PubMed Health⌕ Search

Biomedical subjects

Stephan Achenbach

Publications and source records attributed to Stephan Achenbach.

At least 37 records · Page 2Linked to original sources

Quantitative parameters of image quality in 64-slice computed tomography angiography of the coronary arteries.

We explored quantitative parameters of image quality in consecutive patients undergoing 64-slice multi-detector computed tomography (MDCT) coronary angiography for clinical reasons. Forty-two patients (36 men, mean age 61 +/- 11 years, mean heart rate 63 +/- 10 bpm) underwent contrast-enhanced MDCT coronary angiography with a 64-slice scanner (Siemens Sensation 64, 64 mm x 0.6 mm collimation, 330 ms tube rotation, 850 mAs, 120 kV). Two independent observers measured the overall visualized vessel length and the length of the coronary arteries visualized without motion artifacts in curved multiplanar reformatted images. Contrast-to-noise ratio was measured in the proximal and distal segments of the coronary arteries. The mean length of visualized coronary arteries was: left main 12 +/- 6 mm, left anterior descending 149 +/- 25 mm, left circumflex 89 +/- 30 mm, and right coronary artery 161 +/- 38 mm. On average, 97 +/- 5% of the total visualized vessel length was depicted without motion artifacts (left main 100 +/- 0%, left anterior descending 97 +/- 6%, left circumflex 98 +/- 5%, and right coronary artery 95 +/- 6%). In 27 patients with a heart rate < or = 65 bpm, 98 +/- 4% of the overall visualized vessel length was imaged without motion artifacts, whereas 96+/-6% of the overall visualized vessel length was imaged without motion artifacts in 15 patients with a heart rate > 65 bpm (p < 0.001). The mean contrast-to-noise ratio in all measured coronary arteries was 14.6 +/- 4.7 (proximal coronary segments: range 15.1 +/- 4.4 to 16.1 +/- 5.0, distal coronary segments: range 11.4 +/- 4.2 to 15.9 +/- 4.9). In conclusion, 64-slice MDCT permits reliable visualization of the coronary arteries with minimal motion artifacts and high CNR in consecutive patients referred for non-invasive MDCT coronary angiography. Low heart rate is an important prerequisite for excellent image quality.

Adult↗

Evidence for lower variability of coronary artery calcium mineral mass measurements by multi-detector computed tomography in a community-based cohort--consequences for progression studies.

PURPOSE: To compare the measurement variability for coronary artery calcium (CAC) measurements using mineral mass compared with a modified Agatston score (AS) or volume score (VS) with multi-detector CT (MDCT) scanning, and to estimate the potential impact of these methods on the design of CAC progression studies. MATERIALS AND METHODS: We studied 162 consecutive subjects (83 women, 79 men, mean age 51 +/- 11 years) from a general Caucasian community-based cohort (Framingham Heart Study) with duplicate runs of prospective electrocardiographically-triggered MDCT scanning. Each scan was independently evaluated for the presence of CAC by four experienced observers who determined a "modified" AS, VS and mineral mass. RESULTS: Of the 162 subjects, CAC was detected in both scans in 69 (42%) and no CAC was detected in either scan in 72 (45%). Calcium scores were low in the 21/162 subjects (12%) for whom CAC was present in one but not the other scan (modified AS < 20 in 20/21 subjects, mean AS 4.6 +/- 1.9). For all three quantification algorithms, the inter- and intraobserver correlation were excellent (r > 0.96). However, the mean interscan variability was significantly different between mineral mass, modified AS, and VS (coefficient of variation 26 +/- 19%, 41 +/- 28% and 34 +/- 25%, respectively; p < 0.04), with significantly smaller mean differences in pair-wise comparisons for mineral mass compared with modified AS (p < 0.002) or with VS (p < 0.03). The amount of CAC but not heart rate was an independent predictor of interscan variability (r = -0.638, -0.614 and -0.577 for AS, VS, and mineral mass, respectively; all p < 0.0001). The decreased interscan variability of mineral mass would allow a sample size reduction of 5.5% compared with modified AS for observational studies of CAC progression and for randomized clinical trials. CONCLUSION: There is significantly reduced interscan variability of CAC measurements with mineral mass compared with the modified AS or VS. However, the measurement variability of all quantification methods is predicted by the amount of CAC and is inversely correlated to the extent of partial volume artifacts. Moreover, the improvement of measurement reproducibility leads to a modest reduction in sample size for observational epidemiological studies or randomized clinical trials to assess the progression of CAC.

