PubMed Health⌕ Search

Biomedical subjects

Stephan Achenbach

Publications and source records attributed to Stephan Achenbach.

At least 55 records · Page 3Linked to original sources

Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease: patient-versus segment-based analysis.

BACKGROUND: In this study, we investigated the diagnostic value and limitations of multidetector computed tomography (MDCT)-based noninvasive detection of significant obstructive coronary artery disease (CAD) in a consecutive high-risk patient population with inclusion of all coronary segments. METHODS AND RESULTS: In a prospective, blinded, standard cross-sectional technology assessment, a cohort of 33 consecutive patients with a positive stress test result underwent 16-slice MDCT and selective coronary angiography for the detection of significant obstructive CAD. We assessed the diagnostic accuracy of MDCT in a segment-based and a patient-based model and determined the impact of stenosis location and the presence of calcification on diagnostic accuracy in both models. Analysis of all 530 coronary segments demonstrated moderate sensitivity (63%) and excellent specificity (96%) with a moderate positive predictive value of 64% and an excellent negative predictive value (NPV) of 96% for the detection of significant coronary stenoses. Assessment restricted to either proximal coronary segments or segments with excellent image quality (83% of all segments) led to an increase in sensitivity (70% and 82%, respectively), and high specificities were maintained (94% and 93%, respectively). In a patient-based model, the NPV of MDCT for significant CAD was limited to 75%. Coronary calcification was the major cause of false-positive findings (94%). CONCLUSIONS: For all coronary segments included, 16-slice MDCT has moderate diagnostic value for the detection of significant obstructive coronary artery stenosis in a population with a high prevalence of CAD. The moderate NPV of patient-based detection of CAD suggests a limited impact on clinical decision-making in high-risk populations.

Coronary Angiography↗

Epidemiology and association of vascular and valvular calcium quantified by multidetector computed tomography in elderly asymptomatic subjects.

The epidemiology of and association between vascular and valvular calcium as quantified by multidetector computed tomography (MDCT) were studied in 416 elderly subjects with no history of coronary artery disease. Coronary calcium (CC), descending thoracic aortic calcium (DTAC), aortic valve calcium (AVC), and mitral valve calcium (MVC) were present in 282 (68%), 214 (51%), 152 (37%), and 68 (16%) subjects, respectively. Multiple logistic regression analysis showed that after adjusting for age and gender, subjects with AVC (odds ratio [OR] 2.3), MVC (OR 2.81), and DTAC (OR 2.79) were independently and significantly more likely to have CC. Further evidence is provided for the notion that calcifications in those regions are associated and that MDCT can be used as a tool for the global assessment of vascular and valvular calcium.

Age Distribution↗

Acute myocardial infarction: contrast-enhanced multi-detector row CT in a porcine model.

PURPOSE: To assess the role of contrast material-enhanced retrospectively electrocardiographically (ECG) gated multi-detector row computed tomography (CT) in the detection of acute myocardial infarction in a porcine model of total coronary occlusion. MATERIALS AND METHODS: Seven Yorkshire farm pigs were studied with contrast-enhanced retrospectively ECG-gated multi-detector row CT 3 hours after total occlusion of the distal left anterior descending artery (n = 5) or the second diagonal branch (n = 2). Reformatted short-axis end-systolic and end-diastolic CT data sets were assessed for myocardial perfusion deficits, coronary occlusion, and abnormal myocardial wall motion. Perfusion deficits were compared with microsphere-determined blood flow and triphenyltetrazolium chloride (TTC)-stained tissue samples for infarct assessment by using Bland-Altman analysis and analysis of variance. RESULTS: Myocardial perfusion deficits, occlusion of the left anterior descending artery or second diagonal branch, and akinesis of the infarcted segment were identified in all five animals that completed the study. One animal died, and one data set had nondiagnostic image quality. The CT end-diastolic (mean, 16.1% +/- 4.8 [SD]; range, 8.6%-22.2%) and end-systolic (mean, 17.0% +/- 6.4; range, 8.7%-26.8%) volume of perfusion deficit was similar to that of infarcted tissue at TTC staining (mean, 13.6% +/- 6.0; range, 7.8%-30.9%). Infarcted myocardium at CT demonstrated a 76.1% reduction in microsphere-determined blood flow and a significant reduction of myocardial CT attenuation compared with normal myocardium (P <.01). Myocardial wall motion analysis demonstrated absence of systolic wall thickening in infarcted myocardium. CONCLUSION: Multi-detector row CT with retrospective ECG gating permits the detection and further characterization of acute myocardial infarction in a porcine model of complete coronary occlusion.

