A novel method to measure regional muscle blood flow continuously using NIRS kinetics information.

BACKGROUND: This article introduces a novel method to continuously monitor regional muscle blood flow by using Near Infrared Spectroscopy (NIRS). We demonstrate the feasibility of the new method in two ways: (1) by applying this new method of determining blood flow to experimental NIRS data during exercise and ischemia; and, (2) by simulating muscle oxygenation and blood flow values using these newly developed equations during recovery from exercise and ischemia. METHODS: Deoxy (Hb) and oxyhemoglobin (HbO2), located in the blood of the skeletal muscle, carry two internal relationships between blood flow and oxygen consumption. One is a mass transfer principle and the other describes a relationship between oxygen consumption and Hb kinetics in a two-compartment model. To monitor blood flow continuously, we transfer these two relationships into two equations and calculate the blood flow with the differential information of HbO2 and Hb. In addition, these equations are used to simulate the relationship between blood flow and reoxygenation kinetics after cuff ischemia and a light exercise. Nine healthy subjects volunteered for the cuff ischemia, light arm exercise and arm exercise with cuff ischemia for the experimental study. RESULTS: Analysis of experimental data of both cuff ischemia and light exercise using the new equations show greater blood flow (four to six times more than resting values) during recovery, agreeing with previous findings. Further, the simulation and experimental studies of cuff ischemia and light exercise agree with each other. CONCLUSION: We demonstrate the accuracy of this new method by showing that the blood flow obtained from the method agrees with previous data as well as with simulated data. We conclude that this novel continuous blood flow monitoring method can provide blood flow information non-invasively with NIRS.

Journal Article↗

Skeletal muscle energetics with PNMR: personal views and historic perspectives.

This article reviews historical and current NMR approaches to describing in vivo bioenergetics of skeletal muscles in normal and diseased populations. It draws upon the first author's more than 70 years of personal experience in enzyme kinetics and the last author's physiological approaches. The development of in vivo PNMR jointly with researchers around the world is described. It is explained how non-invasive PNMR has advanced human exercise biochemistry, physiology and pathology. Further, after a brief explanation of bioenergetics with PNMR on creatine kinase, anerobic glycolysis and mitochondrial oxidative phosphorylation, some basic and controversial subjects are focused upon, and the authors' view of the subjects are offered, with questions and answers. Some of the research has been introduced in exercise physiology. Future directions of NMR on bioenergetics, as a part of system biological approaches, are indicated.

Adenosine Triphosphate↗

Simulation study of breast tissue hemodynamics during pressure perturbation.

We simulated the effects of compression of the breast on blood volume and tissue oxygenation. We sought to answer the question: how does the compression during breast examination impact on the circulatory systems of the breast tissue, namely blood flow, blood pooling, and oxygen concentration? We assumed that the blood was distributed in two compartments, arterial and venous. All the parameters were expressed with oxy- and deoxyhemoglobin quantities and were measured with a non-invasive method, Near Infrared Spectroscopy (NIRS). The simulated data showed that the blood volume pool in the breast decreased due to lower arterial flow and higher venous outflow, as the breast was squeezed under 100 cm H2O with a 10 cm diameter probe (or 78 cm2). The blood volume was reversed when the pressure was released. The breast venous oxygen saturation dropped, but overall tissue saturation (presenting NIRS signal, volume weighted average saturation) was increased. The results showed that simulation can be used to obtain venous and average oxygen saturation as well as blood flow in compressed breast tissues.

Blood Volume↗

Mitochondrial NADH as the bellwether of tissue O2 delivery.

It is proposed that the redox state of mitochondrial NADH will complement blood gas analysis for measuring the health and welfare of human tissues. Use of arterial oxygen saturation levels (SaO2), especially as assayed by the Nellcor instrument, has spread almost everywhere in medicine despite the fact that hypoxia of internal organs, liver, kidney, brain, pancreas, etc. is not well indicated by peripheral digital oxygenation. Indeed, there is an implied liability in the failure to infer central oxygenation from peripheral values. Near infrared (NIR) sensing of deep tissue saturation of hemoglobin (StO2) requires multi-wavelength, multi-site measurement of both absorption and scattering properties by time or frequency domain NIR methods. Corrections for underlying water and lipid absorptions can be made so that the correct value for, and saturation oh hemoglobin are obtained. Nevertheless, the significance of blood oxygen saturation, even localized to particular organs, can be questioned from the standpoint of what is the critical value of the desaturation from which the tissue can recover; for example, in the case of cortical neurons where stroke, compression ischemia, etc. cause O2 lack, this value becomes of significant clinical importance in both the brain and the spinal chord. These approaches are actively pursued and the possibility of subsurface redox state measurement in human tissues may eventually emerge as the quantitative metric of tissue metabolic state and of hypoxic stress. The great flexibility and versatility of the fast, economical and "tetherless" nature of opto-electronic technology is appropriate to the manifold challenges of neuronal function as currently measured by intrinsic signals and soon to be studiable by extrinsic signals of metabolism and electrophysiological functions.

