PubMed Health⌕ Search

Biomedical subjects

Sheng-Wen Huang

Publications and source records attributed to Sheng-Wen Huang.

10 recordsLinked to original sources

Arbitrary waveform coded excitation using bipolar square wave pulsers in medical ultrasound.

This paper presents a new coded excitation scheme that efficiently synthesizes codes for arbitrary waveforms using a bipolar square wave pulser. In a coded excitation system, pulse compression is performed to restore the axial resolution. In order to maintain low range sidelobes, the system needs to transmit signals that have smooth spectra. However, such a transmitter requires the generation of arbitrary waveforms and, therefore, is more expensive. In other words, a trade-off is necessary between the compression performance and the transmitter cost. Here we propose a method that preserves the low-cost advantage of a bipolar pulser while achieving approximately the same compression performance as an arbitrary waveform generator. The key idea of the proposed method is the conversion of a nonbinary code (i.e., requiring an arbitrary waveform generator) with good compression performance into a binary code (i.e., requiring only a bipolar pulser) by code translation and code tuning. The code translation is implemented by sending the nonbinary code into a virtual one-bit, sigma-delta modulator, and the code tuning involves minimizing the root-mean-square error between the resultant binary code and the original nonbinary code by sequential and iterative tuning while taking the transducer response into account. Tukey-windowed chirps are known to have good compression performance. Such chirps of different durations (16, 20, and 24 micros), all with a taper ratio of 0.15, a center frequency of 2.5 MHz, and an equivalent bandwidth of 1.5 MHz, were converted into binary Tukey-windowed chirps that were compared with pseudochirps (i.e., direct binary approximations of the original chirp) over the same spectral band. The bit rate was 40 MHz. Simulation results show that the use of binary Tukey-windowed chirps can reduce the code duration by 20.6% or the peak sidelobe level by 6 dB compared to the commonly used pseudochirps. Experimental results obtained under the same settings were in agreement with the simulations. Our results demonstrate that arbitrary waveform coded excitation can be realized using bipolar square wave pulsers for applications in medical ultrasound.

Algorithms↗

Increasing appearance of reassortant influenza B virus in Taiwan from 2002 to 2005.

Genetic and antigenic analyses of influenza B virus field strains isolated in Taiwan from 1998 to 2005 were performed. To investigate the molecular evolution of influenza B viruses, sequence analysis of the hemagglutinin (HA1 subunit) and neuraminidase genes was performed. All influenza B viruses isolated between 1998 and 2000 belonged to the B/Yamagata/16/88 lineage. The B/Victoria/2/87 lineage, which was cocirculating with the Yamagata lineage, was identified in Taiwan in March 2001. Concurrently, there was an increasing prevalence of this lineage in many parts of the world, including North America and Europe, during the 2001-2002 season. Since 2002, genetic reassortants of influenza B virus with the Victoria lineage of hemagglutinin and the Yamagata lineage of neuraminidase have been found at a rate of 46%. Therefore, in 2002, at least three sublineages of influenza B virus strains, the B/Shanghai/361/2002-like strain (Yamagata lineage), the B/Hong Kong/330/01-like strain (Victoria lineage), and the B/Hong Kong/1351/02-like strain (B reassortant lineage), were identified in Taiwan. The results showed that genetically distinct lineages can cocirculate in the population and that the reassortment among these strains plays a role in generating the genetic diversity of influenza B viruses. Interestingly, from January to April 2005, B reassortant viruses became dominant (73%) in Taiwan, which indicated that a mismatch had occurred between the influenza B vaccine strain recommended for the 2004-2005 season in the Northern hemisphere by the World Health Organization and the epidemic strain.

Antigens, Viral↗

Waveform design for ultrasonic pulse-inversion fundamental imaging.

Pulse-inversion (PI) fundamental imaging exhibits significantly better contrast detection than linear and second-harmonic imaging. PI fundamental imaging involves two firings with inverted waveforms. When the returning echoes from the two firings are summed, the residual signal related to tissue is limited to even-order harmonics, whereas for microbubbles, the fundamental signal is not completely canceled due to the echo under compression differing from that under rarefaction. The efficacy of PI fundamental imaging has been reported previously. In this study, we investigated the performance of PI fundamental imaging using both simulations and in vitro experiments with various transmit waveforms, including coded excitation and asymmetrical waveforms (i.e., asymmetrical between compression and rarefaction). For coded excitation, a longer waveform was found to increase the similarity in the responses to positive and negative pulses, thus lowering the contrast between microbubbles and tissue. In addition, imperfect pulse compression also decreases the contrast because it increases the residue fundamental signal emanating from tissue. Using asymmetrical waveforms noticeably increased the residual microbubble signal in the fundamental band but the nonzero DC component that is inherent in such waveforms also increases the tissue fundamental signal. The combination of these two effects decreases the contrast. From these results, it is concluded that the use of coded excitation is undesirable in PI fundamental imaging and that the waveforms should contain no DC component. Furthermore, the transmit waveform needs to be appropriately windowed in order to reduce spectral leakage. Therefore, a Gaussian pulse with the pulse length determined by the signal-to-noise ratio of the imaging system is generally optimal for PI fundamental imaging.

