the basis of standards used to evaluate alloys and composites. However, 1 Li-disilicate material (Empress-2) exhibited cytotoxicity that would not be deemed biologically acceptable on the basis of prevailing empirical standards for dental alloys and composites.

Aluminum Silicates↗

In vitro biological response to core and flowable dental restorative materials.

OBJECTIVES: In vitro cytotoxicities of commercially available core and flowable dental restorative materials were assessed and compared to traditional resin composites. Our hypothesis was that the increased resin diluents added to achieve higher flow in flowables would increase cytotoxicities, whereas the higher filler content of core materials would decrease cytotoxicities relative to traditional resin composites. METHODS: Specimens were made under aseptic conditions, then extracted into an artificial saliva solution for 0-4 weeks, to assess the effect of aging on cytotoxicity. After extraction, specimens were tested for cytotoxicity in vitro using Balb/c fibroblasts in direct contact format. Cells were exposed to the materials for 48h, after which the mitochondrial activity of the cells was measured (MTT method). Cellular activity was normalized to Teflon negative controls. RESULTS: Core materials were uniformly and severely (<50% of Teflon cellular activity) cytotoxic initially, but several materials (Corepaste, Definite core) improved somewhat with aging in artificial saliva. Flowable materials were uniformly and severely cytotoxic with no trend toward improvement with aging. The Definite-flow was the least cytotoxic of the flowable materials, but it too was severely cytotoxic. SIGNIFICANCE: Commercially available core and flowable restorative materials showed severe in vitro cytotoxicities that are worse than some traditional composites and most dental casting alloys and amalgams used today. Of particular note was the persistent cytotoxicity of these materials after 4 weeks of extraction with artificial saliva. These cytotoxicities indicate a continuing release of mass from these materials at levels that have biological relevance in vitro. In vivo relevance of these cytotoxicities is less clear, but these results indicate a higher biological risk for these materials compared to traditional materials that exhibit less initial toxicity and improve with aging time.

3T3 Cells↗

Microtensile bond strength between adhesive cements and root canal dentin.

OBJECTIVES: The hypotheses tested were that the bond strength of adhesive cements to root canal dentin (1) would be reduced as a function of configuration factor, polymerization process and type of luting material and (2) would be lowered near the apex of the tooth. METHODS: Human canines and premolars were prepared for post cementation using Single Bond/Rely X ARC, ED Primer/Panavia F, C and B Metabond, and Fuji Plus. The specimens were divided into two groups. For intact roots, the posts were luted using standard clinical procedures. For flat roots, the posts were applied directly into flat ground canals. All roots were sectioned into 0.6 mm thick slices, trimmed mesio-distally and stressed to failure at 1 mm/min. The muTBS of each slab was calculated as the force at failure divided by the bonded cross-sectional surface area. The results were compared using a one-way ANOVA and Tukey multiple comparison intervals (alpha=0.05). Least squares linear regression analysis was used to assess the effect of dentin location on bond strength. RESULTS: All cements showed significantly (p</=0.05) lower bond strengths in intact vs. flat roots. The muTBS of posts to intact roots were not significantly different for Single Bond/Rely X ARC and Panavia F, but both were significantly lower (p</=0.05) than the bonds produced by C and B Metabond and Fuji Plus cements. For Single Bond/Rely X ARC and Fuji Plus a significant decrease in bond strength was observed in dentin closer to the apex of the root. SIGNIFICANCE: Stresses from polymerization shrinkage and problems with adequate access to the root canal complicate the formation of high-strength bonds when cementing endodontic posts with resin cements.

Analysis of Variance↗

Replacement of missing teeth with fiber-reinforced composite FPDs: clinical protocol.

The concept of minimally invasive preparation protocols has resulted in reduced loss of critical tooth structures and maintenance of optimal strength, form, and aesthetics. While various treatment options have been described for single-tooth replacement, fiber-reinforced composite (FRC) fixed partial dentures (FPDs) provide a viable treatment alternative with proven mechanical properties, aesthetics, and function. This article presents several clinical scenarios in which minimally invasive adhesive FRC FPDs are provided to deliver enhanced predictability, strength, and durability.

Aged↗

[Characterization of three light sources. Study of their efficiency].

Light-emitting sources are currently used to activate the setting reaction of restorative composite resins. It is well known that the polymerization extent of the resins will highly influence their clinical behavior. The monomer-polymer transformation will mostly depend on the chemical nature of the photo-initiators used and on the luminous energy given by the curing device. The aims of this study were to characterize three light curing devices and to compare their efficiency to polymerize a composite resin (SureFil). For that purpose, the emission spectra and the irradiance of a plasma arc (Flipo), a QTH visible light (Elipar Trilight), and a LEDs curing device (Elipar Freelight) were measured. Then, the depth of cure and the Vickers hardness of composite samples were evaluated, for each curing device, as a function of the exposure time. The emission spectra obtained showed the irradiance of the visible light emitted as a function of the wavelength, which was different for each light-curing device. The maximum cured depth (approximately 4 mm) give only a qualitative indication of the extent of the polymerization, as the hardness of the composite samples diminished as a function of the depth. Moreover, it strongly depended on the exposure time. Hence, to obtain a hardness of approximately 100 HV 0.5 at 2 mm depth, the illumination time must be at least of 3 s with the plasma arc Flipo, 10 s with the LEDs Elipar Freelight and 20 s with the QTH Elipar Trilight. In order to efficiently polymerize a composite resin, the emission spectra of the luminous source shall correspond with the absorption spectra of the photo-initiators. The present study showed that the LEDs Elipar Freelight is the most efficient curing device when the camphorquinone is used, as 92% of the emitted energy will be absorbed by the initiator. However, the power of this source is relatively low, hence higher exposure time shall be used.

Composite Resins↗

Bonding to dentin achieved by general practitioners.

The objectives of this study were (1) to investigate the effect of operator variability on the shear bond strength of adhesives to dentin and (2) to determine the effectiveness of education on bonding performance for different types of adhesives. Thirty general practitioners were recruited for a CE course by a regional mailing. They used bovine dentin as a substrate for bonding the adhesive system they routinely used in practice and two other materials (no previous experience). Each adhesive OptiBond FL, ScotchBond Multipurpose Plus, ScotchBond 1 and Clearfil SE was applied according to manufacturer's instructions and immediately tested using a shear bond strength test. Shear bond strengths between adhesives and dentin were compared before and after a 90 min lecture on bonding principles and materials. For dentists with and without previous experience with a material, there were no statistically significant differences seen before and after the lecture (paired t-tests, p < or = 0.05). However, in every case, the bond strengths after the lecture were higher than those before (range of improvement from 15 to 150%). For dentists with routine experience with a particular material, all materials were statistically equivalent after the lecture, although the OptiBond FL was the highest. For dentists who had no previous experience with a material, the ScotchBond 1 had lower bond strengths than the other materials after the lecture. There was a large range in the ability of dentists to manipulate adhesive systems correctly. However, if a dentist has sufficient experience and receives sufficient education, any of these materials can give reasonable results.

Analysis of Variance↗