PubMed Health⌕ Search

Biomedical subjects

Stephan Achenbach

Publications and source records attributed to Stephan Achenbach.

65 records · Page 4Linked to original sources

Clinical results of minimally invasive coronary angiography using computed tomography.

Fast, high-resolution CT techniques, such as EBCT and MDCT permit imaging of the coronary arteries. Continuous improvements in the capabilities of both technologies for visualization of the coronary lumen and detection of coronary artery stenoses are being made. Image quality currently is not robust enough in all patients to consider non-invasive coronary angiography by EBCT and MDCT a routine clinical tool. In selected patients and carefully performed, however, they show promise as means to exclude the presence of coronary artery stenoses in a non-invasive fashion. This may become a beneficial and important application of these technologies. Other possible applications pertain to smaller patient subsets, such as patients with anomalous coronary arteries, fistulas or aneurysms. The development of techniques to visualize non-calcified plaque is interesting with respect to assessment of coronary risk, but this requires further investigation.

Coronary Angiography↗

Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography.

RATIONALE AND OBJECTIVES: To compare the image quality of electron beam tomography (EBT) and multislice spiral CT (MSCT) for coronary artery visualization. MATERIALS AND METHODS: Two groups of 30 patients without coronary stenoses were studied by MSCT (4 x 1 mm collimation) or EBT (3 mm slice thickness). Contrast-to-noise ratio (CNR), overall length of the visualized arteries and vessel length free of motion artifacts were measured. RESULTS: Length of visualized arteries was equal in MSCT and EBT. In EBT, longer segments were depicted free of motion artifacts (MSCT: 73%, EBT: 92% of visualized length, P< 0.001) and CNR was significantly higher than in MSCT (15.4 vs. 9.0; P< 0.001). In both modalities, vessel diameters correlated closely to quantitative coronary angiography. CONCLUSIONS: EBT and MSCT permit reliable coronary artery visualization and measurement of vessel diameters. For the used scan protocol, MSCT images had a lower CNR and were more frequently affected by motion.

Aged↗

Diagnostic value of maximum intensity projections versus source images for assessment of contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography.

RATIONALE AND OBJECTIVES: We compared maximum intensity projections (MIP) versus original source images (SI) in respect to detection of coronary artery stenoses by means of magnetic resonance (MR) coronary angiography. METHODS: MR coronary angiography was performed on 61 patients. MIP and SI were independently evaluated as to presence of significant stenoses in the proximal and midcoronary segments and compared with x-ray angiography. RESULTS: A total of 315 of 427 (74%) coronary artery segments could be evaluated in MIP and 328 of 427 (77%) in SI. In segments able to be evaluated, MIP images demonstrated 84% (54/64) sensitivity and 87% (219/251) specificity, whereas SI images showed 85% (58/68) sensitivity and 90% (235/260) specificity. Overall accuracy was 87% (273/310) for MIP and 89% (293/328) for SI. There was no statistically significant difference between both modalities. CONCLUSIONS: The MIP reconstructions showed comparable accuracy to unprocessed SI. However, MIP postprocessing is compromised by a higher number of images that were unable to be evaluated due to overlap of coronary arteries with adjacent cardiac structures.

Algorithms↗

Coronary calcium quantification using various calibration phantoms and scoring thresholds.

RATIONALE AND OBJECTIVES: To compare scoring threshold and calibration method-dependent accuracy and variability of coronary calcium measurements by multidetector computed tomography (MDCT). METHODS: Ninety-five subjects were scanned with MDCT. We calculated Agatston score and volume score. Mineral mass (MM) was calculated using patient-based and scanner-based calibration methods. Accuracy of calibration was validated using artificial calcium cylinders. RESULTS: Patient-based and scanner-based calibration permitted accurate quantification of artificial calcium cylinders (bias: 0 mg and -2 mg). In the subjects, the mean relative difference of MM measurements performed at 90 and 130 Hounsfield units threshold (59%) was lower than for Agatston score (94%) and volume score (109%; P < 0.05). Patient-based and scanner-based calibration yielded systematically different MM measurements (bias: 22%). CONCLUSIONS: MM lowers threshold-dependent variability of coronary calcium measurements. Patient-based and scanner-based calibration allows accurate calcium quantification ex vivo but reveal systematic differences in subjects. Patient-based calibration may better account for subject size and composition.