Animals↗

Breast cancer detection based on incremental biochemical and physiological properties of breast cancers: a six-year, two-site study.

RATIONALE AND OBJECTIVES: To demonstrate that near-infrared spectroscopy would achieve sufficient sensitivity and specificity in human breast cancer to reach ROC/AUC values in the 90s and yet to warn of the potential liabilities of introduction of a novel technology in this field. MATERIALS AND METHODS: 116 subjects from two nations (44 were cancer-verified by biopsy and histopathology) were reviewed. NIR spectroscopy of total hemoglobin and its relative oxygenation were monitored in breast cancers and compared to their contralateral breast in a 2D nomogram for diagnostic evaluation. A novel handheld NIR breast cancer detector pad with a 3-wavelength LED and 8 detectors with 4 cm separation between source and detectors was placed on the subject's breast. The method is convenient, rapid, and safe and has achieved high patient compliance with minimal patient apprehension of compression, confinement, or radioactivity. RESULTS: The absorbance increments of the cancerous region are referred to the mirror image location on the contralateral breast. The two metrics are increased hemoglobin concentration due to angiogenesis and decreased hemoglobin saturation due to hypermetabolism of the cancer. The 2D nomogram display of these two metrics shows Zone 1 contains verified cancers and Zone 2 contains noncancers. ROC evaluation of the nomogram gives 95% AUC for the two sites, Philadelphia and Leipzig. CONCLUSION: A simple, economical breast cancer detector has achieved high patient compliance and a high ROC/AUC score for a population which involved a range of tumors down to and including those of 0.8-1 cm in diameter.

Area Under Curve↗

Transabdominal fetal pulse oximetry with near-infrared spectroscopy.

OBJECTIVE: The purpose of this study was to determine the feasibility of noninvasive fetal pulse oximetry in the human fetus with transabdominal continuous-wave near-infrared spectroscopy. STUDY DESIGN: The instrument has 3 wavelength light-emitting diodes (735, 805, and 850 nm) as light sources and a photomultiplier tube as a detector. This instrument was used in 6 pregnant women (>36 weeks of gestation). First, a fetal heart rate was obtained with a fetal heart rate monitor. Then, the depth of fetal tissue (head) from the maternal abdomen was determined by ultrasound examination; the distance between the optodes (light source and the detector) was set to be approximately twice the depth of the fetus (7-11 cm). The data analysis was based on the modified Beer-Lambert law and the use of optical densities at 735 and 850 nm to obtain the concentration changes of the oxyhemoglobin and deoxyhemoglobin. The saturation was expressed as the percent of oxygen saturation equal to 100 x oxyhemoglobin/(oxyhemoglobin + deoxyhemoglobin). We recorded the spectroscopy data and the fetal heart rate for approximately 3 to 10 minutes in each patient. RESULTS: The mean oxygen saturation values of each of the 6 individual fetuses ranged from 50% to 74% (overall mean saturation, 61% +/- 14.8% [SD]). CONCLUSION: This preliminary data indicate that transabdominal fetal pulse oximetry is feasible for human patient application. The measured values were similar to those that are obtained with transvaginal pulse oximetry. Future studies should correlate transabdominally obtained measurements with those measurements that are obtained by transvaginal fetal pulse oximetry.

Abdomen↗

Fetal transabdominal pulse oximeter studies using a hypoxic sheep model.

OBJECTIVE: This study investigates the validity of transabdominal pulse oximetry using a sheep fetal hypoxia model with fetal arterial hemoglobin saturation. METHODS: Four pregnant ewes were anaesthetized and cannulated through the brachial artery to measure direct arterial blood saturation, SaO(2). Next, the transabdominal pulse oximeter was used to measure indirect measurement of the arterial saturation of the fetus, SpO(2), from the maternal abdomen. Hypoxia was induced by a balloon placed in the maternal aorta. RESULTS: There is a linear relationship between SaO(2), arterial blood saturation values of the fetus, and SpO(2), the values measured by the transabdominal pulse oximetry with a slope of 0.75 (r(2)=0.76). CONCLUSION: This information can be used to calibrate the transabdominal pulse oximeter as a measurement of fetal arterial saturation. With these results, we can advance the accurate, no-risk, noninvasive transabdominal fetal pulse oximeter for human use. This research may contribute to the more accurate diagnosis of the diseases of the fetus including Hypoxic Ischemic Encephalopathy.

