Chiral micellar electrokinetic chromatography.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Shigeru Terabe.
Explore the source record for details and available documents.
In this article, it was demonstrated that a subsecond separation of cellular metabolites such as riboflavin (RF), flavin mononucleotide (FMN), and flavin-adenine dinucleotide (FAD) was achieved using microchip capillary electrophoresis with laser-induced fluorescence detection. The influences of crucial parameters that governed analysis time (e.g., channel length and electric field for separation) and separation resolution (e.g., sample size) were investigated, both in theoretical aspects and experimental practice. Quantitative analyses were performed that exhibited linear dynamic range of two orders of magnitude, with calculated detection limits of 34, 201, and 127 nM for RF, FAD, and FMN, respectively. To test the validity of the method, it was successfully applied to characterize several recombinant flavin-binding domains in a human neuronal nitric oxide synthase.
To improve the detection sensitivity of metal ions in capillary zone electrophoresis (CZE), a novel method that combines complex formation and on-line sample preconcentration by sweeping was developed. Sweeping is defined as the picking and accumulating of analytes by a carrier in the background solution, with which they have considerable affinity. In this sweeping method, using ethylenediaminetetraacetic acid as carrier, dynamic complexation to form a UV-absorbing chelate and on-line preconcentration occur simultaneously during a run. The technique was validated in terms of the limit of detection, reproducibility, and sensitivity enhancement. Detection responses of some divalent metal ions, in terms of peak heights, were improved from 60- to 180-fold, relative to conventional CZE which employed precapillary complexation. The limits of detection were in the range of (1.8-23.4) x 10(-8) M. This method was applied to the analysis of trace metal ions in factory wastewater. Furthermore, sweeping in conjunction with sample stacking accompanying electrokinetic injection, cation-selective exhaustive injection (CSEI-sweeping), was also examined. Up to 140 000-fold improvement in detector responses for some divalent and trivalent metal ions was realized by CSEI-sweeping. The limits of detection were in the range (2.4-25.2) x 10(-11) M.
To improve detection sensitivity of cationic analytes, a dynamic pH junction technique was examined. Dynamic pH junction is an on-line focusing method in capillary electrophoresis (CE) based on the difference in the analyte's mobility between the background electrolyte (BGE) and sample matrix. The effects of pH values and concentrations of the BGE and the sample matrix on dynamic pH junction were examined. Optimization of analyte focusing resulted in enhanced detection responses of about 100-160-fold in terms of peak heights for some anilines in comparison to conventional injections. In particular, the concentration limits of detection (LOD) (S/N = 3) for the test anilines obtained with dynamic pH junction were from 1.9 to 3.7 ppb with UV detection without any pretreatment procedure.
Separation and on-line concentration of bisphenol A and three alkylphenols were investigated by micellar electrokinetic chromatography with the anionic surfactant, sodium dodecyl sulfate. The separation conditions were optimized by the simultaneous addition of the organic solvent and cyclodextrin to the running solution. The separation of hydrophobic analytes and 4-nonylphenol isomers was improved by the addition of 10% methanol and 5 mM beta-cyclodextrin to the running solution. When the sweeping with the running solution was used as the on-line concentration procedure, 69-, 48-, 55- and 41-fold increases in detection sensitivity were obtained for bisphenol A, 4-tert.-butylphenol and 4-(1,1,3,3-tetramethylbutyl)phenol, and the second peak of 4-nonylphenol isomers, respectively. The detection limits were 0.0071, 0.0065, 0.021 and 0.055 mg/l, respectively. These results were better than those with the cationic surfactant, tetradecyltrimethylammonium bromide.
Complementary on-line preconcentration strategies are needed when analyzing different classes of solutes in real samples by capillary electrophoresis (CE) with UV detection. The performance of three different on-line preconcentration (focusing) techniques under alkaline conditions was examined in terms of their selectivity and sensitivity enhancement for a group of steroids, including classes of androgens, corticosteroids and estrogens. Electrokinetic focusing of large sample injection plugs (up to 28% of effective capillary length or 22.1 cm) directly on-capillary can be tuned for specific classes of steroids based on changes in their mobility (velocity) using a multi-section electrolyte system in CE. A dynamic pH junction was applied for the selective resolution and focusing of weakly acidic estrogens using borate, pH 11.0 and pH 8.0 in the background electrolyte and the sample, respectively. Sweeping, using an anionic bile acid surfactant and neutral gamma-cyclodextrin (gamma-CD) under alkaline conditions (pH 8), resulted in focusing and separation of the moderately hydrophobic (non-ionic) classes of steroids, such as androgen and corticosteroids. Optimal focusing and resolution of all test steroids under a single buffer condition was realized by a dynamic pH junction-sweeping format using borate, pH 11.0 and bile acid surfactant with gamma-CD in the BGE, whereas the sample is devoid of surfactant at pH 8.0. The design of selective on-line focusing strategies in CE is highlighted by the analysis of microgram amounts of ethynyl estradiol derived from a female contraceptive pill extract using the dynamic pH junction method, which resulted in over a 100-fold enhancement in concentration sensitivity.
