PubMed Health⌕ Search

Biomedical subjects

Stephan Windecker

Publications and source records attributed to Stephan Windecker.

At least 37 records · Page 2Linked to original sources

Implantation of a second closure device in patients with residual shunt after percutaneous closure of patent foramen ovale.

Percutaneous closure of patent foramen ovale (PFO) in patients with presumed paradoxical embolism yields complete occlusion in > 90% of patients using contemporary closure devices. Patients with a residual shunt after percutaneous PFO closure have been found at increased risk for recurrent paradoxical events. Treatment options for such patients include medical treatment using antiplatelet drugs or oral anticoagulation, surgical device removal and patch closure, and percutaneous implantation of a second closure device. We report our experience with implantation of a second closure device in 10 patients with more than a minimal residual shunt < or = 6 months after percutaneous PFO closure. Procedure and fluoroscopy times were similar for the initial and repeat intervention (32 vs. 30 min and 5 vs. 6 min, respectively; P = NS). There were no procedural complications during implantation of the second closure device. Follow-up transesophageal echocardiography 6 months after the second percutaneous intervention revealed complete PFO closure in nine (90%) patients. Therefore, implantation of a second closure device in patients with persistence of more than a residual shunt after percutaneous PFO closure appears safe and effective.

Adult↗

Coronary collateral perfusion in patients with coronary artery disease: effect of metoprolol.

BACKGROUND: The use of ultrathin Doppler angioplasty guidewires has made it possible to measure collateral flow quantitatively. Pharmacologic interventions have been shown to influence collateral flow and, thus, to affect myocardial ischaemia. METHODS: Twenty-five patients with coronary artery disease undergoing PTCA were included in the present analysis. Coronary flow velocities were measured in the ipsilateral (n = 25) and contralateral (n = 6; two Doppler wires) vessels during PTCA with and without i.v. adenosine (140 microg/kg.min) before and 3 min after 5 mg metoprolol i.v., respectively. The ipsilateral Doppler wire was positioned distal to the stenosis, whereas the distal end of the contralateral wire was in an angiographically normal vessel. The flow signals of the ipsilateral wire were used to calculate the collateral flow index (CFI). CFI was defined as the ratio of flow velocity during balloon inflation divided by resting flow. RESULTS: Heart rate and mean aortic pressure decreased slightly (ns) after i.v. metoprolol. The collateral flow index was 0.25+/-0.12 (one fourth of the resting coronary flow) during the first PTCA and 0.27+/-0.14 (ns versus first PTCA) during the second PTCA, but decreased with metoprolol to 0.16+/-0.08 (p<0.0001 vs. baseline) during the third PTCA. CONCLUSIONS: Coronary collateral flow increased slightly but not significantly during maximal vasodilatation with adenosine but decreased in 23 of 25 patients after i.v. metoprolol. Thus, there is a reduction in coronary collateral flow with metoprolol, probably due to an increase in coronary collateral resistance or a reduction in oxygen demand.

Adolescent↗

Risk of decompression illness among 230 divers in relation to the presence and size of patent foramen ovale.

BACKGROUND: The risk of developing decompression illness (DCI) in divers with a patent foramen ovale (PFO) has not been directly determined so far; neither has it been assessed in relation to the PFO's size. METHODS: In 230 scuba divers (age 39+/-8 years), contrast trans-oesophageal echocardiography (TEE) was performed for the detection and size grading (0-3) of PFO. Prior to TEE, the study individuals answered a detailed questionnaire about their health status and about their diving habits and accidents. For inclusion into the study, > or =200 dives and strict adherence to decompression tables were required. RESULTS: Sixty-three divers (27%) had a PFO. Overall, the absolute risk of suffering a DCI event was 2.5 per 10(4) dives. There were 18 divers (29%) with, and 10 divers (6%) without, PFO who had experienced > or =1 major DCI events P=0.016. In the group with PFO, the incidence per 10(4) dives of a major DCI, a DCI lasting longer than 24 h and of being treated in a decompression chamber amounted to 5.1 (median 0, interquartile range [IQR] 0-10.0), 1.9 (median 0, IQR 0-4.0) and 3.6 (median 0, IQR 0-9.8), respectively and was 4.8-12.9-fold higher than in the group without PFO (P<0.001). The risk of suffering a major DCI, of a DCI lasting longer than 24 h and of being treated by recompression increased with rising PFO size. CONCLUSION: The presence of a PFO is related to a low absolute risk of suffering five major DCI events per 10(4) dives, the odds of which is five times as high as in divers without PFO. The risk of suffering a major DCI parallels PFO size.

