PubMed Health⌕ Search

Biomedical subjects

Soichi Otsuki

Publications and source records attributed to Soichi Otsuki.

3 recordsLinked to original sources

Thickness measurements on transparent substrates based on reflection ellipsometry. I. Optical effects of high-refractive-index additional layers.

Theoretical studies were conducted for thickness measurements using transparent substrates on the external and internal reflection configurations. For three-phase systems consisting of ambient, film, and substrate, the refractive index of the substrate could be optimized to obtain the high sensitivity of an ellipsometric quantity delta to the film thickness and the small susceptibility of delta to errors in the incident angle. It was shown that the combination of an ordinary glass substrate and an additional dielectric layer with an appropriate layer thickness works as a synthetic high-index single substrate (SHIS). The optical effect of the combination was approximately described by use of the effective refractive index of SHIS. A method to select the refractive index of the additional layer was also given.

Journal Article↗

Wavelength-scanning surface plasmon resonance imaging.

A new surface plasmon resonance (SPR) imaging technique was proposed. After measurements were conducted at varying wavelengths, the wavelength affording the minimum brightness (SPR wavelength) was determined at each pixel of the image. A two-dimensional map of the SPR wavelength could be converted to a thickness profile by use of a nonlinear calibration curve, which was obtained by Fresnel calculation. An array of protein thin layers on a gold film was evaluated in air to present the layers' surface structure in nanometer scale.

Algorithms↗

Two-dimensional thickness measurements based on internal reflection ellipsometry.

An imaging ellipsometer technique on internal reflection geometry that can measure the thickness distribution of a thin film possessing an assumed refractive index is described. Because a prism is used for the internal reflection geometry, it was theoretically predicted that angular derivation from the normal incidence on the prism surface affects only the psi value by a factor of 0.97 at maximum. Measurements were carried out for an optical system of silica substrate-TiO2 layer-silica layer-protein film-air, with a thin-film array of dried protein as the sample film. Thickness of the protein films was two-dimensionally estimated only from the measured map of the delta value by use of the simulated relationship between the thickness and the delta value. The thickness map obtained was coincident on the whole with the results according to a mechanical scanning. The detection limit was approximately +/- 0.2 nm. These findings validate the optical effect of a high-index additional layer to improve the sensitivity and precision of thickness measurements of the sample film on transparent substrates.

Coated Materials, Biocompatible↗