PubMed Health⌕ Search

Biomedical subjects

Stephan Achenbach

Publications and source records attributed to Stephan Achenbach.

At least 19 recordsLinked to original sources

Impact of Diabetes on Outcomes of Contemporary PCI Guided by OCT vs Angiography: The ILUMIEN IV Trial.

BACKGROUND: Patients with diabetes are at higher risk for adverse events after percutaneous coronary intervention (PCI) compared with patients without diabetes. OBJECTIVES: This study sought to assess the influence of diabetes and complex lesions on the outcomes of patients undergoing PCI with and without optical coherence tomography (OCT) guidance during a follow-up period of 2 years. METHODS: Patients in ILUMIEN IV randomized to OCT-guided vs angiography-guided PCI were grouped into those with (n = 1,044) and without diabetes (n = 1,443). Study endpoints were target vessel failure (TVF) and serious major adverse cardiovascular events (MACE). RESULTS: After adjustment for differences in clinical and angiographic characteristics, the 2-year rates of both TVF (9.9% vs 6.3%; adjusted HR: 1.48; 95% CI: 1.09-2.02; P = 0.01) and serious MACE (5.3% vs 2.7%; adjusted HR: 1.77; 95% CI: 1.14-2.76; P = 0.01) were increased in diabetic compared with nondiabetic patients, consistently in patients with and without complex lesions (Pinteraction = 0.22 and 0.14, respectively), although the highest 2-year rates were in patients with diabetes and complex lesions. In all randomized patients, OCT guidance compared with angiography guidance did not reduce TVF or serious MACE. These effects were consistent in patients with and without diabetes (Pinteraction = 0.41 and 0.20, respectively), and were not modified by treatment of complex lesions. CONCLUSIONS: In the large-scale ILUMIEN IV trial, patients with diabetes remained at increased risk for adverse events after PCI compared with nondiabetic patients despite the use of OCT procedural guidance. Patients with diabetes and complex lesions were at particularly high risk for adverse outcomes after PCI.

Humans↗

Impact of renal dysfunction on immediate versus staged revascularization of non-culprit lesions in patients with ST segment elevation myocardial infarction: a pre-specified subgroup analysis of the randomized MULTISTARS AMI trial.

BACKGROUND: Renal dysfunction might affect outcomes in patients with ST-segment elevation myocardial infarction (STEMI) and multivessel coronary artery disease (MVD) undergoing percutaneous coronary intervention (PCI). METHODS: In MULTISTARS AMI, patients with STEMI and MVD were randomized to immediate or staged PCI of non-culprit lesions. In this pre-specified analysis, patients were stratified according to the presence of renal dysfunction at baseline, defined at an estimated glomerular filtration rate (eGFR) of 60&#xa0;ml/min/1.73 m2. Patients with an eGFR&#x2009;<&#x2009;30&#xa0;ml/min/1.73 m2 were excluded from the trial. The primary endpoint was a composite of death, non-fatal myocardial infarction, stroke, unplanned revascularization, or hospitalization for heart failure at 1&#xa0;year. RESULTS: In MULTISTARS AMI, 108 (13%) of 832 patients had renal dysfunction. The primary endpoint occurred more frequently in patients with renal dysfunction (19.4% vs. 11.2%, unadjusted HR 1.82, 95% CI 1.13-2.94), primarily driven by higher rates of death. Among patients with renal dysfunction, the rates of the primary end point were 14.5% and 24.5% in the immediate and staged PCI groups (unadjusted HR 0.55, 95% CI 0.23-1.33). There was no interaction between renal dysfunction and the randomized treatment assignment with respect to the primary end point (adjusted HR 1.30, 95% CI 0.8-2.20, pint 0.82). The occurrence of acute renal insufficiency was statistically similar in patients with renal dysfunction who underwent immediate and staged PCI (10.9% vs. 18.9%, unadjusted HR 0.61, 95% CI 0.22-1.72, pint 0.09). Renal dysfunction at baseline emerged as a strong risk factor for the development of acute renal insufficiency (adjusted HR 5.0, 95% CI 2.30-10.70, p&#x2009;<&#x2009;0.01). CONCLUSIONS: Outcomes with immediate compared to staged multivessel PCI did not appear significantly altered by the presence of renal dysfunction&#xa0;at baseline. (Supported by Boston Scientific; MULTISTARS AMI ClinicalTrials.gov number, NCT03135275).