Decompression Sickness↗

Clinical and angiographic results after mechanical connection for distal anastomosis in coronary surgery.

BACKGROUND: Sutureless anastomotic devices are of increasing interest in cardiovascular surgery. We investigated the stainless steel clip system of St Jude Medical/Anastomotic Technology Group (Maple Grove, Minn) to connect saphenous vein grafts with coronary arteries. METHODS: Forty-five patients were enrolled in this feasibility study performed on patients who had on-pump coronary artery bypass grafting, but 32 patients only received 1 distal anastomosis with this investigational device (2.5 mm [n = 14] and 2.0 mm [n = 18]). Thirteen were excluded because target vessels were too small, calcified, or tortuous. The system consists of an expandable clip mounted on a balloon catheter; delivery is obtained during balloon inflation. The main differences between the 2.5-mm and 2.0-mm devices are different loading and deployment in smaller coronary arteries for the 2.0-mm device. RESULTS: A connecting device was deployed on the right coronary artery in 14 patients, the posterior descending branch in 12 patients, the obtuse marginal in 5 patients, and the posterolateral branch in 1 patient. Perfect hemostasis of the sutureless connector anastomosis was obtained in 28 patients. Three connectors were removed because of minor leakage at the connection site, and 1 connector was removed because of mismanipulation after successful deployment. Hand-sewn anastomosis was performed at the same arteriotomy site. Intraoperative flow was assessed by the transit time method and averaged 71 +/- 24 mL/min. One patient died of neurologic injury; the connector was patent at autopsy. One patient had a perioperative myocardial infarction. There was no adverse cardiac event in the remaining patients. All patients underwent clinical follow-up after 6 and 12 months and 35 angiograms were available in 21 patients: after 3 and 6 months, 17 anastomoses were patent and the saphenous vein graft was occluded in 4 patients. CONCLUSIONS: The coronary connector system from St Jude Medical/Anastomotic Technology Group allows consistently uniform sutureless connection between the saphenous vein graft and coronary artery. Loading and deployment require careful training. This technology is under constant development and may give a significant boost to less invasive coronary revascularization techniques.

Aged↗

Early exercise after coronary stenting is safe.

OBJECTIVES: In this study, we sought to assess safety of symptom-limited exercise stress tests the day after coronary stenting. BACKGROUND: Isolated cases of coronary stent thrombosis have been linked to early exercise stress testing, thereby questioning the safety of unrestricted physical activity after the coronary procedure. METHODS: At a single center, 1,000 patients were randomized to a symptom-limited stress test the day after coronary stenting or no stress test. The antiplatelet regimen consisted of acetylsalicylic acid and postprocedural ticlopidine or clopidogrel. The primary end point of the study was the incidence of clinical stent thrombosis at 14 days. The secondary end point was the occurrence of access site complications. RESULTS: Clinical stent thrombosis occurred in five patients (1%) undergoing stress test and in five patients (1%) randomized to no stress test (p = 1.0). Access site complications were detected in 4% and 5.2% of cases, respectively (p = 0.37). CONCLUSIONS: Symptom-limited exercise stress testing the day after coronary stenting does not increase the risk of clinical stent thrombosis or access site complications. Further investigations on safety of early vigorous exercise after coronary stenting in a non-supervised setting are warranted.

Aged↗

Is there functional collateral flow during vascular occlusion in angiographically normal coronary arteries?

