Waveform design for ultrasonic pulse-inversion fundamental imaging.

Abstract

Pulse-inversion (PI) fundamental imaging exhibits significantly better contrast detection than linear and second-harmonic imaging. PI fundamental imaging involves two firings with inverted waveforms. When the returning echoes from the two firings are summed, the residual signal related to tissue is limited to even-order harmonics, whereas for microbubbles, the fundamental signal is not completely canceled due to the echo under compression differing from that under rarefaction. The efficacy of PI fundamental imaging has been reported previously. In this study, we investigated the performance of PI fundamental imaging using both simulations and in vitro experiments with various transmit waveforms, including coded excitation and asymmetrical waveforms (i.e., asymmetrical between compression and rarefaction). For coded excitation, a longer waveform was found to increase the similarity in the responses to positive and negative pulses, thus lowering the contrast between microbubbles and tissue. In addition, imperfect pulse compression also decreases the contrast because it increases the residue fundamental signal emanating from tissue. Using asymmetrical waveforms noticeably increased the residual microbubble signal in the fundamental band but the nonzero DC component that is inherent in such waveforms also increases the tissue fundamental signal. The combination of these two effects decreases the contrast. From these results, it is concluded that the use of coded excitation is undesirable in PI fundamental imaging and that the waveforms should contain no DC component. Furthermore, the transmit waveform needs to be appropriately windowed in order to reduce spectral leakage. Therefore, a Gaussian pulse with the pulse length determined by the signal-to-noise ratio of the imaging system is generally optimal for PI fundamental imaging.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pai-Chi Li, Che-Chou Shen, Sheng-Wen Huang. 2006. Waveform design for ultrasonic pulse-inversion fundamental imaging.. https://doi.org/10.1177/016173460602800301

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