Humans↗

Diagnostic accuracy of noninvasive coronary angiography in patients after bypass surgery using 64-slice spiral computed tomography with 330-ms gantry rotation.

BACKGROUND: Multidetector computed tomographic angiography (MDCT) has been shown to allow detection of coronary artery bypass graft (CABG) occlusions and stenoses. However, the assessment of native coronary arteries in addition to CABG has thus far not been sufficiently validated. METHODS AND RESULTS: Fifty patients with a total of 138 CABG (34 mammary grafts, 3 radial grafts, 101 venous grafts) were investigated by MDCT (0.6-mm collimation, 32 detector rows, 2 focal points, 330-ms rotation) 9 to 252 months (mean, 106 months) after surgery. CABG and all native coronary arteries with a diameter of > 1.5 mm were evaluated for the presence of significant stenoses (> or = 50% diameter reduction). Results were compared with quantitative coronary angiography. By MDCT, all CABG were evaluable and were correctly classified as occluded (n=38) or patent (n=100). Sensitivity for stenosis detection in patent grafts was 100% (16/16) with a specificity of 94% (79/84). For the per-segment evaluation of native coronary arteries and distal runoff vessels, sensitivity in evaluable segments (91%) was 86% (87/101) with a specificity of 76% (354/465). If evaluation was restricted to nongrafted arteries and distal runoff vessels, sensitivity was 86% (38/44) with a specificity of 90% (302/334). On a per-patient basis, classifying patients with at least 1 detected stenosis in a CABG, a distal runoff vessel, or a nongrafted artery or with at least 1 unevaluable segment as "positive," MDCT yielded a sensitivity of 97% (35/36) and specificity of 86% (12/14). CONCLUSIONS: We found that 64-slice MDCT permits the evaluation of bypass grafts and the assessment of the native coronary arteries for the presence of stenosis.

Adult↗

Computed tomography coronary angiography.

Recent developments in computed tomography technology have made imaging of the coronary arteries possible. All the same, the rapid motion and small dimensions of the coronary vessels make coronary computed tomography angiography (coronary CTA) challenging. With the last generations of 16- and 64-slice computed tomography and adequate patient preparation (which includes lowering of the heart rate), rates of sensitivity ranging from 83% to 99% and specificity between 93% and 98% have been reported for the detection of coronary artery stenoses in comparison with invasive coronary angiography. The high negative predictive value (95% to 100%) found in these studies suggests that coronary CTA may be a useful diagnostic technique to rule out the presence of coronary stenoses in selected patients, especially those with a rather low pretest likelihood of disease. Imaging of coronary artery bypass grafts is reliable, but clinical applications can be hampered by difficulties in assessing the native coronary arteries in patients after undergoing bypass because of their often-severe calcification. The detection of in-stent restenosis is made difficult by artifacts caused by metal, especially in smaller stents. Finally, initial reports that coronary CTA allows the detection and, to a certain extent, also the characterization and quantification of noncalcified coronary arteriosclerotic plaque are interesting, but they currently do not provide sufficient data to support clinical applications in the context of risk stratification.

Artifacts↗

Coronary multidetector computed tomography in the assessment of patients with acute chest pain.