BACKGROUND: Thus far, it is unknown whether there is functional collateral flow through preexisting anastomoses in patients with angiographically normal coronary arteries. Such preformed coronary collateral vessels could form the basis for subsequently developing protective natural bypasses in the presence of coronary artery disease. METHODS AND RESULTS: Among 100 patients, the collateral flow index (CFI) was measured in coronary arteries without stenotic lesions. The CFI was determined by simultaneous measurement of mean aortic pressure, central venous pressure, and coronary wedge pressure via a sensor-tipped guidewire at the end of a 1-minute balloon occlusion. Patients were divided in 2 groups according to complete angiographic absence (51 patients) or partial presence (49 patients) of stenotic lesions in coronary arteries other than that undergoing collateral measurement. CFI in all patients (61+/-10 years; men/women, 69/31) amounted to 0.18+/-0.08 (range, 0.04 to 0.36). It showed a normal Gaussian frequency distribution; 22 individuals had a CFI > or =0.25, a value that was empirically found to represent well-developed collaterals protective against myocardial ischemia during coronary occlusion. Accordingly, 17 patients did not reveal signs of myocardial ischemia during coronary balloon occlusion, as assessed from an intracoronary ECG, and 26 patients did not experience angina pectoris during occlusion. CONCLUSIONS: In humans with angiographically normal coronary arteries, there are functional collateral vessels to the extent that one fifth to one quarter of them do not show signs of myocardial ischemia during brief vascular occlusions.

Angioplasty, Balloon, Coronary↗

Low pro-brain natriuretic peptide levels predict benign clinical outcome in acute pulmonary embolism.

BACKGROUND: The role of pro-brain natriuretic peptide (proBNP) for the prediction of clinical outcome has not been examined in patients with acute pulmonary embolism (PE). METHODS AND RESULTS: ProBNP levels were measured in 73 patients with acute PE within 4 hours of admission. Adverse clinical outcome was defined as in-hospital death or the need for at least 1 of the following: cardiopulmonary resuscitation, mechanical ventilation, pressors, thrombolysis, catheter fragmentation, or surgical embolectomy. In the 53 patients with a benign clinical outcome, proBNP (median 121, range 16 to 34 802 pg/mL) was lower than in 20 patients with adverse clinical outcome (median 4250, range 92 to 49 607 pg/mL; P<0.0001). The negative predictive value of proBNP levels <500 pg/mL to predict adverse clinical outcome was 97% (95% confidence interval 84 to 99). ProBNP remained an independent predictor for adverse clinical outcome (odds ratio 14.6; 95% confidence interval 1.5 to 139.0; P=0.02) after adjusting for severity of PE (submassive/massive), troponin T levels >0.01 ng/mL, age >70 years, gender, and history of congestive heart failure. CONCLUSIONS: Low proBNP levels predict an uneventful hospital course in patients with acute PE. A proBNP level <500 pg/mL identifies patients who will be potential candidates for an abbreviated hospital length of stay or care on a completely outpatient basis.

Acute Disease↗

Four French catheters for diagnostic coronary angiography.