Abdomen↗

Reduced heterogeneity of muscle deoxygenation during heavy bicycle exercise.

PURPOSE: This study evaluated heterogeneity of muscle O2 dynamics in a single muscle during bicycle exercise using an eight-channel near-infrared continuous wave spectroscopy (NIRcws) mapping system. METHODS: Nine healthy subjects performed bicycle exercise at fixed workloads of 20, 40, 60, 80, and 100% maximal workload for 5 min at each level. Muscle oxygenation in the vastus lateralis (VL) during and after each exercise was monitored using the NIRcws mapping system. Pulmonary O2 uptake and heart rate were monitored continuously during the experiment. Blood samples were taken to measure blood lactate concentration at 30 s after each exercise stage. RESULTS: Half time reoxygenation, the time taken to reach a value of half-maximal recovery, was significantly delayed in distal sites compared with proximal sites of VL. Conversely, muscle deoxygenation for all measurement sites increased incrementally with higher exercise workloads, and no significant difference of deoxygenation level showed within each channel. However, relative dispersion of muscle deoxygenation during exercise significantly decreased when the workload increased. Moreover, relative dispersion of muscle deoxygenation between the subjects also decreased with an increase in the workload. CONCLUSION: Muscle deoxygenation in a single muscle was more heterogeneous at lower exercise workloads, and variations of the muscle deoxygenation heterogeneity between subjects were greater at lower exercise workloads.

Adult↗

Evaluation of physiological responses during recovery following three resistance exercise programs.

The present study was conducted to examine (a) whether there is an association between maximal oxygen uptake (Vo(2)max) and reduction in postexercise heart rate (HR) and blood lactate concentrations ([La]) following resistance exercise and (b) how intensity and Volume of resistance exercise affect postexercise Vo(2). Eleven regularly weight-trained males (20.8 +/- 1.3 years; 96.2 +/- 14.4 kg, 182.4 +/- 7.3 cm) underwent 4 sets of squat exercise on 3 separate occasions that differed in both exercise intensity and volume. During each testing session, subjects performed either 15 repetitions.set(-1) at 60% of 1 repetition maximum (1RM) (L), 10 repetitions.set(-1) at 75% of 1RM (M), or 4 repetitions.set(-1) at 90% of 1RM (H). During each exercise, Vo(2) and HR were measured before (PRE), immediately post (IP), and at 10 (10P), 20 (20P) 30 (30P), and 40 (40P) minutes postexercise. The [La] was measured at PRE, IP, 20P, and 40P. Decrease in HR (DeltaHR) was determined by subtracting HR at 10P from that at IP, whereas decrease in [La] (Delta[La]) was computed by subtracting [La] at 20P from that at IP. A significant correlation (p < 0.05) was found between Vo(2)max and DeltaHR in all exercise conditions. A significant correlation (p < 0.05) was also found between Vo(2)max and Delta[La] in L and M but not in H. The Vo(2) was higher (p < 0.05) during M than H at IP and 10P, while no difference was seen between L and M and between L and H. These results indicate that those with greater aerobic capacity tend to have a greater reduction in HR and [La] during recovery from resistance exercise. In addition, an exercise routine performed at low to moderate intensity coupled with a moderate to high exercise volume is most effective in maximizing caloric expenditure following resistance exercise.

Adaptation, Physiological↗

The effect of a competitive collegiate football season on power performance and muscle oxygen recovery kinetics.

Ten intercollegiate football players were tested within 3 days prior to (T1) and the day following the end (T2) of football preseason training camp and during weeks 7 (T3) and 11 (T4) of the competitive season. During each testing session, subjects performed a 30-second Wingate anaerobic power test. Near-infrared continuous wave spectroscopy was used to measure muscle deoxygenation during exercise. No changes in any power performance measures were seen during the competitive football season. A significant (p < 0.05) decrease in the extent of deoxygenation during exercise was observed between T2 (72.6 +/- 19.4%) and T4 (50.2 +/- 14.2%). A 30 and 29% difference (p < 0.05) in the onset of reoxygenation was observed between T1 and T3 and T4, respectively. A 51% decrease (p < 0.05) in halftime recovery was observed between T2 and T3. Results indicate that the extent of muscle deoxygenation is reduced during high-intensity exercise and that muscle oxygen recovery kinetics improves over the duration of a competitive season of football.

Adult↗

Relationship between muscle architectural features and oxygenation status determined by near infrared device.