Animals↗

Left ventricular thin-point detection using multidetector spiral computed tomography.

We systematically studied the thickness of the myocardium in the left ventricular apical region in patients without a history of myocardial infarction and with no hemodynamically significant coronary artery disease, using contrast-enhanced multidetector spiral computed tomography with submillimeter collimation. We confirmed previous pathology data and reliably detected a small confined region of the normal apical myocardium with a thickness of <or=3 mm, i.e., the left ventricular thin point.

Aged↗

Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography.

OBJECTIVES: This study was designed to investigate whether contrast-enhanced multidetector spiral CT (MDCT) permits assessment of remodeling in coronary atherosclerotic lesions. BACKGROUND: With sufficient image quality, MDCT permits noninvasive visualization of the coronary arteries, but its ability to assess remodeling has not been evaluated. METHODS: Out of 102 patients in whom MDCT (16-slice scanner, intravenous contrast, 0.75-mm collimation, 420 ms rotation) was performed before invasive coronary angiography, 44 patients with high-quality MDCT data sets showing atherosclerotic plaque in a proximal coronary artery segment were chosen for evaluation. In multiplanar reconstructions orthogonal to the coronary artery, the cross-sectional vessel area was measured for the respective lesion and for a reference segment proximal to the lesion. The "Remodeling Index" was calculated by dividing the vessel area in the lesion by the reference segment. Results were correlated to the presence of stenosis (>50% diameter reduction) in invasive angiography. In a subset of 13 patients, MDCT measurements were verified by IVUS. RESULTS: Reference vessel area was not significantly different between nonstenotic versus stenotic lesions (20 +/- 8 mm(2), n = 23 vs. 22 +/- 8 mm(2), n = 21). The mean Remodeling Index was significantly higher in nonstenotic than in stenotic lesions (1.3 +/- 0.2 vs. 1.0 +/- 0.2, p < 0.001). In five stenotic lesions, "negative remodeling" (Remodeling Index < or = 0.95) was observed. Cross-sectional vessel areas and Remodeling Indices measured by MDCT correlated closely to IVUS (r(2) = 0.77 and r(2) = 0.82, respectively). CONCLUSIONS: Multidetector spiral CT may permit assessment of remodeling of coronary atherosclerotic lesions in selected data sets of sufficient quality.

Coronary Angiography↗

Imaging of coronary atherosclerosis using computed tomography: current status and future directions.

Computed tomography (CT) imaging of the coronary arteries, using either electron beam tomography (EBT) or multidetector row CT (MDCT), offers two possibilities to assess coronary atherosclerosis. Without injection of contrast agent, coronary calcifications can be detected and quantified. Their presence and extent correlates to the presence and amount of coronary atherosclerotic plaque. Prospective studies have demonstrated a high predictive value concerning the occurrence of coronary artery disease events and overall mortality. An emerging consensus seems to indicate that calcium imaging may be clinically useful in patients at intermediate risk for coronary artery disease events as determined based on traditional risk factors. In addition, recent studies have shown that after injection of contrast agent and using high-resolution scan protocols, the visualization of noncalcified plaque is also possible with CT techniques. However, data on the accuracy of plaque detection, quantification of plaque volume, and characterization of plaque (eg, lipid-rich vs fibrous) is currently limited, and the prognostic significance of noncalcifed coronary atherosclerotic plaque detection is unclear.