A randomized study was conducted to assess the feasibility of 4 Fr catheters for diagnostic coronary angiograms. A total of 1,114 consecutive patients were randomized to 4 or 5 Fr catheters. Ease of use of catheters was subjectively assessed by the primary operator and the picture quality was assessed by two independent observers with a good interobserver variability (r = 0.94; P < 0.001). Predischarge local complications were recorded by the attending physician. No statistically significant difference was observed in the picture quality for the left coronary artery, right coronary artery, aorta, left ventricle, venous grafts, or renal arteries between the two groups. Fluoroscopy time (7.1 +/- 5.6 for 4 Fr vs. 6.7 +/- 5.7 min for 5 Fr) and contrast quantity (140 +/- 58 vs. 144 +/- 57 ml) were comparable between the two groups. There was a statistically significant difference in favor of the 5 Fr group as regards maneuverability of catheters (93% vs. 79%; P < 0.001), and 5 Fr pigtail catheters crossed the aortic valve easier than the 4 Fr pigtail catheters (91% vs. 81%; P < 0.001). Crossover to the other catheter size or a larger sheath was more frequent with 4 Fr catheters (33/522 vs. 3/592; P < 0.001). Median time to hemostasis was 9 min for 4 Fr and 14 min for 5 Fr (P < 0.001). Of the 4 Fr patients, 84% could be mobilized at 1 hr and 86% of 5 Fr patients at 2 hr. Significant hematomas were observed in 2% with 4 Fr or 5 Fr and small hematomas in 10% and 16%, respectively (P = NS). Time to discharge was comparable in both groups (4.0 +/- 3.2 with 4 Fr vs. 4.3 +/- 3.7 hr with 5 Fr). The 4 Fr catheters are a good alternative for diagnostic coronary angiograms. The increased difficulty in maneuverability and a need for catheter changes in 70% are compensated for in part by easier hemostasis. With increasing use and finesse of these catheters, the difficulty in maneuverability are likely to be overcome.

Aged↗

Transcatheter left atrial appendage occlusion with Amplatzer devices to obviate anticoagulation in patients with atrial fibrillation.

It is assumed that over 90% of clinically apparent embolisms in atrial fibrillation originate from the left atrial appendage. Recently, a percutaneous method (PLAATO technique) to occlude the left atrial appendage to the end of preventing thromboembolic complications of atrial fibrillation has been introduced into clinical practice. This technique is quite intricate and requires general anesthesia. The Amplatzer atrial septal occluder lends itself for a more simple approach to this intervention. The first 16 patients treated at four centers are described. Their age varied from 58 to 83 years. All suffered from atrial fibrillation but eight of them were in sinus rhythm at the time of implantation. All but two procedures were done under local anesthesia of the groin only. There was one technical failure (device embolization) requiring surgery. All other patients left the hospital a day after the procedure without complications. There were no problems or embolic events during an overall follow-up of 5 patient-years and all left atrial appendages were completely occluded without evidence of thrombosis at the atrial side of the device at the latest follow-up echocardiography. With the Amplatzer technique, the left atrial appendage can be percutaneously occluded with a venous puncture under local anesthesia, without echocardiographic guidance, and at a reasonable risk. It remains to be evaluated in larger series or randomized trials how the simpler Amplatzer technique compares with the complex PLAATO technique, and whether left atrial appendage closure is competitive with oral anticoagulation with warfarin or the novel ximelagatran to prevent thromboembolism in atrial fibrillation.

Aged↗

Incremental prognostic value of troponin I and echocardiography in patients with acute pulmonary embolism.

BACKGROUND: To test the hypothesis that troponin I and echocardiography have an incremental prognostic value in patients with pulmonary embolism (PE). METHODS AND RESULTS: In 91 patients with acute PE, echocardiography was performed within 4h of admission. Troponin I levels were obtained on admission and 12h thereafter. The 0.06 microg/l troponin I cut-off level was identified as the most useful, high-sensitivity cut-off level for the prediction of adverse outcome by receiver operating characteristic analysis with a sensitivity and specificity of 86%, respectively. Twenty-eight (31%) patients had elevated troponin I levels (4.9+/-3.8 microg/l). Twenty-one (23%) patients had adverse clinical outcomes including in-hospital death in five, cardiopulmonary resuscitation in four, mechanical ventilation in six, pressors in 14, thrombolysis in 14, catheter fragmentation in three, and surgical embolectomy in three. The area under the receiver operating characteristic curve from multivariate regression models for predicting adverse outcome without troponin I and echocardiography (0.765), with troponin I (0.890) or echocardiography alone (0.858), and the combination of both tests (0.900) was incremental. Three-month survival rate was highest in patients with both a normal troponin I level and a normal echocardiogram (98%). Positive predictive value for adverse clinical outcomes of the combination of echocardiography and troponin I was higher (75% (95%CI 55-88%)) compared with each test alone (echocardiography: 41%, 95% CI 28-56%; troponin I: 64%, 95% CI 46-79%). CONCLUSIONS: While troponin I measurements added most of the prognostic information for identifying high-risk patients, a normal echocardiogram combined with a negative troponin I level was most useful to identify patients at lowest risk for early death.