BACKGROUND: Noninvasive assessment of coronary atherosclerotic plaque and significant stenosis by coronary multidetector computed tomography (MDCT) may improve early and accurate triage of patients presenting with acute chest pain to the emergency department. METHODS AND RESULTS: We conducted a blinded, prospective study in patients presenting with acute chest pain to the emergency department between May and July 2005 who were admitted to the hospital to rule out acute coronary syndrome (ACS) with no ischemic ECG changes and negative initial biomarkers. Contrast-enhanced 64-slice MDCT coronary angiography was performed immediately before admission, and data sets were evaluated for the presence of coronary atherosclerotic plaque and significant coronary artery stenosis. All providers were blinded to MDCT results. An expert panel, blinded to the MDCT data, determined the presence or absence of ACS on the basis of all data accrued during the index hospitalization and 5-month follow-up. Among 103 consecutive patients (40% female; mean age, 54+/-12 years), 14 patients had ACS. Both the absence of significant coronary artery stenosis (73 of 103 patients) and nonsignificant coronary atherosclerotic plaque (41 of 103 patients) accurately predicted the absence of ACS (negative predictive values, 100%). Multivariate logistic regression analyses demonstrated that adding the extent of plaque significantly improved the initial models containing only traditional risk factors or clinical estimates of the probability of ACS (c statistic, 0.73 to 0.89 and 0.61 to 0.86, respectively). CONCLUSIONS: Noninvasive assessment of coronary artery disease by MDCT has good performance characteristics for ruling out ACS in subjects presenting with possible myocardial ischemia to the emergency department and may be useful for improving early triage.

Acute Disease↗

Assessment of coronary artery stent restenosis by 64-slice multi-detector computed tomography.

AIMS: We investigated the feasibility of assessing coronary artery stent restenosis using a new generation 64-slice multi-detector computed tomography-scanner (MDCT) in comparison to conventional quantitative angiography. METHODS AND RESULTS: MDCT was performed in 64 consecutive patients (mean age 58+/-10 years) with previously implanted coronary artery stents (102 stented lesions: mean stent diameter 3.17+/-0.38 mm). Each stent was classified as 'evaluable' or 'unevaluable', and in evaluable stents, the presence of in-stent restenosis (diameter reduction >50%) was determined visually. Results were verified against invasive, quantitative coronary angiography. Fifty-nine stented lesions (58%) were classified as evaluable in MDCT. The mean diameter of evaluable stents was 3.28+/-0.40 mm, whereas the mean diameter of non-evaluable stents was 3.03+/-0.31 mm (P=0.0002). Overall, six of 12 in-stent restenoses were correctly detected by MDCT [50% sensitivity (confidence interval 22-77%)] and in 51 of 90 lesions, in-stent restenosis was correctly ruled out [57% specificity (46-67%)]. In evaluable stents, six of seven in-stent restenoses were correctly detected, and the absence of in-stent stenosis was correctly identified in 51 of 52 cases [sensitivity 86% (42-99%) and specificity 98% (88-100%)]. CONCLUSION: Stent type and diameter influence evaluability concerning in-stent restenosis by MDCT. The rate of assessable stents is low, but in evaluable stents, accuracy for detection of in-stent restenosis can be high.

Coronary Restenosis↗

Comparison of sixty-four-slice multidetector computed tomographic coronary angiography to coronary angiography with intravascular ultrasound for the detection of transplant vasculopathy.