Adult↗

Threshold-dependent variability of coronary artery calcification measurements -- implications for contrast-enhanced multi-detector row-computed tomography.

INTRODUCTION: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). METHODS: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. RESULTS: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 +/- 68.7 HU versus 295 +/- 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. DISCUSSION: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

Calcinosis↗

Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience.

UNLABELLED: Multi-detector computed tomography (CT) scanners, by virtue of their high temporal and spatial resolution, permit imaging of the coronary arteries. However, motion artifacts, especially in patients with higher heart rates, can impair image quality. We thus evaluated the performance of a new dual-source CT (DSCT) with a heart rate independent temporal resolution of 83 ms for the visualization of the coronary arteries in 14 consecutive patients. METHODS: Fourteen patients (mean age 61 years, mean heart rate 71 min(-1)) were studied by DSCT. The system combines two arrays of an X-ray tube plus detector (64 slices) mounted on a single gantry at an angle of 90 degrees With a rotation speed of 330 ms, a temporal resolution of 83 ms (one-quarter rotation) can be achieved independent of heart rate. For data acquisition, intraveous contrast agent was injected at a rate of 5 ml/s. Images were reconstructed with 0.75 slice thickness and 0.5 mm increment. The data sets were evaluated concerning visibility of the coronary arteries and occurrence of motion artifact. RESULTS: Visualization of the coronary arteries was successful in all patients. Most frequently, image reconstruction at 70% of the cardiac cycle provided for optimal image quality (50% of patients). Of a total of 226 coronary artery segments, 222 (98%) were visualized free of motion artifact. In summary, DSCT constitutes a promising new concept for cardiac CT. High and heart rate independent temporal resolution permits imaging of the coronary arteries without motion artifacts in a substantially increased number of patients as compared to earlier scanner generations. Larger and appropriately designed studies will need to determine the method's accuracy for detection of coronary artery stenoses.

Artifacts↗

Effect of intensive versus standard lipid-lowering treatment with atorvastatin on the progression of calcified coronary atherosclerosis over 12 months: a multicenter, randomized, double-blind trial.

BACKGROUND: Recent clinical trials have suggested that intensive versus standard lipid-lowering therapy provides for additional benefit. Electron-beam computed tomography provides the opportunity to quantify the progression of coronary artery calcification (CAC) in serial measurements. METHODS AND RESULTS: In a multicenter, randomized, double-blind trial, 471 patients (age 61+/-8 years) who had no history of coronary artery disease and no evidence of high-grade coronary stenoses (>50% diameter reduction) were randomized if they had > or =2 cardiovascular risk factors and moderate calcified coronary atherosclerosis as evidenced by a CAC score > or =30. Patients were assigned to receive 80 mg or 10 mg of atorvastatin per day over 12 months. Progression of CAC volume scores could be analyzed in 366 patients. After pretreatment with 10 mg of atorvastatin for 4 weeks, 12 months of study medication reduced LDL cholesterol from 106+/-22 to 87+/-33 mg/dL in the group randomized to receive 80 mg of atorvastatin (P<0.001), whereas levels remained stable in the group randomized to receive 10 mg (108+/-23 at baseline, 109+/-28 mg/dL at the end of the study, P=NS). The mean progression of CAC volume scores, corrected for the baseline CAC volume score, was 27% (95% CI 20.8% to 33.1%) in the 80-mg atorvastatin group and 25% (95% CI 19.1% to 30.8%) in the 10-mg atorvastatin group (P=0.65). CAC progression showed no relationship with on-treatment LDL cholesterol levels. CONCLUSIONS: We did not observe a relationship between on-treatment LDL cholesterol levels and the progression of calcified coronary atherosclerosis. Over a period of 12 months, intensive atorvastatin therapy was unable to attenuate CAC progression compared with standard atorvastatin therapy. The possibility remains that the time window was too short to demonstrate an effect.