Acute Disease↗

Exercise-induced human coronary collateral function: quantitative assessment during acute coronary occlusions.

In 50 patients undergoing percutaneous transluminal coronary angioplasty because of chronic angina pectoris, a collateral flow index (CFI) was determined at the start and the end of two 1-min coronary occlusions, randomly accompanied by a resting state or a 3-min dynamic handgrip exercise (DHE). CFI expressing collateral flow relative to normal antegrade flow was determined by simultaneous coronary occlusive pressure, mean aortic pressure and central venous pressure measurements. When comparing CFI without and with DHE at the start as well as at the end of balloon occlusions, a significant increase was observed with DHE (overall p < 0.0001); start: 0.18 +/- 0.12 vs. 0.22 +/- 0.13, respectively (p = 0.01); end of occlusion: 0.21 +/- 0.14 vs. 0.25 +/- 0.14, respectively (p = 0.007).

Acute Disease↗

Sirolimus eluting stent: a new era in interventional cardiology?

Coronary artery stents have emerged as the preferred tool for percutaneous coronary interventions during the past decade by eliminating abrupt vessel closure and reducing restenosis compared with balloon angioplasty. While coronary artery stents prevent constrictive arterial remodeling and elastic recoil, the implantation is associated with more severe arterial vascular injury than balloon angioplasty alone. The arterial injury initiates a vasculoproliferative response with smooth muscle cell proliferation and migration as well as extracellular matrix formation, which may lead to severe neointimal hyperplasia with in-stent restenosis in 10-30% of cases. Sirolimus, a naturally occurring macrocyclic lactone, has been identified as a pharmacological cell cycle inhibitor with potent antiproliferative and antimigratory effects on vascular smooth muscle cells in vitro. The systemic administration of sirolimus has been shown to effectively reduce neointimal hyperplasia in experimental restenosis models. Subsequently, sirolimus has been incorporated at therapeutically important doses into biocompatible polymers, which made it suitable for stent-based drug elution. Investigation of sirolimus eluting stents in both experimental and clinical restenosis studies have demonstrated dramatic reductions in neointimal hyperplasia. Accordingly, sirolimus eluting stents offer an attractive mode of local drug delivery by minimizing systemic toxicity and maximizing local dose requirements. In addition, sirolimus eluting stents hold great promise to effectively prevent restenosis.

Angioplasty, Balloon, Coronary↗

Physiologically assessed coronary collateral flow and adverse cardiac ischemic events: a follow-up study in 403 patients with coronary artery disease.

OBJECTIVES: We sought to evaluate whether coronary collateral flow is clinically relevant for future cardiac ischemic events. BACKGROUND: The link between good collateral supply related to less myocardial damage and fewer cardiac events has not been established prospectively beyond doubt. METHODS: In 403 patients with stable angina pectoris undergoing percutaneous transluminal coronary angioplasty (PTCA) and quantitative collateral assessment, the occurrence of major adverse cardiac events ([MACE] cardiac death, myocardial infarction, unstable angina pectoris) and stable angina pectoris was monitored during follow-up. Collateral flow index (CFI) was determined using intracoronary pressure or Doppler guidewires. Mean aortic ([P(ao)] mm Hg) and distal coronary artery occlusive pressure ([P(occl)] mm Hg) during balloon angioplasty (PTCA), or distal coronary flow velocity time integral during ([V(occl)] cm) and after ([V(ø-occl)] cm) PTCA were measured continuously. Pressure-derived CFI was calculated as follows: (P(occl) - 5)/(P(ao) - 5). Doppler-derived CFI: V(occl)/V(ø-occl). Patients were subdivided into a group with well (CFI > or = 0.25) and poorly developed collaterals (CFI < 0.25). RESULTS: Average follow-up was 94 +/- 56 (15 to 202) weeks. There were 134 patients with CFI >or =0.25 (61 +/- 11 years) and 269 with CFI <0.25 (61 +/- 10 years). The overall cardiac ischemic event rate (MACE and stable angina pectoris) during follow-up was 23% in patients with CFI > or =0.25 and 20% in patients with CFI <0.25 (p = NS). However, only 2.2% of patients with good collateral flow suffered a major cardiac ischemic event, compared with 9.0% among patients with poorly developed collaterals (p = 0.01). The incidence of stable angina pectoris was significantly higher in patients with well developed collaterals than in those with poorly developed collaterals (21% vs. 12%; p = 0.01). CONCLUSIONS: In this relatively large population with chronic stable coronary artery disease undergoing quantitative collateral measurement, the beneficial impact of well developed collateral vessels on the occurrence of future major cardiac ischemic events is clearly demonstrated.