Coronary Artery Disease↗

Quantification of aortic valve calcification with electron beam tomography: a histomorphometric validation study.

RATIONALE AND OBJECTIVES: The exact quantification of the amount of calcification in aortic valves may be useful for the identification of risk factors for the progression of aortic valve calcification and to evaluate new therapeutic approaches for aortic valve disease. Electron beam tomography (EBT) allows the in vivo detection of calcifications in coronary vessels and in the aortic valve. The aim of this study was to validate the quantification of aortic valve calcification by EBT with in vivo and in vitro investigations. METHODS: In 15 patients (aortic stenosis in 13, aortic regurgitation in 2 cases), EBT was performed before aortic valve replacement (40 cross sections, 3-mm slice thickness, matrix 512 x 512, field of view 28 cm, ECG trigger at 40% of the cardiac cycle). EBT was repeated on the explanted aortic valve using the same protocol. In both data sets, the amount of aortic valve calcification was determined using a volumetric score. In serial cuts of the explanted valve (distance 1 mm), the calcified volume was determined by an independent investigator using histomorphometric analysis. RESULTS: The mean calcified volume of the aortic valves as quantified by EBT was 1650.0 +/- 1401.0 mmł in vivo (EBT1) and 1544.4 +/- 1266.5 mmł in vitro (EBT2). Histomorphometric analysis showed a mean calcified volume of 1555.7 +/- 1272.5 mmł. The mean difference between EBT1 and EBT2 was 4.2 +/- 14.7%, between EBT1 and histomorphometry 3.6 +/- 12.1%, and between EBT2 and histomorphometry -0.5 +/- 5.9%. CONCLUSION: EBT allows accurate in vivo quantification of aortic valve calcifications.

Aged↗

Association of cardiovascular risk factors to aortic valve calcification as quantified by electron beam computed tomography.

OBJECTIVE: To analyze the association among aortic valve calcification, cardiovascular risk factors, and coronary artery calcification using electron beam computed tomography (EBCT). PATIENTS AND METHODS: We analyzed cardiac EBCT data obtained for coronary calcium detection in 1000 consecutively enrolled patients (mean +/- SD age, 57.1 +/- 10 years; 69% men) between January 1, 1998, and July 23, 2001. In all patients, atherosclerotic risk factors (hyperlipidemia, hypertension, diabetes, smoking, and family history of coronary artery disease) were documented. With EBCT, the amount of coronary calcification was determined using the Agatston score, and the amount of aortic valve calcification was measured using a volumetric score. RESULTS: Aortic valve calcification was detected in 177 (17.7%) of the total patient group and was found more frequently in patients with coronary calcification (20.5% in patients with coronary calcium vs 3.8% in patients without coronary calcium; P < .001), hyperlipidemia (19.5% vs 6.5%; P < .001), hypertension (21.7% vs 13.9%; P = .01), or diabetes (30.7% vs 16.6%; P = .002). The volume of aortic valve calcification was significantly higher in patients with vs without hyperlipidemia (P < .001), hypertension (P = .002), and diabetes (P = .001). In a multivariable logistic regression analysis, adjusted for age and sex, hyperlipidemia (P = .001) and the presence of coronary calcification (P < .001) were significant predictors of aortic valve calcification. CONCLUSION: A significant association exists among atherosclerotic risk factors, coronary calcification, and the presence and amount of aortic valve calcification.

Aged↗

Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound.

