Srinivasan Vedantham

Publications and source records attributed to Srinivasan Vedantham.

7 recordsLinked to original sources

Theoretical analysis of high-resolution digital mammography.

The performance of a high-resolution charge coupled device-based full-field digital mammography imager was analysed using a mathematical framework based on an adaptation of cascaded linear systems theory described by other investigators. This work has been conducted in order to understand the impact of various design parameters on the physical performance characteristics of the imager. Specifically, the effect of pixel size, scintillator thickness and packing density, x-ray spectra, air kerma, dark current, charge integration time, and pixel fill-factor on the frequency dependent detective quantum efficiency was studied using a charge-coupled device as a reference platform. The imaging system was modelled as a series of physical processes with gain and spatial spreading. For each stage, the signal and noise power spectra were computed and propagated through the imaging chain as inputs to subsequent stages. Good agreement between experimental and theoretical predictions was obtained for various x-ray spectral conditions that were investigated. The modulation transfer function, MTF(f) and detective quantum efficiency DQE(f) characteristics obtained in this study are encouraging and comparable to other digital mammography systems. The results of this study strongly suggest the feasibility of large area scintillator-based digital mammography imagers with pixel sizes below 100 microm.

Algorithms↗

High-resolution imager for digital mammography: physical characterization of a prototype sensor.

The physical performance characteristics of a high-resolution sensor module for digital mammography were investigated. The signal response of the imager was measured at various detector entrance air kerma and was found to be linear. The spatial resolution was determined by measuring the presampling modulation transfer function, MTF(f), of the system. The noise power spectra, NPS(f), of the system were estimated using 26 kVp: Mo/Mo, 28 kVp: Mo/Rh and 30 kVp: Rh/Rh, with polymethyl methacrylate (PMMA) 'tissue equivalent material' of thickness 20, 45 and 57 mm for each of three x-ray spectra at detector entrance air kerma in the range between approximately 80.2 and 92.3 microGy. The noise equivalent quanta, NEQ(f), and detective quantum efficiencies, DQE(f), for the various spectral conditions were computed. In addition, dose dependence of NPS(f) and DQE(f) was studied at various detector entrance air kerma ranging from 9.4 to 169.7 microGy. A spatial resolution of about 10 cycles mm(-1) was obtained at the 10% MTF(f) level. A small increase in NEQ(f)was observed under higher energy spectral conditions while the DQE(f) decreased marginally. For a given spectrum, increasing PMMA filtration produced negligible change in DQE(f). The estimated DQE values at zero frequency were in the range between 0.45 and 0.55 under the conditions investigated in this study.

Equipment Design↗

Detection of simulated lesions on data-compressed digital mammograms.

PURPOSE: To evaluate retrospectively the effect of a wavelet-based compression method on the detection of simulated masses of various sizes and clustered microcalcifications on data-compressed digital mammograms. MATERIALS AND METHODS: The images used in this study were acquired with institutional review board approval and patient informed consent, both of which allowed subsequent image data analysis. Patient identification was removed from images, and the study complied with requirements of the Health Insurance Portability and Accountability Act. Masses 3, 6, and 8 mm in diameter were analytically simulated and added to clinical mammographic backgrounds. In addition, microcalcifications were extracted from a clinical mammogram and hybridized with simulated microcalcifications for use in this study. Image compression conditions of 1:1, 15:1, and 30:1 were investigated. Observer responses were recorded with a six-point rating scale, and receiver operating characteristic (ROC) analysis was performed. In addition, two well-established numeric observer models were used to study the effect of image compression under the same compression conditions as were used with human observers. Analysis of variance was performed after observer adjustment to compare the mean values for area under the ROC curve (A(z)) across the three compression levels for the masses and microcalcification clusters. RESULTS: The results of the study indicated no significant differences in the A(z) values for masses with the compression conditions investigated. For images of microcalcifications, there were significant differences in A(z) values between compression ratios of 1:1 and 30:1 (P = .0005) and of 15:1 and 30:1 (P = .004); the difference between compression ratios of 1:1 and 15:1 was nonsignificant (P = .053). The observer models and human observers exhibited similar trends in detection of the masses investigated in this study. CONCLUSION: Detection of simulated masses was not affected by the compression method with the conditions used in this study, while the detection of microcalcifications was significantly reduced with a compression ratio of more than 15:1.

Analysis of Variance↗

A perceptual evaluation of JPEG 2000 image compression for digital mammography: contrast-detail characteristics.

In this investigation the effect of JPEG 2000 compression on the contrast-detail (CD) characteristics of digital mammography images was studied using an alternative forced choice (AFC) technique. Images of a contrast-detail phantom, acquired using a clinical full-field digital mammography system, were compressed using a commercially available software product (JPEG 2000). Data compression was achieved at ratios of 1:1, 10:1, 20:1, and 30:1 and the images were reviewed by seven observers on a high-resolution display. Psychophysical detection characteristics were first computed by fitting perception data using a maximum-likelihood technique from which CD curves were derived at 50%, 62.5%, and 75% threshold levels. Statistical analysis indicated no significant difference in the perception of mean disk thickness up to 20:1 compression except for disk diameter of 1 mm. All other compression combinations exhibited significant degradation in CD characteristics.