Aged↗

First clinical results with a new mechanical connector for distal coronary artery anastomoses in CABG.

BACKGROUND: Coronary anastomoses are currently primarily carried out with the use of running nonabsorbable sutures. Recently, a renewed interest has developed for facilitated mechanical anastomotic devices especially for minimal invasive techniques or limited access surgery. The initial experience with the first successful creation of mechanical vein-to-coronary artery anastomoses in humans is reported. METHODS AND RESULTS: Between November 2000 and June 2001, 14 patients scheduled for multivessel coronary artery bypass grafting (CABG) procedure were investigated. One vein graft-to-coronary artery anastomosis per patient was performed with the St. Jude Medical ATG Symmetry coronary connector system (stainless steel investigational device, not yet commercially available). We evaluated the overall performance of the device. Intraoperative flow measurements of the grafts using transit time methods were measured. A postoperative angiographic control was performed immediately after the procedure in all patients. Hemostasis was instantaneous in all cases and all anastomoses (mechanical n=14, sutured n=40) were patent. Mean intraoperative flow measurements for the mechanical anastomosed vein grafts was 75+/-25 mL/min. Three month angiogram or MRI angiography is available to date in 11 patients. Ten connector grafts were patent and 1 was occluded. There were no cardiac-related adverse events or return of angina; exercise tolerance tests and stress electrocardiograms were normal in all patients. CONCLUSIONS: The St. Jude Medical ATG Symmetry coronary connector system is a new device for sutureless distal vein graft-to-coronary artery anastomoses in CABG. This system allows the construction of geometrically perfect anastomoses. This technology represents a further step in a new era of sutureless anastomoses in cardiac surgery.

Anastomosis, Surgical↗

Exercise-induced coronary artery vasodilation is not impaired by stent placement.

BACKGROUND: Stenting has proved beneficial for treating threatened closure and reducing restenosis after balloon angioplasty. However, the implantation of a coronary metallic prosthesis has been related to impaired vasomotion distal to the stent as assessed by acetylcholine infusion. Thus, the purpose of the present study was to determine the vasomotion of stented coronary arteries and to assess its influence on the vasomotion of adjacent vessel segments during bicycle exercise. METHODS AND RESULTS: Biplane quantitative coronary angiography was performed at rest and during bicycle exercise in 26 patients with coronary artery disease. Twelve patients had single vessel disease with stable angina pectoris (controls; group 1). Fourteen patients underwent coronary stenting for therapeutic reasons and were studied 10+/-3 months after the intervention (group 2). Minimal luminal area, stent area, and proximal and distal vessel areas were determined. In controls (group 1), vasoconstriction of the stenotic artery (- 29+/-4%; P<0.001) was observed during exercise, whereas the normal segment showed vasodilation (15+/-4%; P<0.05). In group 2, vasomotion of the stented segment was eliminated (0+/-1%), whereas the proximal and distal segments showed exercise-induced vasodilation (8+/-2% and 11+/-3%, respectively; P<0.005), which was not different from control segments (10+/-2%). Sublingual nitroglycerin was associated with maximal vasodilation of the proximal and distal vessel segments (30+/-8% and 38+/-13%, respectively; P<0.005). CONCLUSIONS: In contrast to the vasoconstriction of vessels in control patients, normal vasodilation of proximal and distal segments occurred during the physiological stress of exercise in patients with coronary stent placement. As expected, vasomotion was abolished in the stented region.

