PubMed Health⌕ Search

Biomedical subjects

Shoko Nioka

Publications and source records attributed to Shoko Nioka.

20 records · Page 2Linked to original sources

Effect of errors in baseline optical properties on accuracy of transabdominal near-infrared spectroscopy in fetal sheep brain during hypoxic stress.

A continuous-wave (cw) near-infrared spectroscopy (NIRS) instrument has been developed to noninvasively quantify fetal cerebral blood oxygen saturation (StO2). A linear Green's function formulism was used to analytically solve the photon diffusion equation and extract the time-varying fetal tissue oxy- and deoxy-hemoglobin concentrations from the NIR measurements. Here we explored the accuracy with which this instrument can be expected to perform over a range of fetal hypoxic states. We investigated the dependence of this accuracy on the accuracy of the reference optical properties chosen based on the literature. The fetal oxygenation of a pregnant ewe model was altered via maternal aortic occlusion. The NIR cw instrument was placed on the maternal abdomen directly above the fetal head, continuously acquiring diffuse optical measurements. Blood was sampled periodically from the fetus to obtain fetal arterial saturation (SaO2) measurements from blood gas analysis. The NIR StO2 values were compared with the fetal SaO2 measurements. Variations in the NIR results due to uncertainty in the reference optical properties were relatively small within the fetal SaO2 range of 30 to 80%. Under hypoxic conditions, however, the variability of the NIR StO2 calculations with changes in the assumed reference properties became more significant.

Abdomen↗

Noninvasive diffuse optical measurement of blood flow and blood oxygenation for monitoring radiation therapy in patients with head and neck tumors: a pilot study.

This pilot study explores the potential of noninvasive diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS) for monitoring early relative blood flow (rBF), tissue oxygen saturation (StO(2)), and total hemoglobin concentration (THC) responses to chemo-radiation therapy in patients with head and neck tumors. rBF, StO(2), and THC in superficial neck tumor nodes of eight patients are measured before and during the chemo-radiation therapy period. The weekly rBF, StO(2), and THC kinetics exhibit different patterns for different individuals, including significant early blood flow changes during the first two weeks. Averaged blood flow increases (52.7+/-9.7)% in the first week and decreases (42.4+/-7.0)% in the second week. Averaged StO(2) increases from (62.9+/-3.4)% baseline value to (70.4+/-3.2)% at the end of the second week, and averaged THC exhibits a continuous decrease from pretreatment value of (80.7+/-7.0) [microM] to (73.3+/-8.3) [microM] at the end of the second week and to (63.0+/-8.1) [microM] at the end of the fourth week of therapy. These preliminary results suggest daily diffuse-optics-based therapy monitoring is feasible during the first two weeks and may have clinical promise.

Aged↗