Aged↗

Comparison of contrast-enhanced breath-hold and free-breathing respiratory-gated imaging in three-dimensional magnetic resonance coronary angiography.

Suppression of respiratory motion is one of the major challenges of magnetic resonance (MR) coronary angiography. Two approaches to compensate for respiratory motion have often been proposed: breath-hold (BH) and free-breathing respiratory-gated (FBRG) imaging. So far, however, these approaches have never been directly compared. MR coronary angiography was performed in 32 patients with suspected coronary artery disease. MR data were acquired using contrast-enhanced BH and FBRG 3-dimensional MR coronary angiographic techniques. MR images were compared with regard to image quality using quantitative parameters and with regard to accuracy for stenosis detection in the proximal and mid-coronary segments in comparison to x-ray angiography. With regard to image quality, BH was superior to FBRG. Signal-to-noise ratio was 29.1 +/- 10.7 for BH versus 18.8 +/- 9.7 for FBRG (p <0.05) and contrast-to-noise was 18.0 +/- 7.4 for BH versus 11.3 +/- 7.9 for FBRG (p </=0.05). One hundered seventy-one of 224 coronary artery segments (76%) were evaluable in BH compared with 155 of 224 in FBRG (69%). In the evaluable segments, BH demonstrated a sensitivity of 87% (26 of 30 stenoses detected) and specificity of 92% (129 of 141 nonstenotic segments correctly identified), whereas FBRG showed a sensitivity of 60% (15 of 25) and specificity of 89% (115 of 130). Overall accuracy was 91% (155 of 171) for BH and 84% (130 of 155) for FBRG. Sensitivity was significantly higher for BH (p = 0.0320), whereas specificity and overall accuracy were not significantly different. Thus, contrast-enhanced BH MR coronary angiography compares favorably to FBRG imaging with regard to image quality and detection of coronary stenoses.

Adult↗

Influence of lipid-lowering therapy on the progression of coronary artery calcification: a prospective evaluation.

BACKGROUND: Coronary calcification measured by fast computed tomography techniques is a surrogate marker of coronary atherosclerotic plaque burden. In a cohort study, we prospectively investigated whether lipid-lowering therapy with a cholesterol synthesis enzyme inhibitor reduces the progression of coronary calcification. METHODS AND RESULTS: In 66 patients with coronary calcifications in electron beam tomography (EBT), LDL cholesterol >130 mg/dL, and no lipid-lowering treatment, the EBT scan was repeated after a mean interval of 14 months and treatment with cerivastatin was initiated (0.3 mg/d). After 12 months of treatment, a third EBT scan was performed. Coronary calcifications were quantified using a volumetric score. Cerivastatin therapy lowered the mean LDL cholesterol level from 164+/-30 to 107+/-21 mg/dL. The median calcified volume was 155 mm3 (range, 15 to 1849) at baseline, 201 mm3 (19 to 2486) after 14 months without treatment, and 203 mm3 (15 to 2569) after 12 months of cerivastatin treatment. The median annualized absolute increase in coronary calcium was 25 mm3 during the untreated versus 11 mm3 during the treatment period (P=0.01). The median annual relative increase in coronary calcium was 25% during the untreated versus 8.8% during the treatment period (P<0.0001). In 32 patients with an LDL cholesterol level <100 mg/dL under treatment, the median relative change was 27% during the untreated versus -3.4% during the treatment period (P=0.0001). CONCLUSIONS: Treatment with the cholesterol synthesis enzyme inhibitor cerivastatin significantly reduces coronary calcium progression in patients with LDL cholesterol >130 mg/dL.