Acetylcholine↗

Heparin and coumadin versus acetylsalicylic acid for prevention of restenosis after coronary angioplasty.

The purpose of the present study was to determine whether postprocedural antithrombotic therapy with prolonged heparin infusion followed by 6 months of oral anticoagulation in addition to acetylsalicylic acid (ASA) reduces the incidence of angiographic restenosis after successful PTCA. One hundred ninety-one patients with uncomplicated PTCA were randomized into two groups: one group was discharged with ASA 100 mg only (G1) and the other group was additionally treated with 12-24 hr of heparin infusion and overlapping oral anticoagulation with coumadin for 6 months (G2). The two groups were comparable with respect to age, gender, coronary risk profile, clinical presentation, and angiographic lesion characteristics. Stents were implanted in 33% and 36% of the G1 and G2 patients, respectively. In-hospital myocardial infarction occurred in 4% of the G1 and 3% of the G2 patients. One patient in G1 died of subacute stent thrombosis (day 3). Six-month angiographic follow-up was obtained in 90% of G1 patients and 94% of G2 patients. Restenosis occurred in 30% and 33% of the patients and mean diameter stenoses at follow-up were 40% +/- 28% and 39% +/- 24%, respectively. Thrombin inhibition with heparin infusion followed by 6 months of oral anticoagulation did not reduce angiographic restenosis among patients undergoing PTCA with or without stent implantation. The occurrence of acute ischemic complications was also comparable in the two groups.

Aged↗

Two generations of the St. Jude Medical ATG coronary connector systems for coronary artery anastomoses in coronary artery bypass grafting.

BACKGROUND: In the past, coronary anastomoses have been performed using running and, occasionally, interrupted non-resorbable sutures. Recently, special interest has developed in mechanical anastomotic devices to facilitate minimal invasive techniques or limited access surgery. The experience with two series of patients undergoing coronary artery bypass grafting (CABG) using the St. Jude Medical ATG coronary connector systems (investigational stainless steel device, not yet commercially available) for vein-to-coronary artery anastomoses is reported here. METHODS: Between November 2000 and April 2002, we evaluated two generations of distal coronary connector systems in 19 patients who were scheduled for multivessel CABG. One vein graft-to-coronary artery anastomosis per patient was performed with a stainless steel mechanical connector, in an ongoing investigational study. Although these two generations of the St. Jude Medical ATG coronary connectors have the same underlying construction, somewhat cumbersome loading of the first-generation system led to simplification of the second-generation system, which is currently evaluated. RESULTS: With the first generation of distal connector, hemostasis was instantaneous in all cases, and all anastomoses were patent at the end of the procedure. However, retrograde flow to the native coronary artery was restricted in 1 patient. The connector was removed, and the anastomosis was performed with a running suture at the same site. Three-month angiography or magnetic resonance imaging angiography was available in 11 patients with 10 patent connector grafts. With the second-generation connectors one of five had to be removed because of leakage, and the anastomosis could be sutured at the same site. The other four connector anastomoses were patent and hemostatic at the end of the procedure. CONCLUSIONS: The St. Jude Medical ATG coronary connector system is an effective device for sutureless vein graft to coronary artery anastomoses in CABG. The second-generation system presents a further development eliminating some drawbacks of the first generation such as cumbersome, time-consuming loading as well as suitability for smaller coronary arteries. These connectors allow construction of geometrically round anastomoses and theoretically may also be suitable for sequential anastomoses. After tremendous research and development efforts, an optimized mechanical connection system for small vessel anastomoses has been introduced into clinical investigation. This represents a major step in the era of sutureless vascular connections in cardiac surgery.

Aged↗