Adult↗

Measurement of coronary artery bifurcation angles by multidetector computed tomography.

OBJECTIVE: Optimal stent deployment in coronary artery bifurcations requires information about the angle between main vessel and side branch. We evaluated the accuracy and interobserver variability of bifurcation angle measurements by contrast-enhanced 16-slice multidetector computed tomography (MDCT) in comparison with invasive angiography and examined the average angles of 4 main coronary bifurcations. METHODS: To determine the accuracy of MDCT for measurement of bifurcation angles, we scanned a coronary artery phantom containing 6 bifurcations (2-mm metal rods with angles between 25 degrees and 90 degrees ) using MDCT, and angles determined in the MDCT data set were compared with the true values. To assess interobserver variability of angle measurements in comparison to invasive angiography, the angles of 3 bifurcation sites (left anterior descending and left circumflex coronary artery [LAD/LCX], LAD and first diagonal branch [LAD/Diag 1], and posterior descending coronary artery and right posterolateral branch [PDA/Rpld]) were determined in 15 patients both in 16-detector row MDCT data sets and invasive coronary angiograms by 2 independent observers each. To assess the natural distribution of the 4 main coronary artery bifurcation angles (LAD and LCX, LAD and Diag 1, LCX and OM1, PDA and Rpld), the average angles of these bifurcations were determined in 16-slice MDCT data sets acquired for coronary artery visalization in a group of 100 consecutive patients with suspected coronary artery disease. RESULTS: The phantom study revealed a mean difference between measured and true angles of 0.7 +/- 0.5 degrees . In the comparison MDCT versus invasive angiography, the 45 angles were significantly lager in MDCT (mean: 66 +/- 20 degrees vs. 56 +/- 24 degrees , P = 0.027). Interobserver variability was significantly lower in MDCT (r = 0.91) than invasive angiography (r = 0.62). Analysis of the natural distribution of bifurcation angles by MDCT revealed average values of 80 +/- 27 degrees (LAD/LCX), 46 +/- 19 degrees (LAD/Diag1), 48 +/- 24 degrees (LCX/OM1), and 53 +/- 27 degrees (PDA/Rpld), respectively. CONCLUSION: MDCT allows assessment of coronary bifurcation angles with high accuracy, which may be of future potential for planning interventional treatment.

Coronary Angiography↗

Usefulness of multidetector row spiral computed tomography with 64- x 0.6-mm collimation and 330-ms rotation for the noninvasive detection of significant coronary artery stenoses.

Eighty-four patients with suspected coronary artery disease were studied to determine the accuracy of noninvasive coronary angiography using a multidetector computed tomographic scanner with 64- x 0.6-mm collimation and 330-ms gantry rotation. All coronary artery segments with a diameter >1.5 mm were assessed with respect to stenoses >50% decreased diameter. Results were compared with quantitative coronary angiographic findings. After exclusion of unevaluable coronary segments (4%), multidetector computed tomography demonstrated a sensitivity of 93%, a specificity of 97%, and a negative predictive value of 100% in a per-segment analysis. In a per-artery analysis, 15 of 336 arteries (4%) were unevaluable. Sensitivity and specificity in evaluable arteries were 95% and 93%, respectively. In a per-patient analysis (81 of 84 patients included), sensitivity and specificity were 96% and 91%, respectively.

Adult↗

Analysis of coronary calcifications versus Framingham and PROCAM risk assessment in patients with a first myocardial infarction.

UNLABELLED: We compared the extent of coronary calcifications as quantified by electron beam tomography (EBT) to the predicted 10-year cardiovascular event risk based on Framingham and PROCAM algorithms in patients with a first myocardial infarction (MI). METHODS: In 156 patients (56.7 +/- 22 years), EBT was performed <4 weeks after MI. Coronary calcifications were quantified using the "Agatston Score" and age-related calcium percentiles were determined. The predicted 10-year event risk was determined using Framingham and PROCAM algorithms. RESULTS: Coronary calcifications were present in 148 patients with a mean "Agatston Score" of 589.2 +/- 976. The "Agatston Score" was >400 in 44% and >90th percentile in 42% of the patients. Framingham risk was >20% in 32% and PROCAM risk was >20% in 28%. CONCLUSION: Coronary calcifications were detected in the vast majority of patients with a first MI, independent from the patient's age. The determination of age-related percentiles was superior to the Framingham or PROCAM algorithm.