Artifacts↗

Photoacoustic flow measurements by use of laser-induced shape transitions of gold nanorods.

A quantitative technique for flow measurements based on a wash-in analysis is proposed. The technique makes use of the shape dependence of the optical absorption of gold nanorods and the transitions in their shape induced by pulsed laser irradiation. The photon-induced shape transition of gold nanorods involves mainly a rod-to-sphere conversion and a shift in the peak optical absorption wavelength. The application of a series of laser pulses will induce shape changes in gold nanorods as they flow through a region of interest, with quantitative flow information being derived from the photoacoustic signals from the irradiated gold nanorods measured as a function of time. To demonstrate the feasibility of the technique, a Nd:YAG laser operating at 1064 nm was used for irradiation and a 1 MHz ultrasonic transducer was used for acoustic detection. The flow velocity ranged from 0.35 to 2.83 mm/s. Excellent agreement between the measured velocities and the actual velocities was demonstrated, with a linear regression correlation coefficient of 0.93. This study is a pioneer work on wash-in flow estimation in photoacoustic imaging.

Acoustics↗

Optical piezoelectric transducer for nano-ultrasonics.

Piezoelectric semiconductor strained layers can be treated as piezoelectric transducers to generate nanometer-wavelength and THz-frequency acoustic waves. The mechanism of nano-acoustic wave (NAW) generation in strained piezoelectric layers, induced by femtosecond optical pulses, can be modeled by a macroscopic elastic continuum theory. The optical absorption change of the strained layers modulated by NAW through quantum-confined Franz-Keldysh (QCFK) effects allows optical detection of the propagating NAW. Based on these piezoelectric-based optical principles, we have designed an optical piezoelectric transducer (OPT) to generate NAW. The optically generated NAW is then applied to one-dimensional (1-D) ultrasonic scan for thickness measurement, which is the first step toward multidimensional nano-ultrasonic imaging. By launching a NAW pulse and resolving the returned acoustic echo signal with femtosecond optical pulses, the thickness of the studied layer can be measured with <1 nm resolution. This nano-structured OPT technique will provide the key toward the realization of nano-ultrasonics, which is analogous to the typical ultrasonic techniques but in a nanometer scale.

Electrochemistry↗

Ultrasonic computed tomography reconstruction of the attenuation coefficient using a linear array.

The attenuation coefficient distribution and sound velocity distribution in the breast can be used to complement B-mode ultrasound imaging in the detection of breast cancer. This study investigated an approach for reconstructing the attenuation coefficient distribution in the breast using a linear array. The imaging setup was identical to that for conventional B-mode breast imaging, and the same setup has been used for reconstruction of sound velocity distributions in previous studies. In this study, we further developed a reconstruction method for the attenuation coefficient distribution. In particular, the proposed method incorporates the segmentation information from B-mode images and uses the sound velocity distribution to compensate for refraction effects. Experiments were conducted with a setup consisting of a 5-MHz, 128-channel linear array, a programmable digital array system, a phantom, and a computer. The constructed phantom contained materials mimicking the following breast tissues: glandular tissue, fat, cysts, high-attenuation tumors, and irregular tumors. Application of the proposed technique resulted in all the cysts and tumors (including high-attenuation and irregular tumors) being distinguished by thresholding the reconstructed attenuation coefficients. We have demonstrated that it is possible to use the same imaging setup to acquire data for B-mode image, sound velocity distribution, and attenuation coefficient distribution simultaneously. Moreover, the experimental data indicate its potential in improving the detection of breast cancer.

Algorithms↗

Adaptive imaging using an optimal receive aperture size.