Algorithms↗

Solid-state fluoroscopic imager for high-resolution angiography: parallel-cascaded linear systems analysis.

Cascaded linear systems based modeling techniques have been used in the past to predict important system parameters that have a direct impact on image quality. Such models are also useful in optimizing system parameters to improve image quality. In this work, detailed analysis of a solid-state fluoroscopic imaging system intended for high-resolution angiography is presented with the use of such a model. The imaging system analyzed through this model uses four 8 x 8 cm three-side buttable interlined charge-coupled devices (CCDs) specifically designed for high-resolution angiography and tiled in a seamless fashion to achieve a field of view (FOV) of 16 x 16 cm. Larger FOVs can be achieved by tiling more CCDs in a similar manner. The system employs a CsI:Tl scintillator coupled to the CCDs by straight (nontapering) fiberoptics and can potentially be operated in 78, 156, or 234 microm pixel pitch modes. The system parameters analyzed through this model include presampling modulation transfer function, noise power spectrum, and detective quantum efficiency (DQE). The results of the simulations performed indicate that DQE(0) in excess of 0.6 is achievable, with the imager operating at 156 microm pixel pitch, 30 frames/s, and employing a 450-microm-thick CsI:Tl scintillator, even at a low fluoroscopic exposure rate of 1 microR/frame. Further, at a nominal fluoroscopic exposure rate of 2.5 microR/frame there was no noticeable degradation of the DQE even at the 78 microm pixel pitch mode suggesting that it is feasible to perform high-resolution angiography hitherto unattainable in clinical practice.

Angiography↗

Solid-state fluoroscopic imager for high-resolution angiography: physical characteristics of an 8 cm x 8 cm experimental prototype.

In this paper, the performance of an 8 cm x 8 cm three-side buttable charge-coupled device (CCD)-based imager specially designed for high-resolution fluoroscopy and operating in fluoroscopic (30 frames/second) mode is presented in terms of the presampling modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). The 8 cm x 8 cm CCD imager is coupled to a 450 microm thick CsI:Tl scintillator by nondemagnifying (straight, 1:1) fiberoptics. The CCD imager has a fundamental pixel pitch of 39 microm and incorporates an optically opaque interline (data) channel. The CCD imager was operated at 156 microm pixel pitch by binning 4 x 4 adjacent pixels prior to readout. The fluoroscopic image lag was measured and accounted for in the DQE estimate to provide lag-corrected DQE. The measured limiting spatial resolution at 10% presampling MTF with the imager operated at 156 microm pixel pitch (Nyquist sampling limit: 3.21 cy/mm) was 3.6 cy/mm. In the pulsed fluoroscopic mode, the first-frame image lag was less than 0.9%. The lag-corrected DQE(0) of approximately 0.62 was achieved even at a low fluoroscopic exposure rate of 1 microR/frame. Grid phantom measurements indicate no appreciable distortion. Results from DQE and image lag measurements at fluoroscopic exposure rates combined with the high spatial resolution observed from the MTF suggest that this type of imager or its variants may be a potential candidate for high-resolution neuro-interventional imaging, cardiovascular imaging, pediatric angiography, and small animal imaging. Since the CCD is three-side buttable, four such CCD modules can be joined to form a 2 x 2 matrix providing a field of view of 16 cm x 16 cm.

Angiography↗

Flat-panel digital mammography system: contrast-detail comparison between screen-film radiographs and hard-copy images.

PURPOSE: To compare the contrast-detail (CD) characteristics of screen-film (SF) and postprocessed digital images by using a phantom-based method. MATERIALS AND METHODS: Images of a CD phantom with polymerized methyl methacrylate were acquired with SF and full-field digital mammography systems at matched exposure conditions. A four-alternative forced-choice experiment was conducted with seven observers participating in the study. Each observer was required to identify randomly located disks in phantom images from which detection curves were computed. The CD diagrams for the SF and digital systems were estimated from the detection curves and compared at 50% and 62.5% threshold levels. Furthermore, a theoretic model was used to estimate the CD performance of the SF and digital systems. RESULTS: Analysis of covariance for mixed models was used with the natural logarithm of disk thickness as the dependent variable, the natural logarithm of disk diameter as the covariate, and the observer as a random factor. The results of statistical analysis indicated significant differences between the CD characteristics of SF and digital mammographic images at both 50% (P <.001) and 62.5% (P <.001) detection thresholds. CONCLUSION: The authors conclude that digital CD curves, on average, exhibit threshold contrast characteristics that are lower (better) than those of SF mammography.

Algorithms↗