This study tested whether regional differences in oxygenation status could result from differences in muscle fiber architecture. Architectural properties, oxygen supply, and consumption in the medial head of the gastrocnemius muscle (GM) were determined in vivo in six men using B-mode ultrasound and functional near infrared (NIR) imaging devices. Fascicle length, fascicle angle, NIR-O(2) saturation (deoxygenated Hb or oxygenated Hb), and NIR-blood volume (sum of deoxygenated and oxygenated Hb) were obtained in the distal and proximal portions of the GM at rest and during contraction. Exercise consisted of 2 min of standing plantar flexion at 1 Hz with an additional load of 50% of each subject's weight. Plantar flexion produced larger decreases (Delta: difference between rest and exercise values) in NIR-O(2) saturation [mean saturation (SD) of 0.14 (0.05) vs 0.07 (0.04) optical density units] and NIR-blood volume [mean saturation (SD) of -0.23 (0.08) vs -0.13 (0.04) optical density units] in the distal compared with the proximal portion ( P<0.05 for all comparisons). It also produced larger changes (Delta) in fascicle length [mean length (SD) of -16.5 (4.7) vs -8.2 (4.2) mm] and fascicle angle (mean angle (SD) of 10.8 (1.4) degrees vs 3.9 (2.1) degrees ] in the distal compared with the proximal portion ( P<0.05 for all comparisons). There were significant correlations between DeltaNIR-O(2 )saturation and Deltafascicle length ( r=-0.84, P<0.05), and between DeltaNIR-O(2) saturation and Deltafascicle angle ( r=-0.90, P<0.05), between DeltaNIR-blood volume and Deltafascicle length ( r=0.91, P<0.05), between DeltaNIR-blood volume and Deltafascicle angle ( r=-0.85, P<0.05). In conclusion, the plantar flexion exercise produced regional differences in oxygenation status consistent with regional differences in muscle architecture.

Adult↗

Discrepancy between cardiorespiratory system and skeletal muscle in elite cyclists after hypoxic training.

BACKGROUND: The purpose of this study was to determine the effects of hypoxic training on the cardiorespiratory system and skeletal muscle among well-trained endurance athletes in a randomized cross-over design. METHODS: Eight junior national level competitive cyclists were separated into two groups; Group A trained under normoxic condition (21% O2) for 2 hours/day, 3 days/week for 3 weeks while Group B used the same training protocol under hypoxic condition (15% O2). After 3 weeks of each initial training condition, five weeks of self-training under usual field conditions intervened before the training condition was switched from NT to HT in Group A, from HT to NT in Group B. The subjects were tested at sea level before and after each training period. O2 uptake (O2), blood samples, and muscle deoxygenation were measured during bicycle exercise test. RESULTS AND DISCUSSION: No changes in maximal workload, arterial O2 content, O2 at lactate threshold and O2max were observed before or after each training period. In contrast, deoxygenation change during submaximal exercise in the vastus lateralis was significantly higher at HT than NT (p < 0.01). In addition, half time of oxygenation recovery was significantly faster after HT (13.2 PlusMinus; 2.6 sec) than NT (18.8 PlusMinus; 2.7 sec) (p < 0.001). CONCLUSIONS: Three weeks of HT may not give an additional performance benefit at sea level for elite competitive cyclists, even though HT may induce some physiological adaptations on muscle tissue level.

Journal Article↗

Quantitative brain tissue oximetry, phase spectroscopy and imaging the range of homeostasis in piglet brain.

The quantification of tissue oxygen by frequency or time domain methods has been discussed in a number of prior publications where the meaning of the tissue hemoglobin oxygen saturation was unclear and where the CW instruments were unsuitable for proper quantitative measurements [1, 2]. The development of the IQ Phase Meter has greatly simplified and made reliable the difficult determination of precise phase and amplitude signals from brain. This contribution reports on the calibration of the instrument in model systems and the use of the instrument to measure tissue saturation (StO2) in a small animal model. In addition, a global interpretation of the meaning of tissue oxygen has been formulated based on the idea that autoregulation will maintain tissue oxygen at a fixed value over a range of arterial and venous oxygen values over the range of autoregulation. Beyond that range, the tissue oxygen is still correctly measured but, as expected, approaches the arterial saturation at low metabolic rates and the venous saturation at high metabolic rates of mitochondria.

Animals↗

Oxygenation and blood concentration changes in human subject prefrontal activation by anagram solutions.