Coronary allograft vasculopathy (CAV) is the most important limitation to long-term survival in adult heart transplant recipients and is difficult to detect without intravascular ultrasound (IVUS). We systematically evaluated the image quality of 64-slice multidetector computed tomographic (MDCT) coronary angiography in heart transplant recipients and tested the hypothesis that this modality is comparable to invasive coronary angiography with IVUS for the detection of CAV. Heart transplant recipients (n = 20) underwent invasive coronary angiography with IVUS and MDCT coronary angiography with a 64-slice scanner. Images were systematically analyzed for image quality and the presence of CAV. In addition, multidetector computed tomography and quantitative coronary angiography were used to measure lumen diameters at prespecified locations. Image quality analysis showed that, despite high mean heart rates (77 +/- 7 beats/min) and body mass index (29.5 +/- 5.3 kg/m(2)), 83% of coronary segments were graded as of excellent or good image quality. On average, 95 +/- 9% of the overall visualized length of the coronary arteries was imaged without motion artifacts, and the mean contrast-to-noise ratio was 11.3 +/- 4.6. Compared with IVUS, multidetector computed tomography had a sensitivity of 70%, specificity of 92%, positive predictive value of 89%, and negative predictive value of 77% for the detection of CAV. MDCT vessel diameter measurements correlated well with those obtained from quantitative coronary angiography (R(2) = 0.89). In conclusion, 64-slice multidetector computed tomography provides good to excellent image quality in heart transplant recipients and has moderate to excellent test characteristics for the detection of CAV. Further, MDCT measurements of lumen diameters correlated well with quantitative coronary angiography.

Body Mass Index↗

Arterial wall imaging: evaluation with 16-section multidetector CT in blood vessel phantoms and ex vivo coronary arteries.

PURPOSE: To evaluate the diagnostic performance of 16-section multidetector computed tomography (CT) for assessment of plaques in phantoms and ex vivo coronary arteries, with intravascular ultrasonography (US) and optical coherence tomography (OCT) as reference standards. MATERIALS AND METHODS: Research protocol was HIPAA compliant and approved by institutional review board, without informed consent required. Blood vessel and lesion composition phantoms and ex vivo coronary arteries were imaged with 16-section CT. Wall areas of phantoms and ex vivo coronary arteries were measured with multidetector CT and intravascular US. Sensitivity and specificity for lipid detection were determined in lesion composition phantoms. CT numbers of blood vessel wall were determined in ex vivo coronary arteries and compared with lesion classification results from OCT. Agreement in dimensional measurements was compared (paired t tests). CT numbers within blood vessel wall of CT cross sections classified as lipid rich, fibrous, and calcified at OCT were compared (Kruskal-Wallis tests). RESULTS: Mean blood vessel wall areas measured with CT and US in phantoms were 9.2 mm(2) +/- 1.8 (standard deviation) and 10.4 mm(2) +/- 3.4 (bias, -1.3 mm(2) +/- 3.1; P < .05), respectively. Mean blood vessel wall areas measured in ex vivo coronary arteries with CT and US were 10.9 mm(2) +/- 4.1 and 9.1 mm(2) +/- 3.1 (bias, 1.8 mm(2) +/- 3.0; P < .001), respectively. Sensitivity and specificity of 93% and 92%, respectively, for identification of lipid-rich lesions were observed in lesion composition phantoms. Mean CT numbers in blood vessel wall of ex vivo coronary arteries identified at OCT as predominantly lipid rich, fibrous, and calcified were 29 HU +/- 43, 101 HU +/- 21, and 135 HU +/- 199, respectively (P < .001). CONCLUSION: Determination of composition of individual plaques from attenuation values can be more challenging because of overlapping values for different tissue types.

Coronary Angiography↗

Noninvasive assessment of plaque morphology and composition in culprit and stable lesions in acute coronary syndrome and stable lesions in stable angina by multidetector computed tomography.