BACKGROUND: We investigated the ability of multidetector spiral computed tomography (MDCT) to detect atherosclerotic plaque in nonstenotic coronary arteries. METHODS AND RESULTS: In 22 patients without significant coronary stenoses, contrast-enhanced MDCT (0.75-mm collimation, 420-ms rotation) and intravascular ultrasound (IVUS) of one coronary artery were performed. A total of 83 coronary segments were imaged by IVUS (left main, 19; left anterior descending, 51; left circumflex, 4; right coronary, 9). MDCT data sets were evaluated for the presence and volume of plaque in the coronary artery segments. Results were compared with IVUS in a blinded fashion. For the detection of segments with any plaque, MDCT had a sensitivity of 82% (41 of 50) and specificity of 88% (29 of 33). For calcified plaque, sensitivity was 94% (33 of 36) and specificity 94% (45 of 47). Coronary segments containing noncalcified plaque were detected with a sensitivity of 78% (35 of 45) and specificity of 87% (33 of 38), but presence of exclusively noncalcified plaque was detected with only 53% sensitivity (8 of 15). If analysis was limited to the 41 proximal segments (segments 1, 5, 6, and 11 according to American Heart Association classification), sensitivity and specificity were 92% and 88% for any plaque, 95% and 91% for calcified plaque, and 91% and 89% for noncalcified plaque. MDCT substantially underestimated plaque volume per segment as compared with IVUS (24+/-35 mm3 versus 43+/-60 mm3, P<0.001). CONCLUSIONS: The results indicate the potential of MDCT to detect coronary atherosclerotic plaque in patients without significant coronary stenoses. However, further improvements in image quality will be necessary to achieve reliable assessment, especially of noncalcified plaque throughout the coronary tree.

Calcinosis↗

Relation between coronary calcium and 10-year risk scores in primary prevention patients.

In 380 patients, coronary calcifications were quantified by electron beam tomography and compared with the predicted 10-year cardiovascular event risk determined by the Framingham equation, Adult Treatment Panel III tables, and the PROCAM algorithm. The correlation between the amount of calcium and the predicted cardiac event risk was low (correlation coefficient range 0.19 to 0.28). The assessment of coronary calcium may thus potentially yield information that is additive to the analysis of traditional risk factors.

Age Factors↗

Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography.

OBJECTIVE: The purpose of this study was to provide a comprehensive review of the literature relating to electron beam angiography (EBA), magnetic resonance angiography, and spiral computed tomography, currently the three most promising noninvasive methods to visualize obstructions in the coronary tree. BACKGROUND: Given the high costs and invasiveness of coronary angiography, there is increased interest in noninvasive coronary angiography, which has made great strides to become a clinically useful tool to augment conventional coronary angiography (CCA). METHODS: MEDLINE searches were performed to include all articles related to noninvasive angiography utilizing either magnetic resonance imaging (MRI), multi-row detector spiral computed tomography (MDCT), and electron beam tomography (EBT). Weighted analysis was performed to define the published sensitivity and specificity for each technique. RESULTS: Electron beam angiography (EBA) provides an overall sensitivity of 87% and specificity of 91% for the detection of obstructive coronary artery disease (CAD). Four-level MDCT data demonstrated an overall sensitivity of 59% and specificity of 89%, with higher accuracy in two recent studies of 16-level detector devices. Magnetic resonance angiography demonstrated sensitivity for detection of obstructive CAD of 77% and specificity of 71%. CONCLUSIONS: Noninvasive coronary angiography is a rapidly developing technique and currently not an alternative to CCA in all cases. All three methods are currently used clinically in certain centers with appropriate expertise. Selective use should prove both cost-effective and provide a safer, less-invasive method for patients to determine the need for medical versus revascularization therapy.

Coronary Disease↗

Quantitative parameters of image quality in multidetector spiral computed tomographic coronary imaging with submillimeter collimation.

