PubMed Health⌕ Search

Biomedical subjects

Shigeru Terabe

Publications and source records attributed to Shigeru Terabe.

49 records · Page 3Linked to original sources

Sensitive and high-throughput analyses of purine metabolites by dynamic pH junction multiplexed capillary electrophoresis: a new tool for metabolomic studies.

On-line sample preconcentration by a dynamic pH junction in conjunction with multiplexed capillary electrophoresis (CE) and UV detection represents a sensitive and high-throughput format for future metabolomic research, such as purine analysis. The optimization of purine focusing can be rapidly assessed by systematically altering the sample matrix properties, such as the buffer co-ion, pH and ionic strength using a 96-capillary array format. This method permits focusing of large sample injection volumes, resulting in over a 50-fold improvement in the concentration sensitivity. The limit of detection (S/N = 3) for purine metabolites was less than 8.0 x 10(-8) M under optimum conditions when using UV absorbance. Dynamic pH junction multiplexed CE demonstrated excellent linearity over a hundred-fold concentration range, as well as low inter-capillary precision in terms of normalized migration times and peak areas. The potential for clinically relevant high-throughput analyses of micromolar amounts of purine metabolites in urine was also demonstrated.

Electrophoresis, Capillary↗

Separation and on-line concentration of bisphenol A and alkylphenols by micellar electrokinetic chromatography with cationic surfactant.

The separation and on-line concentration of bisphenol A and three alkylphenols were investigated by micellar electrokinetic chromatography with cationic surfactant. Tetradecyltrimethylammonium bromide was used as surfactant and the separation conditions were optimized by the addition of the organic solvents and cyclodextrins to the running solution. The separation of hydrophobic analytes and 4-nonylphenol isomers was improved by the addition of 20% acetonitrile and 20 mM beta-cyclodextrin to the running solution. When the sweeping with the running solution used as the on-line concentration procedure, 56-, 67- and 29-fold increase in detection sensitivity of bisphenol A, 4-tert.-butylphenol and 4-(1,1,3,3-tetramethylbutyl)phenol, respectively. The detection limits were 0.030, 0.098 and 0.159 mg/l, respectively.

Benzhydryl Compounds↗

On-line sample preconcentration in micellar electrokinetic chromatography using ion-pair reagents.

To improve the detection sensitivity of some aromatic carboxylic acids and naphthalenesulfonic acids, the use of ion-pair reagents was examined in sweeping micellar electrokinetic chromatography (MEKC) with an anionic sodium dodecyl sulfate (SDS) micelle. Tetraalkylammonium (TAA) salts were used as ion-pair reagents to improve the sweeping efficiency. The effects of the alkyl chain length of the TAA groups and the TAA salt concentration on sweeping were examined. Under optimized conditions, about 400-fold enhancement in detection sensitivity was obtained in terms of peak heights by addition of ion-pair reagents in sweeping MEKC. This value was about 10 times greater than that obtainable by the SDS micelle used alone.

Carboxylic Acids↗

Sweeping: concentration mechanism and applications to high-sensitivity analysis in capillary electrophoresis.

Sweeping in capillary electrophoresis (CE) involves the interaction of a pseudostationary phase (PS) in the separation solution and a sample in the matrix that is free of the PS used. The PS includes not only the PSs employed in electrokinetic chromatography, but also complexation reagents such as borate. The sample matrix could have a lower, similar, or higher conductance than the separation solution. Thus, the basic condition for sweeping is a sample matrix free of the additive. The accumulation of analyte molecules during the interaction makes this interesting phenomenon very useful as an on-line preconcentration method for CE. Preconcentration occurs due to chromatographic partitioning, complexation, or any interaction between analytes and PS. Contact between analyte and PS is facilitated by the action of electrophoresis and is independent of electroosmosis. The analyte, PS, or both should have electrophoretic velocities when an electric field is applied. The extent of preconcentration is dictated by the strength of the interaction involved. From tens to several thousand-fold improvements in detector response for many neutral and charged analytes have been achieved with this technique, suggesting sweeping as a general approach to on-line preconcentration in CE. The mechanism and applications of the sweeping phenomenon under different experimental conditions are discussed in this review, with particular emphasis on a better understanding of the sweeping mechanism under reduced electric field (high conductivity) in the sample zone.

Electrophoresis, Capillary↗

On-line focusing of flavin derivatives using Dynamic pH junction-sweeping capillary electrophoresis with laser-induced fluorescence detection.