A robust and simple interface for microchip electrophoresis-mass spectrometry (MCE-MS) was developed using a spray nozzle connected to the exit of the separation channel of the microchip. The spray nozzle was attached to the microchip using a polyether ether ketone screw without adhesive, thus allowing easy replaced. Sample injection and electrophoretic separation was performed by control of the voltage only. The analysis of a few basic drugs was performed using the optimized MCE-MS system. The separation was improved by using a high-viscosity separation buffer and a spray nozzle with a small bore size. This system was also applied to the separation of peptides and protein-trypsin digests. Sample adsorption was minimized by adding acetonitrile to the separation buffer when using a quartz microchip.
With a growing interest in metabolome analysis, there is a need for developing robust methods for analysis of intracellular metabolites profiles in real samples like e.g., bacteria cell. Due to their weak absorbance properties, tri- and dicarboxylic acids from TCA cycle (citric, isocitric, 2-oxoglutaric, succinic, fumaric, malic) as well as carboxylic acid metabolites from glycolysis pathway, urea cycle and metabolism of amino compounds (formic, pyruvic, lactic, acetic, glutamic) were analyzed by capillary electrophoresis (CE) with indirect UV detection. Using 4 mM 2,6-pyridinedicarboxylic acid as a highly UV absorbing carrier electrolyte, 0.2 mM cetyltrimethylammonium bromide, 10% ethylene glycol and 10% acetonitrile, pH 3.5, carboxylic acids metabolites were analyzed in Bacillus subtilis cell extract from two different cultures: glucose and malate. CE with an electrokinetic injection mode achieved limits of detection in the range of 13-54 ppb (1.12-10(-7) - 5.96-10(-7) M). The reproducibility and linearity of method was investigated with RSD for migration time less than 1.3% and acceptable correlation coefficients. The optimized CE method was used to compare metabolome content of cell extract derived from two different culture media containing either glucose or malate as a carbon source. The changes in carboxylic acid metabolites profile were observed depending from used culture medium. Carboxylic acid concentrations ranged: in cell extract from malate culture from 59 to 0.5 microM for lactate and citrate, respectively, and in cell extract from glucose culture from 133 to 0.5 microM for glutamate and citrate, respectively. Appropriate concentrations of carboxylic acid in the single bacterium cell were estimated at mM and sub-mM levels.
Dynamic pH junction is an on-line preconcentration method in capillary electrophoresis (CE) based on electrokinetic focusing of weakly ionic analytes with in large sample volumes in a multisection electrolyte system. In this report, experiments and computer simulations were performed to gain a better insight of the analyte focusing mechanism when a dynamic pH junction was used. A computer program, SIMUL, was used to simulate the band-narrowing process of a group for phenol derivatives under optimized buffer conditions, which were compared with experimental results. Computer simulations revealed the formation of a sharp moving pH boundary within the sample zone causing efficient focusing of long plugs of weakly acidic analytes based on their pKa. These studies offered useful information for understanding the band-narrowing process by control of the depth and lifetime of the moving pH boundary as a function of analyte pKa, sample pH, and injection length. The change in pH of the sample within the capillary was also estimated by measuring the absorbances of an analyte at two different wave-lengths. Optimization of analyte focusing resulted in enhanced detection responses of about 60-450-fold in terms of peak heights for some phenol derivatives' relation to conventional injections. Dynamic pH junction represents a novel approach to control band dispersion (peak width) and selectivity (mobility) of specific analytes for high-resolution CE separations.