Adult↗

A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

RATIONALE AND OBJECTIVES: To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS: One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent). MRI was performed using respiratory-gated sequences (24-48 cross-sections, 2-mm slice thickness, 20 mL Gd-DTPA). EBT and MRI images were evaluated concerning high-grade post-PTCA restenosis (> or = 70%) and validated against coronary angiography. RESULTS: In EBT, 28 patients and in MRI, 31 patients were not evaluable. In the remaining patients, sensitivity for restenosis detection was 90% in EBT (17/19) and 73% in MRI (11/15; P = 0.370). In EBT, specificity was significantly higher (66% vs. 49%, P = 0.043). Overall accuracy was 71% for EBT and 53% for MRI (P = 0.014). CONCLUSIONS: For the detection of high-grade restenosis after PTCA, EBT demonstrated significantly higher accuracy than MRI.

Angioplasty, Balloon, Coronary↗

Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: influence of heart rate on image quality and stenosis detection.

OBJECTIVE: Although multidetector CT (MDCT) with retrospectively ECG-gated image reconstruction has been shown to permit noninvasive visualization of the coronary arteries, the 125-250 msec required for image acquisition frequently causes motion artifacts. We investigated the influence of a patient's heart rate on the presence of motion artifacts and on accuracy of stenosis detection on contrast-enhanced MDCT. MATERIALS AND METHODS: In 100 patients, MDCT was performed, and ECG-gated cross-sectional images were retrospectively reconstructed. From the 10 data sets obtained for each patient (reconstructed at 0-90% of the cardiac cycle in increments of 10%), we chose the best data set for every coronary artery. The images of the arteries were evaluated for occurrence of artifacts and the presence of high-grade stenosis (diameter reduction exceeding 70%) or occlusions. MDCT results were compared with coronary angiographic findings. RESULTS: Of the 400 coronary arteries, 115 (29%) could not be evaluated because of motion artifacts (n = 84) or other reasons (n = 31). Overall, 51 (49%) of 104 stenoses were revealed on MDCT. For detecting stenosis in those arteries that we could evaluate, MDCT had a sensitivity of 91% (51 of 56 stenoses detected) and a specificity of 89%. As the heart rate increased, the number of arteries that could be evaluated decreased, and overall sensitivity for stenosis detection decreased from 62% (heart rate < or = 70 beats per minute) to 33% (heart rate > 70 beats per minute). CONCLUSION: MDCT can reveal coronary stenoses, but the usefulness of MDCT as an aid in accurately evaluating stenoses decreases as a patient's heart rate increases.

Adult↗

Current and future status on cardiac computed tomography imaging for diagnosis and risk stratification.

Computed tomography (CT) permits cross-sectional imaging with high spatial resolution and has, during the past years, undergone tremendous development mainly concerning the temporal resolution. By use of multidetector spiral technology, as well as electrocardiography-gated image acquisition and reconstruction techniques, 16- and 64-slice CT permits visualization of cardiac morphology and function. In this context, however, CT imaging does not play a major clinical role because other imaging methods (mainly echocardiography) usually provide all necessary information. Under certain conditions, multidetector CT also permits visualization of the coronary arteries. Detection of coronary calcification, as well as coronary CT angiography, can provide clinically useful information if applied to suitable patient groups. It is foreseeable that CT angiography will become part of the routine workup in some subsets of patients with suspected coronary artery disease, either alone or in combination with other imaging techniques. Among the limitations of cardiac CT are the requirement of a regular (and preferably low) heart rate, the associated x-ray exposure, and the need for an iodinated contrast agent for most applications. It is important to note that reliable and accurate results will require use of the most advanced CT scanner technology, optimal image quality, and sufficient experience in the acquisition and interpretation of cardiac CT data sets.

Angiography↗

Tomographic coronary angiography by EBCT and MDCT.

Fast, cross-sectional computed tomography (CT) imaging permits visualization of the coronary artery lumen after intravenous injection of contrast agent. Electron beam CT and multidetector row spiral CT have both been shown to allow detection of coronary artery stenoses with high sensitivity and specificity in selected patient subsets. However, limitations of image quality may render some coronary artery segments unevaluable, in most cases because of severe calcification or remaining motion artifacts. In the future, these imaging modalities may play a clinically important role in ruling out coronary artery stenoses, especially in patients with relatively low likelihood of disease. Other applications include the analysis of bypass patency and evaluation of coronary anomalies.

Calcinosis↗