OBJECTIVES: The purpose of this study was to assess morphology and composition of culprit and stable coronary lesions by multidetector computed tomography (MDCT). BACKGROUND: Noninvasive identification of culprit lesions has the potential to improve noninvasive risk stratification in patients with acute chest pain. METHODS: Thirty-seven patients with acute coronary syndrome (ACS) or stable angina underwent coronary 16-slice MDCT and invasive selective angiography. In all significant coronary lesions two observers measured the degree of stenosis, plaque area at stenosis, and remodeling index and assessed plaque composition. Differences between culprit lesions in patients with ACS and stable lesions in patients with ACS or stable angina were determined. RESULTS: We analyzed 40 lesions with excellent image quality in 14 patients with ACS and 9 patients with stable angina. Culprit lesions in patients with ACS (n = 14) had significantly greater plaque area and a higher remodeling index than both stable lesions in patients with ACS (n = 13) and in patients with stable angina (n = 13) (17.5 +/- 5.9 mm2 vs. 9.1 +/- 4.8 mm2 vs. 13.5 +/- 10.7 mm2, p = 0.02; and 1.4 +/- 0.3 vs. 1.0 +/- 0.4 vs. 1.2 +/- 0.3, p = 0.04, respectively). The prevalence of non-calcified plaque was 100%, 62%, and 77%, respectively, and the prevalence of calcified plaque was 71%, 92%, and 85%, respectively, in culprit lesions in patients with ACS and in stable lesions in patients with ACS or stable angina. CONCLUSIONS: We introduce the concept of noninvasive detection and characterization of coronary atherosclerotic lesions in patients with ACS by MDCT. We identified differences in lesion morphology and plaque composition between culprit lesions in ACS and stable lesions in ACS or stable angina, consistent with previous intravascular ultrasound studies.

Acute Disease↗

Characterization of non-calcified coronary atherosclerotic plaque by multi-detector row CT: comparison to IVUS.

UNLABELLED: Multi-detector row Computed Tomography (MDCT) permits non-invasive visualization of the coronary arteries. The ability to visualize and, with limitations, to characterize non-calcified coronary atherosclerotic plaque has been described. We investigated the CT attenuation of non-calcified plaques as determined by 16-slice MDCT in comparison to intravascular ultrasound (IVUS). METHODS AND RESULTS: Thirty-two patients were investigated by contrast-enhanced 16-slice CT. In addition, IVUS of one coronary artery (motorized pullback) was performed (LM+LAD: 22, LM+LCX: 4, RCA: 6). At 252 sites within the coronary system, in which non-calcified atherosclerotic plaque could be identified both in MDCT and IVUS, the CT attenuation within the plaque was measured using a centrally placed region of interest and correlated to the appearance of the plaque in IVUS at the corresponding location. The mean CT attenuation within plaque that corresponded to hyper-echogenic appearance in IVUS was 121+/-34HU (n=76). The mean CT attenuation within plaque that corresponded to hypo-echogenic appearance was 58+/-43HU (n=176, p<0.001). However, there was substantial overlap of the density values measured by MDCT in the two groups. CONCLUSIONS: A significant difference of the mean CT attenuation within atherosclerotic lesions of hypo-echogenic and hyper-echogenic appearance in IVUS could be observed. However, we observed substantial overlap of attenuation values between plaque types so that the differentiation of "vulnerable" and "stable" plaques based on their CT attenuation is doubtful.

Aged↗

Coronary MR imaging: breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use.

PURPOSE: To prospectively evaluate breath-hold capability and patterns, coronary artery rest periods, and beta-blocker use in coronary magnetic resonance (MR) imaging. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. In 210 consecutive patients (mean age, 61.8 years +/- 10.3 [standard deviation]; 146 men, 64 women), breath-hold patterns and maximal capability were assessed at expiration with dynamic navigator MR imaging (temporal resolution, 1 second). Left coronary artery (LCA) and right coronary artery (RCA) rest periods were determined at transverse cine imaging (steady-state free precession, retrospective gating, 40 phases per cycle). Before and after beta-blockade, rest periods were assessed in 25 additional patients (mean age, 61.4 years +/- 7.1; 20 men, five women). Differences were tested within groups with paired Student t test and between groups with unpaired Student t test (continuous variables) and chi(2) test (categoric variables). Pearson correlation was used to test the relationship between rest period and heart rate. RESULTS: Four distinct breath-hold patterns, characterized by diaphragmatic motion, were identified: pattern 1, steady plateau (55% of patients); 2, initial drift followed by plateau (12%); 3, continuous drift (19%); and 4, irregular, unsteady behavior (14%). Mean breath-hold capability with patterns 1 and 2 was 29 seconds +/- 13 (range, 10-64 seconds). The rest period of LCA was longer than that of RCA (163 msec +/- 75 vs 123 msec +/- 60; P < .01) and began earlier in the cardiac cycle (521 msec +/- 149 vs 540 msec +/- 160; P < .01); In a minority of patients, LCA rest period began later (21%) or was shorter (14%). With no pharmacologic intervention, correlation between rest period duration and heart rate was weak (LCA, r = -0.52; RCA, r = -0.38; P < .01). However, beta-blockade significantly lowered heart rate (61.3 beats/min +/- 7.2 vs 82.6 beats/min +/- 12.5, P < .001) and increased rest duration (LCA, 201.8 msec +/- 83.6 vs 111.8 msec +/- 44.55; RCA, 134.8 msec +/- 57.3 vs 83.1 msec +/- 35.8; P < .001). CONCLUSION: In 33% of patients (patterns 3 and 4), breath-hold pattern was unsuitable for high-spatial-resolution breath-hold MR imaging. LCA and RCA rest periods showed large variability in starting point and duration, with no correlation to heart rate.