Simple yet effective methods to enhance concentration sensitivity is needed for capillary electrophoresis (CE) to become a practical method to analyze trace levels of analytes in real samples. In this report, the development of a novel on-line preconcentration technique combining dynamic pH junction and sweeping modes of focusing is applied to the sensitive and selective analysis of three flavin derivatives: riboflavin, flavin mononucleotide (FMN) and flavin adenine dinucleotide (FAD). Picomolar (pM) detectability of flavins by CE with laser-induced fluorescence (LIF) detection is demonstrated through effective focusing of large sample volumes (up to 22% capillary length) using a dual pH junction-sweeping focusing mode. This results in greater than a 1,200-fold improvement in sensitivity relative to conventional injection methods, giving a limit of detection (S/N = 3) of approximately 4.0 pM for FAD and FMN. Flavin focusing is examined in terms of analyte mobility dependence on buffer pH, borate complexation and SDS interaction. Dynamic pH junction-sweeping extends on-line focusing to both neutral (hydrophobic) and weakly acidic (hydrophilic) species and is considered useful in cases when either conventional sweeping or dynamic pH junction techniques used alone are less effective for certain classes of analytes. Enhanced focusing performance by this hyphenated method was demonstrated by greater than a 4-fold reduction in flavin bandwidth, as compared to either sweeping or dynamic pH junction, reflected by analyte detector bandwidths <0.20 cm. Novel on-line focusing strategies are required to improve sensitivity in CE, which may be applied toward more effective biochemical analysis methods for diverse types of analytes.

Coenzymes↗

Selective detection of biogenic amines using capillary electrochromatography with an on-column derivatization technique.

A selective detection method for biogenic amines present in highly complex matrixes was devised by employing both electrokinetic injection and on-column-derivatization capillary electrochromatographic methods. The on-column derivatization capillary electrochromatography system was evaluated by use of a capillary column (total length of 45 cm, effective length of 25 cm) fabricated using a 100-mcirom (i.d.) fused-silica capillary tube packed with 5-microm (i.d.) ODS particles that were tolerant of an alkaline environment. The column was filled with a run buffer consisting of a derivatization reagent, o-phthalaldehyde/2-mercaptoethanol, in a mixture of borate buffer (pH 10). After electrokinetic injection of a mixture of five biogenic amines (histamine, serotonin, tyramine, putrescine, cadaverine) as a test sample, the free amines entered into the anodic site of the capillary column and started to travel along the column, during which time the analytes reacted with the derivatization reagent, separated out, and were detected with an absorbance at 340 nm when high voltage was applied to the column. When this system was applied to a mixture containing 5 biogenic amines and 17 amino acids, the 5 biogenic amines plus arginine selectively entered into the capillary with the electrokinetic injection and were observed on the electrochromatogram, but none of the amino acids lacking arginine were detected. The designated method was also tested for its ability to determine the presence of biogenic amines in the crude extracts obtained from two types of aged fish.

Acetonitriles↗

Evaluation of extended light path capillary and etched capillary for use in open tubular capillary electrochromatography.

Poor sensitivity and low phase ratio are the main drawbacks of open tubular capillary electrochromatography (OTCEC). The poor sensitivity results from the use of narrow bore size capillary, whereas the low phase ratio, which limits the separation capability, is caused by the limited surface area of conventional capillary. Two strategies may be useful to overcome these disadvantages. First, an extended light path (ELP) capillary, which has a bubble cell at the detection point, is used to improve the sensitivity. Secondly, an etched capillary of a 1,000-fold increased surface area is used to enhance the phase ratio. In this work, use of an ELP capillary and an etched capillary in OTCEC was evaluated with a chiral stationary phase of avidin prepared with the physical adsorption method. With a 20 microm I.D. ELP capillary with a 150 microm bubble cell, the peak height was enhanced by 4-10-fold and the corrected peak area was increased by 12-fold relative to a 20 microm I.D. conventional capillary. However, the peak efficiency and resolution decreased noticeably. The phase ratio on the etched capillary was slightly enhanced, by a factor of 1.64 relative to an unetched capillary. Consequently, the separation capability was slightly improved. The increase in the phase ratio was much lower than that expected from the increase in surface area, the reason for which is probably the reduced density of surface silanol group and the generation of nitrogen-containing groups due to the etching process.

Adsorption↗

Analysis of the herbicides paraquat, diquat and difenzoquat in drinking water by micellar electrokinetic chromatography using sweeping and cation selective exhaustive injection.

Optimum conditions for the determination of the herbicides paraquat, diquat and difenzoquat by micellar electrokinetic chromatography (MEKC) using sweeping and cation-selective exhaustive injection (CSEI) as on-line concentration methods were developed. Sodium dodecyl sulfate (80 mM) in 50 mM phosphate buffer (pH 2.5) with 20% acetonitrile was used as a background electrolyte for the methods studied. The limits of detection, based on a signal-to-noise ratio of 3:1, were about 2.6-5.1 mg 1(-1) in purified water when MEKC was applied for the standards. By using an on-line preconcentration method known as sweeping-MEKC, up to a 500-fold increase in detection sensitivity was obtained whereas up to a 50 000-fold increase for CSEI-sweeping-MEKC was achieved. The limits of detection using optimum CSEI-sweeping-MEKC were lower than 1 microg 1(-1) and the method was validated obtaining good reproducibility (relative standard deviation lower than 22%) and linearity. CSEI-sweeping-MEKC was successfully applied to the determination of the three herbicides in spiked tap water below the levels established by the US Environmental Protection Agency.

Cations↗

Modeling of retention behavior in capillary electrochromatography from chromatographic and electrophoretic data.