Adult↗

Visualization of coronary artery anomalies by contrast-enhanced multi-detector row spiral computed tomography.

BACKGROUND: We investigated the potential of 16-slice multi-detector row spiral CT (MDCT) with retrospective ECG-gating for evaluation of coronary artery anomalies. METHODS: A total of 35 patients (23 men, 12 women, 19-81 years) in whom anomalous coronary arteries had been detected by invasive coronary angiography underwent MDCT (Sensation 16, Siemens, Germany). During one breathhold, a contrast-enhanced (90 ml, 5 ml/s) volume data set of the heart was acquired (16x0.75mm collimation, gantry rotation 375 ms). Images were reconstructed with a slice thickness of 1.0 mm in 0.5-mm intervals using retrospective ECG-gated reconstruction. The 35 data sets and 80 data sets of patients with angiographically normal coronary anatomy were analysed in random order concerning the origin and course of the coronary arteries. The results were compared to invasive coronary angiography. RESULTS: All patients with coronary artery anomalies and all controls with normal coronary anatomy were identified by MDCT. In addition, the origins and course concerning their anatomical relationship to adjacent cardiac structures were visualized in all patients, including right-sided origin of the left main (n=10), left anterior descending coronary artery (n=4) or left circumflex coronary artery (n=10); left-sided origin of the right coronary artery (n=6); four coronary fistula to the pulmonary artery (two from the left anterior descending, one from the right coronary artery, one from the left main), and one fistula from the circumflex coronary artery to the left atrium CONCLUSIONS: The study demonstrates that MDCT is a reliable noninvasive technique to identify and define anomalous coronary arteries and their course.

Adult↗

Comparison of the degree of coronary stenoses by multidetector computed tomography versus by quantitative coronary angiography.

Sixteen-slice multidetector computed tomography (MDCT) and quantitative coronary angiography (QCA) were performed in 29 patients. Quantification of the degree of luminal narrowing and lesion length measurements were performed independently on MDCT and QCA at 42 sites with sufficient computed tomographic image quality. The correlation between MDCT and QCA for quantifying the degree of stenosis was excellent (r2 = 0.93), although a systematic overestimation was observed by MDCT (bias 4% +/- 8%). The correlation between MDCT and QCA was moderate with respect to lesion length (r2 = 0.54). In the absence of severe calcifications or motion artifacts, MDCT permits noninvasive quantification of coronary stenosis.

Aged↗

Calcium concentration of individual coronary calcified plaques as measured by multidetector row computed tomography.

BACKGROUND: Characteristics of individual calcified plaques, especially calcium concentration (CC), may provide incremental value to global calcium scores in the assessment of plaque burden and risk of coronary events and evaluation of therapeutic intervention. In this study, therefore, we assessed the characteristics of individual calcified plaques and their relationship to other parameters derived from CT analysis of coronary calcium in a community-based cross-sectional cohort. METHODS AND RESULTS: Coronary artery calcium (CAC) was analyzed in 612 participants of the Framingham Heart Study (third-generation and offspring cohorts) using prospectively ECG-triggered multidetector CT. We determined the CC, Agatston score, calcified volume, and mineral mass of individual calcified plaques in each subject. Heterogeneity of CC was defined as the standard deviation of CC of all individual calcified plaques in a subject. CAC was detected in 274 of 605 subjects. After excluding 57 subjects (21%) because of motion artifacts, we identified a total of 956 calcified coronary plaques in 217 subjects (74 women, 143 men; mean age, 57.1+/-10.8 years) with detectable CAC and no image artifacts. CC of individual calcified plaques was independent of subject age (P=0.76) and sex (197.8+/-74.8 versus 183.6+/-52.8 mg/cm3 for men versus women; P=0.21). Among a subgroup of 125 subjects with multiple (> or =3) individual calcified plaques, CC was heterogeneous within individual subjects (mean SD of CC, 43.6+/-23.1 mg/cm3). The degree of heterogeneity of CC in these subjects was independent of age (P=0.60), sex (P=0.99), and number of plaques (P=0.06). CONCLUSIONS: The CC of individual calcified plaques is independent of age and sex but heterogeneous within a subject, which may reflect that the pathological process of calcified plaque formation and progression is the same in men and women regardless of age. CC may have incremental value to global calcium scores in the assessment of plaque burden and risk of coronary events and the evaluation of therapeutic intervention. Further studies are warranted to confirm that individual plaque analysis is preferable to global CAC scores to evaluate progression of atherosclerosis and to assess whether individual plaque analysis may be complementary to global CAC measures to assess coronary event risk.