Adrenergic beta-Antagonists↗

Coronary artery bypass graft (CABG) patency: assessment with high-resolution submillimeter 16-slice multidetector-row computed tomography (MDCT) versus coronary angiography.

PURPOSE: To investigate the ability of 16-slice multidetector-row computed tomography (MDCT) to visualize coronary artery bypass graft (CABG) patency and to detect bypass stenoses. MATERIALS AND METHODS: Thirty-two patients with 94 grafts (20 mammary artery grafts, 74 venous grafts) were investigated by 16-slice MDCT using a scan protocol with 12 x 0.75 mm slice collimation (pitch 0.3), 420 ms rotation time and simultaneous electrocardiogram (ECG)-registration. One hundred milliliters iodinated contrast agent were injected with a delay according to the individually determined contrast agent transit time. Patients with heart rates above 60 bpm received oral beta-blockade. Cross-sectional images with a slice width of 1.0 mm (0.5 mm increment) were reconstructed using an ECG-gated half-scan reconstruction or a multisegment reconstruction algorithm depending on the heart rate. Bypass grafts were evaluated concerning patency and presence of stenoses > or = 50% diameter reduction on cross-sectional images, multiplanar reformations and maximum intensity projections by two independent observers. Results were compared to coronary bypass angiography. RESULTS: Sixteen-slice MDCT results were compared to those of invasive coronary angiography concerning absence or presence of bypass graft occlusion or relevant stenosis > or = 50% lumen reduction. Coronary CT angiography (CTA) permitted detection of bypass occlusion with 100% sensitivity (28/28) and 98% specificity (64/65). Seventy-eight percent (observer 1) and 84% (observer 2) of all patent grafts were found to be evaluable concerning presence or absence of stenosis. In 34 of 40 (observer 1) and 38 of 43 (observer 2) bypass grafts, high-grade stenoses were correctly ruled out (specificity 85% versus 88%, sensitivity 80% and 82%). Yet, if all patients with either unevaluable grafts/graft anastomosis or relevant graft stenosis were excluded, only 8/32 patients (25%) had fully diagnostic "negative" graft-CTA. According to Kappa statistics, agreement between the observers was 1.0 and 0.93 concerning occlusion and relevant stenosis, respectively. CONCLUSION: Sixteen-slice coronary CTA with sub-millimeter spatial resolution and premedication with oral beta-blockade permits non-invasive assessment of coronary artery bypass grafts with decreasing numbers of unevaluable graft segments. However, patient-based analysis reveals that only a relatively small number of patients ("negative" and completely evaluable graft-CTA) truly profits from noninvasive work-up and could be spared invasive angiography.

Adult↗

Accuracy of 16-slice multi-detector CT to quantify the degree of coronary artery stenosis: assessment of cross-sectional and longitudinal vessel reconstructions.