Analysis of low concentrations of metabolites is required for new fields of biological research, such as metabolomics. In this review, recent work in our laboratory aimed at developing improved strategies for on-line sample preconcentration of metabolites by capillary electrophoresis (CE) is presented. Dynamic pH junction, sweeping and dynamic pH junction-sweeping represent three complementary methods for electrokinetic focusing of large volumes of sample directly on-capillary. Focusing selectivity and focusing efficiency are two factors that can be used to assess the suitability of each method for different classes of metabolites. Buffer properties can be selected to enhance the focusing of specific types of metabolites based on knowledge of the analyte physicochemical properties. The application of on-line preconcentration CE for trace analysis of metabolites in real samples of interest, such as biological fluids and cellular extracts, is also demonstrated. Under optimum conditions, up to three orders of magnitude increase in concentration sensitivity can be realized for several classes of metabolites, including catecholamines, purines, nucleosides, nucleotides, amino acids, steroids and coenzymes. Recent work on hyphenating on-line preconcentration with multiplexed CE is highlighted as a promising platform for sensitive and high-throughput analyses of metabolites.
With a growing interest in new areas of bioanalytical research such as metabolome analysis, the development of sensitive capillary electrophoresis (CE) methods to analyze sub-microM concentrations of analytes in biological samples is required. In this report, the application of CE with sweeping by borate complexation is used to analyze a group of seven pyridine and adenine nucleotide metabolites derived from bacteria Bacillus subtilis cell extracts. Nanomolar (nM) detectability of analytes by CE with UV photometric detection is achieved through effective focusing of large sample plug (approximately 10% of capillary length) using sweeping by borate complexation method, reflected by a limit of detections (S/N = 3) of about 2 x 10(-8) M. Changes in metabolites concentrations were observed in cell extracts when using either glucose or malate as the carbon source in the culture medium. Concentration of pyridine and adenine nucleotides in cell extracts varied widely from 78.6 (+/-7.6) microM for nicotinamide-adenine dinucleotide in malate to 0.66 (+/-0.12) microM for nicotinamide-adenine dinucleotide phosphate in glucose culture medium. Concentrations of metabolites in a single cell were also estimated at millimolar (mM) level. The method was validated in terms of linearity, sensitivity and reproducibility. The application of CE by sweeping borate complexation allows for sensitive and reproducible analyses of nucleotide metabolites in complex biological samples such as bacteria cell extracts.
Sensitive capillary electrophoresis (CE) methods are required for emerging areas of biochemical research such as the metabolome. In this report, dynamic pH junction-sweeping CE with laser-induced fluorescence (LIF) detection is applied as a robust single method to analyze trace amounts of three flavin derivatives, riboflavin, flavin mononucleotide (FMN), and flavin adenine dinucleotide (FAD), from several types of samples including bacterial cell extracts, recombinant protein, and biological fluids. Submicromolar amounts of flavin coenzymes were measured directly from formic acid cell extracts of Bacillus subtilis. Significant differences in flavin concentration were measured in cell extracts derived from either glucose or malate as the carbon source in the culture media. Quantitative assessment of FAD and FMN content from selected flavoenzymes was demonstrated after heat denaturation to release noncovalently bound coenzymes and deproteinization. This method was also applied to the analysis of free flavins in pooled human plasma and urine without the need for laborious off-line sample preconcentration. Picomolar detectability of flavins by CE-LIF detection was realized with on-line preconcentration (up to 15% capillary length used for injection) by dynamic pH junction-sweeping, resulting in a limit of detection (S/N = 3) of about 4.0 pM for FAD and FMN. This represents over a 60-fold improvement in concentration sensitivity compared to those of previous techniques using conventional injections. The method was validated in terms of reproducibility, sensitivity, linearity, and specificity. Flavin analysis by dynamic pH junction-sweeping CE-LIF offers a simple, yet sensitive way to analyze trace levels of flavin metabolites from complex biological samples.
On-line preconcentration by sweeping in micellar electrokinetic chromatography using mixed micelles of sodium dodecyl sulfate (SDS)-SB-12 is presented. Because of their large micelle radius, they permit increased partitioning of hydrophobic analytes into the core. In addition, they also possess lower negative surface charge relative to pure SDS micelles so anionic analytes can be retained better due to decreased electrostatic repulsion. As the efficiency of sweeping is predicated on the magnitude of retention factors, these advantages translated to better focusing. As much as a 370-fold improvement in detector response, in terms of peak height, was obtained for some neutral steroids, while about a 360-fold improvement was obtained for some phenol derivatives, which were previously not amenable to sweeping by pure SDS micelles.