Age Factors↗

Detection of coronary artery stenoses using multi-detector CT with 16 x 0.75 collimation and 375 ms rotation.

AIMS: Insufficient spatial and temporal resolutions have limited image quality and accuracy of multi-detector CT (MDCT) for coronary artery visualization and detection of stenoses. We assessed the accuracy of a new 16-slice scanner with 370 ms rotation and 0.75 mm collimation for detection of coronary stenoses using an analysis approach based on coronary artery segments. METHODS AND RESULTS: Fifty consecutive patients scheduled for diagnostic coronary angiography in stable clinical condition and sinus rhythm were enrolled. All patients with a heart rate > 60 b.p.m. received 100 mg atenolol p.o. and up to four doses of 5 mg metoprolol i.v. before the scan. MDCT was performed using 16 x 0.75 mm collimation, 120 kV, and ECG-gated tube current modulation. Ninety millilitres of contrast agent was injected intravenously. MDCT images were visually analysed using the 16-segment coronary artery model of the American Heart Association and compared with invasive, quantitative coronary angiography in a blinded fashion. A significant stenosis was assumed if the diameter reduction was > or = 50%. Mean heart rate was 58 b.p.m. during MDCT. After exclusion of two patients with not fully evaluable data sets, MDCT correctly identified at least one coronary stenosis in all 25 patients with significant coronary lesions in angiography and correctly demonstrated the absence of stenoses in 19/23 patients (sensitivity 100%, specificity 83%). Sensitivity and specificity for all 50 patients were 93 and 83%, respectively. On a per-segment basis, nine coronary segments distal of total occlusions and 128 coronary segments with a reference diameter < 1.5 mm were excluded from the analysis. Twenty-eight of the included 663 segments (4%) were unevaluable due to calcification or motion artefact. In the remaining 635 segments, 50/53 stenoses were detected by MDCT (sensitivity 94%, specificity 96%, negative predictive value 99%, positive predictive value 69%). CONCLUSION: Increasing temporal and spatial resolutions of MDCT lead to improved evaluation and diagnostic accuracy for detection of coronary stenoses.

Adult↗

Noninvasive evaluation of cardiac veins with 16-MDCT angiography.

OBJECTIVE: Anatomic mapping of the cardiac veins is important to guide transvenous therapeutic procedures such as biventricular pacing. As an alternative to invasive venography, we studied the feasibility of MDCT of the cardiac venous anatomy. CONCLUSION: Cardiac venous anatomy is variable. MDCT is a noninvasive method that allows detailed imaging of the cardiac venous anatomy, including small cardiac veins and thebesian valves. Therefore, cardiac MDCT may be a valuable tool for guiding procedures that involve the cardiac venous system.

Coronary Angiography↗

Comparison of measurement of cross-sectional coronary atherosclerotic plaque and vessel areas by 16-slice multidetector computed tomography versus intravascular ultrasound.

In 26 patients, 16-slice multidetector computed tomography (MDCT) with 0.75-mm collimation and intravascular ultrasound (IVUS) of 1 coronary artery were performed. At 100 sites within the coronary arteries, the measurement of cross-sectional luminal area and, if detectable, the cross-sectional area of atherosclerotic plaque was performed independently with IVUS and MDCT. The mean luminal area (r = 0.92), measured at 100 sites, and plaque area (r = 0.55), measured at 65 sites, were significantly correlated (p <0.001) between MDCT and IVUS. The mean luminal area and mean plaque area were slightly but significantly overestimated with MDCT. MDCT permits the noninvasive measurement of coronary cross-sectional luminal and plaque areas with moderate accuracy.

Coronary Angiography↗