Continued studies in cognitive function in problem solving of graded difficulties has now proceeded through several thousand tests of high school students in a six-week period last summer (2000). The optical imager used 9 sources and 23 detectors operated in time multiplex to give an image of the prefrontal region in several seconds. Thus, the image can be acquired in the state prior to activation, during and following activation. The images are acquired at two wavelengths, 750 and 850 nm, from which the changes of blood concentration (blood pooling) and relative oxygenation/deoxygenation state (metabolic activity) can be obtained and with suitable calibrations converted into micromolar changes of total Hb concentration and fractional oxygenation, respectively. The imager has a wearable pad applied to the forehead and the electronics now presents the running average of the two quantities mentioned above in the 16 voxels which cover the prefrontal region in 1 sec. Thus the protocol involves a scanning through anagrams of graded difficulty which are known to include the range of maximal activation (>3 solutions in the 30 sec test interval or are too easy (>10), or too difficult. Anagrams are presented in a sequence of three, four, five, etc. letter anagrams to the maximal level of difficulty and then back down again to the starting point. Each anagram is displayed for approximately one minute. Computer scanning of the results gives histograms of the several hundred tests per individual in the "training" interval (for three weeks) and in the post training interval about 400 tests, each for 4 levels of difficulty (3 weeks). Usually two or three complete trials per day were achieved with the result that the group of 7 students produced over 2600 test results in 2000. The histogram displays are under study to determine: a) the most fruitful voxels, b) the fraction of the total tests that appeared in those voxels, and c) the maximum signal level observed in the histogram display in units of micromolar hemoglobin. The product of these two was taken as the Figure of Merit and their displays of the 16 voxels gave patterns for trained and untrained responses. The preliminary conclusions of this study were: a) that the training effect was very large, pretraining exhibited a chaotic voxel distribution for all difficulty levels while trained students gave a higher output and activated only one or two of the 16 voxels. If the tests were too easy, too hard, i.e., an ability/difficulty mismatch, frustration or disattention gave similar chaotic patterns (7); b) a match between difficulty and ability activated only a few voxels in similar locations. Since attention and success measures appear to be of interest in school room studies, a wearable imager with local LCD display can be supplied to the Senior class of the local high school for those individuals who have already had last Summer's training in anagrams. A wearable NIR measurement of metabolic activation and blood flow may be a useful educational aid. In summary, the optical method focuses attention on cognition activated oxygenation of prefrontal cortex.

Blood-Brain Barrier↗

In vivo continuous-wave optical breast imaging enhanced with Indocyanine Green.

We investigate the uptake of a nontargeted contrast agent by breast tumors using a continuous wave diffuse optical tomography apparatus. The instrument operates in the near-infrared spectral window and employs 16 sources and 16 detectors to collect light in parallel on the surface of the tumor-bearing breast (coronal geometry). In our protocol an extrinsic contrast agent, Indocyanine Green (ICG), was injected by bolus. Three clinical scenarios with three different pathologies were investigated. A two-compartment model was used to analyze the pharmacokinetics of ICG and preprocess the data, and diffuse optical tomography was used for imaging. Localization and delineation of the tumor was achieved in good agreement with a priori information. Moreover, different dynamical features were observed for differing pathologies. The malignant cases exhibited slower rate constants (uptake and outflow) compared to healthy tissue. These results provide further evidence that in vivo pharmacokinetics of ICG in breast tumors may be a useful diagnostic tool for differentiation of benign and malignant pathologies.

Adenocarcinoma↗

Effect of muscle oxygenation during resistance exercise on anabolic hormone response.

PURPOSE: The mechanisms that underlie the affect of acute program variables on muscle growth and strength development for strength/power athletes have been of great interest. This investigation examined the affects of two different resistance exercise protocols on muscle oxygenation, and the anabolic hormonal response to such exercise. METHODS: Eleven experienced resistance-trained male athletes performed four sets of the squat exercise using either a low-intensity, high-volume (LI; 15 repetitions at 60% one-repetition maximum [1-RM]) or high-intensity, low-volume (HI; 4 repetitions at 90% 1-RM) load. Venous blood samples were obtained before (Pre), immediate (IP), 20- (20P), and 40-min (40P) postexercise. Continuous-wave near-infrared spectroscopy was used to measure oxygen desaturation during exercise. RESULTS: No differences in muscle deoxygenation were seen between LI and HI. However, time-dependent postexercise reoxygenation was significantly different between the two exercise sessions (35.3 +/- 17.4 s vs 24.5 +/- 14.3 s in LI and HI, respectively). Testosterone and growth hormone (GH) concentrations were significantly elevated from Pre at IP, 20P, and 40P in both LI and HI. GH concentrations were higher (P<0.05) for LI than at HI at 20P and 40P. CONCLUSION: Muscle oxygen recovery kinetics appeared to be influenced by differences in the intensity and volume of exercise, and delayed reoxygenation appears to affect the GH response to exercise.