Abstract

An imaging ellipsometer technique on internal reflection geometry that can measure the thickness distribution of a thin film possessing an assumed refractive index is described. Because a prism is used for the internal reflection geometry, it was theoretically predicted that angular derivation from the normal incidence on the prism surface affects only the psi value by a factor of 0.97 at maximum. Measurements were carried out for an optical system of silica substrate-TiO2 layer-silica layer-protein film-air, with a thin-film array of dried protein as the sample film. Thickness of the protein films was two-dimensionally estimated only from the measured map of the delta value by use of the simulated relationship between the thickness and the delta value. The thickness map obtained was coincident on the whole with the results according to a mechanical scanning. The detection limit was approximately +/- 0.2 nm. These findings validate the optical effect of a high-index additional layer to improve the sensitivity and precision of thickness measurements of the sample film on transparent substrates.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Soichi Otsuki, Kaoru Tamada, Shin-ichi Wakida. 2005-03-10. Two-dimensional thickness measurements based on internal reflection ellipsometry.. https://doi.org/10.1364/ao.44.001410

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Acid-induced bioactive titania surface.

Nano- and conventional-TiO(2) powders were deposited onto titanium alloy using atmospheric plasma spraying technology. As-sprayed titania coatings were treated by H(2)SO(4) and HCl solutions at room temperature for 24 h, and the bioactivity was evaluated by simulated body fluid tests. Measured X-ray diffraction patterns indicated that as-sprayed titania coatings obtained from both nano and conventional powders were composed of primary rutile as well as a small quantity of anatase and Ti(3)O(5). The surface of as-sprayed coatings prepared from the conventional powder was rougher than that from nanopowder. After immersion in simulated body fluid for 2 weeks, both acid-treated nano- and titania coatings have induced carbonate-containing hydroxyapatite to form on the surfaces. However, this phenomenon did not appear on the surface of as-sprayed nano- and conventional-titania coatings. The results obtained indicated that the bioactivity of plasma sprayed titania coatings was improved by the acid treatment and had nothing to do with phase composition and particle size of the original TiO(2) powders.

Coated Materials, Biocompatible↗

Efficacy and complications in the surgical treatment of stress urinary incontinence by insertion of a silicone-coated polyester tape (Lift).

OBJECTIVES: To evaluate the efficacy and safety of a surgical treatment for stress urinary incontinence by implantation of a silicone-coated polyester tape (Lift). MATERIALS AND METHODS: This retrospective study included 72 female patients having had a suburethral silicone-coated polyester tape inserted as treatment for stress urinary incontinence, combined or not with pelvic surgery. We recorded the patient's characteristics, the surgical procedure, the short and long-term results and complications. RESULTS: Seventy-two patients were operated, 60 of whom were fully evaluated. The average follow-up was 17 months. On 48 patients (80%) the treatment was successful, 3 (5%) were improved, and 9 (15%) were regarded as a failure. Dysuria occurred in six (10%) patients, five were de novo, and one was persistent. Ten patients (16.6%) presented de novo urge incontinence. The main complication was a higher rate of severe infections, accompanied by defective healing (4, i.e. 6.7%). CONCLUSION: The procedure using a silicone-coated polyester tape seems to be efficient, but insufficiently secure. This higher rejection rate leads us to prefer other synthetic materials proved to be better tolerated.

Coated Materials, Biocompatible↗

Use of water to evaluate hydrophobicity of organically-modified xerogel enzyme supports.

Silica xerogels are a new class of materials suitable for the immobilization of enzymes for various applications including biotransformations and biosensors. The physicochemical properties of xerogels, such as hydrophobicity, can be manipulated by the introduction of organically-modified silicates. This allows the immobilization matrix to be engineered to suit the enzyme and its application. Interfacial activation of lipase is a phenomenon in which the enzyme displays increased activity when it is bound to a hydrophobic interface. Lipase was entrapped in organically-modified xerogels in which the hydrophobicity of the enzyme support was modulated by the selection of different alkyltrimethoxysilane co-precursors and the ratio in which they were combined with tetramethyl orthosilicate. Interaction between the enzyme support and water was investigated with two methods to quantitatively assess the hydrophobicity of the entrapment matrix. The contact angle formed between the xerogel and water was used to determine hydrophobicity on a macroscopic level. Temperature-controlled water desorption was used to determine hydrophobicity on a microscopic level. Both methods were suitable for quantitatively discriminating between hydrophobic and hydrophilic materials. Further, the hydrophobicity of the enzyme support influenced the hydrolytic activity of the entrapped lipase under non-aqueous conditions. The specific activity of lipase increased only when entrapped in xerogels which could be classified as hydrophobic materials, that is with contact angles greater than 90 degrees or hydrophobicity values as determined by water desorption greater than 0.65.

Coated Materials, Biocompatible↗