BACKGROUND: Sixteen-slice multi-detector computed tomography (MDCT) permits reliable noninvasive detection of significant coronary stenosis based on qualitative visual assessment. The purpose of this study was to determine the accuracy of MDCT to quantify the degree of coronary stenosis as compared to quantitative coronary angiography (QCA) using two different reconstruction methods. METHODS: We studied 69 coronary artery lesions from 38 consecutive patients that underwent 16-slice MDCT as a part of research study, which enrolled consecutive subjects scheduled for clinically indicated invasive coronary angiography. Nine coronary artery lesions with motion artifacts, heavily calcified plaques or stents were excluded from the analysis. The degree of stenosis was calculated by two independent readers non-blinded to the location of the stenosis, but blinded to the results of the QCA. MDCT luminal diameters were measured in cross-sectional multi-planar reformatted (CS-MPR) images created perpendicular to the centerline of the vessel and in 5 mm thin-slab maximum intensity projections (MIP) parallel to the long axis of the vessel. Both MDCT methods were compared against QCA. RESULTS: The mean degree of stenosis as measured by MDCT was closely correlated to QCA for both methods (CS-MPR versus QCA: 61 +/- 23% versus 64 +/- 29%; r2 = 0.83, p < 0.001 and MIP versus QCA: 64 +/- 22% versus 64 +/- 29%; r2 = 0.84, p < 0.001 for MIP. Bland-Altman analysis demonstrated a negative bias of the degree of stenosis of -2.8 +/- 12% using CS-MPR and a minimally positive bias of 0.6 +/- 12% for MIP. In stratified analysis for lesion severity (mild, 0-40%; moderate, 41-70% or severe, > 70%) the agreement between both CS-MPR and MIP was high when compared to QCA (kappa = 0.74 and 0.71, respectively). CONCLUSION: Multi-detector spiral CT permits accurate quantitative assessment of the degree of coronary stenosis in selected data sets of sufficient quality using both cross-sectional and longitudinal vessel reconstructions.

Aged↗

Improved vessel morphology measurements in contrast-enhanced multi-detector computed tomography coronary angiography with non-linear post-processing.

Multi-detector computed tomography (MDCT) permits detection of coronary plaque. However, noise and blurring impair accuracy and precision of plaque measurements. The aim of the study was to evaluate MDCT post-processing based on non-linear image deblurring and edge-preserving noise suppression for measurements of plaque size. Contrast-enhanced MDCT coronary angiography was performed in four subjects (mean age 55 +/- 5 years, mean heart rate 54 +/- 5 bpm) using a 16-slice scanner (Siemens Sensation 16, collimation 16 x 0.75 mm, gantry rotation 420 ms, tube voltage 120 kV, tube current 550 mAs, 80 mL of contrast). Intravascular ultrasound (IVUS; 40 MHz probe) was performed in one vessel in each patient and served as a reference standard. MDCT vessel cross-sectional images (1 mm thickness) were created perpendicular to centerline and aligned with corresponding IVUS images. MDCT images were processed using a deblurring and edge-preserving noise suppression algorithm. Then, three independent blinded observers segmented lumen and outer vessel boundaries in each modality to obtain vessel cross-sectional area and wall area in the unprocessed MDCT cross-sections, post-processed MDCT cross-sections and corresponding IVUS. The wall area measurement difference for unprocessed and post-processed MDCT images relative to IVUS was 0.4 +/- 3.8 mm2 and -0.2 +/- 2.2 mm2 (p < 0.05), respectively. Similarly, Bland-Altman analysis of vessel cross-sectional area from unprocessed and post-processed MDCT images relative to IVUS showed a measurement difference of 1.0 +/- 4.4 and 0.6 +/- 4.8 mm2, respectively. In conclusion, MDCT permitted accurate in vivo measurement of wall area and vessel cross-sectional area as compared to IVUS. Post-processing to reduce blurring and noise reduced variability of wall area measurements and reduced measurement bias for both wall area and vessel cross-sectional area.

Algorithms↗