A phenomenological approach was presented to describe the retention behaviors of solutes in capillary electrochromatography (CEC). Equations for calculation of the retention time and actual chromatographic retention factor for ionic solutes, weak monoprotic acid and weak monoprotic base were derived, which can be described by two general expressions regardless the charge status of the solute. The general expressions enable calculation of the retention time and retention factor in CEC from chromatographic and electrophoretic data, which were experimentally verified with a variety of compounds and a variety of CEC modes. Based on this approach, the chromatographic retention and the electrophoretic migration in the CEC systems studied were found to be two independent processes. The validity of this approach was also discussed.

Chromatography, Micellar Electrokinetic Capillary↗

Thermal unfolding of proteins studied by coupled reversed-phase HPLC-electrospray ionization mass spectrometry techniques based on isotope exchange effects.

In this study, a deuterium exchange procedure has been employed to evaluate the thermal stability of globular proteins under conditions that replicate their interactive behavior in reversed-phase high performance chromatographic (RP-HPLC) systems. In particular, this investigation has permitted the conformational stability of two proteins, hen egg white lysozyme (HEWL) and horse heart myoglobin (HMYO) to be examined under different temperature and low-pH solvent regimes. The results confirm that this experimental approach provides an efficient strategy to explore fundamental conformational features of polypeptides or proteins in their folded and partial unfolded states under these interactive conditions. In particular, this analytical procedure permits insight to be readily gained into the processes that occur when polypeptides and globular proteins interact with lipophilic liquid/ solid interfaces in the presence of water-organic solvent mixtures at different temperatures.

Animals↗

Estimation of binding constants by capillary electrophoresis.

Capillary electrophoresis (CE) has become a useful technique for measuring binding constants. This review is focused on recent trends in the estimation of binding constants by affinity CE. First, we introduce several mathematical equations in which it is assumed that the stoichiometry of the binding between drug and protein is 1:1 as a simple model. In order to calculate accurate binding constants by affinity CE, several experimental considerations are described in this review. In addition, some recent methodologies, such as partial filling technique and multiple-step ligand injection method, are introduced. Among research publications within 3 years, recent applications for determining binding constants are reviewed.

Electrophoresis, Capillary↗

Physically adsorbed chiral stationary phase of avidin on monolithic silica column for capillary electrochromatography and capillary liquid chromatography.

The physical adsorption method proposed previously has been successfully applied to a monolithic silica column. By virtue of the physical adsorption, a chiral stationary phase of avidin was prepared onto the silica monolith. The phase ratio of resulting stationary phase was evaluated with frontal analysis. The method proved to be comparable in phase ratio to the chemical bonding methods used in high-performance liquid chromatography (HPLC). Enantiomer separations were carried out in capillary electrochromatography (CEC) and capillary liquid chromatography (CLC) modes. Due to its larger phase ratio, the resulting column showed more powerful separation capability as compared to open-tubular CEC (OTCEC). Twelve chiral compounds were baseline-resolved. The resulting column showed high separation efficiency, with average theoretical plate numbers of 66 000/m for CLC and 122 000/m for CEC. Good reproducibility was observed, with RSD value less than 1.3% for retention time, retention factor and separation factor, and less than 6.6% for plate counts and resolution (n = 40). Fast separations were achieved with a short column. The test enantiomers were baseline-resolved within 4 min under CLC and CEC modes. In addition, field-enhanced sample injection (FESI) was coupled to CLC as well as CEC to improve the detection sensitivity.

Adsorption↗

High-sensitivity analyses of metabolites in biological samples by capillary electrophoresis using dynamic pH junction-sweeping.

Emerging fields of biochemical research, such as metabolomics, present challenges to current separation technologies because of the large number of metabolites present in a cell and their often low (submicromolar) concentration. Although capillary electrophoresis (CE) holds great promise as the method of choice for high-resolution separations of biological samples, it suffers from poor concentration sensitivity, especially with the use of UV detection. In CE, sweeping and dynamic pH junction represent two complementary on-line focusing techniques that have been used for sensitivity enhancement of hydrophobic and weakly acidic analytes, respectively. However, the application of either the sweeping or dynamic pH junction technique alone might, in some cases, be less effective for the analysis of certain sample mixtures. Recent work in the development of a hyphenated dynamic pH junction-sweeping technique is presented as an effective on-line method of preconcentration suitable for both hydrophilic (anionic) and hydrophobic (neutral) analytes. Sensitive analyses of flavin metabolites by CE with laser-induced fluorescence (LIF) detection is demonstrated in various biological matrixes, including cell extracts of Bacillus subtilis, pooled human plasma, as well as heat-deproteinized flavoenzymes. Enhanced analyte band narrowing and improved sensitivity is achieved for flavins using dynamic pH junction-sweeping compared to either sweeping or dynamic pH junction alone. This results in over a 1200-fold improvement in sensitivity relative to conventional injection methods, giving a limit of detection (LOD, defined as S/N = 3) of about 4.0 x 10(-12) M. Strategies for sensitive and more comprehensive analyses of other cell metabolites, including nucleotides, coenzymes, and steroids, are also discussed when using on-line focusing techniques in conjunction with multiplexed CE and UV detection.

Bacillus subtilis↗