This review provides an overview as well as a practical understanding of on-line sample concentration techniques in micellar electrokinetic chromatography (MEKC). MEKC as well as other capillary electrophoretic modes suffer from low concentration sensitivity due to minute sample volume and limited optical pathlength for on-capillary photometric detection. Two on-line sample preconcentration techniques, sample stacking and sweeping are known to be effective techniques for enhancement of the concentration sensitivity in MEKC. Sample stacking occurs as ions cross a boundary that separates regions of the high electric field sample zone and the low electric field background solution zone. The difference in migration velocity of pseudostationary phases within the two zones is the key to achieving the focusing effect. Sweeping is defined as the picking and accumulating of analytes by the pseudostationary phase that penetrates the sample zone devoid of pseudostationary phase. In this review, several examples of the sample stacking and sweeping under different experimental conditions are given, besides many references to applications.
Enantioselective separation of triadimenol, a component of systemic agricultural fungicide, by electrokinetic chromatography (EKC) using cyclodextrins (CDs) as chiral selectors was investigated. Both a neutral CD derivative, hydroxypropyl-gamma-CD (HP-gamma-CD), and an ionic one, heptakis-6-sulfato-beta-CD (HS-beta-CD), were employed as an additive in cyclodextrin-modified micellar electrokinetic chromatography (CD-MEKC) and as a chiral pseudostationary phase in CDEKC, respectively. In each system, four stereoisomeric peaks were completely or partially separated from each other. To enhance the detectability or the concentration sensitivity, on-line preconcentration techniques were applied to both EKC systems. Sweeping was used in the CD-MEKC system under an acidic condition, whereas stacking with a reverse migrating pseudostationary phase (SRMP) in the CDEKC system. Around 10-fold increase in the detection sensitivity for each peak was attained with both sweeping and SRMP systems. Good repeatabilities in the migration time, corrected peak area, and peak height were recognized in terms of the relative standard deviation. The limit of detection for each peak in the SRMP-CDEKC system, calculated from the calibration curve, was found to be 0.8-3.8 ppm.
A simple and inexpensive approach to modify a commercial atmospheric pressure chemical ionization (APCI) interface was proposed for capillary electrophoresis-mass spectrometry (CE-MS). In order to accommodate lower flow rates in the range 1-10 microl/min, both sheath liquid and nebulizing gas were coaxially supplied to the nebulizer as an arrangement of pneumatically assisted electrospray interface. Since this paper focused on the primary study of the modified APCI interface, the performance of the interface was first evaluated by the direct infusion of a reserpine solution. Optimization of several APCI parameters, such as temperature of APCI vaporizer, nebulizing gas flow and APCI corona discharge current, were accomplished. The orifice dimension for the nebulizing gas flow was largely independent of the MS sensitivity when the nebulizing gas flow rate was ca. 0.4 l/min. A successful CE-APCI-MS separation is obtained using the modified APCI interface.
Signal denoising and baseline correction using discrete wavelet transform (DWT) are described for microchip capillary electrophoresis (MCE). DWT was performed on an electropherogram describing a separation of nine tetramethylrohodamine-5-isothiocyanate labeled amino acids, following MCE with laser-induced fluorescence detection, using Daubechies 5 wavelet at a decomposition level of 6. The denoising efficiency was compared with, and proved to be superior to, other commonly used denoising techniques such as Fourier transform, Savitzky-Golay smoothing and moving average, in terms of noise removal and peak preservation by directly visual inspection. Novel strategies for baseline correction were proposed, with a special interest in baseline drift that frequently occurred in chromatographic and electrophoretic separations.
A micellar electrokinetic chromatography (MEKC) method was developed for estimating the angiotensin-I converting enzyme (ACE) inhibitory activity by separating the hippuric acid liberated in the ACE reaction mixture in the presence of an inhibitor, captopril. The hippuric acid was successfully separated and detected by MEKC with a 25 mM sodium dodecyl sulfate solution in a 25 mM phosphate-50 mM borate buffer at pH 7.0; the total analysis took about 5 min. A good linear relationship was observed between the inhibitor and the peak area of hippuric acid release. No significant difference in the ACE inhibitory activity (IC50) of captopril (an antihypertensive medicine) or autolyzed-mushrooms (functional foods) was observed between the conventional method and the MEKC method. The MEKC method was found to be a useful technique for a rapid assay of the ACE inhibitory activity.