Sidelobe contribution from off-axis targets degrades image quality in a coherent array imaging system. In ultrasound imaging, focusing errors resulting from sound-velocity inhomogeneities in human tissue--also known as phase aberrations reduce the coherence of the received signals and elevate the sidelobe level. This paper proposes an adaptive receive-aperture technique based on thresholding of the coherence factor (CF). The CF describes the coherence of the received array signals and can be used as an index of focusing quality. This paper demonstrates that thresholding of the CF allows the mainlobe-dominated signals to be distinguished from the sidelobe-dominated signals, after which the receive-aperture size at each imaging position can be optimally determined so as to enhance the mainlobe-dominated signals and suppress the sidelobe-dominated signals. Thus, image quality degradation resulting from sound-velocity inhomogeneities can be reduced. Simulations and measured ultrasound data are used to evaluate the efficacy of the proposed technique. The characteristics of the proposed technique including the effects of the signal-to-noise ratio (SNR) and the transmit focal depth, and speckle reduction are discussed. The proposed technique is also compared with the parallel adaptive receive compensation algorithm and shown to produce a better improvement in image quality.

Algorithms↗

Experimental investigation of computed tomography sound velocity reconstruction using incomplete data.

An approach for reconstructing the sound velocity distribution in the breast was previously proposed and verified by simulations, and the present study investigated the approach experimentally. The experimental setup comprised a 5-MHz, 128-channel linear array, a programmable digital array system, a phantom containing objects with differing physical properties, and a computer. The array system was used to collect channel data for simultaneous B-mode image formation and limited-angle tomographic sound velocity reconstruction. The phantom was constructed from materials mimicking the following tissues in the breast: glandular tissue, fat, cysts, high-attenuation tumors, and irregular tumors. The sound velocities in these materials matched those in the corresponding real tissues. The imaging setup is similar to that of x-ray mammography, in which a linear array is placed at the top of the breast and a metal plate is placed at the bottom for reflecting sound waves. Thus, both B-mode images and the sound velocity distribution can be acquired using the same setup. An algorithm based on a convex programming formulation was used to reconstruct the sound velocity images. By scanning the phantom at different positions, nine cases were evaluated. In each of the nine cases, the image object comprised a background (glandular tissue) and one or three regions of interest (fat, tumor, or cyst). The sound velocity was accurately estimated in the nine cases evaluated, with sound velocity errors being less than 5 m/s in 8 of 11 regions of interest. Thus, obtaining the sound velocity distribution is feasible with a B-mode imaging setup using linear arrays. Knowledge of the sound velocity distribution in the breast can be used to complement B-mode imaging and to enhance the detection of breast cancer.

Breast Neoplasms↗

Computed tomography sound velocity reconstruction using incomplete data.

An approach based on limited-angle transmission tomography for reconstruction of the sound velocity distribution in the breast is proposed. The imaging setup is similar to that of x-ray mammography. With this setup, the time-of-flight data are acquired by a linear array positioned at the top of the compressed breast that both transmits and receives, and a metal plate is placed at the bottom as a reflector. The setup allows acoustic data acquisition for simultaneous B-mode image formation and the tomographic sound velocity reconstruction. In order to improve the sound velocity estimation accuracy, a new reconstruction algorithm based on a convex programming formulation has been developed. Extensive simulations for both imaging and time-of-flight data based on a 5-MHz linear array were performed on tissues with different geometries and acoustic parameters. Results show that the sound velocity error was generally 1-3 m/s, with a maximum of 5.8 m/s. The radii of the objects under investigation varied from 2 to 6 mm, and all of them were detected successfully. Thus, the proposed approach has been shown to be both feasible and accurate. The approach can be used to complement conventional B-mode imaging to further enhance the detection of breast cancer.

Algorithms↗

Liver fibrosis grade classification with B-mode ultrasound.

B-mode images of 20 fresh postsurgical human liver samples were obtained to evaluate ultrasound ability in determining the grade of liver fibrosis. Image features derived from gray level concurrence and nonseparable wavelet transform were extracted to classify fibrosis with a classifier known as the support vector machine. Each liver sample subsequently underwent histologic examination and liver fibrosis was graded from 0 to 5 (i.e., six grades total). The six grades were then combined into two, three, four and six classes. Classifications with the extracted image features by the support vector machine were tested and correlated with histology. The results revealed that the best classification accuracy of two, three, four and six classes were 91%, 85%, 81% and 72%, respectively. Thus, liver fibrosis can be noninvasively characterized with B-mode ultrasound, even though the performance declines as the number of classes increases. The elastic constants of 16 samples out of a total of 20 were also correlated with the image features. The Pearson correlation coefficients indicated that the image features are more strongly correlated with the fibrosis grade than with the elastic constant.

Humans↗