Multidetector computed tomography (MDCT) permits visualization of the coronary arteries, but limited spatial and temporal resolution can lead to artifacts. We quantitatively evaluated the image quality that can be obtained with the latest generation of MDCT scanners with submillimeter collimation and increased gantry rotation speed. Thirty patients with angiographically proved absence of significant coronary artery stenoses (mean age 56 +/- 13 years, mean heart rate 62 +/- 13 beats/min) were studied by MDCT (12 x 0.75 mm collimation, 420-ms tube rotation, 210-ms temporal resolution, 500 mA, 120 kVp, retrospective electrocardiographic gating). In multiplanar reconstructions of the 4 major coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery), the overall visualized vessel length and the length of segments without motion artifacts were measured. Vessel diameters at 8 predefined locations were measured in MDCT maximum intensity projections and in corresponding invasive angiograms. The mean lengths of visualized coronary arteries were left main 13 +/- 6 mm, left anterior descending 138 +/- 39 mm, left circumflex 84 +/- 34 mm, and right coronary artery 155 +/- 41 mm. On average, 93 +/- 13% of the total visualized vessel length was depicted without motion artifacts (left main 100 +/- 0%, left anterior descending 93 +/- 12%, left circumflex 91 +/- 17%, and right coronary artery 87 +/- 14%). The percentage of vessel length visualized free of motion artifacts was significantly higher in patients with a heart rate </=60 beats/min compared with patients with a heart rate >60 beats/min (96 +/- 8% vs 89 +/- 17%, p <0.05). Vessel diameters in MDCT correlated closely to quantitative coronary angiography (R(2) 0.83 to 0.87). In conclusion, MDCT with submillimeter collimation and improved temporal resolution permits reliable visualization of the vessel lumen and accurate measurements of vessel dimensions.

Analysis of Variance↗

Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

BACKGROUND: We analyzed the accuracy of multi-detector row spiral computed tomography (MDCT) using a 16-slice CT scanner with improved spatial and temporal resolution, as well as routine premedication with beta-blockers for detection of coronary stenoses. METHODS AND RESULTS: Seventy-seven patients with suspected coronary disease were studied by MDCT (12x0.75-mm cross-sections, 420 ms rotation, 100 mL contrast agent IV at 5 mL/s). Patients with a heart rate above 60/min received 50 mg atenolol before the scan. In axial MDCT images and multiplanar reconstructions, all coronary arteries and side branches with a diameter of 1.5 mm or more were assessed for the presence of stenoses exceeding 50% diameter reduction. In comparison to invasive coronary angiography, MDCT correctly classified 35 of 41 patients (85%) as having at least 1 coronary stenosis and correctly detected 57 of 78 coronary lesions (73%). After excluding 38 of 308 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 77 patients) classified as unevaluable by MDCT (12%), 57 of 62 lesions were detected, and absence of stenosis was correctly identified in 194 of 208 arteries (sensitivity: 92%; specificity: 93%; accuracy: 93%; positive and negative predictive values: 79% and 97%). CONCLUSIONS: MDCT coronary angiography with improved spatial resolution and premedication with oral beta-blockade permits detection of coronary artery stenoses with high accuracy and a low rate of unevaluable arteries.

Adrenergic beta-Antagonists↗

[Clinical Use of Multi-Slice CT Coronary Angiography].

As compared to conventional CT scanners, multi-slice spiral CT (MSCT) has improved temporal and spatial resolution. Dedicated image reconstruction algorithms permit to create cross-sectional images with a temporal resolution of approximately 150-250 ms, and a slice thickness of 0.75-1.3 mm (see Figure 1). In addition, image reconstruction can be synchronized to the ECG. This permits to use MSCT for visualization of the coronary artery lumen and detection of stenosis (see Figures 2 and 3). Various post-processing techniques can be used to display the coronary arteries. A low heart rate has been identified as an important prerequisite to obtain a sufficiently high image quality, and most authors recommend routine use of beta blocker premedication. Comparisons of 4-slice MSCT to invasive angiography concerning the detection of hemodynamically relevant coronary artery stenoses have resulted in sensitivities ranging from 72-93% and specificities ranging from 84-98%. However, up to 32% of all coronary segments had to be excluded from evaluation due to impaired image quality, in most cases due to severe calcification or insufficient suppression of motion artifacts. Initial results obtained with 16-slice MSCT scanners, which provide somewhat higher temporal and--through decreased slice thickness--improved spatial resolution, show promise that diagnostic accuracy may be increased while the number of coronary artery segments with nondiagnostic image quality may be reduced as compared to the prior generation of 4-slice scanners. Further studies are necessary to identify patient subgroups which might benefit from MSCT "noninvasive coronary angiography" in a clinical setting.

Algorithms↗